• Title/Summary/Keyword: field static test

Search Result 254, Processing Time 0.025 seconds

Dynamic and static structural displacement measurement using backscattering DC coupled radar

  • Guan, Shanyue;Rice, Jennifer A.;Li, Changzhi;Li, Yiran;Wang, Guochao
    • Smart Structures and Systems
    • /
    • v.16 no.3
    • /
    • pp.521-535
    • /
    • 2015
  • Vibration-based monitoring is one approach used to perform structural condition assessment. By measuring structural response, such as displacement, dynamic characteristics of a structure may be estimated. Often, the primary dynamic responses in civil structures are below 5 Hz, making accurate low frequency measurement critical for successful dynamic characterization. In addition, static deflection measurements are useful for structural capacity and load rating assessments. This paper presents a DC coupled continuous wave radar to accurately detect both dynamic and static displacement. This low-cost radar sensor provides displacement measurements within a compact, wireless unit appropriate for a range of structural monitoring applications. The hardware components and operating mechanism of the radar are introduced and a series of laboratory experiments are presented to assess the performance characteristics of the radar. The laboratory and field experiments investigate the effect of factors such as target distance, motion amplitude, and motion frequency on the radar's measurement accuracy. The results demonstrate that the radar is capable of both static and dynamic displacement measurements with sub-millimeter accuracy, making it a promising technology for structural health monitoring.

A Characteristics of Bearing Capacity by PG Pile on Waste Landfill (폐기물 매립지반에서 PG Pile의 지반지지력 특성)

  • 천병식;최춘식
    • Journal of the Korean Society for Railway
    • /
    • v.3 no.4
    • /
    • pp.213-218
    • /
    • 2000
  • Waste landfill is so loose that it may cause the insufficient bearing capacity and the differential settlement. And so, characteristics and conditions of the ground should be considered in applications of ground improvement in waste landfill. In this paper, analysis of field tests as the static loading test and the bearing capacity test were performed. In result, PG(Pack Grouting) pile method is proved effective and economic, because it could bring about the increase of end bearing capacity, the prevention of differential settlement and increase of density by expansion of pile.

  • PDF

A Study on the Utilization of PG-Pile in waste landfill (폐기물 매립지반에서의 PG Pile의 적용성에 관한 연구)

  • 천병식;최춘식
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.419-426
    • /
    • 2000
  • Waste landfill consists of cover layer, glass, robber, sheet, food waste, etc and is in very loose state. So, the proper method must be applied to ground improvement of waste landfill according to its characteristics and conditions. In this paper, analysis for field tests as static loading test, bearing capacity test were peformed. In result, PG pile method proved to be effective and economic, because it affected increase of end bearing capacity, the prevention of differential settlement and over 20% increase of density by expansion of pile.

  • PDF

A Study on the Utilization of PG-Pile in Waste Landfill (폐기물 매립지반에서의 PG Pile의 적용성에 관한 연구)

  • 천병식;최춘식
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2000.10a
    • /
    • pp.135-139
    • /
    • 2000
  • Waste landfill consists of cover layer, glass, robber, sheet, food waste, etc and is in very loose state. So, the proper method must be applied to ground improvement of waste landfill according to its characteristics and conditions. In this paper, analysis for field tests as static loading test, bearing capacity test were performed. In result, PG pile method proved to be effective and economic, because it affected increase of end bearing capacity, the prevention of differential settlement and over 20% increase of density by expansion of pile.

  • PDF

A Field Test Study on stress concentration ratio of Crushed-Stone Column Pile (쇄석다짐말뚝의 응력분담비에 관한 현장실험 연구)

  • Lee, Min-Hee;Im, Jong-Chul;Hwang, Geun-Bae;Choi, Yong-Kyu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.525-532
    • /
    • 2004
  • Among soft ground treatment methods with granular soil used in domestic, the sand compaction pile method has been utilized greatly, but, as a result of exhaustion of sand and increase of unit cost, a necessity of an alternative method is suggested. In this study, the static load tests for crushed-stone compaction piles which were constructed on test field were performed. Based on test results, stress concentration ratios between the crushed-stone compaction pile and the soft ground were investigated and estimated. The stress concentration ratio was the range of 1.7 to 3.0 and the higher it was the more replacement rate was increased.

  • PDF

Development of an efficient 3-node plate bending element by using the Hellinger-Reissner functional (Hellinger-Reissner 범함수를 이용한 효율적인 3절점 판 유한요소의 개발)

  • Lee, Youn-Gyu;Choi, Chang-Koon;Lee, Phill-Seung
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.760-763
    • /
    • 2011
  • 본 논문의 목적은 효율적인 3절점 판 유한요소를 개발하는 것이다. Hellinger-Reissner 범함수에 근거한 혼합정식화(mixed formulation)를 사용한다. 잠김현상을 일으키는 전단변형률장을 독립적으로 분리한 후, MITC(Mixed Interpolation of Tensorial Components)방법을 이용하여 대체전단변형률장(assumed transverse shear strain field)을 구성한다. 추가적으로 회전된 반변기저벡터(contravariant base vector)로 정의된 근사전단변형률장(approximated transverse shear strain field)에 미지수(unknowns)를 도입하여 혼합정식화를 완성시키고 정적응축(static condensation)을 통해 최종 강성행렬을 구성한다. 거짓영에너지모드시험(spurious zero energy mode test), 조각시험(patch test), 등방성시험(isotropic test) 등을 실시하였으며, 4변 완전구속 정사각형 판 구조물과 60도 기울어진 단순지지 판 구조물 등 예제들을 해석하여 MITC3판 유한요소와 수렴성능을 비교하였다.

  • PDF

A Study on the Strain Measurement of Concrete Pavement Slab (콘크리트 포장 슬래브의 변형률 측정에 관한 연구)

  • Kim, Dong-Ho;Jeon, Sung-Il;Choi, Chang-Sik;Yun, Byeung-Sung;Yun, Kyong-Ku
    • Journal of Industrial Technology
    • /
    • v.22 no.A
    • /
    • pp.169-176
    • /
    • 2002
  • The purpose of this paper is to investigate for strain measurement of concrete pavement slab at field. The early-age behaviors of concrete pavement were measured using the strain gages. From the static and dynamic wheel loading tests, the outputs from each gages were recorded. The measured data, also, was compared to those from finite element analysis. The static wheel loading tests were performed in twice, and the dynamic wheel loading tests were performed at the speed 10km-50km. The results could be summarized as follows: To embed the strain gage accurately and stably in concrete pavement, a chair and protective box must be used. The protective box must not be affected from the outside vibrating. From the results of early-age stram measurement, it was found that the strain varied at the maximum value of $180{\mu}{\varepsilon}$ From the results of static wheel loading tests, A1, A2 and B gages generally developed a consistent tendency When comparing the results from the measured at field and the calculated by FEM analysis, the data of A1 and B gages were similar to that from theory. The values from the field test were generally higher than that from the theory. From the results of dynamic wheel loading tests, it was known that the measured strain at field became smaller as the truck speed became faster, Indicating the maximum at the range of $12{\sim}13{\mu}{\varepsilon}$.

  • PDF

Development of Displacement Estimation Technique for Bridges Located under Poor Measurement Circumstances (계측이 어려운 환경에 가설된 교량의 변위 추정 기술 개발)

  • Jeon, Junchang;Lee, Heehyun
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.6
    • /
    • pp.755-764
    • /
    • 2016
  • In this paper, to verify the field application of a displacement estimation technique based on the relationship between displacement and strain, static and dynamic field load test are performed on three-span continuous real bridge structures. The superstructure types of the test bridges are IPC girder highway bridge and steel box girder AGT bridge. LVDTs and strain gauges are attached to them; then, the responses due to test vehicle are measured. To obtain the displacement-strain relationship of the test bridges, the bridges are modeled as grillage system with 6 DOFs for the purpose of structural analyses. Static and dynamic displacements, which are estimated using both the calculated displacement-strain relationship and the measured strain signal, agree well with the values measured by LVDT. This study demonstrates that the displacement estimation technique using the strain signal can be effectively applied to the displacement measurement of bridge structures that cross rivers/roads/railways or have high clearance.

A Experimental Study on the Structural Performance of Precast Bracket under Precast Road Deck Slab of Double Deck Tunnel (복층터널에서 도로용 중간슬래브와 연결되는 조립식 브라켓의 구조성능에 관한 실험연구)

  • Kim, Bo Yeon;Lee, Doo Sung;Kim, Tae Kyun;Kim, Young Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.4
    • /
    • pp.647-657
    • /
    • 2017
  • The main purpose of this study is to investigate the static & dynamic behavior of a precast bracket under precast road deck slab of double deck tunnel. In order to improve the construction speed, the field prefabricated bracket to connect the intermediate slab to the precast shield tunnel lining structure has been developed in the 'SPC (Steel Precast Concrete) bracket'. The experiments were performed for the full scale model in order to evaluate the performance of the 'SPC bracket', the structural stability was verified through the FEM analysis. The result of static loading test, no deformations or cracks of the bracket undergo the ultimate load was investigated. In addition, no pulling or deformation of the chemical anchor for fixing the bracket was measured. As a result of dynamic loading test, it was investigated that there is no problem in the chemical anchor for fixing the bracket. FEM analysis showed similar behavior to static load test and it was determined that there is no problem in serviceability and structural safety.

A study on the electromagnetic field distributions in a W-TEM cell having wire array as an inner conductor (와이어 어레이 형태의 내부 도체를 갖는 W-TEM cell의 전자계 분포 특성에 관한 연구)

  • 김명훈;이중근
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.6
    • /
    • pp.1576-1586
    • /
    • 1996
  • The subject of this paper is the analysis of a Wire-TEM cell(W-TEM cell) which has an inner wire array rather than a metallic septum;its basic structure is similiar to a NBS TEM cell. To verify improved performances of this W-TEM cell as a standard EM field generator, well-known quasi-static approximations are employed and their resultant ingegral equations are numerically analyzed by moment method. Although the electric field strength of a W-TEM cell is 1.4 dB lower than tht of a NBS TEM cell, the uniformity of EM field patterns in a W-TEM cell is improved. It is also shown that the EM field distortions resulting from loading by the conditing objects under test(loading effects), are decreased considerably. This paper also deals with the investigations about relationship between the EM field distributions and the number of wire composing the inner conductor. Finally, the experimental analysis is performed on the practical model which is built on the basis of the design variables brought out by the theoretical andnumerical analysis.

  • PDF