• 제목/요약/키워드: fin effectiveness

검색결과 53건 처리시간 0.027초

방향타를 이용한 선박 횡동요 제어계 설계에 관한 연구 (A Study on Rudder-Roll Stabilization System Design for Ship)

  • 김영복
    • 대한기계학회논문집A
    • /
    • 제26권2호
    • /
    • pp.329-339
    • /
    • 2002
  • In ship operation the consequency of roll motions can seriously degrade the performance of mechanical and personnel effectiveness. So many studies for the roll stabilization control system design have been performed and very good results have been achieved. In many studies, the stabilizing fins are used. Recently rudders, which have been extensively modified, have been used to exclusively to stabilize the roll. This paper examines the two-degree-of-freedom servosystem design technique to synthesize the yaw control system which achieves the course keeping object of the ship and the H$_{\infty}$ control approach to suppress the roll motion, respectively.

내부 요소 연결 매개법을 활용한 3 차원 냉각핀의 위상 최적설계 (The Topology Optimization of Three-dimensional Cooling Fins by the Internal Element Connectivity Parameterization Method)

  • 유성민;김윤영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.360-365
    • /
    • 2007
  • This work is concerned with the topology optimization of three-dimensional cooling fins or heat sinks. Motivated by earlier success of the Internal Element Connectivity Method (I-ECP) method in two-dimensional problems, the extension of I-ECP to three-dimensional problems is carried out. The main efforts were made to maintain the numerical trouble-free characteristics of I-ECP for full three-dimensional problems; a serious numerical problem appearing in thermal topology optimization is erroneous temperature undershooting. The effectiveness of the present implementation was checked through the design optimization of three-dimensional fins.

  • PDF

Mixed Control with Aerodynamic Fin and Side Thruster Applied to Air Defense Missile

  • Chanho Song;Kim, Yoon-Sik
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.148.4-148
    • /
    • 2001
  • This paper shows an autopilot design example with simulation results for a medium range surface-to-air missile used to intercept fast maneuver targets. The missile is assumed to use both aerodynamic fins and side thrusters to achieve fast time response. The steady-state maneuver capability of the missile is assumed to be enough at high altitude to engage usual maneuvering targets. Side thruster is used to get an extremely rapid acceleration response at high altitude where the missile´s aerodynamic control effectiveness is weak. The strategy of control design is firstly to employ side thrusters to achieve a rapid response and then to hand-over the control to the aerodynamic fins to maintain the desired acceleration command in the steady state ...

  • PDF

Numerical Analysis of Laminar Natural Convection Heat Transfer around Two Vertical Fins by a Spectral Finite Difference Method

  • Haehwan SONG;MOCHIMARU Yoshihiro
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2003년도 The Fifth Asian Computational Fluid Dynamics Conference
    • /
    • pp.56-57
    • /
    • 2003
  • A numerical solution is presented for the natural convection heat transfer from two vertical fins using a spectral finite difference method. Virtual distant boundary conditions for two bodies that are compatible with plume behavior and with an overall continuity condition are introduced. A boundary-fitted coordinate system is formed. Streamlines, isotherms, mean Nusselt numbers and drag & lift coefficients are presented for a variety of dimensionless parameters such as a Grashof number and a Prandtl number at a steady-state. Extensive effectiveness of a spectral finite difference method was established.

  • PDF

차량 연비개선을 위한 자동변속기유 열교환기에 대한 실험적 연구 (Experimental Study on Auto-Transmission Fluid Heat Exchanger for Improving Vehicle Fuel Efficiency)

  • 장충만;이용규;강병동;유재석;이종화;김현정;김동권
    • 대한기계학회논문집B
    • /
    • 제35권9호
    • /
    • pp.947-954
    • /
    • 2011
  • 차량에서 구동계의 의한 손실은 전체 연료 소비 손실에서 약 4%를 차지하며 그 중에서도 자동변속기는 구동계 손실에 큰 영향을 끼친다. ATF W/C 열교환기는 근래에 관심이 높아지고 있는 부품인데, 자동변속기 윤활유의 온도를 적정한 상태로 유지시켜 줌으로서 연비 개선 효과를 얻을 수 있다. 본 연구에서는 ATF W/C 열교환기 단품 특성을 실험적으로 파악하고, ATF W/C 열교환기가 실제 차에 장착되었을 때의 연비 개선 효과를 살펴보았다. 본 연구에서는 실험을 통하여 ATF 와 냉각수의 온도와 유량에 대한 유용도를 파악하고 유용도를 예측하기 위한 상관식을 도출하였다. MATLAB의 Simulink 프로그램을 통하여 실험의 결과를 바탕으로 ATF W/C 열교환기 유무에 따른 연료 소모량을 비교 하여 연비 개선 효과를 분석하였다. 그 결과 ATF W/C 열교환기가 장착된 자동차는 0.992% 연비 개선 효과가 나타났다.

착상을 고려한 극저온 질소-대기 열교환기의 해석 (Analysis of a Cryogenic Nitrogen-Ambient Air Heat Exchanger Including Frost Formation)

  • 최권일;장호명
    • 설비공학논문집
    • /
    • 제12권9호
    • /
    • pp.825-834
    • /
    • 2000
  • A heat exchanger analysis is performed to investigate the heating characteristics of cryogenic nitrogen by ambient air for the purpose of cryogenic automotive propulsion. The heat exchanger is a concentric triple-passage for supercritical nitrogen, and the radial fins are attached on the outermost tube for the crossflow of ambient air. The temperature distribution is calculated for the nitrogen along the passage, including the real gas properties of nitrogen, the fluid convections and the conductions through the tube walls and the fins. Since the wall temperature of the outer (ambient side) tube is very low in most cases, a heavy frost can be formed on the surface, affecting the heat exchange performance. By the method of the similarity between the heat and the mass transfer of moist air, the frost growth and the time-dependent effectiveness of the heat exchanger are calculated for various operating conditions. It is concluded that the frost formation can augment the heating of nitrogen during the initial period because of the latent heat, then gradually degrades the heat exchange because of the increased thermal resistance. Practical design issues are discussed for the flow rate of nitrogen, the velocity and humidity of ambient air, and the sizes of the fin.

  • PDF

톱니형휜이 부착된 2중 열교환관을 이용한 엔진 배열회수기에 관한 실험적 연구 (An Experimental Study on the Heat Exchanger for the Engine Waste Heat Recovery Using Serrated Fins and Bayonet Tube)

  • 양태진;김종수;임용빈
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권6호
    • /
    • pp.685-691
    • /
    • 2005
  • In this study, high performance waste heat recovery heat exchanger was developed using the bayonet tube with spiral serrated fins. Especially, heat exchanger of the bayonet tube type was operated well because of double water passes mechanism and characteristics. A cooling water Passes down inner tubes to thimble-form tubes, then flows back up as it boils. The heat exchanger of bayonet tube type was composed of steel tube with 7channels$(I.D_1\;14mm.\;I.D_2\;31.6mm)$ and spiral serrated fins. The performance tests were conducted under the following conditions A cooling water flow rate was 273kg/h and engine l·pm was varied from 750rpm to 3500 rpm. From the experimental result. waste heat recovery was 9.21kW when engine rpm was 3500. and pressure drop was $15\~260mmHg/m^3$ The effectiveness of heat exchanger was about /$0.7\~0.9$. The performance of heat exchanger was evaluated by using the $\varepsilon-NTU$ method. In the study the NTU of the heat exchanger was $1.57\~2.33$.

음란 유해사이트 차단을 위한 음향 신호 처리 및 분석 (Acoustic Signal Processing & Analysis for Blocking Internet Harmful Phonographic Sites)

  • 조동욱;김지영
    • 한국콘텐츠학회논문지
    • /
    • 제4권2호
    • /
    • pp.1-6
    • /
    • 2004
  • 본 논문에서는 음란 유해 사이트에서 성행위 묘사시 발생하는 음향 신호를 처리하고 분석하여 표준 패턴 음향신호와 어느 정도 일치하는지 상관 계수를 계산함으로써 내용에 기반하여 음란콘텐츠를 차단하는 방법에 대해 제안하고자 한다. 기존의 음란 유해 사이트 차단 방법은 목록기반과 단어기반에 의한 방법이어서 새로이 생겨나는 음란사이트가 차단이 안되거나 음란사이트 운영자가 교묘히 음란 단어를 변경함으로써 단어 기반으로 음란사이트가 차단이 안되는 문제가 존재했었다. 이를 해결하기 위해 본 논문에서는 콘텐츠기반의 차단법을 다루고자 한다. 특히 본 논문은 음란물의 콘텐츠(내용)에 기반한 전체 시스템중 음향 신호처리에 기반 한 음란 사이트 차단법에 대해 다루고자 한다. 끝으로 실험에 의해 제안한 방법의 유용성을 입증하고자 한다.

  • PDF

Fuzzy Distance Estimation for a Fish Robot

  • Shin, Daejung;Na, Seung-You;Kim, Jin-Young
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제5권4호
    • /
    • pp.316-321
    • /
    • 2005
  • We designed and implemented fish robots for various purposes such as autonomous navigation, maneuverability control, posture balancing and improvement of quick turns in a tank of 120 X 120 X 180cm size. Typically, fish robots have 30-50 X 15-25 X 10-20cm dimensions; length, width and height, respectively. It is essential to have the ability of quick and smooth turning to avoid collision with obstacles or walls of the water pool at a close distance. Infrared distance sensors are used to detect obstacles, magneto-resistive sensors are used to read direction information, and a two-axis accelerometer is mounted to compensate output of direction sensors. Because of the swing action of its head due to the tail fin movement, the outputs of an infrared distance sensor contain a huge amount of noise around true distances. With the information from accelerometers and e-compass, much improved distance data can be obtained by fuzzy logic based estimation. Successful swimming and smooth turns without collision demonstrated the effectiveness of the distance estimation.

수평형 재생증발식 냉방기의 성능시험 (Performance Test for a Horizontal Regenerative Evaporative Cooler)

  • 송귀은;이대영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.621-626
    • /
    • 2006
  • Regenerative evaporative cooling is known as an environment-friendly and energy efficient cooling method. A regenerative evaporative cooler (REC) consisting of dry and wet channels is able to cool down the air stream below the inlet wet-bulb temperature. In the regenerative evaporative cooler, the cooling effect is achieved by redirecting a portion of the air flown out of the dry channel into the wet channel and spraying water onto the redirected air. In this study, a horizontal regenerative cooler is considered. In the horizontal regenerative cooler, the flow direction of evaporating water has a right angle to the flow direction of supply air. This difference was investigated with visualization technique and simplified 2-module performance test was done in a thermo-environment chamber. Optimum design configuration is changed due to the wet channel which are easily fully covered with evaporating water and block the air flow inside the channel. Applying the optimized fin configuration design with the highly wetting surface treatment, a regenerative evaporative cooler was fabricated and tested to Identify the cooling performance improvement and operation characteristics. From the experimental results at the intake condition of $32^{\circ}C$ and 50% RH, the supply temperature was measured to be around $23.4^{\circ}C$. The cooling effectiveness based on the inlet dewpoint temperature was evaluated 73% which is almost close to the design expectation.

  • PDF