• Title/Summary/Keyword: filtration flux

Search Result 265, Processing Time 0.026 seconds

Removal of Aqueous Calcium Ion by Micellar Enhanced Ceramic Membranes Adding Surfactant (계면활성제를 첨가한 미셀 형성 세라믹 분리막에 의한 칼슘이온 제거)

  • Park, Jin-Yong;Park, Bo-Reum
    • Membrane Journal
    • /
    • v.18 no.1
    • /
    • pp.7-25
    • /
    • 2008
  • Sodium dodecyl sulfate, which was anionic surfactant, at a concentration higher than its critical micellar concentration was added to calcium solution for forming micelles. Then aggregates were formed by adsorption or binding of calcium ions on the surface of micelles, and gathering between them, and then rejected by two kinds of ceramic membranes to remove calcium ions. As result, rejection rates of calcium were higher than 99.98%. And in our experimental range the higher TMP trended to increase the resistance of membrane fouling ($R_f$), total permeate volume ($V_T$), dimensionless permeate flux ($J/J_o$) and permeate flux (J) because TMP was driving force. And we investigated effects of $N_2$-back-flushing time and filtration time, that was back-flushing period, during periodic $N_2$-back-flushing on ceramic membranes. As result, optimal BTs for NCMT-623l ($0.07{\mu}m$ pore size) and NCMT-7231 membrane ($0.10{\mu}m$) were 10 sec and 15 sec, respectively. Also, optimal FT was 5 min for both membranes, and the frequent $N_2$-back-flushing could decrease membrane fouling effectively. Then, the optimal conditions resulting from our experiments for synthetic calcium solution were applied to groundwater using as washing process of soymilk package. As result, rejection rates of calcium were higher than 99.98%.

Recycling of Acidic Etching Waste Solution Containing Heavy Metals by Nanofiltration (II) : Dead-end Nanofiltration of PCB Etching Waste Solution Containing Copper Ion (나노여과에 의한 중금속 함유 산성 폐에칭액의 재생(II) : 구리이온을 함유한 PCB 폐에칭액의 Dead-end 나노여과)

  • Nam, Sang-Won;Jang, Kyung-Sun;Youm, Kyung-Ho
    • Membrane Journal
    • /
    • v.23 no.1
    • /
    • pp.92-99
    • /
    • 2013
  • In this study the nanofiltration (NF) membrane treatment of a sulfuric acid waste solutions containing copper ion ($Cu^{+2}$) discharging from the etching processes of the printed circuit board (PCB) manufacturing industry has been studied for the recycling of acid etching solution. SelRO MPS-34 4040 NF membrane from Koch company was tested to obtain the basic NF data for recycling of etching solution and separation efficiency (total rejection) of copper ion. NF experiments were carried out with a dead-end membrane filtration laboratory system. The pure water flux was increased with the increasing storage time in sulfuric acid solution and lowering pH of acid solution because of the enhancement of NF membrane damage by sulfuric acid. The permeate flux of acid solution was decreased with the increasing copper ion concentration. Total rejection of copper ion was decreased with the increasing storage time in sulfuric acid solution and copper ion concentration, and lowering the pH of acid solution. The total rejection of copper ion was decreased from initial 37% to 15% minimum value.

The Treatment of Heavy Metal Hydroxides by Crossflow-Microfiltration (정밀여과에 의한 중금속수산화물의 처리)

  • Yoo, Kun-Woo;Seo, Hyung-Joon
    • Clean Technology
    • /
    • v.8 no.3
    • /
    • pp.151-165
    • /
    • 2002
  • In the treatment of the wastewater containing metals($Cu^{2+}$, $Zn^{2+}$, $Ni^{2+}$, $Cr^{3+}$) by using batch precipitation and flocculation followed by membrane filtration, permeate flux and removal efficiency were investigated according to by the effect of pH and coagulants, and the type of membranes used and pore size. It was found that it is most effective to use $0.45{\mu}m$-polysulfone membrane and coagulant(PAC) at the conditions of the pH of 10.0~10.5 for the case of copper containing wastewater, $0.1{\mu}m$-PVDF membrane and coagulant(PAC) at the conditions of the pH of 10.0~10.5 for the case of zinc containing wastewater, $0.1{\mu}m$-PVDF membrane and coagulant at the conditions of the pH of 11.0~11.5 for the case of nickel containing wastewater, $0.2{\mu}m$ membrane and coagulant at the conditions of the pH of 8.0~8.5 for the case of chromic containing wastewater, and $0.2{\mu}m{\sim}0.45{\mu}m$ membrane and coagulant at the conditions of the pH of 11.0~11.5 for the case mixture wastewater. The permeate flux could higher as to be used coagulants except for the case of copper containing wastewater.

  • PDF

A Pilot Study for Microfiltration of Alcohol Stillage Condensate and Permeate Recycle to Fermentation Broth (알코홀 증류폐액의 Pilot Scale 정밀여과와 여과액의 발효 재활용에 대한 연구)

  • 김영범;이기세;남궁견;김종현
    • KSBB Journal
    • /
    • v.16 no.4
    • /
    • pp.403-408
    • /
    • 2001
  • Distillation condensate generated from downstream processing of microbial alcohol fermentation imposes a serious burden to biological wastewater treatment or anaerobic digestion due to its high contents of SS (suspended solids) and TN (total nitrogen), A pilot scale microfiltration of the stillage condensate with a stainless steel SCEPTER membrane of 0.1 ${\mu}$m pore size was carried out to remove SS which was mostly composed of microbial cell residue. A stable permeate flux was achieved when the decanter effluent containing 0.7% of SS was filtered under the conditions of X10 VCR (volume concentration ratio), 2.5 bar of TMP (transmembrane pressure), and 60$^{\circ}C$. When stillage condensate with 2.6% SS was treated directly with microfiltration, VCR below X3 was recommended for a long duration of filtration. The permeate and retentate obtained from microfiltration were recycled to make-up medium of fermentation. Adding permeate or retentate up to 30% of fermentation volume showed no distinguished undesirable influence during the course of alcohol fermentation. Although only slight improvements in the final amount of CO$_2$ evolution and alcohol content were observed, fermentation rate increased so that the required time to reach 450 L/ton of CO$_2$ evolution was shortened to 72% of that with normal media.

  • PDF

Microfiltration Characteristics for Emulsified Oil in Water (에멀젼형 오일 수용액에 관한 정밀여과 특성)

  • ;;;Fane, Anthony G.
    • Membrane Journal
    • /
    • v.8 no.4
    • /
    • pp.203-209
    • /
    • 1998
  • The cutting oil emulsion microfiltration was carried out on dead-end call and crossflow systems equipped with 0.22 $\mu$m GVHP Millipore and 0.2 m stainless steel Mott microfiltration membranes, respectivdy. The oil drop size in the emulsion was varied from 0.07 to 0.22 $\mu$m. Cake filtration(CFM) and standard pore blocking models(SPBM) were applied to predict the permeation flux. The permeation fluxes of 0.01 vol% oil emulsion followed CFM for dead-end system very well under the condition of 400 rpm and below 100 kPa. The SPBM was, however, suitable for the permeation flux at 400 rpm and above 150 kPa. The oil layer on the membrane surface was destroyed and reproduced repeatedly as operating pressure was suddenly changed from 60 to 200 kPa, and then returned to 60 kPa. Also, we estimated the critical entry pressure(CEP) which is changed from CFM to SPBM, and CEP for dead-end system was around 100 kPa. The CEP increased from around 100 to 150 kPa for the crossflow system as the oil concentration increased from 0.01 to 0.03 vol% when Reynolds number was 7080.

  • PDF

Effect of Periodic $N_2$-back-flushing in Paper wastewater Treatment using Carbon Ceramic Ultrafiltration and Microfiltration Membranes (탄소계 세라믹 한외 및 정밀 여과막으로 제지폐수 처리시 주기적 질소 역세척의 효과)

  • 황현정;박진용
    • Membrane Journal
    • /
    • v.12 no.1
    • /
    • pp.8-20
    • /
    • 2002
  • In this study using $N_2$-back flushing, which wwas not the general back-flushing method of membranes, the discharged wastewater from a paper plant was filtrated by 4 kinds of tubular carbon ceramic ultrafiltration membranes. We could in vestigate effects of $N_2$-back flushing period, transmembrane pressure (TMP)and flow rate and find optimal operating conditions. The $N_2$-back flushing time (BT) was fixed at 40 sec, filtration times (FT) were changed in 4~32 min, TNP in $1.0~3.0kg_f/cm^2$ the flow celocities in 0.53~1.09cm/s. The optimal conditions were discussed in the viewpoints of dimensionless permeate flux ($J/J_0$), toal permeate volume ($V_T$) and resistance of membrane fouling ($R_f$). Optimal back-flushing period was BT/FT=0.167 (FT=8 min ), in which more $V_T$ was obtained than that in BT/FT=0.083 (FT=4 min) which was the most friquent back-flushing condition. Then rising TMP should increase the driving force, and more $V_T$ could be accumulated. And rising flow rate should decrease membrane fouling increase permeate flux, and more $V_T$could be produced. Average rejection rates of pollutants were higher than 95% for turbidity and 45~83% for $COD_{Cr}$, but rejection rates of total dissolved solid (TDS) were lower than 10%.

Suction Pressures with respect to the Operational Modes using the Multi-bore Capillary Membranes in the Membrane Bioreactor (생물막 반응기내 다공성 중공사형막을 이용한 운전방식에 따른 흡입 압력)

  • Kim, Min Hyeong;Koo, Eeung Mo;Lee, Min Soo;Chung, Kun Yong
    • Membrane Journal
    • /
    • v.31 no.5
    • /
    • pp.343-350
    • /
    • 2021
  • In this study the suction pressure was measured with respect to operational time by submersing the multi-bore capillary membrane module in membrane bioreactor(MBR). The hexagonal shape capillary module which has the nominal pore size of 0.2 ㎛, outer diameter of 6.4 or 4.2 mm was immersed in MLSS 8,000 mg/L active sludge aqueous solution, and confirmed changes with respect to permeation flux and air flow rate. It was operated by the filtration/relaxation(FR), FR with backwashing(FR/BW), and sinusoidal flux continuous operation(SFCO) modes. The suction pressure for the SFCO and FR modes was lower at 30 and 50 L/m2·hr, respectively. In addition, the suction pressure of the module with a small outer diameter was relatively low. The suction pressure of a large outer diameter was greatly increased, but it could be reduced by more than 40% by backwashing.

Improving Physical Fouling Tolerance of PES Filtration Membranes by Using Double-layer Casting Methods (PES 여과막의 물리적 막오염 개선을 위한 기공 구조 개선 연구)

  • Chang-Hun Kim;Youngmin Yoo;In-Chul Kim;Seung-Eun Nam;Jung-Hyun Lee;Youngbin Baek;Young Hoon Cho
    • Membrane Journal
    • /
    • v.33 no.4
    • /
    • pp.191-200
    • /
    • 2023
  • Polyethersulfone (PES) is a widely employed membrane material for water and industrial purification applications owing to its hydrophilicity and ease of phase separation. However, PES membranes and filters prepared using the nonsolvent induced phase separation method often encounter significant flux decline due to pore clogging and cake layer formation on the dense membrane surfaces. Our investigation revealed that tight microfiltration or loose ultrafiltration membranes can be subject to physical fouling due to the formation of a dense skin layer on the bottom side caused by water intrusion to the gap between the shrank membrane and the substrate. To investigate the effect of the bottom surface porosity on membrane fouling, two membranes with the same selective layers but different sub-layer structures were prepared using single and double layer casting methods, respectively. The double layered PES membrane with highly porous bottom surface showed high flux and physical fouling tolerance compared to the pristine single layer membrane. This study highlights the importance of physical optimization of the membrane structure to prevent membrane fouling.

A Study on the Development of Standard Method of Total Deposition Sampling in Air Pollutants - Spatial Distribution of Total Deposition by the Filtration-Sampling Method - (대기오염 총침착물의 채취방법 표준화 개발에 관한 연구 -여과식 채취방법을 통한 총침착물의 공간분포 특성-)

  • 박정호;조인철;김찬훈;서정민
    • Journal of Environmental Science International
    • /
    • v.11 no.6
    • /
    • pp.489-496
    • /
    • 2002
  • The purpose of this study was to investigate spatial distributions of total deposition. A total number 79 samples were collected at 17 sampling sites from September 1999 to January 2000. Total (=wet+dry) atmospheric depositions were collected by filtered deposition sampler at sampling site (the Western Part of Kyongsangnam Province). In addition, the deposition of soluble and insoluble fraction was also investigated to find a suitable simplified collection method for a long-term monitoring of total deposition. The total depositions were measured soluble amount(mm/month), insoluble amount(kg/km$^2$/month), pH, conductivity(E.C.) and eight ionic components. The spatial distribution of deposition flux was to estimated by using a kringing analysis. The 17 sites mean fluxes of water soluble ionic components; SO$_4$$\^$2-/, Cl$\^$-/, NO$_3$$\^$-/, Na$\^$+/, NH$_4$$\^$+/, K$\^$+/, Mg$\^$2+/, Ca$\^$2+/ were 100.7∼315.6kg/km$^2$/month, 30.1∼234.3kg/km$^2$/month, 64.4∼ 139.4kg/km$^2$/month, 7.5∼68.3kg/km$^2$/month, 10.7∼48.7kg/km$^2$/month, 5.6∼27.9kg/km$^2$/month, 4.5∼17.5kg/km$^2$/month, 27.6∼81.7kg/km$^2$/month, respectively.

Characteristics of Food Waste Leachate Treatment in Thermophilic two Stage Anaerobic Digestion Combined UF Membrane (막결합형 고온 이상 혐기성 소화공정에서 음폐수 처리 특성)

  • Kim, Young-O;Jun, Duk-Woo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.20 no.3
    • /
    • pp.21-24
    • /
    • 2012
  • In this study, Anaerobic Membrane Bioreactor(AnMBR) treating food waste leachate was operated to investigate treatment efficiency of anaerobic process, operational parameters and production of biogas. AnMBR was operated under the condition of filtration type of inside-out mode. AnMBR was operated under the condition that range of permeate flux was from 15 to 20 LMH and range of transmembrane pressure was from 1 to $3 kgf/cm^2$. It was not good that AnMBR was performed under direct connection between anaerobic reactor and external UF module. so, this connection method changed to indirect connection using buffer tank was placed between anaerobic reactor and UF external module. TCOD and SCOD values were that influent were about 113 g/L, 62 g/L and effluent were 25 g/L, 12 g/L, respectively. also TCOD and SCOD removal efficiency were 77% and 81%, respectively. but after added UF process, COD and SCOD removal efficiency was increased to 93% and 86%, respectively.