• Title/Summary/Keyword: field permeability test

Search Result 173, Processing Time 0.029 seconds

Interactive Effects of UV-B and Pesticides on Photosynthesis and Nitrogen Fixation of Anabaena doliolum

  • Chandrai, Lar;Vandana, Pandey
    • Journal of Microbiology and Biotechnology
    • /
    • v.12 no.3
    • /
    • pp.423-430
    • /
    • 2002
  • The effects of UV-B and commercial grade pesticides (butachlor and carbofuran), individually and in combination, were studied on a variety of physiological processes of rice field cyanobacterium Anabaena doliolum. Butachlor was found to be $2-12\%$ more toxic than carbofuran and $4-24\%$ than UV-B on the growth, photosynthesis, lipid peroxidation, membrane permeability, and nitrogenase activity of the test cyanobacterium. Of the three photosynthesis inhibitors, the butachlor-induced inhibition of whole chain was approximately 3 and $21\%$ higher than carbofuran and UV-B, respectively. Although the interaction of the stress factors caused a significant inhibition (P<0.01), it was still less than the additive effect on the parameters investigated, except for PSI.

The Study on permeability enhancement in smear zone using electro-osmotic pressure (전기 삼투압을 이용한 교란영역의 투수성 개선에 관한 연구)

  • Ahn, Byung-Wook;Noh, Hee-Jeon;Kim, Hyun-Ki;Cho, Nam-Jun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.435-441
    • /
    • 2008
  • More time is required for consolidating soft clay when its hydraulic conductivity around the vertical drains is reduced by soil disturbance. One of the methods to be proposed to solve such problem is the electro-osmotic flow application. This study presents the experimental results of model tests using a modified oedometer and a large-scale cylinder with a sand drain. Results show that the development of negative excessive pore water pressure due to the DC electrical field in saturated clay can be transformed to additional loads causing more consolidation settlement.

  • PDF

Effect of Leakage on Deterioration of Concrete Lining Structure (콘크리트 라이닝 구조물의 누수에 의한 열화특성)

  • Jung, Ho-Seop;Kim, Dong-Cyou;Kim, Seong-Soo;Park, Kwang-Pil
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.287-288
    • /
    • 2009
  • In this study, the degree of deterioration on the tunnel lining concrete due to crack and leakage was evaluated by field-investigating the conventional tunnels constructed a long time ago. By examining the exterior, conducting the non-destructive test and collecting cores for the tunnel concrete linings, this study evaluated the compressive strength and the permeability, and also performed instrumental analyses.

  • PDF

Quality and Measure Controls for Plastic Board Drains Method (PBD공법의 품질 및 계측관리)

  • 박영목
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.10a
    • /
    • pp.133-145
    • /
    • 2001
  • This paper presents quality and measure controls of Plastic Board Drains(PBD) for improvement of soft ground. Laboratory and field tests has been carried out to evaluate the quality of PBD focussing on : discharge capacity of flow area; permeability of filter sleeve; migration of fine particles; deformed shape of PBD; consolidation of clay in the close vicinity of PBD; tensile strength of PBD; long-term consolidation behavior of clay-PBD. Test results show that the quality of PBD is sufficient to perform the improvement of soft silty and clayey ground. But, geotechnical engineer must make efforts minimizings of PBD damage and ground disturbance, continuity of drainage system during construction. Adequate monitoring system should apply at ground focussing on number, location, and accuracy of geotechnical instrumentation, measurement and evaluation of data for ground behaviour.

  • PDF

Selectivity and structural integrity of a nanofiltration membrane for treatment of liquid waste containing uranium

  • Oliveira, Elizabeth E.M.;Barbosa, Celina C.R.;Afonso, Julio C.
    • Membrane and Water Treatment
    • /
    • v.3 no.4
    • /
    • pp.231-242
    • /
    • 2012
  • The performance of a nanofiltration membrane for treatment of a low-level radioactive liquid waste was investigated through static and dynamic tests. The liquid waste ("carbonated water") was obtained during conversion of $UF_6$ to $UO_2$. In the static tests membrane samples were immersed in the waste for 24, 48 or 72 h. The transport properties of the samples (hydraulic permeability, permeate flow, selectivity) were evaluated before and after immersion in the waste. In the dynamic tests the waste was permeated in a permeation flow front system under 0.5 MPa, to determine the selectivity of NF membranes to uranium. The surface layer of the membrane was characterized by zeta potential, field emission microscopy, atomic force spectroscopy and infrared spectroscopy. The static test showed that the pore size distribution of the selective layer was altered, but the membrane surface charge was not significantly changed. 99% of uranium was rejected after the dynamic tests.

Evaluation of Durability Performance of Wet- Mixed Shotcrete with Powder Types Cement Mineral Accelerator (시멘트 광물계 급결제를 사용한 습식 숏크리트의 내구성 평가)

  • Won Jong-Pil;Sung Sang-Kyoung;Park Chan-Gi;Cho Yong-Jin;Choi Seok-Won;Park Hae-Geun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.253-256
    • /
    • 2004
  • Recently, construction works of scale are getting larger with economic growth. Shotcreting is one of major processes in tunnels construction. Accelerator is used in tunnel and underground structures to ensure early strength of shotcrete. Silicate based accelerator and aluminate based accelerator is getting widely in the field. But these accelerators have many problems due to decesase of long-term strength and low quality of the hardened shotcrete. in order to solve these problems, recently developed powder types cement mineral accelerator. In this study, we tested chloride permeability, freezing and thawing and accelerated carbonation of shotcrete. As a result of the test, wet-mixed shotcrete with powder types cement mineral accelerator exhibited durability improvement compared to the conventional shotcrete accelerator.

  • PDF

A Study on the Grouting for the Underpinning of Open Caisson of Existing Bridge (기존 교량구조물의 유지관리를 위한 우물통 기초 보강주입에 관한 연구)

  • Chun, Byung-Sik;Yeoh, Yoo-Hyeon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.1
    • /
    • pp.131-138
    • /
    • 2000
  • In this study, physical and engineering properties of ordinary portland cement and microcement were investigated to verify reinforcing effect of underpinning of open caisson foundation by using microcement grouting. Laboratory injection tests such as infiltration and injection in case of seepage for the stream bed soil at ${\bigcirc}{\bigcirc}$ Great Bridge in Seoul were carried out. Field injection tests to reinforce open caisson foundation at ${\bigcirc}{\bigcirc}$ Great Bridge were performed and the ability of application by microcement grouting was evaluated. From the test results, physical and engineering properties of microcement are better than those of ordinary portland cement. Also, the ability of infiltration and solidity in case of seepage is better than that of ordinary portland cement. Therefore, it is concluded that microcement is an excellent material to reinforce open caisson foundation of the existing bridge structure under the water and can be used as underpinning material of general foundations.

  • PDF

Development of Bentonite Composite Liners for Waste Landfill Sites (폐기물매립지 침출수 누출방지용 벤토나이트 복합라이너 개발)

  • Choi, Woo-Zin;Jin, Sung-Ki;Ha, Hun-Jung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.1 no.1
    • /
    • pp.65-70
    • /
    • 2000
  • Recently, soil-bentonite mixtures are frequently used as impervious liners for waste disposal sites. In the present work, bentonite composite liner systems have been developed by utilizing Korean zeolitic bentonites. The geomechanical properties of the liner systems, such as strength hydraulic conductivity, etc. have also been studied. The laboratory and field test results showed that uniaxial strengths of the system were improved by addition of bentonite and CaO-based additive to the upper and lower layer of the liner systems, respectively. Hydraulic conductivity values measured on field liner systems showed less $1{\times}10^{-3}cm/s$, which is considered to be minimum regulation requirement for waste disposal sites.

  • PDF

A Field Verification Study on the Effect of Filter Layers on Groundwater Level Drop Characteristics, Permeability, Optimum Yield and Well Efficiency in the Unconfined Aquifer Well for Riverbank Filtration Intake (강변여과수 취수를 위한 충적우물에서 필터층이 수위강하특성, 투수성, 적정양수량 및 우물효율에 미치는 영향에 대한 현장실증 연구)

  • Song, Jae-Yong;Lee, Sang-Moo;Kang, Byeong-Cheon;Lee, Geun-Chun;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.29 no.4
    • /
    • pp.509-529
    • /
    • 2019
  • This study performs to evaluate the role of filter material at alluvial well for intake of riverbank filtration and the applicability and improvement effect of dual filter well. To achieve this objective, dual filter intake well and single filter intake well were installed with different filter conditions at riverbank free surface aquifer in soil layer then we evaluated filter material condition, permeability, optimum yield and well efficiency according to yield in drawdown test. As a results, we assumed forming dual filter layer minimizes sudden speed changes at boundary between aquifer and filter layer by cushioning of groundwater flow. This suppresses warm current then intake groundwater efficiently, therefore it seems decreasing peripheral groundwater level changes in spite of higher intake water amount than single filter intake well. Furthermore, we confirmed by test, installing dual filter improves permeability, optimum yield and well efficiency. The result will be used by combining with former study to set up standard of design/construction of dual filter intake well at alluvial aquifer layer. Furthermore, we expect this result will be used to prove application effect of dual filter intake well compared to single filter one and radial collector well which are mainly applied on riverbank filtration.

Maintenance of Infiltration-type Facilities for Non-point Source Pollutant (침투형 비점오염원 처리시설의 유지관리에 관한 연구)

  • Lee, Hosik;Lee, Sanghwan
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.2
    • /
    • pp.145-152
    • /
    • 2013
  • This study was conducted to improve the Nonpoint-source pollutant treatment plant efficiency and maintenance. Field and laboratory permeability test were conducted three times each before and after displacement. The removal efficiency such as TSS, BOD, CODmn, T-N, and T-P were investigated from the year of 2006 to 2011. The coefficient of permeability right after displacement was calculated to be $1.07{\times}10^{-3}(cm/s)$, coefficient of permeability after a year was calculated to be $0.88{\times}10^{-3}(cm/s)$, and after five years, it was calculated to be $0.3{\times}10^{-3}(cm/s)$ and accordingly, the amount of infiltration decreased. In case of the removal efficiency, it generally tended to decrease, but it showed the higher rates than the expected rates BOD 40%, SS 76%, T-N 39% and T-P 53%. It is concluded that displacement cycle should be at least five years and that dredging cycle should be at least three months and at most one year.