• Title/Summary/Keyword: filtration flux

Search Result 265, Processing Time 0.03 seconds

A feasibility study of a pilot scale two-phase anaerobic digestion with ultra filtration for the treatment of garbage leachate (음식물 탈리액 처리를 위한 파일럿 규모의 막결합형 2상 혐기성 소화 공정 가능성 평가)

  • Lee, Eun-young;Heo, Ahn-hee;Kim, Hyung-kuk;Kim, Hee-jun;Bae, Jae-ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.5
    • /
    • pp.539-545
    • /
    • 2009
  • A feasibility of a pilot scale two-phase anaerobic digestion with ultra filtration system treating garbage leachate were evaluated. The treatment system consisted of a thermophilic acidogenic reactor, a mesophilic methanogenic reactor, and an UF membrane. The average COD removal efficiency of the treatment system was 95% up to the OLR of 3.1 g COD/L/d. The higher COD removal efficiency with membrane unit resulted from the removal of some portion of soluble organics by membrane as well as particulate materials. When the membrane unit was in operation, bulk liquid in acidogenic and methanogenic reactors was partially interchanged, which maintained the acidogenic reactor pH over 5.0 without external chemical addition. Also, with the production of methane in the acidogenic reactor, the organic loading rate of the methanogenic reactor reduced. The initial flux of the membrane unit was $50{\sim}60L/m^2/hr$, but decreased to $5 L/m^2/hr$ after 95 days of operation due to clogging caused by particulate materials such as fibrous materials in garbage leachate. To prevent clogging caused by particulate materials, a pretreatment system such as screening is required. With the improvement with membrane unit operation, the two-phase anaerobic digestion with ultra filtration system is expected to have the possibility of treating garbage leachate.

Effect of Step-aeration on Inorganic Particle Mixtures Filtration in a Submerged Hollow Fiber Microfiltration Membrane (침지식 중공사 정밀여과 분리막에서 무기혼합입자 여과에 대한 단계별 공기세정의 영향)

  • Choi, Youngkeun;Kim, Hyun-Chul;Noh, Soohong
    • Membrane Journal
    • /
    • v.25 no.3
    • /
    • pp.256-267
    • /
    • 2015
  • The goal is to compare two different aeration strategies for a pilot scale operation of submerged microfiltration with respect to the minimization of membrane fouling. A constant aeration (65 L/min) was examined parallel with a step-wise increase in airflow rate (40 to 65 L/min). The airflow rate was stepped to a higher rate every 5 min and the step-aeration cycles were repeated at regular intervals of 15 min. The comparative filtration runs were conducted with synthetic water containing powdered activated carbon (~10 g/L) and/or kaolin (~20 g/L) at a constant flux of 80 LMH. The extent and mechanisms of fouling in the microfiltration were identified by determining hydraulic resistance to filtration and the fouling reversibility after cleaning. Results showed that the step-aeration effectively alleviated fouling in the microfiltration of synthetic water compared to when using constant aeration. A substantial decrease in fouling was achieved by combining with coagulation using aluminum salts regardless of the aeration strategies. The constant aeration resulted in increased pore blocking likely due to increased accumulation of particles on the surface of membrane.

Effects of Fouling Reduction by Intermittent Aeration in Membrane Bioreactors (MBR에서 간헐포기에 의한 오염저감 효과)

  • Choi, Youngkeun;Kim, Hyun-Chul;Noh, Soohong
    • Membrane Journal
    • /
    • v.25 no.3
    • /
    • pp.276-286
    • /
    • 2015
  • The effects of relaxation and backwashing on fouling in ultrafiltration were investigated using full-scale membrane bioreactors (MBRs) which operated at a constant flux of 30 LMH. This paper also estimated the feasibility of using intermittent aeration strategies for minimizing the hydraulic resistance to filtration in comparison with the continuous aeration for running MBRs. Multiple cycles of filtration (14.5 min each) and relaxation (0.5 min each) were repeated. Similarly, a backwash was conducted by replacing a relaxation after each filtration cycle for the comparative performance test. The attached cake thickness on the membrane rapidly increased, caused by subsequent no aeration leading to easier combining with gel layer and the formation of heterogeneous layer on the membrane surface. During periodic backwashing, it is expected that gel and thin cake layer might sufficiently be removed by heterogeneous layer. After periodic backwashing, subsequent cake layer formation during time of no aeration was rapid than frequent no aeration, acting as a prefilter and preventing further irreversible fouling. Based on the Pearson correlation analysis, overall period fouling (dTMP/min) and average of all cycles (dTMP/min) were strongly correlated with the on-off period of aeration for operating MBRs.

A study on possibility of using CST as a fouling evaluation index at MBR (MBR에서 fouling 평가지표로서 CST의 활용 가능성에 대한 연구)

  • Kim, Yun-Ji;Choi, Yun-Jeong;Sim, Tae-Suk;Hwang, Sun-Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.6
    • /
    • pp.379-387
    • /
    • 2021
  • In general, trans-membrane pressure (TMP), flux, filtration resistance are used as indicators to evaluate the degree of fouling in MBR. However, they have limitations in determining the level of EPS generation, which is known as an important factor of fouling. Therefore, a new evaluation method is required to monitor the amount of EPS generation. In this study, the applicability of capillary suction time (CST), which is used to measure the dewaterability of sludge, was evaluated as an indirect fouling evaluation index. Statistical analysis was performed to evaluate the effect of EPS on CST, and to determine whether EPS has high similarity with representative fouling evaluation indicators and CST, and quantitatively compared them. As a result, the correlation coefficient between CST and bEPS was 0.7988, which was higher than the correlation coefficient between filtration resistance and bEPS. Since bEPS is a major factor inducing fouling by affecting the formation of the cake layer, it was evaluated that CST, which has a high correlation with bEPS, is suitable to represent EPS. In addition, it was evaluated that the correlation coefficient between filtration resistance and CST was high as 0.7187, which could be used as a fouling evaluation index.

Flux Decline Behavior in Cross-flow Microfiltration of Inorganic Colloidal Suspensions (무기 콜로이드 현탁액의 십자류 정밀여과에 의한 투과유속의 감소거동)

  • Nam Suk-Tae;Han Myeong-Jin
    • Membrane Journal
    • /
    • v.15 no.4
    • /
    • pp.338-348
    • /
    • 2005
  • The permeate flux decline on microfiltration capillary membrane operation was investigated with inorganic colloidal solutions. The permeate flux of the alumina solution is two times higher in average than that of the bentonite solution. The flux decline with increase in operation time was less in the alumina solution than in the bentonite solution. The rate of initial flux decline until 10 min was higher on the bentonite solution over the alumina solution. The decline in permeate flux was due to both the cake formation and the pore blocking. The latter effect was higher in the operation of the bentonite solution. In comparing the ratio of each fouling component to the total fouling fur the $1.0\;kg_f/cm^2$ TMP condition, complete blocking was $9.35\%$, standard blocking was about $6.82\%$ and cake filtration was $83.83\%$, respectively. With the increase in cross flow velocity, the permeate flux increased by $6.0\%$ for the alumina solution and by 14.0 for the bentonite solution. With the increase in average pore size fromm $0.24\;{\mu}m\;to\;0.34\;{\mu}m$, the permeate flux increases 1.61 times for the alumina solution and 1.76 times far the bentonite solution.

Transmembrane Pressures with Respect to Backwashing and Sinusoidal Flux Continuous Operation Modes for the Submerged Hollow Fiber Membrane in the Activated Sludge Solution (활성슬러지 수용액 내 침지식 중공사막의 역세척 및 사인파형 연속투과 운전방식에 따른 막간차압)

  • Jeong, Doin;Jung, Seung Hee;Lee, Sohl;Chung, Kun Yong
    • Membrane Journal
    • /
    • v.25 no.6
    • /
    • pp.524-529
    • /
    • 2015
  • In this study transmembrane pressure (TMP) was measured with respect to operational time by applying the sinusoidal flux continuous operation (SFCO) for the hollow fiber membrane. The hollow fiber module which has $100cm^2$ of effective area and $0.45{\mu}m$ nominal pore size was submerged in the activated sludge solution of MLSS 5,000 mg/L. The critical permeate flux was measured as $26.6L/m^2{\cdot}hr$ by the method of continuous flux step change. TMPs of the filtration/relaxation (FR), FR with backwashing (FR/BW) and SFCO modes were measured. The SFCO mode was more effective than FR and FR/BW modes below the critical permeate flux such as 15, 20 and $25L/m^2{\cdot}hr$. However, the FR/BW was confirmed as more effectively fouling controlled mode than SFCO mode above the critical permeate flux.

Water Treatment of High Turbid Source by Tubular Ceramic Microfiltration with Periodic Water-back-flushing System

  • Lee, Hyuk-Chan;Park, Jin-Yong
    • Korean Membrane Journal
    • /
    • v.9 no.1
    • /
    • pp.12-17
    • /
    • 2007
  • We performed periodic water-back-flushing using permeate water to minimize membrane fouling to enhance permeate flux in tubular ceramic microfiltration system for water treatment of high turbid source. The filtration time (FT) = 2 min with periodic 6 sec water-back-flushing showed the highest value of dimensionless permeate flux ($J/J_o$), and the lowest value of resistance of membrane fouling ($R_f$), and we acquired the highest total permeate volume $(V_T)\;=\;6.805L$. Also in the result of BT effect at fixed FT = 10 min and BT (back-flushing time) = 20 sec showed the lowest value of $R_f$ and the highest value of $J/J_o$, and we could obtain the highest $V_T\;=\;6.660\;L$. Consequently, FT = 2 min and BT = 6 sec could be the optimal condition in water treatment of high turbid source above 10 NTU. However, FT = 10 min and BT = 20 sec was superior to reduce operating costs because of lower back-flushing frequency. Then the average quality of water treated by our tubular ceramic MF system was turbidity of 0.07 NTU, $COD_{Mn}$ of 1.86 mg/L and $NH_3-N$ of 0.007 mg/L.

Effects of the Membrane Materials on the Filtration Characteristic in the Membrane Separation-activated Sludge Process (막 재질에 따른 막분리활성오니법의 여과 특성)

  • Kim, Hyung-Soo;Cho, Sang-Il
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.2
    • /
    • pp.42-49
    • /
    • 1998
  • By checking the variations of the raw water quality and MLSS, the effects of the membrane materials on permeable flux and quality of the treated water were investigated in this study. Due to the stability for high variations of MLSS, tubular type membranes were selected. Polysulfone group membranes and polyamide group membranes were tested. The crossflow operation mode was adapted, because membrane fouling problems could be easily controlled by adjusting the linear velocity. Due to the high concentration of the raw water, polyamide group membranes were originally expected to achieve two times higher permeable fluxes. However, difference was only approximately $20l/m^2{\cdot}h$ at $3kgf/cm^2$. It might be resulted from the high concentration of organic materials in the effluent of the RBC process. For the quality of the treated water, polyamide group membranes were slightly less effective. It might be resulted from the fact that polysulfone group membranes had more adsorptive capacities for the organic materials. The effects of temperature on the permeable flux were found to be significant. Despite of the irregular injection of raw water, the quality of the treated water was kept stable.

  • PDF

Separation Purification Characteristics of Rinsing Solution in Semiconductor Process using High Performance Polymer Membranes( II ) (기능성 고분자막을 이용한 반도체 공정 세정액의 분리정제특성( II ))

  • Lee Jae-Dal;Hong Young-Ki;Ro Duck-Kil;Bae Kie-Seo
    • Textile Coloration and Finishing
    • /
    • v.17 no.4 s.83
    • /
    • pp.21-26
    • /
    • 2005
  • A combination separation system is composed of three parts, simple microfiltration unit for the pretreatment of real waste IPA, pervaporation unit with plate and frame type module(the effective membrane area 9,040$cm^2$), and simple ultrafiltration unit as a refiner. Utrafiltration module with hollow fiber membrane(MWCO 10,000) used to purify waste aqueous IPA solution. In addition, the flux of $CMPA-K^+$ composite membrane for waste aqueous IPA solution was very steady-state with long experiment time(30 days). And the standard deviation($\sigma$) was 0.152 and then the coefficient of variation($CV\%$)was 10.82 The IPA concentration on the membrane performance using pervaporation module system could be increased from $89.85wt(\%)$ to more than $99.90wt\%$ in about 8hr at operation temperature of $70^{\circ}C$ using the pervaporation module system. Therefore, a combination separation process system of simple filtration and pervaporation was very effective for the purpose of the IPA purification and reuse front industrial electronic components cleaning process.

Development of blend membrane by sulfonated polyethersulfone for whey ultrafiltration

  • Esfandian, Fatemeh;Peyravi, Majid;Qoreyshi, Ali Asqar;Jahanshahi, Mohsen
    • Membrane and Water Treatment
    • /
    • v.7 no.2
    • /
    • pp.155-173
    • /
    • 2016
  • The present work has been focused on the development of polysulfone (PSf) ultrafiltration membrane via blending by sulfonated polyethersulfone (SPES) in order to permeability enhancement for ultrafiltration of cheese whey. In this regards, sulfonation of polyethersulfone was carried out and the degree of sulfonation was estimated. The effect of blend ratio on morphology, porosity, permeation and fouling of PSf / SPES membranes was investigated. Filtration experiments of whey were conducted for separation of macromolecules and proteins from the lactose enrichment phase. The morphology and performance of membranes were evaluated using different techniques such SEM, AFM, and contact angle measurements. The contact angle measurement showed that the hydrophilicity of membrane was increased by adding SPES. According to AFM images, PSf / SPES membranes exhibited lower roughness compared to neat PSf membrane. The water and whey flux of these membranes were higher than neat membrane. However, flux was decreased when the PSf / SPES blend ratio was 0/100. It can be attributed to pore size and morphology changes. Further, fouling parameters of PSf membrane were improved after blending. The blend membranes show a great potential to be used practically in proteins separation from cheese whey.