• Title/Summary/Keyword: fire fighting safety

Search Result 224, Processing Time 0.024 seconds

A Safety Assessment for 140,000kl $9\%$ Ni Steel Type LNG Storage Tank (140,000kl $9\%$니켈강식 액화천연가스 저장탱크의 안전성 평가)

  • Lee Su Kyung,;Yang Byung Dong,
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.3 s.24
    • /
    • pp.57-62
    • /
    • 2004
  • This study is to assess the safety of the process facilities and fire fighting facilities for LNG storage tank which is the main facility in the LNG receiving terminal. The LNG storage tank(capacity : 140,000kl, type : aboveground, inner tank $9\%$ Ni steel plate, outer tank : prestressed concrete) was designed by foreign country up to now, but it has designed by domestic technology as the fifth in the world is under construction now.

  • PDF

The Effect of Psychological Characteristics of Adolescents on Life Safety Awareness (청소년의 심리적 특성이 생활안전의식에 미치는 영향)

  • Sook-hee Im;JinKyoung Lee;Jai Young Lee
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.2
    • /
    • pp.49-57
    • /
    • 2023
  • The purpose of this study is to explore how adolescents' psychological characteristics affect their sense of life safety according to gender. To this end, a survey was conducted on male and female high school students in six schools in the C area, and a total of 1,048 data were used for analysis. Differences in major variables according to gender were verified, and the effect of psychological characteristics on living safety awareness was analyzed through hierarchical multiple regression analysis. As a result of the analysis, depression, anxiety, type A characteristics, and the presence or absence of experience in accidents did not significantly affect life safety awareness in the male student group. On the other hand, in the female student group, anxiety and type A characteristics had a significant effect on life safety awareness. Anxiety negatively affects living safety awareness, and type A characteristics have been shown to have a positive effect on living safety awareness. The presence or absence of depression and accident experience did not significantly affect life safety awareness. The results of these studies suggest that gender differences should be considered in education to prevent life safety awareness and that education that reflects the psychological characteristics of adolescents is necessary.

Analysis of the Evacuation Safety in a Fire at Welfare Center for Disabled (장애인복지관 화재 시 피난안전성 분석)

  • Park, Sunah;Lee, Jai Young
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.12
    • /
    • pp.315-322
    • /
    • 2021
  • This study analyzes the Required Safe Egress Time (RSET), in the event of a fire at a welfare center for the disabled, using the emergency passage according to the floor arrangement of users to evaluate the safety and the difference in RSET for each emergency passage using the Pathfinder simulation program to suggest an efficient evacuation method. As a result of RSET, it was found that there is no problem in evacuation safety for the current state of the facility's personnel allocation by satisfying the standard RSET in case of fire, and evacuation can be completed safely by evacuating through stairs rather than using elevators if possible. It is necessary for employees to be provided sufficient education and training in advance so that they can evacuate effectively with the disabled in case of fire. This study gives significance in saving many precious lives and safely evacuate in case of fire as evacuation routes were secured through the design, construction and operation of facilities for the disabled and the RSET was shortened through regular evacuation practices. It is necessary to discuss the further RSET studies based on the automatic fire shutters open or not when a fire occurs at a specific location following the installation of automatic fire shutter at the entrance of each floor of the facilities.

An Empirical Study on Importance of Evaluation Factors for Improvement of Fire Emergency Medical Service (소방응급의료서비스 향상을 위한 평가요인의 중요도에 관한 실증적 연구)

  • Hwang, Dong-Wan;Kwon, Young-Hee;Kim, Jeon-Soo;Kang, Yun-Jin;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.71-80
    • /
    • 2014
  • This study is performed to determine the priorites of the evaluation factors for the improvement of fire emergency medical service by increasing it's efficiency to protect the people's lives effectively, and by recognizing it's mid-long term development. Based on the output of the analysis, the critical evaluation factors of the fire emergency medical services to be improved shall be identified, and shall be intended to use strategically for increasing the efficiency of all the activity in the EMT service, and also for providing the basic date to product and manage the good quality services. To calculate the priority of the evaluation factor for each level as shown on this study, AHP(anaysis hierarchy process) with pairwise comparison method is applied. According to the priority analysis for the evaluation factors in main category (evaluation zone), 'medical service professional aspect' is recognized as highest one, and 'service infrastructure aspect', 'service management aspect' are indicated in order. According to the priority analysis for the evaluation factors in evaluation index, 'professional personal arrangement' in the service infrastructure aspect, 'appropriateness and timeliness of emergency medical care' in the medical service professional aspect, and 'clinical training' in the service management aspect are respectively recognized as most important factors.

The 2018 Fire department emergency medical technician survey (2018년 소방공무원 응급구조사 총조사)

  • Yun, Hyeongwan;Park, Jooho;Lee, Hyeongyeong;Han, Seungtae;Lee, Jeamin
    • The Korean Journal of Emergency Medical Services
    • /
    • v.25 no.3
    • /
    • pp.145-162
    • /
    • 2021
  • Purpose: The 2018 General survey of emergency assistance was conducted to examine the working conditions and welfare, including educational direction, interests, and awareness of work, of the fire department emergency medical technicians (EMT). This would be used as basic data for future policy directions. Methods: Among the fire-fighting officers in 16 cities nationwide, emergency rescue workers engaged in first-aid activities were targeted. With prior consent, a survey was conducted through electronic documents. Of the total 1,227 people, responses from 1,151 were finally analyzed, excluding 76 who did not respond appropriately. Results: The working conditions and welfare of 119 firefighters were moderate, but in the fields of education and interest, the learning according to the regulations was high. In particular, satisfaction with the scope of work was found to be below average. However, it was positive that it will play a role as a social safety net in the future and will converge with cutting-edge science. Conclusion: Although this study was a total investigation of the EMT survey, conducting an EMT survey on all fire fighters in Korea is difficult. Further research is needed, particularly on first-class emergency medical personnel who play a major role in 119 paramedics.

Evaluation of the Activation Energy of Chlorinated Poly Vinyl Chloride (CPVC) Using Thermogravimetric Analysis (TGA를 이용한 Chlorinated Poly Vinyl Chloride(CPVC)의 활성화 에너지 평가)

  • Park, Hyung-Ju
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.1-6
    • /
    • 2019
  • The activation energy of CPVC (Chlorinated Poly Vinyl Chloride) used for non-metallic synthetic resin piping in fire-fighting was measured by thermogravimetric analysis (TGA). The activation energy was determined using by TGA kinetic methods, such as Kissinger and Flynn-Wall-Ozawa method. The calculated activation energy was 128.07 kJ/mol (Kissinger method) and 145.60 kJ/mol (Flynn-Wall-Ozawa method). The difference in activation energies calculated by the Kissinger method and Flynn-Wall-Ozawa method was not considered to be significant considering that the different analysis methods. The combustion characteristics will be tested in a future study through an evaluation of thermal deterioration using an accelerated deterioration and air oven aging test and the lifetime of CPVC will be predicted.

A Study on the Improvement of the Refuge safety area in High-rise Buildings Type (초고층 건축물의 용도별 피난안전구역 성능확보 방안에 관한 연구)

  • Lee, Byung-Hyun;Lee, Kyung-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.7
    • /
    • pp.288-292
    • /
    • 2016
  • The purpose of this study was to improve the refuge safety area in the high-rise building type. Each simulation was conducted to evaluate the performance of three types in improving the refuge safety area. Targeting the first 63 floors (no refuge safety area), secondly, to target up to the $30^{th}$ floor (refuge safety area on the $30^{th}$ floor, $47^{th}$ floor) specified in domestic laws, and finally, the $20^{th}$ floor (evacuation safety area on the $20^{th}$ floor, $42^{th}$ floor) were considered as targets. Through this analysis, the following results were obtained : The floor for the refuge safety area through simulations showed that the evacuation time is low. It is necessary to improve the floor for the refuge safety area by using the characteristics of the domestic fire fighting vehicle. The first floor for the refuge safety area from the ground floor differs according to the distance and height of the building floor. However, in the case of a business facility it is 15F, and in the case of apartment housing, it is 20F.

Study of a Improvement Plans about Efficient Operation of Korean Volunteer Fire Departments (우리나라 의용소방대의 효율적인 운영에 관한 개선방안 연구)

  • Kim, Hyeong-Do;Lee, Si-Young
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.95-106
    • /
    • 2017
  • This study sought for an improvement plan of overall fire-fighting activities and all kinds of support activities of service for public welfare of Korean Volunteer Fire Departments by utilizing the internal fire administration data and statistical yearbooks of the (Old)Ministry of Public Safety and Security (MPSS), the statistics of the (Old) National Emergency Management(NEMA), and the data of the National Statistical Office (NSO) of 5 years from 2012 to 2016 and drawing the practical problems through the statistical analysis. The results of the study are as follows: First, the quota management system of Volunteer Fire Departments that considers the characteristics of rural areas should be supplemented. Second, the culture and training system to solve internal conflict factors of Volunteer Fire Departments should be strengthened. Third, management members readership competency of operating organizations including volunteer fire marshals should be strengthened. Fourth, the education and training system of Volunteer Fire Departments to satisfy regional conditions should be established. Fifth, the reward system for Volunteer Fire Departments' activities of large disaster sites should be improved. The result of the study will be expected to be utilized as the basic data to develop Korean Volunteer Fire Departments in the future.

Study of the Real Condition and Improvement Plans of a Fire Protection System Installed at Museum Storage (수장고에 설치된 소방시설의 실태 및 개선방안에 관한 연구)

  • Park, Jong-A;Joo, Seung-Ho;Kang, Eun-Soo;Lee, Dae-Keon
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.60-66
    • /
    • 2018
  • Museum storage has been a unique area for experts, such as curators and managers etc., is a part that requires attention among the recent changes in museums because of changes to a type that is being opened gradually to visitors. On the other hand, there is an increased the risk of a fire according to negligence etc. of visitors. Hence, appropriate measures for a fire protection system to respond to varying museum storage are required. This study examined the status of fire protection systems applied to museum storage visiting 40 domestic public museums with the support of the Ministry of Culture, Sports and Tourism, and a direction to install a fire protection system was presented by drawing cases of fire protection systems with less adaptability or poor management or excellent fire protection systems, and a direction for improvement was presented.

The Development of a Ship Firefighting Drill Simulator (선박소화훈련 시뮬레이터 개발에 관한 연구)

  • Kim, Won-Ouk;Kim, Dae-Hee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.5
    • /
    • pp.410-416
    • /
    • 2016
  • After the Sewol Ferry accident, the importance of maritime safety has been emphasized in Korea. In particular, educational and experience training are not only being conducted for maritime personnel but also in schools and at maritime-related organizations in order to broadly instill maritime safety awareness. Based on SOLAS regulations, safety education for sailors conducted every 10 days passenger boats, and fire-fighting drills and abandon-ship training should be conducted once a month on merchant ships. After the Sewol Ferry accident, the maximum number of trainees was reduced from 40 to 20 in order to improve the effectiveness of these training sessions by requiring all trainees to participate in the actual training. The current training process consists of two steps: textbook-based theoretical training and actual practice. Current training environment provides limited capability from human and facility recourses which limit the numbers of trainee participated and system operation time. By introducing the simulation training, it will improve the trainee skill and performance prior to the on-site training and allow the more effective and rapid progress on actual practice. Therefore, it will be proposed the three-step training method in order to improve the effectiveness on fire-fighting drill in Maritime Safety Education on this study. This study suggests a three step training method that would increase the efficiency of maritime safety education. An image-training step to enhance individual task awareness and equipment usage via simulation techniques after theoretical training has been added. To implement this simulation, a virtual training session will be conducted before actual training, based on knowledge obtained from theoretical training, which is expected to increase the speed with which trainees can adapt during the practical training session. In addition, due to the characteristics of the simulation, repeated training is possible for reaction drills in emergency circumstances and other various scenarios that are difficult to replicate in actual training. The efficiency of training is expected to improve because trainees will have practiced before practical training takes place, which will decrease the time needed for practical training and increase the number of training sessions that can be executed, increasing the efficiency of training overall. This study considers development methods for fire-fighting drill simulations using virtual reality techniques.