• Title/Summary/Keyword: filter performance

Search Result 4,615, Processing Time 0.035 seconds

Design and Performance Evaluation of a Complementary Filter for Inverted Pendulum Control with Inertial Sensors (관성센서를 이용한 도립진자의 제어를 위한 상보필터 설계 및 성능평가)

  • Nakashima, Toshitaka;Chang, Mun-Che;Hong, Suk-Kyo
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.544-546
    • /
    • 2004
  • This paper designs and evaluates a complementary filter for fusion of inertial sensor signals. Specifically, the designed filter is applied to inverted pendulum control where the pendulum's angle information is obtained from low-cost tilt and gyroscope sensors instead of an optical encoder. The complementary filter under consideration is a conventional one which consists of low- and high-pass filters. However, to improve the performance of the filter on the gyroscope, we use an integrator in the filter's outer loop. Frequency responses are obtained with both tilt and gyroscope sensors. Based on the frequency response results, we determine appropriate parameter values for the filter. The performance of the designed complementary filter is evaluated by applying the filter to inverted pendulum control. Experiments show that the performance of the designed filter is comparable to that of an optical encoder and low-cost inertial sensors can be used for inverted pendulum control with the heir of sensor fusion.

  • PDF

Design of a Cascade Adaptive Filter for the Performance sn Detection of Segment (ST세그먼트 검출성능향상을 종속 적응필터의 세계)

  • 박광리;이경중
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.4
    • /
    • pp.517-524
    • /
    • 1995
  • This paper is a study on the design of the cascade adaptive filter (CAF) for baseline wandering elimination in order to enhance the performance of the detection of ST segments in ECG. The CAF using Least Mean Square (LMS) algorithm consists of two filters. The primary adaptive filter which has the cutoff frequency of 0.3Hz eliminates the baseline wandering in raw ECG The secondary adaptive filter removes the remnant baseline wandering which is not eliminated by the primary adaptive filter. The performance of the CAF was compared with the standard filter, the recursive filter, and the adaptive impulse correlated filter (AICF). As a result, the CAF showed a lower signal distortion than the standard filter and the AICF. Also, the CAF showed a better perf'ormance in noise elimination than the standard filter and the recursive filter. In conclusion, considering the characteristics of the noise elimination and the signal distortion, the CAF shows a better performance in the removal of the baseline wandering than the other three Otters and suggests the high performance in the detection of ST segment.

  • PDF

Analysis on the Effectiveness of the Filter Buffer for Low Power NAND Flash Memory (저전력 NAND 플래시 메모리를 위한 필터 버퍼의 효율성 분석)

  • Jung, Bo-Sung;Lee, Jung-Hoon
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.7 no.4
    • /
    • pp.201-207
    • /
    • 2012
  • Currently, NAND Flash memory has been widely used in consumer storage devices due to its non-volatility, stability, economical feasibility, low power usage, durability, and high density. However, a high capacity of NAND flash memory causes the high power consumption and the low performance. In the convention memory research, a hierarchical filter mechanism can archive an effective performance improvement in terms of the power consumption. In order to attain the best filter structure for NAND flash memory, we selected a direct-mapped filter, a victim filter, a fully associative filter and a 4-way set associative filter for comparison in the performance analysis. According to the results of the simulation, the fully associative filter buffer with a 128byte fetching size can obtain the bet performance compared to another filter structures, and it can reduce the energy*delay product(EDP) by about 93% compared to the conventional NAND Flash memory.

Rao-Blackwellized Multiple Model Particle Filter Data Fusion algorithm (Rao-Blackwellized Multiple Model Particle Filter자료융합 알고리즘)

  • Kim, Do-Hyeung
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.4
    • /
    • pp.556-561
    • /
    • 2011
  • It is generally known that particle filters can produce consistent target tracking performance in comparison to the Kalman filter for non-linear and non-Gaussian systems. In this paper, I propose a Rao-Blackwellized multiple model particle filter(RBMMPF) to enhance computational efficiency of the particle filters as well as to reduce sensitivity of modeling. Despite that the Rao-Blackwellized particle filter needs less particles than general particle filter, it has a similar tracking performance with a less computational load. Comparison results for performance is listed for the using single sensor information RBMMPF and using multisensor data fusion RBMMPF.

Performance Test of Air Filter Media (필터여재의 성능평가)

  • Ahn, K.H.;Bae, G.N.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.4
    • /
    • pp.417-426
    • /
    • 1994
  • Filter media performance was evaluated using monodisperse NaCl particles with Differential Mobility Analyzer and Ultrafine Condensation Particle Counter. Low or medium performance filters show that the most penetrating particles size(MPPS) is around $0.3{\mu}m$ in diameter and is shifted to smaller sizes as the filter face velocity increases. However, HEPA and ULPA filters show MPPS is around $0.15{\mu}m$ in diameter and is also shifted to $0.1{\mu}m$ in diameter as the face velocity increases. In case of electret filter, the MPPS is found around $0.04{\mu}m$ region for Boltzmann charge equilibrium particles. There is a tendency of strong collection efficiency decrease for large particles as the face velocity increases on the contrary to the other filters. One of the medium performance filter efficiency was compared with filtration theory and the good agreetment was found in the experimental range.

  • PDF

Performance Evaluation of the Modified IMMPDA Filter Using 3-D Maneuvering Targets In Clutter (클러터 환경하에서 3 차원 기동표적을 사용한 수정된 IMMPDA 필터의 성능 분석)

  • 김기철;홍금식;최성린
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.211-211
    • /
    • 2000
  • The multiple targets tracking problem has been one of main issues in the radar applications area in the last decade. Besides the standard Kalman filtering, various methods including the variable dimension filter, input estimation filter, interacting multiple model (IMM) filter, federated variable dimension filter with input estimation, probable data association (PDA) filter etc. have been proposed to address the tracking and sensor fusion issues. In this paper, two existing tracking algorithms, i.e. the IMMPDA filter and the variable dimension filter with input estimation (VDIE), are combined for the purpose of improving the tracking performance of maneuvering targets in clutter. To evaluate the tracking performance of the proposed algorithm, three typical maneuvering patterns i.e. Waver, Pop-Up, and High-Diver motions, are defined and are applied to the modified IMMPDA filter considered as well as the standard IMM filter. The smaller RMS tracking errors, in position and velocity, of the modified IMMPDA filter than the standard IMM filter are demonstrated through computer simulations.

  • PDF

Treatment Study of the Turbid Water by High-Speed Synthetic Fiber Filter System (합성섬유 여재를 충진한 고속여과장치에 의한 탁수처리에 관한 연구)

  • Park, Kisoo;Cheng, Jing;Kim, Youngchul
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.3
    • /
    • pp.262-271
    • /
    • 2015
  • Laboratory study was undertaken to pursue the filter performance of a micro-filter module employing highly porous fiber media under a high filtration rate (over 1,500 m/day), faster than that of any conventional filter process. The effects of filtration rate, head loss, raw water turbidity, and filter aid chemicals on filter performance were analyzed. In spite of the extremely high filtration rate, the filter achieved an attractive efficiency, reducing the raw water turbidity by over 80%. As with other filter systems, the filter aid used (PAC in this study) greatly affected the performance of this particular fiber filter. Long term repetitive runs were additionally carried out to confirm the reproducibility of the filter performance. Finally, a comparison was carried out with other high rate filter systems which are either being tested for use in experimental studies, or are already commercially available.

Performance and Robustness of Discrete Perturbation Observer

  • Sangjoo Kwon;Chung, Wan-Kyun;Youngil Youm
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.31.5-31
    • /
    • 2001
  • In conventional perturbation estimators such as disturbance observers(DOB) [1, 2] or time-delayed controllers(TDC) [3{5}, the low pass filter(so-called Q-filter) plays an important role in the stability and performance. However, a general design guideline or analysis for the Q-filter has not been researched yet. In this paper, a guideline for the design of discrete Q-filter is suggested in terms of the analysis of the relationship between the filter parameters and stability performance robustness in discrete-time domain. The analysis clarifies the discrete-time effect of the perturbation estimator and provides a transparent relationship between performance and robustness depending ...

  • PDF

Evaluation of the Relationship between Filter Replacement and Filter Performance Change in Particulate Respirators (방진 마스크 필터 교체와 성능 변화의 상관성 조사)

  • Lee, Heonyung;Park, Jihoon;Yoon, Chungsik
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.4
    • /
    • pp.283-290
    • /
    • 2017
  • Objectives: This study aimed to evaluate the relationship between filter replacement and filter performance change in particulate filters used in the workplace. Methods: Three types of particulate respirator filters are mainly used in the workplaces. These were tested against the filter performance safety certification standard for dust masks established by the Ministry of Employment and Labor(MoEL). Used filters were collected to test their performance, such as filter pressure drop, efficiency, and quality factors. All these factors were evaluated by a filter tester. To compare filter performance between used and new ones, the same kinds of new filters were also tested together under the same procedures. Results: A total of 270 used filters were collected for testing. The main reasons to replace the filters were difficulty in breathing(46.2%), dirty/odor influx(19.7%), and a combination of factors(26.7%). The pressure drop for two special class groups was significantly different(new filters: $20.72{\pm}3.33mmH_2O$; used filters: $24.70{\pm}5.26mmH_2O$, p<0.0001). In the case of penetration, new filter groups indicated $0.0032{\pm}0.0040%$, while that of the used filters was $0.0596{\pm}0.1187%$. The quality factor for the used filters($0.34{\pm}0.09$) significantly decreased compared to the new filters($0.53{\pm}0.08$) (p<0.0001). Conclusions: Filter performance including pressure drop, penetration, and the quality factor was evaluated and compared between new and used filters in the workplace. The results showed that general filter performance deteriorated more for change of pressure drop, penetration and the quality factor.

Experimental Evaluation of Filter Performance of Depth Filter Media Cartridge with Varying the Pleat Count and the Cartridge Assembly Arrangement

  • Hasolli, Naim;Park, Young-Ok;Rhee, Young-Woo
    • Particle and aerosol research
    • /
    • v.8 no.4
    • /
    • pp.133-141
    • /
    • 2012
  • A new depth filter media was designed and samples of flat sheet as well as cartridge assembly were prepared and tested to evaluate the filtration performance and compare with the commercial product. The arrangement of the depth filter media layers is important to reach the optimal filtration parameters like filter pressure drop, particle collection efficiency and dust holding capacity. Initially, both flat sheet samples of new media and commercial product have been tested using standard test units. Tests with new depth filter media cartridges of various pleat count were conducted in order to find the optimal pleat count which would represent the lowest pressure drop. These tests give an insight on how the pleat count and the assembly configuration affect the performance of the depth filter media cartridge. By comparing the samples with a commercial product we could confirm relatively high filtration performance of the sample cartridge with pleat count 150 made of new depth filter media. The cartridge with the same pleat count exhibits better performance without the outer mesh.