• Title/Summary/Keyword: filling performance

Search Result 391, Processing Time 0.034 seconds

Virtual View Generation by a New Hole Filling Algorithm

  • Ko, Min Soo;Yoo, Jisang
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.1023-1033
    • /
    • 2014
  • In this paper, performance improved hole-filling algorithm which includes the boundary noise removing pre-process that can be used for an arbitrary virtual view synthesis has been proposed. Boundary noise occurs due to the boundary mismatch between depth and texture images during the 3D warping process and it usually causes unusual defects in a generated virtual view. Common-hole is impossible to recover by using only a given original view as a reference and most of the conventional algorithms generate unnatural views that include constrained parts of the texture. To remove the boundary noise, we first find occlusion regions and expand these regions to the common-hole region in the synthesized view. Then, we fill the common-hole using the spiral weighted average algorithm and the gradient searching algorithm. The spiral weighted average algorithm keeps the boundary of each object well by using depth information and the gradient searching algorithm preserves the details. We tried to combine strong points of both the spiral weighted average algorithm and the gradient searching algorithm. We also tried to reduce the flickering defect that exists around the filled common-hole region by using a probability mask. The experimental results show that the proposed algorithm performs much better than the conventional algorithms.

Parallax Map Preprocessing Algorithm for Performance Improvement of Hole-Filling (홀 채우기의 성능 개선을 위한 시차지도의 전처리 알고리즘)

  • Kim, Jun-Ho;Lee, Si-Woong
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.10
    • /
    • pp.62-70
    • /
    • 2013
  • DIBR(Depth Image Based Rendering) is a kind of view synthesis algorithm to generate images at free view points from the reference color image and its depth map. One of the main challenges of DIBR is the occurrence of holes that correspond to uncovered backgrounds at the synthesized view. In order to cover holes efficiently, two main approaches have been actively investigated. One is to develop preprocessing algorithms for depth maps or parallax maps to reduce the size of possible holes, and the other is to develop hole filling methods to fill the generated holes using adjacent pixels in non-hole areas. Most conventional preprocessing algorithms for reducing the size of holes are based on the smoothing process of depth map. Filtering of depth map, however, attenuates the resolution of depth map and generates geometric distortions. In this paper, we proposes a novel preprocessing algorithm for parallax map to improve the performance of hole-filling by avoiding the drawbacks of conventional methods.

An experimental study on the performance of the separate type heat pipe in accordance with the refrigerant charge (냉매 충진량에 따른 분리형 히트파이프 성능에 관한 실험적 연구)

  • Jeon, Sung-Taek;Cho, Jin-Pyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.1600-1604
    • /
    • 2015
  • As modern houses are constructed with high-density and high-insulation, there is benefit to reduce energy consumption, but there are many side effects raised from polluted air. To solve the problem, a ventilation system is used to improve a indoor air quality. In this research, we experimentally estimate ventilation performance of HRV(heat recovery ventilator) with heat-pipe according to working fluid filling quantity and ventilation. Heat-pipe used in this study was designated separately to be applied to a ventilation system. The working fluid was R22, which was filled from 40 to 55 (%vol.) by 5(%vol.). Ventilation based on the front velocity was measured from 0.3 m/s to 1.5 m/s by 0.3 m/s intervals. Refrigerant filling quantity with the highest efficiency was found to depend on the ventilation. From this study the optimal refrigerant filling quantity in accordance with the ventilation of the detachable heat pipes was found experimentally.

Study on the Performance of the Separate type Heat Pipe Using the Parallel Flow type Heat Exchanger (평행류형 열교환기를 이용한 분리형 히트파이프의 성능에 관한 연구)

  • Jeon, Sung-Taek;Cho, Jin-Pyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5045-5050
    • /
    • 2015
  • As modern houses are constructed with high-density and high-insulation, there is benefit to reduce energy consumption, but there are many side effects raised from polluted air. To solve the problem, a ventilation system is used to improve a indoor air quality. In this study, we tested the parallel flow type heat exchanger used in a heat exchanger of an automotive air conditioner. And we experimentally estimate ventilation performance of HRV(heat recovery ventilator) with heat-pipe according to working fluid filling quantity and ventilation. The working fluid was R22, which was filled from 40 to 60 (%vol.) by 10(%vol.). Ventilation based on the front velocity was measured from 0.3 m/s to 1.5 m/s by 0.3 m/s intervals. Refrigerant filling quantity with the highest efficiency was found to depend on the ventilation. From this study the optimal refrigerant filling quantity in accordance with the ventilation of the detachable heat pipes was found experimentally.

A Stereo Matching Technique using Multi-directional Scan-line Optimization and Reliability-based Hole-filling (다중방향성 정합선 최적화와 신뢰도 기반 공백복원을 이용한 스테레오 정합)

  • Baek, Seung-Hae;Park, Soon-Young
    • The KIPS Transactions:PartB
    • /
    • v.17B no.2
    • /
    • pp.115-124
    • /
    • 2010
  • Stereo matching techniques are categorized in two major schemes, local and global matching techniques. In global matching schemes, several investigations are introduced, where cost accumulation is performed in multiple matching lines. In this paper, we introduce a new multi-line stereo matching techniques which expands a conventional single-line matching scheme to multiple one. Matching cost is based on simple normalized cross correlation. We expand the scan-line optimization technique to a multi-line scan-line optimization technique. The proposed technique first generates a reliability image, which is iteratively updated based on the previous reliability measure. After some number of iterations, the reliability image is completed by a hole-filling algorithm. The hole-filling algorithm introduces a disparity score table which records the disparity score of the current pixel. The disparity of an empty pixel is determined by comparing the scores of the neighboring pixels. The proposed technique is tested using the Middlebury and CMU stereo images. The error analysis shows that the proposed matching technique yields better performance than using conventional global matching algorithm.

Experimental Study on the Development of High-Performance Concrete (Properties of Super-flowing Concrete) (고성능 콘크리트 개발에 관한 실험적 연구(제2보, 초유동 콘크리트의 기초물성))

  • 조일호;한정호;정재동
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1993.10a
    • /
    • pp.51-56
    • /
    • 1993
  • This is a part a study on the development of High-Performance Concrete ; about experimental results from several test methods to estimate workability in fresh concrete and influences of concrete mix design that affects properties of super-flowing concrete. Super-flowing concrete can be filled in a formwork without any vibration because of its excellent workability of passing narrow space and filling complicated shaped mold, new test methods should be used to estimate the workability and rhelogy in super-flowing concrete instead of slump test method in conventional concrete.

  • PDF

Analysis of Back-to-back Refueling for Heavy Duty Hydrogen Fuel Cell Vehicles Using Hydrogen Refueling Stations Based on Cascade System (캐스케이드 시스템 기반 수소 충전소를 이용한 대형 수소 연료 전지 차량 연속 충전 분석)

  • GYU SEOK SHIM;BYUNG HEUNG PARK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.35 no.3
    • /
    • pp.300-309
    • /
    • 2024
  • Hydrogen utilization in the transportation sector, which relies on fossil fuels, can significantly reduce greenhouse gas by using to hydrogen fuel cell vehicles, and its adoption depends performance of hydrogen refueling station. The present study developed a model to simulate the back-to-back filling process of heavy duty hydrogen fuel cell vehicles at hydrogen refueling stations using a cascade method. And its quantitatively evaluated hydrogen refueling station performance by simulating various mass flow rates and storage tank capacity combinations, analyzing vehicle state of charge (SOC) of vehicles. In the cascade refueling system, the capacity of the high-pressure storage tank was found to have the greatest impact on the reduction of filling time and improvement of efficiency.

Effects of Working Fluid Filling Ration and Heat Flux on Correlations of Heat Transfer Coefficient in Loop Thermosyphon

  • Chang, Ki-Chang;Lee, Young-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.10 no.3
    • /
    • pp.153-161
    • /
    • 2002
  • Due to the coupling between momentum and energy transport theoretical analysis of the loop performance is very complicate, therefore it is necessary that these problems be solved by experimental investigation before applying the loop thermosyphon to heat exchanger de-sign. The evaporator and condenser of the loop thermosyphon were made of carbon-steel, and distilled water was used as working fluid in the experiments. From the experimental data correlations of heat transfer coefficient for evaporator and condenser sections were obtained. For heat fluxes in the range of 13000~78000 W/$m^2$, the correlation equations of heat transfer coefficients in evaporator and condenser predict the experimental behavior to within $\pm$5% and $\pm$20% respectively.

Effect of Quantity of Working Fluid on Performance of a Heat Pipe (히트 파이프의 작동유체 충전량이 성능에 미치는 영향)

  • Shin, D.Y.;Ro, S.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.1 no.4
    • /
    • pp.313-318
    • /
    • 1989
  • Experiments have been performed to find an optimum filling quantity of working fluid in a heat pipe. The optimum operation has been defined to give a minimum temperature difference between evaporator and condenser. The experimental results show that there exists an optimum filling quantity which is slightly smaller than that calculated by the well known formula from the geometry of the wick. When the concaved vapor-liquid interface at the wick is taken into account to calculate the required quantity of working fluid, the computed value agrees with the experimentally determined quantity.

  • PDF

Reinforcement of underground cavities by Hi-FA(High performance and Multi functional Agent) (Hi-FA(유동성 및 점성 개질제)를 이용한 지하공동 보강사례)

  • Lim, Hai-Sik;Park, Yeung-Ho;Paik, Kyu-Ho;Lee, Yong-Jun;Park, Su-Yong
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.676-686
    • /
    • 2010
  • Damage Cases of variously type are reported that the ground subsidence is caused by the underground cavities at structure and construction works in lime stone or abandoned zone. A underground cavities by direct for zone having an effect on structure have been filled with cement agents. But this measure is urgently needed in materials and work methods, because ground water pollution at water down fillings and flow out, ground disturb at high participle, damage of farms and fishery. The research confirm application of filling method and filling materials of environmentally friendly and economical by Hi-FA new materials have both liquidity and viscosity from case reinforcement in APT site, Gunsan.

  • PDF