• Title/Summary/Keyword: film-less system

Search Result 180, Processing Time 0.027 seconds

Effects of Cover Crops and Sowing Methods on Weed Occurrences, Growth and Yield in Foxtail Millet Fields (파종방법과 피복작물이 조의 생육과 잡초발생에 미치는 영향)

  • Jeon, Seung-Ho;Shim, Doo-Bo;Kim, Seok-Hyeon;Chung, Jong-Il;Kim, Min-Chul;Chung, Jeong-Sung;Yoon, Seong-Tak;Shim, Sang In
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.57 no.4
    • /
    • pp.337-342
    • /
    • 2012
  • This study was conducted to evaluate the weed suppressing effects of different cropping system including hairy vetch and rye cover crops, polyethylene plastic film, and transplanting film mulching in direct sowing and transplanted foxtail millet field in 2011. Crop growth and development and weed occurrences in the fields were examined to know the efficiency of proposed cropping system. In polyethylene film mulching treatment, heading date of foxtail millet was earlier by 4 days than control, on the other hands, rye cover crop mulching delayed heading date by 8 days. Besides the effect of cover crop on the heading of foxtail millet, the residues changed growth characteristics. Plant height of foxtail millet was increased by 92.4% at hairy vetch treatment although the height of was reduced by 63.7% in the rye cover crop treatment. Hairy vetch treatment showed beneficial effects on foxtail millet growth reduced the occurrences of grasses and broadleaf weeds higher than 90%, as compared to control in foxtail millet fields. While rye cover crop treatment showed poor foxtail millet growth reduced less strongly grasses and broad-leaf weeds by 47% and 90%, respectively. At harvest, yield of foxtail millet was greater in order of hairy vetch cover crop > polyethylene film mulching > rye cover crop ${\fallingdotseq}$ control in both transplanted and direct sown fields.

Improving the Distribution of Temperature by a Double Air Duct in the Air-Heated Plastic Greenhouse (시설내 온도분포 균일화를 위한 온풍난방기용 2중 덕트개발)

  • 김태영;김기덕;조일환;남은영;남윤일;우영회;문보흠
    • Journal of Bio-Environment Control
    • /
    • v.13 no.3
    • /
    • pp.162-166
    • /
    • 2004
  • Air temperature variation along the length of the air duct in an air-heated plastic greenhouse was large, 13 ~ 15$^{\circ}C$ between the front and the rear side of a greenhouse. To reduce this temperature variation, a new PE-film air duct having a small duct inside a large duct (double duct) was developed. This double duct was consisted of an inner duct with air outlets at a 0.15 m interval and an outer duct with air outlets at a 2.5 m interval. Diameters of the air outlet holes were 7, 15, and 35 cm from the front to the end of the inner duct film, while identical 10 cm holes were used on the outer duct film. As a result, air temperature was $46^{\circ}C$ at the beginning side and $47^{\circ}C$ at the ending side, while the conventional single duct had $53^{\circ}C$ at the beginning point and $38^{\circ}C$ at the ending point with a variation of $15^{\circ}C$. Height of a cucumber crop grown in a greenhouse with the new double air duct system was 65.5 cm, 14% increase as compared to that in a greenhouse with a conventional air duct system. Total fruit yield per l0a greenhouse in a greenhouse with the new double air duct system was 4,616 kg, which was 17% greater than that in a greenhouse with a conventional air duct system. Amount of heating oil consumption during March 3 to April 24, 2002 was 3,233 L per l0a greenhouse with the new double air duct system, which was 13% less than that with a conventional air duct system.

Dosimetric Verification of Dynamic Conformal Arc Radiotherapy (입체조형 동적회전조사 방사선치료의 선량 검증)

  • Kim Tae Hyun;Shin Dong Ho;Lee Doo Hyun;Park Sung Yong;Yun Myung Guen;Shin Kyung Hwan;Py Hong Ryull;Kim Joo-Young;Kim Dae Yong;Cho Kwan Ho;Yang Dae-Sik;Kim Chul-Yong
    • Progress in Medical Physics
    • /
    • v.16 no.4
    • /
    • pp.166-175
    • /
    • 2005
  • The purpose of this study is to develop the optimization method for adjusting the film isocenter shift and to suggest the quantitative acceptable criteria for film dosimetry after optimization In the dynamic conformal arc radiation therapy (DCAR). The DCAR planning was peformed In 7 patients with brain metastasis. Both absolute dosimetry with ion chamber and relative film dosimetry were peformed throughout the DCAR using BrainLab's micro-multileaf collimator. An optimization method for obtaining the global minimum was used to adjust for the error in the film isocenter shift, which is the largest pan of systemic errors. The mean of point dose difference between measured value using ion chamber and calculated value acquired from planning system was $0.51{\pm}0.43\%$ and maximum was $1.14\%$ with absolute dosimetry These results were within the AAPM criteria of below $5\%$. The translation values of film isocenter shift with optimization were within ${\pm}$1 mm in all patients. The mean of average dose difference before and after optimization was $1.70{\pm}0.35\%$ and $1.34{\pm}0.20\%$, respectively, and the mean ratios over $5\%$ dose difference was $4.54{\pm}3.94\%$ and $0.11{\pm}0.12\%$, respectively. After optimization, the dose differences decreased dramatically and a ratio over $5\%$ dose difference and average dose difference was less than $2\%$. This optimization method is effective in adjusting the error of the film isocenter shift, which Is the largest part of systemic errors, and the results of this research suggested the quantitative acceptable criteria could be accurate and useful in clinical application of dosimetric verification using film dosimetry as follows; film isocenter shift with optimization should be within ${\pm}$1 mm, and a ratio over $5\%$ dose difference and average dose difference were less than $2\%$.

  • PDF

A 4-Wavelength Optical Transceiver with Improved Characteristics using WDMs and OADMS (WDM 및 OADM으로 구성된 개선된 특성의 1310nm, 1550nm 대역 4파장 광중계기)

  • 이인재;이동길;최삼길;이유종
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.406-409
    • /
    • 2003
  • In this paper, a 4-wavelength optical transceiver system is designed and implemented by using TFF (thin film filter) type OADMs (optical add-drop multiplexers). In this new system, the wavelengths of 1510 nm and 1530 nm are used for uploa and download signals, respectively, as well as the wavelengths of 1550 nm and 1310 nm which have been utilized in a 2-wavelength optical transceiver systems. The 4-wavelength optical module show pass characteristics of -1.6 dBm, -1.7 dBm, -5.6 dBm, -5.8dBm for 1510nm, 1530 nm, 1550 nm, 1570 nm, respectively, with 1.2 dBm of input laser power. The isolation for characteristics of the optical module for all the wavelengths are less than -40dB, which is very acceptable for filed requirements.

  • PDF

Chemiresistive Sensor Based on One-Dimensional WO3 Nanostructures as Non-Invasive Disease Monitors

  • Moon, Hi Gyu;Han, Soo Deok;Kim, Chulki;Park, Hyung-Ho;Yoon, Seok-Jin
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.291-294
    • /
    • 2014
  • In this study, a chemiresistive sensor based on one-dimensional $WO_3$ nanostructures is presented for application in non-invasive medical diagnostics. $WO_3$ nanostructures were used as an active gas sensing layer and were deposited onto a $SiO_2/Si$substrate using Pt interdigitated electrodes (IDEs). The IDE spacing was $5{\mu}m$ and deposition was performed using RF sputter with glancing angle deposition mode. Pt IDEs fabricated by photolithography and dry etching. In comparison with thin film sensor, sensing performance of nanostructure sensor showed an enhanced response of more than 20 times when exposed to 50 ppm acetone at $400^{\circ}C$. Such a remarkable faster response can pave the way for a new generation of exhaled breath analyzers based on chemiresistive sensors which are less expensive, more reliable, and less complicated to be manufactured. Moreover, presented sensor technology has the potential of being used as a personalized medical diagnostics tool in the near future.

Adsorption Characteristics of Sr(II) and Cs(I) ions by Zeolite Synthesized from Coal Fly Ash (Coal Fly Ash로 합성한 제올라이트에 의한 Sr(II)과 Cs(I) 이온의 제거 특성)

  • Lee, Chang-Han;Park, Jeong-Min;Lee, Min-Gyu
    • Journal of Environmental Science International
    • /
    • v.23 no.12
    • /
    • pp.1987-1998
    • /
    • 2014
  • Zeolite was synthesized from power station waste, coal fly ash, as an alternative low-cost adsorbent and investigated for the removal of Sr(II) and Cs(I) ions from single- and binary metal aqueous solutions. In order to investigate the adsorption characteristics, the effects of various operating parameters such as initial concentration of metal ions, contact time, and pH of the solutions were studied in a batch adsorption technique. The Langmuir model better fitted the adsorption isotherm data than the Freundlich model. The pseudo second-order model was found more applicable to describe the kinetics of system. The adsorption capacities of Sr(II) and Cs(I) ions obtained from the Langmuir model were 1.7848 mmol/g and 0.7640 mmol/g, respectively. Although the adsorption capacities of individual Sr(II) and Cs(I) ions was less in the binary-system, the sum of the total adsorption capacity (2.3572 mmol/g) of both ions in the binary-system was higher than the adsorption capacity of individual ion in the single-system. Comparing the homogeneous film diffusion model with the homogeneous particle diffusion model, the adsorption was mainly controlled by the particle diffusion process.

An analytical solution for the close-contact melting with vertical convection and solid-liquid density difference (종방향대류 및 고액밀도차가 고려된 접촉융해에 대한 해석해)

  • Yu, Ho-Seon;Hong, Hui-Gi;Kim, Chan-Jung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.9
    • /
    • pp.1165-1173
    • /
    • 1997
  • The steady state close-contact melting phenomenon occurring between a phase change material and an isothermally heated flat plate with relative motion is investigated analytically, in which the effects of vertical convection in the liquid film and solid-liquid density difference are incorporated simultaneously. Not only the scale analysis is conducted to estimate a priori qualitative dependence of system variables on characteristic parameters, but also an analytical solution to a set of simplified model equations is obtained to specify the effects under consideration. These two results are consistent with each other, in that the vertical convection affects both the solid descending velocity and the film thickness, and that the density difference alters only the solid descending velocity. While the effect of vertical convection can be characterized conveniently by a newly introduced temperature gradient factor which asymptotically approaches the unity/zero with decreasing/increasing the Stefan number, that of density difference is represented by the liquid-to-solid density ratio. It is shown that the solid descending velocity depends linearly on the density ratio, and that the ratios of solid descending velocity, film thickness and friction coefficient to the conduction solution are proportional to 3/4, 1/4 and -1/4 powers of the temperature gradient factor, respectively. Also, established is the fact that the effect of convection can be legitimately neglected in the analysis for the range of the Stefan number less than 0.1.

Improved photoresponsivity of AlGaN UV photodiode using antireflective nanostructure (반사방지 나노 구조체를 이용한 AlGaN UV 광다이오드의 광반응도 향상)

  • Dac, Duc Chu;Choi, June-Heang;Kim, Jeong-Jin;Cha, Ho-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.10
    • /
    • pp.1306-1311
    • /
    • 2020
  • In this study, we proposed an anti-reflective nano-structure to improve the photoresponsivity of AlGaN UV photodiode that can be used as a receiver in a solar blind UV optical communication system. The anti-reflective nano-structure was fabricated by forming Ni nano-clusters on SiO2 film followed by etching the underneath SiO2 film. A sample with the anti-reflective nano-structure exhibited lower surface reflection along with less dependency on the wavelength in comparison with a sample without the nano-structure. Finally, a UV photodiode was fabricated by applying an anti-reflective structure produced by heat-treating a 2 nm-thick Ni layer. The photodiode fabricated with the proposed nano-structure exhibited noticeable improvement in the photoresponsivity at the wavelength range from 240 nm to 270 nm in comparison with the same photodiode with a SiO2 film without the nano-structure.

Analysis of Flow and Heat Transfer in Swirl Chamber for Cooling in Hot Section (고온부 냉각을 위한 스월챔버내의 유동 및 열전달 해석)

  • Lee K. Y.;Kim H. M.;Han Y. M.;Lee S. Y.
    • Journal of computational fluids engineering
    • /
    • v.7 no.3
    • /
    • pp.9-16
    • /
    • 2002
  • Most of modem aerospace gas turbines must be operated at a gas temperature which is several hundreds of degrees higher than the melting temperatures of the materials used in their construction. Complicated cooling schemes need to be employed in the combustor walls and in the high pressure turbine stages. Internal passages are cast or machined into the hot sections of aero-gas turbine engines and air from the compressor is used for cooling. In many cases, the cooling system is engineered to utilize jets of high velocity air, which impinge on the internal surfaces of the components. They are categorized as 'Impinging Cooling Method' and 'Vortex Cooling Method'. Specially, research of new cooling system(Vortex Cooling Method) that overcomes inefficiency of film cooling and limitation of space. The focus of new cooling system that improves greatly cooling efficiency using less amount of cooling air on surface heat transfer elevation. Therefore, in this study, a numerical analysis has been peformed for characteristics of flow and heat transfer in the swirl chamber and compared with the flow measurements by LDV. Especially, for understanding high heat transfer efficiency in the vicinity of wall, we considered flow structure, vortex mechanism and heat transfer characteristics with variation of the Reynolds number.

Analysis of Flow and Heat Transfer in Swirl Chamber for Cooling in Hot Section (고온부 냉각을 위한 스월챔버내의 유동 및 열전달 해석)

  • Lee Kang-Yeop;Kim Hyung-Mo;Han Yeoung-Min;Lee Soo-Yong
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2002.05a
    • /
    • pp.71-78
    • /
    • 2002
  • All modem, aerospace gas turbines must operate with hot stage gas temperature several hundreds of degrees hotter than the melting temperatures of the materials used in their construction. Complicated cooling schemes need to be employed in the combustor walls and In the high pressure turbine stages. Internal passages are cast or machined into the hot sections of aero-gas turbine engines and air from the compressor is used for cooling. In many cases, the cooling system is engineered to utilize jets of high velocity air, which impinge on the internal surfaces of the components. They are divided by Impinging cooling method and Vortex cooling method. Specially, Research of new cooling system(Vortex cooling method) that overcome inefficiency of film cooling and limitation of space. The focus of new cooling system that improve greatly cooling efficiency using quantity's cooling air which is less is set in surface heat transfer elevation. Therefore, In this study, the numerical analysis have been performed for characteristic of flow and thermal in the swirl chamber and compared with the flow field measurement by LDV. especially, for understanding of high heat transfer efficiency in vicinity of wall. we considered flow structure and mechanism of vortex and heat transfer characteristic in variation of Reynolds number.

  • PDF