• Title/Summary/Keyword: film image

Search Result 1,219, Processing Time 0.034 seconds

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

A Convergence Study for the Academic Systematization of Cartoon-animation (만화영상학의 학문적 체계화를 위한 융합적 연구)

  • Lim, Jae-Hwan
    • Cartoon and Animation Studies
    • /
    • s.43
    • /
    • pp.285-320
    • /
    • 2016
  • Cartoons and Animation are convergent arts created with a composite application of language arts described in the form of literary texts and sounds, plastic arts visualized in the form of artistic paintings, and film arts produced in the form of moving pictures. An academic university major in cartoons and animation studies established in late 20th century however, did not satisfactorily meet the needs in academic research and development and the free expression of artistic creation was limited. In order to systematize the major in cartoons and animation studies, an convergent approach to establish and clarify following are in demand : the terms and definitions, the historical developments, the research areas and methods, the major education and related jobs and start-ups. New culture and arts industries including cartoons, animation, moving images, and games contents are not yet listed in the industries listing service jointly provided online by the portal site Naver.com and Hyung-Seol publishing company. Above all, cartoons and animation are inseparably related to each other that even if one uses the term separately and independently, the meaning may not be complete. So a new combined term "Animatoon" can be established for the major in cartoons and animation studies and also used for its degree with concentrations of cartoons, animation, moving images, games, and etc. In the Introduction, a new combined term Animatoon is defined and explained the use of this term as the name of the major and degree in cartoons and animation studies. In the body, first, the Historical Developments classified Animatoon in the ancient times, the medieval times, and the modern times and they are analyzed with the help of esthetics and arts using examples of mural frescos, animal painting, religion cartoons, caricatures, cartoons, satire cartoons, comics, animation, 2 or 3 dimensional webtoons, and K-toons. Second, the Research Areas of Animatoon reviewed the theories, genres, artworks, and artists and the Research Methods of Animatoon presented the curriculum that integrated the courses in humanities, science technologies, culture and arts, and etc. Third, the Major Education considered Animatoon education in children, young adults, students of the major and the Related Jobs and Start-Ups explored various jobs relating to personal creation of artwork and collective production of business-oriented artwork. In the Conclusion, the current challenges of Animatoon considered personalization of the artists, specialization of the contents, diversification of the types, and liberalization of the art creation. And the direction of improvement advocated Animatoon to be an academic field of study, to be an art, to be a culture, and to be an industry. The importance of cartoons and animation along with videos and games rose in the 21st century. In order for cartoons and animation to take a leading role, make efforts in studying Animatoon academically and also in developing Animatoon as good contents in the cultural industries.

The new explore of the animated content using OculusVR - Focusing on the VR platform and killer content - (오큘러스 VR (Oculus VR)를 이용한 애니메이션 콘텐츠의 새로운 모색 - VR 플랫폼과 킬러콘텐츠를 중심으로 -)

  • Lee, Jong-Han
    • Cartoon and Animation Studies
    • /
    • s.45
    • /
    • pp.197-214
    • /
    • 2016
  • Augmented Reality, virtual reality in recently attracted attention throughout the world. and Mix them mixed reality etc., it has had a significant impact on the overall pop culture beyond the scope of science and technology. The world's leading IT company : Google, Apple, Samsung, Microsoft, Sony, LG is focusing on development of AR, VR technology for the public. The many large and small companies developed VR hardware, VR software, VR content. It does not look that makes a human a human operation in the cognitive experience of certain places or situations or invisible through Specific platforms or program is Encompass a common technique that a realization of the virtual space. In particular, out of the three-dimensional image reveals the limitations of the conventional two-dimensional structure - 180, 360 degree images provided by the subjective and objective symptoms such as vision and sense of time and got participants to select it. VR technology that can significantly induce the commitment and participation is Industry as well as to the general public which leads to the attention of colostrum. It was introduced more than 10 related VR works Year 2015 Sundance Film Festival New Frontier program. The appearance VR content : medical, architecture, shopping, movies, animations. Also, 360 individuals can be produced by the camera / video sharing VR is becoming an interactive tunnel between two possible users. Nevertheless, This confusion of values, moral degeneration and the realization of a virtual space that has been pointed out that the inherent. 4K or HUD, location tracking, motion sensors, processing power, and superior 3D graphics, touch, smell, 4D technology, 3D audio technology - It developed more than ever and possible approaches to reality. Thereafter, This is because the moral degeneration, identity, generational conflict, and escapism concerns. Animation is also seeking costs in this category Reality. Despite the similarities rather it has that image, and may be the reason that the animation is pushed back to the VR content creation. However, it is focused on the game and VR technology and the platform that is entertaining, but also seek new points within the animation staying in the flat Given that eventually consist of visual images is clear that VR sought. Finally, What is the reality created in the virtual space using VR technology could be applied to the animation? So it can be seen that the common interest is research on what methods and means applied.

The evaluation of custo-made EWHA Breast Device(EBD) (EWHA Breast Device(EBD)의 제작 및 유용성 평가)

  • Byun Young-Sik;Oh Tae-Sung;Park Chong-Yil;Shin Hyun-Kyoh
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.33-40
    • /
    • 2005
  • Purpose : We recently perform the latest radiotheraphy (3D conformal, IMRT,etc.) with the development of 3D CT planning technology. However, in case patients with breast cancer, it is difficult to acquire the CT image with the limitation of CT hole size and tilting of breast immobilization device. The Ewha Breast Device(EBD) was constructed to improve the problem in the treatment of patients with breast cancer and we are intend to introduce the procedure of the EBD construction in this study and compare the EBD with conventional breast device in the view point of usefulness. Materials and Methods : We have constructed the EBD with acryl, analyze the skull size with CT data, consider the skin folder in SCL field and evaluated the EBD usefulness from the view point of set-up reproducibility, dose distribution, skin reaction in comparison with conventional breast device. Results : In the case of patients set-up error analysis, the EBD is superior to conventional device in portal film repetition($\%$) check (80pt.), equal to that in simulation & CT image coincidence check(5pt.). There is no difference between the two systems in dose distribution and skin reaction in SCL field is better the EBD than conventional device. Conclusions : The construction of the EBD enable us to perform the latest radiotheraphy in breast treatments, relieve the pains in simulation, and reduce, the skin reaction. In the future, we expect that modification of the EBD is useful in treating for patients with breast cancer.

  • PDF

Effect of Inhomogeneity correction for lung volume model in TPS (Lnug Volume을 모델로 한 방사선치료계획 시 불균질 조직 보정에 따른 효과)

  • Chung SeYoung;Lee SangRok;Kim YoungBum;Kwon YoungHo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.57-65
    • /
    • 2004
  • Introduction : The phantom that includes high density materials such as steel was custom-made to fix lung and bone in order to evaluation inhomogeneity correction at the time of conducting radiation therapy to treat lung cancer. Using this, values resulting from the inhomogeneous correction algorithm are compared on the 2 and 3 dimensional radiation therapy planning systems. Moreover, change in dose calculation was evaluated according to inhomogeneous by comparing with the actual measurement. Materials and Methods : As for the image acquisition, inhomogeneous correction phantom(Pig's vertebra, steel(8.21g/cm3), cork(0.23 g/cm3)) that was custom-made and the CT(Volume zoom, Siemens, Germany) were used. As for the radiation therapy planning system, Marks Plan(2D) and XiO(CMS, USA, 3D) were used. To compare with the measurement value, linear accelerator(CL/1800, Varian, USA) and ion chamber were used. Image, obtained from the CT was used to obtain point dose and dose distribution from the region of interest (ROI) while on the radiation therapy planning device. After measurement was conducted under the same conditions, value on the treatment planning device and measured value were subjected to comparison and analysis. And difference between the resulting for the evaluation on the use (or non-use) of inhomogeneity correction algorithm, and diverse inhomogeneity correction algorithm that is included in the radiation therapy planning device was compared as well. Results : As result of comparing the results of measurement value on the region of interest within the inhomogeneity correction phantom and the value that resulted from the homogeneous and inhomogeneous correction, gained from the therapy planning device, margin of error of the measurement value and inhomogeneous correction value at the location 1 of the lung showed $0.8\%$ on 2D and $0.5\%$ on 3D. Margin of error of the measurement value and inhomogeneous correction value at the location 1 of the steel showed $12\%$ on 2D and $5\%$ on 3D, however, it is possible to see that the value that is not correction and the margin of error of the measurement value stand at $16\%$ and $14\%$, respectively. Moreover, values of the 3D showed lower margin of error compared to 2D. Conclusion : Revision according to the density of tissue must be executed during radiation therapy planning. To ensure a more accurate planning, use of 3D planning system is recommended more so than the 2D Planning system to ensure a more accurate revision on the therapy plan. Moreover, 3D Planning system needs to select and use the most accurate and appropriate inhomogeneous correction algorithm through actual measurement. In addition, comparison and analysis through TLD or film dosimetry are needed.

  • PDF

A Study on Expressing 3D Animation by Visual Direction : focused on 〈 How to train your dragon 〉 (시각적 연출에 의한 3D 입체 애니메이션 표현 연구: 〈드래곤 길들이기〉를 중심으로)

  • Kim, Jung-Hyun
    • Cartoon and Animation Studies
    • /
    • s.26
    • /
    • pp.1-30
    • /
    • 2012
  • The purpose of animation is to give interesting stories to an audience through motion. To achieve the purpose, over the past century since its inception, animation has adopted many kinds of technologies, and thus developed diverse narrative methods and visual expression techniques. In addition, with the advancement of expression techniques, all elements making up animation have gradually been systemized, and at the same time, have helped express the worlds beyond the reality. As a result, people have faced the era when an audience can watch everything imaginated by an animation director on a big screen. These days, more efforts have been made in order for the audience to feel much more than enjoy pictures moving in a frame. In other words, the purpose of the animation is changing from the passive viewing of animation to feeling and sensing stuffs through the animation. In the center of the changing process is 3D technology which gives new interesting to an audience. Sometime ago, a 3D animation movie was produced in Korea. But it did not bring out box-office profits, for it failed to give satisfaction to an audience who expected high perfection and beauty being able to be rivalled to those of international 3D animation movies. The failure is attributable to the fact that the domestic 3D animation production industry is merely in the early stage, and has not sufficient human resources, technology, and experiences in producing 3D animation films. Moreover, the problem is that most studies on 3D focus on the technologies related to reenactment, but that few studies on the images, which an audience directly faces, have been conducted. Under the domestic circumstance, the study on stereoscopic image screen of , a 3D stereoscopic animation film which was released in 2010 and has been seen as the best successful 3D stereoscopic animation, is worthwhile. Thus this thesis conducted theoretical consideration and case analysis focusing on the visual direction that creates the pictures to deliver abundant three dimensional effect so that it can be used as a basic data when producing high quality-domestic 3D animation and training professional labor forces. In the result, it was found that the 3D animation was not a new area, but the area which has been expanded and changed by applying the characteristics of 3D image based on the principles of the existing media aesthetics. This study might be helpful to establish the foundation of the theoretical studies necessary for producing 3D animation contents for realizing the sense of reality.

Development of Standard Process for Private Information Protection of Medical Imaging Issuance (개인정보 보호를 위한 의료영상 발급 표준 업무절차 개발연구)

  • Park, Bum-Jin;Yoo, Beong-Gyu;Lee, Jong-Seok;Jeong, Jae-Ho;Son, Gi-Gyeong;Kang, Hee-Doo
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.335-341
    • /
    • 2009
  • Purpose : The medical imaging issuance is changed from conventional film method to Digital Compact Disk solution because of development on IT technology. However other medical record department's are undergoing identification check through and through whereas medical imaging department cannot afford to do that. So, we examine present applicant's recognition of private intelligence safeguard, and medical imaging issuance condition by CD & DVD medium toward various medical facility and then perform comparative analysis associated with domestic and foreign law & recommendation, lastly suggest standard for medical imaging issuance and process relate with internal environment. Materials and methods : First, we surveyed issuance process & required documents when situation of medical image issuance in the metropolitan medical facility by wire telephone between 2008.6.1$\sim$2008.7.1. in accordance with the medical law Article 21$\sim$clause 2, suggested standard through applicant's required documents occasionally - (1) in the event of oneself $\rightarrow$ verifying identification, (2) in the event of family $\rightarrow$ verifying applicant identification & family relations document (health insurance card, attested copy, and so on), (3) third person or representative $\rightarrow$ verifying applicant identification & letter of attorney & certificate of one's seal impression. Second, also checked required documents of applicant in accordance with upper standard when situation of medical image issuance in Kyung-hee university medical center during 3 month 2008.5.1$\sim$2008.7.31. Third, developed a work process by triangular position of issuance procedure for situation when verifying required documents & management of unpreparedness. Result : Look all over the our manufactured output in the hospital - satisfy the all conditions $\rightarrow$ 4 place(12%), possibly request everyone $\rightarrow$ 4 place(12%), and apply in the clinic section $\rightarrow$ 9 place(27%) that does not medical imaging issuance office, so we don't know about required documents condition. and look into whether meet or not the applicant's required documents on upper 3month survey - satisfy the all conditions $\rightarrow$ 629 case(49%), prepare a one part $\rightarrow$ 416 case(33%), insufficiency of all document $\rightarrow$ 226case(18%). On the authority of upper research result, we are establishing the service model mapping for objective reception when image export situation through triangular position of issuance procedure and reduce of friction with patient and promote the patient convenience. Conclusion : The PACS is classified under medical machinery that mean indicates about higher importance of medical information therefore medical information administrator's who already received professional education & mind, are performer about issuance process only and also have to provide under ID checking process exhaustively.

  • PDF

Comparison of CT based-CTV plan and CT based-ICRU38 plan in Brachytherapy Planning of Uterine Cervix Cancer (자궁경부암 강내조사 시 CT를 이용한 CTV에 근거한 치료계획과 ICRU 38에 근거한 치료계획의 비교)

  • Cho, Jung-Ken;Han, Tae-Jong
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.3
    • /
    • pp.105-110
    • /
    • 2007
  • Purpose : In spite of recent remarkable improvement of diagnostic imaging modalities such as CT, MRI, and PET and radiation therapy planing systems, ICR plan of uterine cervix cancer, based on recommendation of ICRU38(2D film-based) such as Point A, is still used widely. A 3-dimensional ICR plan based on CT image provides dose-volume histogram(DVH) information of the tumor and normal tissue. In this study, we compared tumor-dose, rectal-dose and bladder-dose through an analysis of DVH between CTV plan and ICRU38 plan based on CT image. Method and Material : We analyzed 11 patients with a cervix cancer who received the ICR of Ir-192 HDR. After 40Gy of external beam radiation therapy, ICR plan was established using PLATO(Nucletron) v.14.2 planing system. CT scan was done to all the patients using CT-simulator(Ultra Z, Philips). We contoured CTV, rectum and bladder on the CT image and established CTV plan which delivers the 100% dose to CTV and ICRU plan which delivers the 100% dose to the point A. Result : The volume$(average{\pm}SD)$ of CTV, rectum and bladder in all of 11 patients is $21.8{\pm}6.6cm^3,\;60.9{\pm}25.0cm^3,\;111.6{\pm}40.1cm^3$ respectively. The volume covered by 100% isodose curve is $126.7{\pm}18.9cm^3$ in ICRU plan and $98.2{\pm}74.5cm^3$ in CTV plan(p=0.0001), respectively. In (On) ICRU planning, $22.0cm^3$ of CTV volume was not covered by 100% isodose curve in one patient whose residual tumor size is greater than 4cm, while more than 100% dose was irradiated unnecessarily to the normal organ of $62.2{\pm}4.8cm^3$ other than the tumor in the remaining 10 patients with a residual tumor less than 4cm in size. Bladder dose recommended by ICRU 38 was $90.1{\pm}21.3%$ and $68.7{\pm}26.6%$ in ICRU plan and in CTV plan respectively(p=0.001) while rectal dose recommended by ICRU 38 was $86.4{\pm}18.3%$ and $76.9{\pm}15.6%$ in ICRU plan and in CTV plan, respectively(p=0.08). Bladder and rectum maximum dose was $137.2{\pm}50.1%,\;101.1{\pm}41.8%$ in ICRU plan and $107.6{\pm}47.9%,\;86.9{\pm}30.8%$ in CTV plan, respectively. Therefore, the radiation dose to normal organ was lower in CTV plan than in ICRU plan. But the normal tissue dose was remarkably higher than a recommended dose in CTV plan in one patient whose residual tumor size was greater than 4cm. The volume of rectum receiving more than 80% isodose (V80rec) was $1.8{\pm}2.4cm^3$ in ICRU plan and $0.7{\pm}1.0cm^3$ in CTV plan(p=0.02). The volume of bladder receiving more than 80% isodose(V80bla) was $12.2{\pm}8.9cm^3$ in ICRU plan and $3.5{\pm}4.1cm^3$ in CTV plan(p=0.005). According to these parameters, CTV plan could also save more normal tissue compared to ICRU38 plan. Conclusion : An unnecessary excessive radiation dose is irradiated to normal tissues within 100% isodose area in the traditional ICRU plan in case of a small size of cervix cancer, but if we use CTV plan based on CT image, the normal tissue dose could be reduced remarkably without a compromise of tumor dose. However, in a large tumor case, we need more research on an effective 3D-planing to reduce the normal tissue dose.

Evaluation of Planning Dose Accuracy in Case of Radiation Treatment on Inhomogeneous Organ Structure (불균질부 방사선치료 시 계획 선량의 정확성 평가)

  • Kim, Chan Yong;Lee, Jae Hee;Kwak, Yong Kook;Ha, Min Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.137-143
    • /
    • 2013
  • Purpose: We are to find out the difference of calculated dose of treatment planning system (TPS) and measured dose in case of inhomogeneous organ structure. Materials and Methods: Inhomogeneous phantom is made with solid water phantom and cork plate. CT image of inhomogeneous phantom is acquired. Treatment plan is made with TPS (Pinnacle3 9.2. Royal Philips Electronics, Netherlands) and calculated dose of point of interest is acquired. Treatment plan was delivered in the inhomogeneous phantom by ARTISTE (Siemens AG, Germany) measured dose of each point of interest is obtained with Gafchromic EBT2 film (International Specialty Products, US) in the gap between solid water phantom or cork plate. To simulate lung cancer radiation treatment, artificial tumor target of paraffin is inserted in the cork volume of inhomogeneous phantom. Calculated dose and measured dose are acquired as above. Results: In case of inhomogeneous phantom experiment, dose difference of calculated dose and measured dose is about -8.5% at solid water phantom-cork gap and about -7% lower in measured dose at cork-solid water phantom gap. In case of inhomogeneous phantom inserted paraffin target experiment, dose difference is about 5% lower in measured dose at cork-paraffin gap. There is no significant difference at same material gap in both experiments. Conclusion: Radiation dose at the gap between two organs with different electron density is significantly lower than calculated dose with TPS. Therefore, we must be aware of dose calculation error in TPS and great care is suggested in case of radiation treatment planning on inhomogeneous organ structure.

  • PDF

A Study on the Dépaysement of the Animation (애니메이션에 있어서 데페이즈망에 관한 연구)