• Title/Summary/Keyword: finger ratio

Search Result 112, Processing Time 0.026 seconds

Comparison of Compliance, Time Required for Diagnosis and Pain of Patients with Finger Tendon Injury Between Gross and Ultrasonographic Confirmation (손가락 힘줄 손상환자에서 육안 검사와 초음파 검사의 순응도, 시간, 통증의 비교)

  • Lee, Seo-Woo;Park, Hyun-Jae;Lee, Jung-Won;Park, Sae-Hoon;Kim, Jae-Woo
    • Journal of Trauma and Injury
    • /
    • v.23 no.2
    • /
    • pp.83-88
    • /
    • 2010
  • Purpose: It is not always easy to determine the existence of tendon injuries when it comes to patients with finger lacerations. Thus, we tried to find the difference in effectiveness and in compliance of patients when we employed two different types of diagnosis, conventional gross confirmation and ultrasonographic confirmation. Methods: From December 2009 to March 2010, we enrolled 14 patients with finger tendon injury at Soonchunhyang University Cheonan Hospital. The median age of the patients was $35.9{\pm}14.4$, and the ratio of females to males was 1:2.5 We evaluated the compliance of each patient by measuring four different categories (level of cooperativeness in showing their wound and in following the instructions, level of movement of their fingers during the diagnosis and total number of attempts to diagnose) by using a score from 1 to 3 for each category, for a total possible score of 12 for each patient. We also measured the painfulness of each patient by using a score of 1 to 10 and the time required for each diagnosis. Results: The levels of patients' compliance was $8.9{\pm}2.1$ when diagnosed with gross confirmation and $9.8{\pm}2.1$ when diagnosed with ultrasonographic confirmation (p value=0.042). The pain score of the patients was $3.7{\pm}1.7$ with gross confirmation and $2.9{\pm}1.2$ with ultrasonographic confirmation (p value=0.020). The median duration of time in each test was $6.7{\pm}4.8$ minutes with gross confirmation and $10.5{\pm}4.2$ minutes with ultrasonography (p value=0.006). Conclusion: Comparing gross confirmation and ultrasonographic confirmation, gross confirmation is a better method than ultrasonography because of time efficiency. However, ultrasonographic confirmation has advantages over gross confirmation in pain scale and better compliance of patients. Emergency physicians generally employ gross confirmation rather than ultrasonography in determining the existence of tendon injury in patients. In patients with finger lacerations without bone injury, ultrasonography can be considered as a secondary diagnostic tool, especially when patients have much pain.

Development of a Comb-parallel Type Micro Actuator with High Aspect Ratio (높은 세장비의 Comb-parallel 타입 마이크로 액츄에이터의 개발)

  • 이승재;조동우;김종영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.848-853
    • /
    • 2001
  • Electrostatic actuation was adopted for ease of fabrication. We proposed a new driving scheme that uses the vector sum of force generated by comb-finger and by parallel plate. The moving and fixed electrodes are arranged to maximize the driving force. In this paper, an electrostatic field analysis is performed by Maxwell analysis tool for micro actuators. From the analysis, a comb-parallel type micro-actuator with 4${\mu}{\textrm}{m}$ width, 6${\mu}{\textrm}{m}$ overlap and 45${\mu}{\textrm}{m}$ height could be designed. In order to compare the new type of actuator with the conventional comb type of actuator, we arranged that both types have the same area and the same number of actuators. To make a high aspect ratio structure, we are developing fabrication process using SU-8 and electro-plating.

  • PDF

A Study on High Performance Fine-Grained Concrete Containing Rice Husk Ash

  • Le, Ha Thanh;Nguyen, Sang Thanh;Ludwig, Horst-Michael
    • International Journal of Concrete Structures and Materials
    • /
    • v.8 no.4
    • /
    • pp.301-307
    • /
    • 2014
  • Rice husk ash (RHA) is classified as a highly reactive pozzolan. It has a very high silica content similar to that of silica fume (SF). Using less-expensive and locally available RHA as a mineral admixture in concrete brings ample benefits to the costs, the technical properties of concrete as well as to the environment. An experimental study of the effect of RHA blending on workability, strength and durability of high performance fine-grained concrete (HPFGC) is presented. The results show that the addition of RHA to HPFGC improved significantly compressive strength, splitting tensile strength and chloride penetration resistance. Interestingly, the ratio of compressive strength to splitting tensile strength of HPFGC was lower than that of ordinary concrete, especially for the concrete made with 20 % RHA. Compressive strength and splitting tensile strength of HPFGC containing RHA was similar and slightly higher, respectively, than for HPFGC containing SF. Chloride penetration resistance of HPFGC containing 10-15 % RHA was comparable with that of HPFGC containing 10 % SF.

An Acoustic Analysis of Noise Environments during Mobile Device Usage

  • Park, Hyung Woo
    • International journal of advanced smart convergence
    • /
    • v.6 no.2
    • /
    • pp.16-23
    • /
    • 2017
  • In contemporary modern society, people are constantly exposed to many kinds of noise, such as that from machinery, aircraft, construction sites, or road traffic. Noise is considered one of the most indispensable and influential parts of human life. This study investigates the acoustic characteristics of noise transfer from external sources to the human ear. For this study, we measured and analyzed various types of noise environments, installed monitoring speakers in a semi-anechoic room, and conducted intentional noise-filled experiments. In this environment, the size of the sounds generated by use of a portable device was also measured and the SNR (signal to noise ratio) calculated to study the influence of the noise. As sound is transmitted to the ear and the human body, it affects not only auditory damage but also other parts of the body. In this paper, we propose a proper SNR for noise emitted by portable IT equipment to prevent hearing loss when IT equipment is used.

Study on the manufacturing of high-frequency heating Japanese cedar laminated board by finger jointing method (1) - Gluing characteristics of Japnese cedar board by PVAc emulsion adhesives - (핑거접합방식에 의한 삼나무의 고주파가열 집성판 제조에 관한 연구 (1) - 삼나무 판재의 초산비닐수지 접착특성 -)

  • So Won-Tek;Chai Jyung-Ki
    • Journal of the Korea Furniture Society
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 2005
  • This experiment was carried out to investigate the gluing characteristics of poly vinyl acetate emulsion adhesive(PVAc) on the Cryptomeria japonica laminated boards. This sample trees are major planting species and have been planted in southern district for a long time. The optimum gluing conditions for laminated board were summarized as follows; the amount of spreading glue, assembly time, clamping pressure, and clamping time for PVAc resin were $200g/m^2$, 10min., $5kg/cm^2$, and 6hrs., respectively, and the relative formulae between extension ratio(x) and block shear strength(y) was $y=-9.6x+85.2(R^2=0.95)$.

  • PDF

Classification and Identification of Korean Hand Shapes based on Anthropometric Hand Data Analysis (손 관련 인체측정자료를 이용한 한국인의 손 모양 유형 분류 및 특성 분석)

  • Kim, Sang-Ho;Kee, Do-Hyung
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.1
    • /
    • pp.75-85
    • /
    • 2012
  • In this study, the representative hand shapes for the adult Koreans were analyzed by factor analysis and cluster analyses. The analyses were conducted on the anthropometric data of 58 hand dimensions from 325 subjects having nonhomogeneous demographics. Maximum hand circumference, first phalanx length of index finger, and ratio between the two measures were the independent variables for the cluster analyses. The results of the study showed that Korean hand shapes can be divided into 2 clusters irrespective of their size for each of the male and female group. There were slight differences in component ratio of hand shapes with respect to the occupation and the age, but their differences were not statistically significant. The representative Korean hand shapes and their anthrpometric dimensions could be used to design and establish proper sizing system for various hand operating devices.

Non-Destructive Detection of Hydride Blister in PHWR Pressure Tube Using an Ultrasonic Velocity Ratio Method

  • Cheong Yong-Moo;Lee Dong-Hoon;Kim Sang-Jae;Kim Young-Suk
    • Nuclear Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.369-377
    • /
    • 2003
  • Since Zr-2.5Nb pressure tubes have a high risk for the formation of blisters during their operation in pressurized heavy water reactors, there has been a strong incentive to develop a method for the non-destructive detection of blisters grown on the tube surfaces. However, because there is little mismatch in acoustic impedance between the hydride blisters and zirconium matrix, it is not easy to distinguish the boundary between the blister and zirconium matrix with conventional ultrasonic methods. This study has focused on the development of a special ultrasonic method, so called ultrasonic velocity ratio method for a reliable detection of blisters formed on Zr-2.5Nb pressure tubes. Hydride blisters were grown on the outer surface of the Zr-2.5Nb pressure tube using a cold finger attached to a steady state thermal diffusion equipment. To maximize a difference in the ultrasonic velocity in hydride blisters and the zirconium matrix, the ultrasonic velocity ratio of longitudinal wave to shear wave, $V_L/V_S$, has been determined based on the flight time of the longitudinal echo and reflected shear echo from the outer surface of the tubes. The feasibility of the ultrasonic velocity ratio method is confirmed by comparing the contour plots reproduced by this method with those of the blisters grown on the Zr-2.5Nb pressure tubes.

Development of early diagnosis system for the detection of diabetic foot using photoplethysmograph (PPG를 이용한 당뇨병 환자의 족부질환의 조기진단 시스템 개발)

  • Kim Jin-Tae;Kim Sung-Woo;Hong Hyun-Ki;Im Jae-Joong;Kim Deok-Won
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.3 s.309
    • /
    • pp.60-66
    • /
    • 2006
  • The purpose of this study was to suggest a new detection method for early diagnosing diabetic neuropathic foot by obtaining a ratio of toe to finger blood flow using photoplethysmography(PPG) and Laser Doppler(LD). Nerve conduction velocity (NCV) has been routinely used for diagnosing neuropathic foot, but it applies strong electric stimulus to peripheries resulting in stress and pain. The blood flow ratio of 50 neuropathic diabetes($0.96{\pm}0.20$) was significantly higher than that of 64 normal person($0.46{\pm}0.15$)(p<0.000). It also showed that toe temperature of neuropathic diabetes($30.5{\pm}1.4^{\circ}C$) was significantly higher than that of normal group($29.3{\pm}2.0^{\circ}C$)(p<0.000). The optimal boundary value of the blood flow ratio was found to be 0.678 and the sensitivity and specificity of this proposed method resulted in 95.3% and 95.3% respectively. Lastly, there were no neuropathic diabetes whose temperature difference between finger and toe was higher than $4.5\;^{\circ}C$.

The Effect of the Ratio of Standing to Sitting Height on the Spinal Forward Bending Range of Motion in Normal Subjects (앉은 자세와 기립 자세의 비율이 정상 성인의 체간 굴곡 유연성에 미치는 영향)

  • Kwon, Hyuk-Cheol;Jeong, Dong-Hoon
    • Physical Therapy Korea
    • /
    • v.8 no.2
    • /
    • pp.55-63
    • /
    • 2001
  • For spinal flexibility measurements to be meaningful to clinicians or researchers, they must have a normative information and an understanding of how different variables affect spinal range of motion (ROM). Normal spinal ROM measurements are influenced to differing degrees by many factors. These factors include age, gender, time of day, leisure activities, previous history of low back pain, warming up, and the techniques with which normative data are collected. The additional variables of standing height, ratio of standing height to sitting height, and obesity had not been previously studied extensively and were shown to have a significant effect on flexibility in the sagittal plane. These relationship cannot be explained easily. Thus, the purpose of this study was to determine the relationship between spinal flexibility and individual factors (weight, standing height, and ratio of standing height to sitting height) that influence it. Fifteen healthy subjects between the ages of 20 and 27 years were studied. Two physical therapists measured independently the spinal forward bending ROM in the sagittal plane by Remodified Schober test and Finger-to-floor test. In order to determine the statistical significance of the result the Pearson's correlation was applied at the .05 level of significance. The results of this study were as follows: 1) Significant relationship was not identified between spinal flexibility and weight. 2) Significant relationship was not identified between spinal flexibility and standing height. 3) Significant relationship was not identified between spinal flexibility and ratio of standing height to sitting height.

  • PDF

Arterial or venous free flaps for volar tissue defects of the proximal interphalangeal joint: A comparison of surgical outcomes

  • Choi, Min Suk;Roh, Si Young;Koh, Sung Hoon;Kim, Jin Soo;Lee, Dong Chul;Lee, Kyung Jin;Hong, Min Ki
    • Archives of Plastic Surgery
    • /
    • v.47 no.5
    • /
    • pp.451-459
    • /
    • 2020
  • Background For volar soft tissue defects of the proximal interphalangeal (PIP) joint, free flaps are technically challenging, but have more esthetic and functional advantages than local or distant flaps. In this study, we compared the long-term surgical outcomes of arterial (hypothenar, thenar, or second toe plantar) and venous free flaps for volar defects of the PIP joint. Methods This was a single-center retrospective review of free flap coverage of volar defects between the distal interphalangeal and metacarpophalangeal joint from July 2010 to August 2019. Patients with severe crush injuries (degloving, tendon or bone defects, or comminuted/intra-articular fractures), thumb injuries, multiple-joint and finger injuries, dorsal soft tissue defects, and defects >6 cm in length were excluded from the study, as were those lost to follow-up within 6 months. Thirteen patients received arterial (hypothenar, thenar, or second toe plantar) free flaps and 12 received venous free flaps. Patients' age, follow-up period, PIP joint active range of motion (ROM), extension lag, grip-strength ratio of the injured to the uninjured hand, and Quick Disabilities of Arm, Shoulder & Hand (QuickDASH) score were compared between the groups. Results Arterial free flaps showed significantly higher PIP joint active ROM (P=0.043) and lower extension lag (P =0.035) than venous free flaps. The differences in flexion, grip strength, and QuickDASH scores were not statistically significant. Conclusions The surgical outcomes of arterial free flaps were superior to those of venous free flaps for volar defects of the PIP joint.