• 제목/요약/키워드: finger force

검색결과 187건 처리시간 0.026초

수지진동에서의 진동강도, 손잡이온도, 소음 및 미는 힘의 복합효과에 따른 악력 및 지단피부온의 변화 (Combined Effect of Vibration Intensity, Grip Temperature, Noise and Pushing Power on Grip Forces and Skin Temperatures of Fingers)

  • 고경심
    • Journal of Preventive Medicine and Public Health
    • /
    • 제27권4호
    • /
    • pp.763-776
    • /
    • 1994
  • Recent studies reveal that grip forces during the hand-arm vibration are most significant for the genesis of vibration-induced white linger syndrome. Therefore, exerted grip forces and skin temperatures of fingers were regarded as dependent variables in experiments and the effects of grip temperature, noise, pushing force, vibration and the combined effect of vibration and pushing force were studied. The objectives of the present study were, first, to varify and compare the changes of grip force affected by grip temperature, noise, pushing force, vibration and the combined effect of vibration and pushing force and, second, to observe the reaction of finger skin temperature affected by above factors. Forty-six healthy male students ($25.07{\pm}2.85$) participated in five systematically permuted trials, which endured 4 minutes each other. Experiments were executed in a special chamber with an air temperature of 21C. In each experiments, the subjects were exposed to five experiment types: (1) grip force of 25N only, (2) pushing force of 50N, (3) acceleration of vibration $7.1m/sec^2(z-direction)$, (4) pink noise of 95 dB (A) and (5) combination of pushing force 50N and acceleration of vibration $7.1m/sec^2$. A repeated-measures analysis of variance (ANOVA) was performed on the grip force to test whether it was affected by noise, pushing force, vibration and pushing force. The present results show that vibration was significantly related to the increase of grip force, but the other factors, such as pushing force, noise and grip temperature had no signigicant influence on the increase of grip force, and that the reaction of finger skin temperature were significantly affected by the skin temperature at start of experiment and grip temperature, not grip force and other experimental conditions. Therefore, we suggest that the management for decreasing the grip force is meaningful to prevent the occurrence of Hand-arm vibration syndrome (HAVS).

  • PDF

전기활성 고분자 구동체에 의한 손가락 모형의 집기 운동 분석 (Analysis of Pinching Motion of a Finger Dummy Actuated by Electro-active Polymer Actuators)

  • 이두원;민민식;이수진;조재영;김동민;이계한
    • 한국정밀공학회지
    • /
    • 제31권7호
    • /
    • pp.643-649
    • /
    • 2014
  • In order to demonstrate the possibility of applying an ionic polymer metal composite (IPMC) to a finger exoskeleton, pinching motion analysis was performed for a thumb-index finger dummy actuated by IPMC actuators. The IPMC actuators of 5mm in width and 40mm in length with 2.4mm thickness generated 1.52N of blocking force for the applying voltage of 4.0V. Three actuators were installed on the three rotary joint of an index finger, and one actuator was installed on one proximal joint. Positions of each joint and finger tip were recorded on the video camera, and motion was analyzed. Power supply to the index finger actuators preceded power supply to the thumb actuator, and key pinching motion was accomplished in 180s. Tip pinching was accomplished in 135s as power supply to the thumb preceded power supply to the index finger.

고 감지 전압을 이용한 개인 정보기기용 고정도 정전용량형 단결성 실리콘 가속도계 (A High Resolution Capacitive Single-Silicon Microaccelerometer using High Amplitude Sense Voltage for Application to Personal Information System)

  • 한기호;조영호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집C
    • /
    • pp.53-58
    • /
    • 2001
  • This paper presents a high resolution capacitive microaccelerometer for applications to personal information systems. We reduce the mechanical noise level of the microaccelerometer by increasing the proof-mass based on deep RIE process. We reduce the electrical noise level by increasing the amplitude of an AC sense voltage. The high sense voltage is obtained by DC-to-DC voltage multiplier. In order to solve the nonlinearity problem caused by the high sense voltage, we modify the conventional comb electrode of straight finger type into that of branched finger type, resulting in self force-balancing effects for enhanced detection linearity. The proposed branched finger capacitive microaccelerometer was fabricated by the deep RIE process of an SOI wafer. The fabricated microaccelerometer reduces the electrical noise at the level of $2.4{\mu}g/\sqrt{Hz}$ for the sense voltage of l6.5V, which is 10.1 times smaller than the electrical noise level of $24.3{\mu}g/\sqrt{Hz}$ at 0.9V. For the sense voltage higher than 2V, the electrical noise level of the microaccelerometer became smaller than the constant mechanical noise level of $11{\mu}g/\sqrt{Hz}$. Total noise level, including the electrical noise and the mechanical noise, has been measured as $9{\mu}g/\sqrt{Hz}$ for the sense voltage of 16.5V, which is 3.2 times smaller than the total noise of $28.6{\mu}g/\sqrt{Hz}$ for the sense voltage of 0.9V. The self force-balancing effect results in the increased stiffness of 1.98 N/m at the sense voltage of 17.8V, compared to the stiffness of 1.35 N/m at 0V, thereby generating the additional stiffness at the rate of $0.002N/m/V^{2}$.

  • PDF

유연 촉각 센서를 이용한 로봇 그리퍼의 미끄러짐 감지 (Slip Detection of Robot Gripper with Flexible Tactile Sensor)

  • 서지원;이주경;이석;이경창
    • 한국정밀공학회지
    • /
    • 제31권2호
    • /
    • pp.157-164
    • /
    • 2014
  • In this paper, we design a gripping force control system using tactile sensor to prevent slip when gripper tries to grasp and lift an object. We use a flexible tactile sensor for measuring uniplanar pressure on gripper's finger and develop an algorithm to detect the onset of slip using the sensor output. We also use a flexible pressure sensor to measure the normal force. In addition, various signal processing techniques are used to reduce noise included in the sensor output. A 3-finger gripper is used to grasp and lift up a cylindrical object. The tactile sensor is attached on one of fingers, and sends output signals to detect slip. Whenever the sensor signal is similar to the slip pattern, gripper force is increased. In conclusion, this research shows that slip can be detected using the tactile sensor and we can control gripping force to eliminate slip between gripper and object.

3차원 영상처리 기술을 이용한 Grasp planning의 최적화 (The Optimal Grasp Planning by Using a 3-D Computer Vision Technique)

  • 이현기;김성환;최상균;이상룡
    • 한국정밀공학회지
    • /
    • 제19권11호
    • /
    • pp.54-64
    • /
    • 2002
  • This paper deals with the problem of synthesis of stable and optimal grasps with unknown objects by 3-finger hand. Previous robot grasp research has mainly analyzed with either unknown objects 2-dimensionally by vision sensor or known objects, such as cylindrical objects, 3-dimensionally. As extending the previous work, in this study we propose an algorithm to analyze grasp of unknown objects 3-dimensionally by using vision sensor. This is archived by two steps. The first step is to make a 3-dimensional geometrical model for unknown objects by using stereo matching. The second step is to find the optimal grasping points. In this step, we choose the 3-finger hand which has the characteristic of multi-finger hand and is easy to model. To find the optimal grasping points, genetic algorithm is employed and objective function minimizes the admissible force of finger tip applied to the objects. The algorithm is verified by computer simulation by which optimal grasping points of known objects with different angle are checked.

분산 구동 메커니즘을 내장한 로봇 핑거의 정밀 자세 제어기 설계 (Precise Control Law Design of Robot Finger Embedding Distributed Actuation Mechanism)

  • 신영준;김경수;김수현
    • 제어로봇시스템학회논문지
    • /
    • 제16권9호
    • /
    • pp.846-851
    • /
    • 2010
  • In this paper, we newly propose a novel control strategy of a three joints-robot finger for the purpose of artificial hands. The robot finger is specifically modeled by using a 3D CAD program (CATIA), considering human fingers, and then the proposed control method is verified through the dynamic simulation tool (Simulink and Recurdyn R2). Each slider is individually controlled to be located at the optimal positions where the maximal joint torque can be generated. To prove the effectiveness of the proposed control method, we devise two cases for the reference position of sliders. By comparing the control performance of two cases, the validity of the proposed control method will be verified.

A Deformation Model of a Bag-Finger Skirt and the Motion Response of an ACV in Waves

  • Lee, Gyeong-Joong;Rhee, Key-Pyo
    • Selected Papers of The Society of Naval Architects of Korea
    • /
    • 제2권1호
    • /
    • pp.29-46
    • /
    • 1994
  • In this paper, the effect of a skirt deformation on the responses of an Air Cushion Vehicle in waves is investigated. The air in the bag and plenum chamber is assumed to be compressible and to have a uniform pressure distribution in each volume. The free surface deformation is determined in the framework of a linear potential theory by replacing the cushion pressure with the pressure patch which is oscillating and translating uniformly. And the bag-finger skirt assumed to be deformed due to the pressure disturbance while its surface area remained constant. The restoring force and moment due to the deformation of bag-finger skirt from equilibrium shape is incorporated with the equations of heave and pitch motions. The numerical results of motion responses due to various ratios of the bag and cushion pressure or bag-to-finger depth ratios are shown.

  • PDF

고감지전압 및 가지전극을 이용한 고정도 정전용량형 미소가속도계 (High-resolution Capacitive Microaccelerometers using Branched finger Electrodes with High-Amplitude Sense Voltage)

  • 한기호;조영호
    • 대한기계학회논문집A
    • /
    • 제28권1호
    • /
    • pp.1-10
    • /
    • 2004
  • This paper presents a navigation garde capacitive microaccelerometer, whose low-noise high-resolution detection capability is achieved by a new electrode design based on a high-amplitude anti-phase sense voltage. We reduce the mechanical noise of the microaccelerometer to the level of 5.5$\mu\textrm{g}$/(equation omitted) by increasing the proof-mass based on deep RIE process of an SOI wafer. We reduce the electrical noise as low as 0.6$\mu\textrm{g}$/(equation omitted) by using an anti-phase high-amplitude square-wave sense voltage of 19V. The nonlinearity problem caused by the high-amplitude sense voltage is solved by a new electrode design of branched finger type. Combined use of the branched finger electrode and high-amplitude sense voltage generates self force-balancing effects, resulting in an 140% increase of the bandwidth from 726㎐ to 1,734㎐. For a fixed sense voltage of 10V, the total noise is measured as 2.6$\mu\textrm{g}$/(equation omitted) at the air pressure of 3.9torr, which is the 51% of the total noise of 5.1$\mu\textrm{g}$/(equation omitted) at the atmospheric pressure. From the excitation test using 1g, 10㎐ sinusoidal acceleration, the signal-to-noise ratio of the fabricated microaccelerometer is measured as 105㏈, which is equivalent to the noise level of 5.7$\mu\textrm{g}$/(equation omitted). The sensitivity and linearity of the branched finger capacitive microaccelerometer are measured as 0.638V/g and 0.044%, respectively.

접촉력 및 미끄러짐을 감지 가능한 촉각 센서의 개발 (Development of Tactile Sensor for Detecting Contact Force and Slip)

  • 최병준;강성철;최혁렬
    • 대한기계학회논문집A
    • /
    • 제30권4호
    • /
    • pp.364-372
    • /
    • 2006
  • In this paper, we present a finger tip tactile sensor which can detect contact normal force as well as slip. The sensor is made up of two different materials, such as polyvinylidene fluoride (PVDF) known as piezoelectric polymer, and pressure variable resistor ink. In order to detect slip on the surface of the object, two PVDF strips are arranged along the normal direction in the robot finger tip and the thumb tip. The surface electrode of the PVDF strip is fabricated using silk-screening technique with silver paste. Also a thin flexible force sensor is fabricated in the form of a matrix using pressure variable resistor ink in order to sense the static force. The developed tactile sensor is physically flexible and it can be deformed three-dimensionally to any shape so that it can be placed on anywhere on the curved surface. In addition, a tactile sensing system is developed, which includes miniaturized charge amplifier to amplify the small signal from the sensor, and the fast signal processing unit. The sensor system is evaluated experimentally and its effectiveness is validated.

Development of Fingertip Tactile Sensor for Detecting Normal Force and Slip

  • Choi, Byung-June;Kang, Sung-Chul;Choi, Hyouk-Ryeol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1808-1813
    • /
    • 2005
  • In this paper, we present the finger tip tactile sensor which can detect contact normal force as well as slip. The developed sensor is made of two different materials, such as polyvinylidene fluoride(PVDF) that is known as piezoelectric polymer and pressure variable resistor ink. In order to detect slip to surface of object, a PVDF strip is arranged along the normal direction in the robot finger tip and the thumb tip. The surface electrode of the PVDF strip is fabricated using silk-screening technique with silver paste. Also a thin flexible force sensor is fabricated in the form of a matrix using pressure variable resistor ink in order to sense the static force. The developed tactile sensor is physically flexible and it can be deformed three-dimensionally to any shape so that it can be placed on anywhere on the curved surface. In addition, we developed a tactile sensing system by miniaturizing the charge amplifier, in order to amplify the small signal from the sensor, and the fast signal processing unit. The sensor system is evaluated experimentally and its effectiveness is validated.

  • PDF