• 제목/요약/키워드: filtration

검색결과 3,330건 처리시간 0.045초

선박 디젤엔진 배출 미세먼지 저감을 위한 정전 여과 매연 집진기 개발에 관한 연구 (An Electrostatic Diesel Particulate Filtration System for Removal of Fine Particulate Matters from Marine Diesel Engines)

  • 김영훈;이건희;홍기정;김용진;김학준;박인용;한방우
    • 한국입자에어로졸학회지
    • /
    • 제19권4호
    • /
    • pp.101-110
    • /
    • 2023
  • In order to reduce particulate matters (PM) from marine diesel engines, we developed novel electrostatic diesel particulate matter filtration system. Electrostatic diesel particulate filtration (DPF) system consists of electrostatic charger and filtration part. The electrostatic charger and filtration part are composed of a metal discharge electrode and a metal fiber filter (porosity: 68.1-86.1%), respectively. In the electrostatic charger part, diesel soot particles are reduced by electrostatic force. The filtration part after electrostatic charger part reduces diesel soot particles through inertial and diffusion forces. The filtration efficiency of electrostatic DPF system was examined through the experiments using engine dynamometer system (300 kW) and ship (200 kW). The PM reduction efficiencies due to inertial and electrostatic forces showed about 70-75% and 80-90%, respectively, according to the RPM of the engine. The differential pressure of the electrostatic DPF system applied to the ship was about 1-9 mbar, which was less than the allowable differential pressure for ship engines in South Korea (100 mbar). The results show that the electrostatic DPF system is suitable for application to the PM reduction emitted from ships.

Lie Algebras with all $\underline{1}$-filtrations

  • Jung, K.S.
    • 충청수학회지
    • /
    • 제7권1호
    • /
    • pp.75-86
    • /
    • 1994
  • Let L be a Lie algebra over an algebraically closed field F of chracteristic p > 0 which has an $\underline{1}$-filtration. We prove that W(1;$\underline{1}$) is the only restricted simple Lie algebra having an $\underline{1}$-filtration. And we show that the even dimensional Lie algebra can not have an $\underline{1}$-filtration.

  • PDF

Theoretical Study on Magnetic Field Application for Fine Particle Capture

  • Huang, Shan;Park, Haewoo;Jo, Youngmin
    • 한국입자에어로졸학회지
    • /
    • 제10권2호
    • /
    • pp.45-51
    • /
    • 2014
  • Fine particle capture is facing a challenge since traditional filtration which relies on the combination of impaction, interception, diffusion has a limited efficiency for fine particle capture particularly in size from 0.1 to $0.5{\mu}m$. This paper reviewed the collection efficiency of above mechanisms, as well as magnetic mechanisms for ferromagnetic particles, and mainly studied the influencing factors of magnetic filtration. Filtration velocity, magnetic field intensity and fiber size were found to be the most important parameters for magnetic filtration.

저밀도 세라믹 필터의 고온 여과 성능시험에 관한 연구 (A Study on the High Temperature Filtration Performance Test of Low Density Ceramic Filters)

  • 이동섭;홍민선;최종인
    • 한국대기환경학회지
    • /
    • 제17권1호
    • /
    • pp.75-84
    • /
    • 2001
  • Hot gas filtration method via using ceramic filters is an evolving technology applicable to numerous industrial and air pollution control processes. Alumino silicate, organic and inorganic binders were the major raw materials in manufacturing ceramic filters. In this work, disc type ceramic filters(50$\phi$$\times$10t) were manufactured by vacuum forming processes using ceramic raw materials. The porosity and bulk density of disc type ceramic filers ranged from 86 to 89% and from 0.27 to 0.36 g/㎤, respectively. In this work disc type ceramic medium were tested utilizing coupon experimental apparatus. Disc type filters showed high collection efficiencies over 99.96% with Darchs law coefficients of 4.1$\times$10(sup)10~9.63$\times$10(sup)10/$m^2$ depending on mean pore sizes. In addition, filtration and detachment of ceramic filters turned out to be performed effectively using 10 cm/sec face velocity, 5 minutes filtration cycle, 100msec pulse jet valve opening time and 3 bar pulsing pressure.

  • PDF

케이크 여과에 영향을 미치는 요인에 관한 연구 (A Study on the Factors Affecting Cake Filtration)

  • 장재선
    • 한국환경보건학회지
    • /
    • 제21권2호
    • /
    • pp.7-11
    • /
    • 1995
  • This study was carried out to investigate the change of average specific resistance according to filtration pressure, suspension concentration and filters for study phenomena occurring in cake filtration. As the results of this study, the following conclusions were obtained. It was estimated that the average specific resistance of filtration Was decreased in proportion to decreased of filtration pressure. But in very pressure, average specific resistance was increased. The average specific resistance value on filter medium by various pressure was showed as same trends under constant suspension concentration. This phenomenon was though that a carrain amount of fine particles in the cake was found to migrate throught the cake in the case of very thin at very low pressure. In relation to the change of suspension concentration, average specific resistance value become low according to decreased in supension concentration.

  • PDF

방사선차폐물질(放射線遮蔽物質)에서 발생(發生)하는 측방산란선(側方散亂線)의 측정(測定) (The Relationship of the Filtration and the Side-scattered Dose in Verious Radiation Shielding Materials)

  • 허준;김창균
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제7권1호
    • /
    • pp.35-40
    • /
    • 1984
  • Side-direction scattered dose from various radiation shielding materials was measured at 50cm distance from the central beam of primary ray by used several kinds of added filters for a x-ray deep therapeutic installation, the obtained results were as follows : 1. Dose rate by tube voltage was more increased at heavy filtration than light filtration. 2. Scattered doses produced by constant tube voltage in all shielding materials were decreased at heavier filtration. 3. Scattered doses produced by constant shielding material in all tube voltages were decreased at heavier filtration.

  • PDF

윤활시스템용 오일필터로서 충전밀도 변화에 따른 자성폴리머 필터의 여과특성 연구 (A Study on The Filtration Characteristics of Magnetic Fibrous Polymeric Filter with Packing Density Profile as a New Oil Filter)

  • 최기영;안병길;최웅수;권숙인;권오관
    • Tribology and Lubricants
    • /
    • 제11권2호
    • /
    • pp.8-14
    • /
    • 1995
  • The filtration of the magnetic fibrous polymeric filter with packing density profile made of a self-bonded, nonwoven structure comprising a thermoplastic polymer and a magnetic substance was investigated using an oil filter tester, a particle quantifier and an image analyzer system. The magnetic fibrous polymeric filter showed excellent filtration efficiency compared with conventional paper filter. From the experimental results, It is deduced that the filtration mechanism of conventional paper filter is only the function of physical porosity by surface filteration. On the other hand, the newly magnetic fibrous polymeric filter is designed with a new concept in filtration mechanism. That is, it has a dual function of depth and magnetic filters by physical porosity and magnetic attraction. The newly magnetic fibrous polymeric filter has been shown to be a highly effective oil filter for lubrication systems.

강변여과에서 콜로이드 물질이 오염물 거동에 미치는 영향 (Effect of Colloids on Contaminant Transport in Riverbank Filtration)

  • 김대환;이상일;유상연
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2005년도 학술발표회 논문집
    • /
    • pp.1398-1402
    • /
    • 2005
  • Riverbank filtration is a natural process using alluvial aquifers to remove contaminants and pathogens in river water for the production of drinking water. In riverbank filtration, the understanding of contaminant transport is an important task for the production of high quality drinking water. This study investigates the transport behavior of hydrophobic organic contaminants when colloids (dissolved organic matter and bacteria) are present in the aquifer. A mathematical model for the transport of contaminants is developed and solved numerically for various situations. Results show that in the riverbank filtration the presence of DOM and bacteria enhances the mobility of contaminant significantly. Sensitivity analysis indicates that the distribution of the total aqueous Phase contaminant is significantly affected by distribution coefficients which account for affinity of solid or colloidal Phase to contaminant.

  • PDF

The Effect of Vacuum Pressure in Membrane Filtration Systems for the Efficient Detection of Bacteria from Natural Mineral Water

  • LEE, KI-YONG;CHANG-JAE WOO;TAE-RYEON HEO
    • Journal of Microbiology and Biotechnology
    • /
    • 제8권2호
    • /
    • pp.124-128
    • /
    • 1998
  • The procedures currently used for determining microbiological quality of natural mineral water recommend filtration through membrane filters. In this study, we evaluated the effect of vacuum pressure for the accurate detection of bacteria from water samples seeded with Escherichia coli. We observed that the number of E. coli detected increased with increasing vacuum pressure. In order to examine the retention rate of bacteria in the holes of the membranes under the different pressures, the membrane filters were removed after filtration, washed with sterile water by vortexing, and placed on m-Endo agar plates. With all the filters tested, the number of E. coli retained within the filters at negative 600 mmHg was approximately 10 to $20\%$ higher than that obtained with 100 mmHg. These results demonstrate that the vacuum pressure exerted during the filtration procedure may affect the fixation of bacteria into some portions of openings in the membrane filter.

  • PDF

완속여과 여층 내 종속영양세균의 분포 특성 (Distribution characteristics of heterotropic bacteria population in slow sand filters)

  • 박종근;김성수
    • 상하수도학회지
    • /
    • 제23권1호
    • /
    • pp.23-30
    • /
    • 2009
  • Slow sand filtration (SSF) was the first engineered/mechanical filtration process used in drinking water treatment. In SSF, untreated water slowly percolate through a bed of porous sand. Biological activity within the sand bed have the strongest influence on removal efficiency of pollutants by slow sand filtration. In this study, the microbial population distributions in slow sand filters operated at the various operation conditions was evaluated. The concentrations of $10^4$ to $10^5$ CFU per g dry wt. were observed. No significant differences were seen between the number of filter-covered materials. The data indicate that the temperature has affect on population distribution. Also, the light exposure was influenced on microorganism in slow sand filtration according to the heterotropic plate counts. The role of microorganism within the sand media requires further study.