• 제목/요약/키워드: field of energy

검색결과 5,815건 처리시간 0.034초

A Study of Correlation between SPT N-value and Exerted Electrical Energy Required for Ground Drilling II : Application Study (Field Pilot Test) (지반굴착에 소요되는 전기에너지와 표준관입시험 N값과의 상관관계 연구 II : 적용성 평가(현장시험시공))

  • Choi, Changho
    • Journal of the Korean Geosynthetics Society
    • /
    • 제11권4호
    • /
    • pp.55-62
    • /
    • 2012
  • In this application study, field pilot tests were performed to evaluate the validity of a proposed formula between the exerted electrical energy and SPT N-value based on the result of the basic study. Measurement sensors and recording system were developed to obtain exerted motor current and drilling depth in a field. By using the correlation formula proposed in the basic study, the measured motor current and boring speed were applied to predict SPT N-value and the predicted N-values were compared to SPT N-value of site exploration. From the comparisons it is verified that the exerted electrical energy to bore ground might be used to predict SPT N-value and pile tip location.

Intelligent Conponent (인텔리전트 컨포넌트 (Intelligent Conponent))

  • Mizutaka, Jun;Seo, Gil-Jin
    • Proceedings of the SAREK Conference
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.103-108
    • /
    • 2008
  • Automatic control makes the air-handling unit go into operation and determines the functions of high-efficient and energy-saving machines. Yamatake, an automatic control system manufacturer, have expanded fault detection and diagnosis, and data volumes so as to achieve higher technology in control by developing a sensor which makes field data visible, an actuator and Intelligent Conponent. This study, thus, focuses on applications for saving energy with Intelligent Conponent and goes in for easing global warming by creating future field data-based applications.

  • PDF

Extension of Field-Consistency to Plane Strain Elements (일관장 개념의 평면변형률 요소에의 확장)

  • 김용우
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • 제19권8호
    • /
    • pp.1799-1809
    • /
    • 1995
  • The applicability of the field-consistency paradigm, which was originally employed for analysis of locking due to constrained energy having the second power of a strain, is extended to the constrained energy having a quadratic form of strain. For the extension, nearly-incompressible plane strain problem is considered by introducing the concept of reduced minimization. The field-consistent analysis of the plane strain problem leads to a clear and systematic understanding on the relation amongst constraints imposed on element, spurious constraint -free optimal points, and integration order used.

Numerical Study of Inflation of a Dipolar Magnetic Field by Injecting Plasma with Different Beta

  • Kajimura, Yoshihiro;Funaki, Ikkoh;Shinohara, Iku;Usui, Hideyuki;Nakashima, Hideki
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.553-556
    • /
    • 2008
  • A Magneto Plasma Sail(MPS) produces propulsive force by the interaction between the solar wind and an artificial magnetic field inflated by injecting plasma. Using a 2D hybrid PIC code, we evaluate the inflation of magnetic field when Argon(Ar) plasma with different ${\beta}_{in}$ including the value less than one is injected into the dipolar magnetic field generated by a superconducting coil. It is found that the magnetic field can be inflated by injecting plasma within an angle of $30^{\circ}$ in the polar direction and the magnetic field decays in the polar direction according to $B{\propto}r^{-2.4}$ after the plasma(${\beta}_{in}$=0.1) is injected.

  • PDF

Performance of Non Punch-Through Trench Gate Field-Stop IGBT for Power Control System and Automotive Application

  • Kang, Ey Goo
    • Transactions on Electrical and Electronic Materials
    • /
    • 제17권1호
    • /
    • pp.50-55
    • /
    • 2016
  • In this paper, we have analyzed the electrical characteristics of 1200V trench gate field stop IGBT and have compared to NPT planar type IGBT and NPT planar field stop IGBT. As a result of analyzing, we obtained superior electrical characteristics of trench gate field stop IGBT than conventional IGBT. To begin with, the breakdown voltage characteristic was showed 1,460 V and on state voltage drop was showed 0.7 V. We obtained 3.5 V threshold voltage, too. To use these results, we have extracted optimal design and process parameter and designed trench gate field stop IGBT. The designed trench gate IGBT will use to inverter of renewable energy and automotive industry.

Analysis of the Thermal Environment and Natural Ventilation for the Energy Performance Evaluation of the Double Skin System during the Summer (이중외피 시스템의 에너지성능평가를 위한 하절기 열환경 및 자연환기 분석)

  • Eom, Jung-Won;Cho, Soo;Huh, Jung-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • 제22권4호
    • /
    • pp.68-76
    • /
    • 2002
  • This paper discusses thermal and ventilation performance which might be caused by the adoption of one of specific building facade techniques, Double Skin System(DSS). One building with a prototypical DSS was selected and systematically investigated through field monitoring and computer simulation techniques. A network model of ventilation was successfully made using COMIS to evaluate ventilation performance of the system which can hardly be done by field measurements. Various operating conditions of air conditioning on/off and window opening were implemented in this type of building. Through the appropriate operation of the DSS in summer, simulation-based and experimental results implicate that it can lead to cooling energy savings.

A Study on the Improvement of Energy Performance in School Buildings (학교건물의 에너지 성능개선에 관한 연구)

  • 박진철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제16권1호
    • /
    • pp.54-61
    • /
    • 2004
  • The purpose of this study is to improve of energy performance in school buildings. Many building renovations have mainly focused on commercial buildings and houses, but school buildings have no attention in this field although there are many buildings that show degraded energy performance and there are many old fashioned buildings which need renovation. This study was carried out through the survey, field study, energy simulation and life cycle cost analysis. The results of this study can be summarized as follows: In model building, large amount of heat were lost at the building envelope, such as non-insulated skins, window-sills and window-frame joints. According to the simulation result, about 15% of heating energy is saved by the insulating works compared to pre-renovation condition. Also, LCC analysis revealed to be more effective to select a exteria wall insulation such as a dryvit system.

Mesoscale Simulation of Polymeric Membranes for Energy and Environmental Application (에너지-환경 분야용 분리막의 Mesoscale Simulation 동향 연구)

  • Park, Chi Hoon;Nam, Sang Yong
    • Membrane Journal
    • /
    • 제27권2호
    • /
    • pp.121-128
    • /
    • 2017
  • Mesoscale simulation is a type of molecular simulation techniques where groups of atoms are defined as a single bead for calculations, and accordingly, is possible to simulate longer time ($ns{\sim}{\mu}s$) and bigger size ($nm{\sim}{\mu}m$). There are two types of mesoscale simulations : (1) particle-based mesoscale which simulates the system by calculating the movement of the particles themselves and (2) field theory which simulates the system by calculating changes in the chemical potential filed or density field. Mesoscale simulations are powerful tools to study the macroscopic properties of polymers for various applications of energy and environment. In this review, we report the trends and useful information in mesoscale simulation and provide an opportunity for membrane researchers working in the energy-environment field to understand mesoscale simulation techniques.

Electron Emission Theory for LCD Backlight

  • Kim, Hee-Tae;Lee, Dong-Chin;Nam, Seok-Hyun;Jang, Tae-Seok
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.1602-1605
    • /
    • 2008
  • We considered most general electron emission caused by temperature as well as electric field with a free electron gas model. The total electron emission current density comes from field emission effect where electron energy is lower than vacuum and from thermionic emission effect where electron energy is higher than vacuum. The total electron emission current density is shown as a function of temperature for constant electric field, and as a function of electric field for constant temperature.

  • PDF

Field Test for a Biological Nitrogen Treatment System with Low Temperature Solar Thermal Energy (저온 태양열을 이용한 생물학적 오수 처리 장치 실증 실험)

  • Chung, Mo;Lee, Dong-Won
    • Journal of the Korean Solar Energy Society
    • /
    • 제28권2호
    • /
    • pp.34-41
    • /
    • 2008
  • A low-temperature solar thermal system assisting a biological nitrogen treatment reservoir was designed and field-tested. A large tank whose temperature was maintained at about $25-30^{\circ}C$ to enhance the performance of a biological nitrogen treatment process was heated by an array of flat plate solar collectors. Test results revealed that the overall collector efficiency was above 50% for the most cases tested. This high efficiency was possible owing to the relatively low collector temperature that can be traced back to the reservoir temperature. A substantial enhancement in nitrogen treatment was observed as a result of maintaining the reservoir temperature higher.