• Title/Summary/Keyword: finite difference coefficient

Search Result 187, Processing Time 0.023 seconds

New approach method of finite difference formulas for control algorithm (제어 알고리즘 구현을 위한 새로운 미분값 유도 방법)

  • Kim, Tae-Yeop
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.817-825
    • /
    • 2019
  • Difference equation is useful for control algorithm in the microprocessor. To approximate a derivative values from sampled data, it is used the methods of forward, backward and central differences. The key of computing discrete derivative values is the finite difference coefficient. The focus of this paper is a new approach method of finite difference formula. And we apply the proposed method to the recursive least squares(RLS) algorithm.

Prediction of Three Dimensional Turbulent flows around a MIRA Vehicle Model (MIRA Vehicle Model 주위의 3차원 난류유동 예측)

  • 명현국;진은주
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.5
    • /
    • pp.86-96
    • /
    • 1998
  • A numerical study has been carried out of three-dimensional turbulent flows around a MIRA reference vehicle model both with and without wheels in computation. Two convective difference schemes with two k-$\varepsilon$ turbulence models are evaluated for the performance such as drag coefficient, velocity and pressure fields. Pressure coefficients along the surfaces of the model are compared with experimental data. The drag coefficient, the velocity and pressure fields are found to change considerably with the adopted finite difference schemes. Drag forces computed in the various regions of the model indicate that design change decisions should not rely just on the total drag and that local flow structures are important. The results also indicate that the RNG model with the QUICK scheme predicts fairly well the tendency of velocity and pressure fields and gives more reliable drag coefficient rather than the other cases.

  • PDF

Convection Heat Transfer Coefficient of a Meat Cube in a Continuous Flow Sterilizing System

  • Hong, Ji-Hyang;Han, Young-Joe;Chung, Jong-Hoon
    • Food Science and Biotechnology
    • /
    • v.14 no.3
    • /
    • pp.328-333
    • /
    • 2005
  • Finite difference model and dynamic thermal property evaluation system were developed to estimate convection heat transfer coefficient by modeling temperature-time profile of beef cube in continuous flow sterilizing system. As input parameters of the model, specific heat and thermal conductivity values of beef frankfurter meat were independently measured from 20 to $80^{\circ}C$. Convection heat transfer coefficient was estimated by comparing simulated and measured temperature-time profiles. Actual temperature-time profiles of meat cube were measured at flow rates of 15, 30, and 45 L/min and viscosities from 0 to 15 cp, and mean values of convection heat transfer coefficients ranged from 792 to $2107\;W/m^2{\cdot}K$. Convection heat transfer coefficient increased with increase in flow rate and decreased as viscosity increased.

Simulation of Three-Dimensional Turbulent Flows around an Ahmed Body-Evaluation of Turbulence Models- (Ahmed Body 주위의 3차원 난류유동 해석 - 난류모델의 평가)

  • Myong, H.K.;Jin, E.;Park, H.K.
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.7
    • /
    • pp.873-881
    • /
    • 1997
  • A numerical simulation has been carried out for three-dimensional turbulent flows around an Ahmed body. The Reynolds-averaged Navier-Stokes equation is solved with the SIMPLE method in general curvilinear coordinates system. Several k-.epsilon. turbulence models with two convective difference schemes are evaluated for the performance such as drag coefficient, velocity and pressure fields. The drag coefficient, the velocity and pressure fields are found to be changed considerably with the adopted k-.epsilon. turbulence models as well as the finite difference schemes. The results of simulation prove that the RNG k-.epsilon. model with the QUICK scheme predicts fairly well the tendency of velocity and pressure fields and gives more reliable drag coefficient. It is also demonstrated that the large difference between simulations and experiment in the drag coefficient is due to relatively high predicted values of pressure drag from vertical rear end base.

Buckling and vibration of rectangular plates of variable thickness with different end conditions by finite difference technique

  • Rajasekaran, Sundaramoorthy;Wilson, Antony John
    • Structural Engineering and Mechanics
    • /
    • v.46 no.2
    • /
    • pp.269-294
    • /
    • 2013
  • This paper is concerned with the determination of exact buckling loads and vibration frequencies of variable thickness isotropic plates using well known finite difference technique. The plates are subjected to uni, biaxial compression and shear loadings and various combinations of boundary conditions are considered. The buckling load is found out as the in plane load that makes the determinant of the stiffness matrix equal to zero and the natural frequencies are found out by carrying out eigenvalue analysis of stiffness and mass matrices. New and exact results are given for many cases and the results are in close agreement with the published results. In this paper, like finite element method, finite difference method is applied in a very simple manner and the application of boundary conditions is also automatic.

Evaluation of Coefficient of Consolidation for Dilatory Dissipation Result of Piezocone Test (피에조콘 소산시험시 지연소산이 발생한 경우에 대한 압밀계수 평가 방법)

  • Ha, Tae-Gyun;Chung, Choong-Ki
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1328-1339
    • /
    • 2008
  • For a commonly used piezocone with a shoulder filter element, dilatory dissipation behavior, which shows an initial temporary increase in pore pressure, has been observed in overconsolidated cohesive soils. However, there is no appropriate way to estimate a consolidation parameter from a dilatory dissipation curve because currently available interpretation methods were developed based on the monotonic decrease of the excess pore pressure. In this study, the interpretation method for evaluation of coefficient of consolidation from a dilatory dissipation result of piezocone test was developed by performing the finite difference analysis on the dissipation after cone penetration. The distribution of the initial excess pore pressure induced by cone penetration, which is the core of the analysis, was estimated from the empirical modification of a solution proposed by cavity expansion theory and critical state concept. And the proposed interpretation method was applied to the field piezocone data and the results were compared to those obtained from laboratory tests. Its reliability was confirmed by the insignificant difference between the values of coefficient of consolidation from piezocone tests and laboratory consolidation tests.

  • PDF

A TRACE-TYPE FUNCTIONAL METHOD FOR DETERMINATION OF A COEFFICIENT IN AN INVERSE HEAT CONDUCTION PROBLEM

  • WEN, JIN;CHENG, JUN-FENG
    • Journal of applied mathematics & informatics
    • /
    • v.35 no.5_6
    • /
    • pp.439-447
    • /
    • 2017
  • This paper investigates the inverse problem of determining an unknown heat radiative coefficient, which is only time-dependent. This is an ill-posed problem, that is, small errors in data may cause huge deviations in determining solution. In this paper, the existence and uniqueness of the problem is established by the second Volterra integral equation theory, and the method of trace-type functional formulation combined with finite difference scheme is studied. One typical numerical example using the proposed method is illustrated and discussed.

Performance evaluation technique of a heat exchanger using a transient response analysis (과도응답해석을 이용한 열교환기의 성능평가방법에 관한 연구)

  • Park, B.K.;Hong, T.;Park, S.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.81-90
    • /
    • 1999
  • The performance evaluation technique of a heat exchanger is described by using a transient response analysis for the determination of an average heat transfer coefficient. The model using a finite difference method can accommodate arbitrary inlet fluid temperature as well as longitudinal conduction. Temperature histories are obtained from the experiments at the inlet and outlet of test core. Heat transfer coefficient and friction factor of the plate array are obtained in short times using the data reduction program of transient response analysis in the single-blow method. The results agree very well with theoretical results. It is shown that the rms deviations are very small and the performance evaluation technique gives rapid and accurate results.

  • PDF

Simulation of Three-Dimensional Turbulent Flows around an Ahmed Body-Evaluation of Finite Differencing Schemes- (Ahmed body 주위의 3차원 난류유동 해석-유한차분도식의 평가-)

  • Myeong, Hyeon-Guk;Park, Hui-Gyeong;Jin, Eun-Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.11
    • /
    • pp.3589-3597
    • /
    • 1996
  • The Reynolds-averaged Navier-Stokes equations with the equations of the k-.epsilon. turbulence model are solved numerically in a general curvilinear system for a three-dimensional turbulent flow around an Ahmed body. The simulation is especially aimed at the evaluation of three finite differencing schemes for the convection term, which include the upwind differencing scheme(UDS), the second order upwind differencing scheme(SOU scheme) and the QUICK scheme. The drag coefficient, the velocity and pressure fields are found to be changed considerably with the adopted finite differencing schemes. It is clearly demonstrated that the large difference between computation and experiment in the drag coefficient is due to relatively high predicted values of pressure drag from both front part and vertical rear end base. The results also show that the simulation with the QUICK or SOU scheme predicts fairly well the flow field and gives more accurate drag coefficient than other finite differencing scheme.

Analysis on Monopole Antenna for Moisture Determination in Oil Palm Fruit Using Finite Difference Method

  • Cheng, E.M.;Abbas, Z.;Rahim @ Samsuddin, H.A.;Lee, K.Y.;You, K.Y.;Hassan, J.;Zainuddin, H.;Khor, S.F.
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1754-1762
    • /
    • 2016
  • Finite difference analysis were applied to study the principle operation of monopole antenna for moisture determination in oil palm fruit at 2 GHz. The electromagnetic field interact with oil palm fruit on the interface between the antenna and oil palm fruit and cause a reflection. The reflection measurement is based on mismatch impedance or dielectric properties between two media. Reflection coefficient is used to quantify the level of reflection. The monopole antenna was made of RG405/U semi-rigid coaxial cable with an inner and outer diameter of 0.45 mm and 1.50 mm, respectively with 2.23 mm length of protruding conductor over 5.66 cm length of monopole antenna. This monopole antenna for moisture detection was compared with induced EMF method in terms of reflection coefficient at 2 GHz. The results show that the complex reflection coefficient measured using monopole antenna provides significant results to predict moisture content in oil palm fruit.