• Title/Summary/Keyword: filtration performance

Search Result 375, Processing Time 0.031 seconds

Evaluation of Point-Of-Use (POU) Filters Performance in Chemical Mechanical Polishing Slurry Supply System (슬러리 공급 시스템을 이용한 화학적 기계적 연마 공정에서의 POU 필터의 성능 평가)

  • Jang, Sunjae;Kim, Hojoong;Jin, Hongi;Nam, Miyeon;Kulkarni, Atul;Kim, Taesung
    • Particle and aerosol research
    • /
    • v.9 no.4
    • /
    • pp.261-269
    • /
    • 2013
  • The chemical mechanical polishing (CMP) process is widely used in semiconductor manufacturing process for planarization of various materials and structures. Point-of-use (POU) filters are used in most of the CMP processes in order to reduce the unwanted micro-scratches which may result in defects. The performance of the POU filter is depends on type and size of the abrasives used during cleaning process. For this reason, there is a need to evaluate POU filters for their filtration efficiency (FE) with different types of abrasives. In this study, we developed filter test system to evaluate the FE of POU using ceria and silica abrasives (slurry). The POU filter is roll type capsule filter with retention size of 0.2 ${\mu}m$. Two POU filters of different make are evaluated for FE. We observed that both POU filters show similar filtration efficiency for silica and ceria slurry. Results reveal that the ceria slurry and the colloidal silica particle are removed not only by mechanical way but also hydrodynamic and electrostatic interaction way.

Studies of Purification and Characterization of Epidermal Growth Factor from Human Colostrum (인유 중의 Epidermal Growth Factor 분리 및 특성에 관한 연구)

  • 신영하;양희진;양동훈;이수원
    • Food Science of Animal Resources
    • /
    • v.23 no.2
    • /
    • pp.155-160
    • /
    • 2003
  • The purpose of this study was to purify epidermal growth factor(EGF) as growth factor from human colostrum. The effects of purified EGF fraction were directly related to the growth of cells. Results were as follows; After eliminated fat from colostrum, skim milk was obtained. We obtained the EGF fraction by performing ultrafiltration and gel filtration, and then were convicted by SDS-PAGE. The result of analysis of purified EGF fraction by high performance liquid chromatography(HPLC) was shown a peak at 31.185 min period. And it was similar with standard EGF that was shown a peak at 31.545 min. 10 ng of EGF was contained in 10 mg/mL through immunoassay to measure EGF content from isolated fraction. After SDS-PAGE, isolation degree of purified fraction was convicted through western blotting. BALB/3T3 cell was the most effectively stimulated and proliferated at 1 mg/mL concentration of the purified EGF fraction and percentage of cell proliferation was about 95%. In the case of IEC-6 cell, that was about 71%.

Fouling analysis and biomass distribution on a membrane bioreactor under low ratio COD/N

  • Gasmi, Aicha;Heran, Marc;Hannachi, Ahmed;Grasmick, Alain
    • Membrane and Water Treatment
    • /
    • v.6 no.4
    • /
    • pp.263-276
    • /
    • 2015
  • This paper deals with the influence of chemical oxygen demand to nitrogen ratio ((COD/N) ratio) on the performance of an membrane bioreactor. We aim at establishing relations between COD/N ratio, organisms' distribution and sludge properties (specific resistance to filtration (SRF) and membrane fouling). It is also essential to define new criteria to characterize the autotrophic microorganisms, as the measurements of apparent removal rates of ammonium seem irrelevant to characterize their specific activity. Two experiments (A and B) have been carried on a 30 L lab scale membrane bioreactor with low COD/N ratio (2.3 and 1.5). The obtained results clearly indicate the role of the COD/N ratio on the biomass distribution and performance of the membrane bioreactor. New specific criteria for characterising the autotrophic microorganisms activity, is also defined as the ratio of maximum ammonium rate to the specific oxygen uptake rate in the endogenous state for autotrophic bacteria which seem to be constant whatever the operating conditions are. They are about 24.5 to 23.8 $gN-NH_4{^+}/gO_2$, for run A and B, respectively. Moreover, the filterability of the biological suspension appear significantly lower, specific resistance to filtration and membrane fouling rate are less than $10^{14}m^{-2}$ and $0.07\;10^{12}m^{-1}.d^{-1}$ respectively, than in conventional MBR confirming the adv < antage of the membrane bioreactor functioning under low COD/N ratio.

Manufacturing and Filtration Performance of Microfiltration Metal Membrane Using Rolling Process (압연공정을 이용한 금속 정밀여과막의 제조 및 여과특성)

  • Kim, Jong-Oh;Min, Seok-Hong;Jung, Jong-Tae
    • Membrane Journal
    • /
    • v.17 no.3
    • /
    • pp.174-183
    • /
    • 2007
  • The manufacturing process of metal membrane made of only metal mesh and both metal mesh and powder with using rolling process have been studied. In the rolling of metal mesh, selected metal meshes were rolled with the reduction ratio of 10%, 20%, and 30%, respectively. Such rolling process resulted in the decrease of mesh pore size through reduction the cross sectional area of mesh and changing the diameter of mesh wires. Also, it enhanced the filtration ratio of rolled mesh which is almost same as the filtration ratio of upper grade unrolled mesh and the reliability of membrane by making pore size distribution become more uniform. In fabricating metal powder layer onto metal mesh, using PVA(polyvinyl alcohol) as a binder of powder, drying the metal powder layer at $100^{\circ}C$ for 1 hr, and sintering it at $1,000^{\circ}C$ for 3 hr in vacuum were to be optimum conditions for obtaining good quality of metal powder layer on metal mesh with high pore density but no crack. With additional rolling of metal powder layer on metal mesh with 30% reduction before sintering, metal membrane which filtration ratio is about $0.7{\mu}m$ has been successfully manufactured.

Purification and Characterization of Polyphenol Oxidase from Lotus Root (Nelumbo nucifera G.) (연근의 polyphenol oxidase 정제 및 특성조사)

  • Moon, Sang-Mi;Kim, Hyun-Jin;Ham, Kyung-Sik
    • Korean Journal of Food Science and Technology
    • /
    • v.35 no.5
    • /
    • pp.791-796
    • /
    • 2003
  • Polyphenol oxidase isoforms were purified from the lotus roots using 50% acetone precipitation, conventional chromatographies of Q-Sepharose and hydrophobic interaction, and high performance liquid chromatographies of Mono-Q and Superdex 75 gel-filtration. Molecular mass of a purified PPO isoform (LPIII-2) was determined to be 56 kDa using gel-filtration chromatography. The active form of LPIII-2 appeared to bea heterodimer, as purified LPIII-2 on SDS-PAGE gel showed two bands that were determined to be 28 kDa and 26 kDa. To further characterize PPO, partially purified PPO isoforms (LP-II, LP-III) were obtained from Q-Sepharose anion-exchange chromatography. In substrate specificity, the partially purified PPO isoform LP-II showed a high affinity to catechol, while LP-III showed a high affinity to pyrogallol. The optimum pH of LP-II and LP-III was pH 7.0. Interestingly, the partially purified PPO isoforms showed high activities at low temperatures $(0{\sim}5^{\circ}C)$, and as temperatures rose, the activities decreased. Both PPO isoforms were stable at $40^{\circ}C$ and were inactivated by incubation at $60^{\circ}C$ for 40 min.

The Study on Optimum Operation Conditions of Ceramic MF Membrane Process in Y Water Treatment Plant (Y 정수장 세라믹막 여과공정 최적 운영인자 평가)

  • You, Sang-Jun;Ahn, Hyo-Won;Park, Sung-Han;Lim, Jae-Lim;Hong, Sung-Chul;Yi, Pyong-In
    • Membrane Journal
    • /
    • v.24 no.3
    • /
    • pp.201-212
    • /
    • 2014
  • This study was performed to discover the optimum operation conditions for the advanced water treatment using the ceramic membrane, introduced the first in the nation at the Y water treatment plant (WTP). The result of investigation to find the optimum operation conditions which can continue preserving the filtration performance as well as satisfying both the economics and the water quality is as follows. In the ordinary water quality condition of the Y WTP, the optimum filtration time(the backwash period), which can minimize the production of backwash waste and preserve the membrane performance was examined to be 4.0 hours on basis of institution capacity ($16,000m^3/day$). Examining the recovery rate of TMP from the chemical cleaning (CIP) discovered that the inorganic contaminants, which cause membrane fouling, such as iron, manganese, aluminum, were removed through the acidic cleaning using citric acid, whereas the membrane recovery rate was found to be low. But, on the other hand, the TMP was recovered to the initial value from the alkali cleaning using the NaOCl. Therefore, the main contaminant causing the fouling was determined to be hydrophilic organic compound( biopolymer). The membrane recovery rate is highly influenced by the temperature of the cleaning chemical. That is, the rate increased with increasing temperature.

A study on the disinfection performance of indoor microorganism using energy consumption analysis for indoor bio-safety (건물 재실자의 미생물 안전을 위한 면역건물 기술의 에너지 사용 연구)

  • Choi, Sang-Gon
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.4
    • /
    • pp.111-118
    • /
    • 2009
  • In this study the real situation of apartment house in seoul is reproduced with multi-zone modeling program CONTAM2.4. This model include disinfection system which is consist of dilution, filtration, UVGI(ultra violet germicidal irradiation). It's energy consumption was also analyzed through the linked model of CONTAM and TRNSYS according to the combination of components. The comparison of total energy consumption through energy analysis revealed that adjusting the air change rate of the UVGI air sterilizer to maintain the same indoor microbe removal capability was more advantageous in terms of energy consumption.

Development of composite filter with high performance meltblown non-woven (고성능 멜트블로운 부직포 복합필터 개발)

  • Lee Jae-Dal;Hong Young-Ki;Bae Kie-Seo
    • Textile Coloration and Finishing
    • /
    • v.17 no.2 s.81
    • /
    • pp.40-45
    • /
    • 2005
  • Electret filter is good enough to protect health and environment from air pollution. The reason why is gathering particles not only by mechanical mechanism but also by electrostatic attraction. Especially this filter is shown lower pressure drop than general mechanical filters as glass fiber. For making electret filter media using polypropylene meltblown(M/B) nonwoven, the nonwoven is charged with corona which was supplied high voltage DC, AC, and pulse with DC power. The electret filter media is tested with $0.3{\mu}m$ sodium chloride and dioctyl phthalate(DOP) aerosol. Results revealed that filtration performance of electret filter media increased as corona was applied with higher voltage and with AC power rather than DC, and fiber diameter was fine and uniform.

Performance and characterization of PEG400 modified PVC ultrafiltration membrane

  • Aryanti, P.T.P.;Yustiana, R.;Purnama, R.E.D.;Wenten, I.G.
    • Membrane and Water Treatment
    • /
    • v.6 no.5
    • /
    • pp.379-392
    • /
    • 2015
  • Polyvinyl chloride (PVC) ultrafiltration membrane was prepared by blending 12 wt.% of PVC in N, N-dimethylacetimide (DMAc) with polyethylene glycol 400 (PEG400) as an additive. The influence of PEG400 concentration on the PVC membrane morphology, permeability, fouling and rejection were investigated. Fouling and rejection of the PVC membrane were characterized by dextran T-100 filtration. The results showed that membrane water flux was increased up to $682Lm^{-2}h^{-1}$ when 28 wt.% of PEG400 was added into the PVC membrane solution. The best membrane performance with a low fouling and a high selectivity was achieved by adding 12 wt.% concentration of PEG400, which resulted in 90% rejection of dextran and 90% of flux recovery ratio. At further addition of PEG400 concentration, irreversible fouling was starting to increase. A 90% of irreversible fouling was formed in the PVC membrane when more than 22 wt.% of PEG400 is added.

RESEARCH PAPERS : REMOVAL EFFICIENCY OF THE POLLUTANTS BY MULTILAYERED METAL TREATED CARBON FILTER

  • Oh, Won-Chun;Lee, Ho-Jin;Bae, Jang-Soon
    • Environmental Engineering Research
    • /
    • v.9 no.5
    • /
    • pp.193-200
    • /
    • 2004
  • A study of the treatment of piggery wastes using a multilayered metal-activated carbon system followed by carbon bed filtration was carried out at bench scale. From the physicochemical properties obtained from samples treated with aqueous solutions containing metallic ions such as Ag$^+$, Cu$^{2+}$, Na$^{-}$, K$^+$ and Mn$^{2+}$, main inspections are subjected to isothem shape, pore distribution with micropore, SEM and EDX. Multilayered metal-activated carbons were contacted to waste water to inwestigate the simultaneous catalytic effect for the COD, BOD, T-N and T-P removal. From these removal performance was achieved. The high efficiency of the multilayered metal-activated carbon bed, satisfactory removal performance was achieved. The high efficiency of the multilayered metal-activated carbon bed was derermined by the properties of this material for trapping, catalytic effect and adsorption of organic solid particles.