• Title/Summary/Keyword: film filter

Search Result 335, Processing Time 0.028 seconds

The Preparation of ZnO Piezo-electric Thin Film for Surface Acoustic Wave Filter (탄성표면파 필터용 ZnO 압전 박막의 제조)

  • Lee, Dong-Yoon;Park, Jae-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.10-14
    • /
    • 2005
  • Zinc Oxide(ZnO) thin films on Si (100) substrates were deposited by RF magnetron reactive sputtering. The characteristics of zinc oxide thin films with changing sputtering conditions such as argon/oxygen gas ratios, RF power, and substrate temperature, chamber pressure and target-substrate distance were investigated. To analyze a crystallographic properties of the films, $\theta/2{\theta}$ mode X -ray diffraction, SEM, and AFM analyses. C-axis preferred orientation, resistivity, and surface roughness highly depended on Ar/$O_2$ gas ratios. The resistivity of ZnO thin films rapidly increased with increasing oxygen ratio and the resistivity value of $9{\times}10^7\;{\Omega}cm$ was obtained at a working pressure of 10 mTorr with Ar/$O_2$=50/50. The surface roughness was also improved with increasing oxygen ratio and the ZnO films deposited with Ar/$O_2$=50/50 showed the excellent roughness value of $28.7{\AA}$.

  • PDF

Fabrication and Optical Characterization of Rugate-structured Polymer Replicas

  • Kim, Ji-Hoon;Park, Cheol-Young;Kim, Sung-Jin;Park, Jae-Hyun;Ko, Young-Chun;Woo, Hee-Gweon;Sohn, Hong-Lae
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.11
    • /
    • pp.2079-2082
    • /
    • 2007
  • Photonic crystals containing rugate structure result in a mirror with high reflectivity in a specific narrow spectral region and are prepared by applying a computer-generated pseudo-sinusoidal current waveform. Well defined 1-dimentional photonic polymer replicas showing a reflectivity at 534 nm have been successfully obtained by the removal of rugate porous silicon (PSi) template from the polystyrene composite film. XRD measurement indicates that the oxidized rugate PSi has been completely removed from the composite films. Polymer replicas exhibit a sharp resonance in the reflectivity spectrum. Optical characteristics of photonic polymer replicas indicate that the surface of polymer film has a negative structure of rugate PSi. These replicas are stable in aqueous solutions for several days without any degradation. The methods have been provided for the construction of photonic structures with polymers.

Dose Reduction of the Adolescent Female Breast during Scoliosis Radiography (청소년기 여성의 척추측만증 검사에서 유방입사선량 저감효과)

  • Jin, Gye Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.373-379
    • /
    • 2018
  • The purpose of this study was to investigate quantitative data on the difference in breast entrance surface dose with changes in focus-film distance, patient posture (anteroposterior-posteroanterior), thoracic wall thickness, rib bone thickness, lung tissue thickness, tube voltage, and high-voltage rectification method in Whole Spine Scanography, which is necessary for the treatment of scoliosis patients. Given a tube voltage of 90 kVp, kerma of 0.1 mGy, focus-film distance of 260 cm, tube voltage ripple rate of 0, filter thickness of 3.5 mm, and thickness of patient's thoracic wall of 120 mm as an X-ray exposure condition, from the simulation results using the Simulation of X-ray Spectra program to confirm the reduction effect of breast entrance surface dose according to the patient's posture (AP and PA), there was a dose reduction effect in aluminum filter thickness of 2.6 times at 3.5 mm, 25.7 times the thoracic wall thickness at 120 mm, 1.43 times higher tube voltage, and 0 to 1.14 times the tube voltage ripple rate. The total dose reduction effect was about 109 times. In order to confirm the dose reduction effect of RANDO phantom posture (AP and PA), from the results of the measurements taken under the conditions that the focus-film distance was 260 cm, the tube voltage was 90 kVp, the tube current was 270 mA, the exposure time was 0.31 sec, and the tube voltage ripple rate of X-ray generators was 0, the entrance surface dose reduction effect of the breast in the PA position was found to be 20.56 times lower than that of the AP position.

A Study on the Actual Conditions and Characteristics of Mammographic Units in Some Area (일부지역 유방촬영장치의 현황 및 특성에 관한 연구)

  • Park, Jin-Young;Baek, Seong-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.121-127
    • /
    • 2012
  • Of this study, it was found that there were 250 mammographic units in total installed and used in the areas for this study, and 36 units were used in general hospitals, 53 units in hospitals and 116 units in clinics. That is, the units in clinics accounted for 50% out of the whole units. As for the image acquisition method, it was found there were 131 units using F/S, 67 units using CR and 7 units using DR respectively. At present, F/S system was mainly used in the areas. As for the materials of target/filter, it was found that Mo/Mo was mostly used (66%), followed by Mo/Rh (25%). As for the size of focus, both 0.1 mm for small focus and 0.3 mm for large focus were mainly used for the units.

Fabrication of Film Bulk Acoustic Wave Filters with Ladder and Stacked Crystal Filter Types (Ladder 형과 SCF 형의 구조를 가지는 FBAR 필터의 제작)

  • ;;Mai Linh
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.630-632
    • /
    • 2003
  • In this paper, we present the fabrication and performance of FBAR filters with ladder and stacked crystal filter (SCF) types. The structure of the unit resonator in our work is the solidly mounted resonator (SMR) with W/SiO$_2$ multi-layer reflectors, the return loss of of which show -24dB at resonant frequency of -2.0GHz. The $K^2$eff, Q$_{s}$, and Q$_{p}$, indicating the performance of resonator were 3.24%, 6,363 and 6,749 and were calculated for the resonator with the resonance area of 21200${\mu}{\textrm}{m}$$^2$. Based on this unit resonator, FBAR filters with ladder and SCF types were fabricated and compared. The sizes of filters were 800$\times$2000(${\mu}{\textrm}{m}$$^2$) for the ladder type and 600$\times$500(${\mu}{\textrm}{m}$$^2$) for the SCF type.e..

  • PDF

Tunable bragg filter of $Si_3N_4-SiO_2$ waveguide using thermooptic effect (열광학 효과를 이용한 $Si_3N_4-SiO_2$ 도파로 가변 브래그필터)

  • 이형종;정환재
    • Korean Journal of Optics and Photonics
    • /
    • v.3 no.4
    • /
    • pp.244-251
    • /
    • 1992
  • Buried Bragg filters of single mode $Si_{3}N_{4}$ rib waveguide with a cover layer of $SiO_{2}$ and grating at the interface of $Si_{3}N_{4}$ and $SiO_{2}$ are designed and fabricated. Etching of the grating on $Si_{3}N_{4}$ waveguide core by buffered HF showed uniform etching with good control up to 1 nm. This buried type of Bragg filters are immune to contamination of the surface of device. The mode index and bandwidth of filters are determined by measurements of the transmission spectrum of Bragg filters and compared with that of calculation. Waveguide Bragg filters loaded with the micro-heater of Cr film and the cladding of silicone rubber are made to control the Brag wavelength of the filter. As a result the filter wavelength of the device moved by 0.41 nm for 10 mA current to the shorter side of wavelength proportional to the square of the current.

  • PDF

A study of Quality evaluation for medical linear accelerator using Electronic Portal Imaging (전자포탈영상 (EPI)을 이용한 의료용 선형가속기의 성능평가에 관한 연구)

  • 윤성익;권수일;추성실
    • Progress in Medical Physics
    • /
    • v.9 no.2
    • /
    • pp.105-113
    • /
    • 1998
  • Accurate radiation dosimetric characters is very important to determine of dose to a radiotherapeutic patient. Medical linear accelerators have been developed not only its new quality of convenient operation but also electric moderation. It is reliable to measure more detail physical parameter that linac's internal ability. Typically, radiation dosimetric tool is classified ionization chamber, film, thermoluminescence dosimeter, etc. Nowaday, Electronic Portal Imaging Device is smeared in radiation field to verification of treatment region. EPID's image was focused that using both on-line image verification and absolutely minimum absorbed dose during radiotherapy. So, Electronic Portal Imaging was tested for quality evaluation of medical linear accelerator had its pure conditional flash. This study has performed symmetry, Light/Radiation field congruence, and energy check, geometry difference on wedge filter using a liquid filled ion chamber (EPID). Prior to irradiated on EPID, high energy photon beam is checked with ion chamber. Using these results more convenient dosimetric method is accomplished by EPID that taken digital image. Medical image is acquired with EPID too. Therefore, EPID can be analyzed by numerical information for what want to see or get more knowledge for natural human condition.

  • PDF

Enhancing Adhesion between Polyphenylene Sulfide Fabric and Polytetrafluoroethylene Film for Thermally Stable Air Filtration Membrane (열안정 공기 여과막용 폴리페닐렌 설파이드 원단과 폴리테트라플루오로에틸렌 필름 사이의 접착력 향상)

  • Jin Uk Kim;Hye Jeong Son;Sang Hoon Kang;Chang Soo Lee
    • Membrane Journal
    • /
    • v.33 no.4
    • /
    • pp.201-210
    • /
    • 2023
  • Dust filter membranes play a crucial role in human life and various industries, as they contribute to several important aspects of human health, safety, and environmental protection. This study presents the development of a polysulfone@polyphenylene sulfide/polytetrafluoroethylene (PSf@PPS/ePTFE) composite dust filter membrane with excellent thermal stability and adhesion properties for high-temperature conditions. FT-IR analysis confirms successful impregnation of PSf adhesive onto PPS fabric and interaction with ePTFE support. FE-SEM images reveal improved fiber interconnection and adhesion with increased PSf concentration. PSf@PPS/ePTFE-5 exhibits the most suitable porous structure. The composite membrane demonstrates exceptional thermal stability up to 400℃. Peel resistance tests show sufficient adhesion for dust filtration, ensuring reliable performance under tough, high-temperature conditions without compromising air permeability. This membrane offers promising potential for industrial applications. Further optimizations and applications can be explored.

Fabrication of GHz-Band FBAR with AIN Film on Mo/SiO2/Si(100) Using MOCVD (Mo/SiO2/Si(100)기판 위에 MOCVD법으로 성장시킨 AIN박막이용 GHz대역의 FBAR제작에 관한 연구)

  • Yang, Chung-Mo;Kim, Seong-Kweon;Cha, Jae-Sang;Park, Ku-Man
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.4
    • /
    • pp.7-11
    • /
    • 2006
  • In this paper, it is reported that film-bulk-acoustic resonator with high c-axis oriented AIN film on $Mo/SiO_2/Si(100)$ using metal-organic-chemical-vapor deposition was fabricated. The resonant frequency and anti-resonant frequency of the fabricated resonator were observed with 3.189[GHz] and 3.224[GHz], respectively. The quality factor and the effective electromechanical coupling coefficient(${k_{eff}}^2$) were measured with 24.7 and 2.65[%], respectively. The conditions of AIN deposition were substrate temperature of $950[^{\circ}C]$, pressure of 20Torr, and V-III ratio of 25000. A high c-axis oriented AIN film with $4{\times}10^{-5}[\Omega{cm}]$ resistivity of Mo bottom electrode and $4[^{\circ}]$ of AIN(0002) full-width at half-maximum(FWHM) on $Mo/SiO_2/Si(100)$ was grown successfully. The FWHM value of deposited AIN film is useful for the RF band pass filter specification for GHz-band wireless local area network.

Effect of Surfactant Concentrations on Anti-waterdrop, Environment and Lettuce(Lactuca sativa L.) Growth in Polyethylene Film Greenhouse (계면활성제 처리 농도가 무가온 플라스틱온실의 방적성, 환경 및 상추 생육에 미치는 영향)

  • Chun, Hee;Lee, Hye-Eun;Yemm, Sung-Hyun;Kim, Hak-Ju;Lee, Si-Young;Nam, Yooun-Il;Kim, Kyung-Je
    • Journal of Bio-Environment Control
    • /
    • v.12 no.4
    • /
    • pp.195-199
    • /
    • 2003
  • In polyethylene film house treated with surfactants(SF316+FB0800), waterdrops attached on film surface were absorbed to filter paper of 9 cm in diameter and measured 1.21 mL in control, 0.15 mL in 1% and 0.07 mL in 2% on December 10 at 10:00, 2002. However, there was no clear difference between surfactant concentrations 1% and 2%, And the most waterdrop was measured at 10:00 in daytime. As the air temperature was higher in greenhouse, waterdrop was sweled. So, the least waterdrop was measured at 14:00. In greenhouse covered with surfactants concentrated 1% and 2%, transmittances of solar radiation were 9.3% and 12.9% higher than control, respectively. In air temperature and relative humidity, there were no significant difference in all greenhouse. in forenoon, the air temperature and relative surfactant treated film greenhouse tended 1~2$^{\circ}C$ warmer than that of control. However, sil temperatures of surfactant treated film greenhouse tended 3~4$^{\circ}C$ warmer than that of control. During winter, the lettuce growth in surfactant treated film greenhouse was faster than that of control. However, there was no difference between surfactant concentrations of 1% and 2%.