• 제목/요약/키워드: field measuring data

검색결과 582건 처리시간 0.032초

터널 굴착에 따른 지반 및 인접구조물의 3차원 거동 (3-D Behavior of Adjacent Structures in Tunnelling Induced Ground Movements)

  • 김찬국;황의석;김학문
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.663-670
    • /
    • 2003
  • Urban tunnelling need to consider not only the stability of tunnel itself but also the ground movement regarding adjacent structures. This paper present 3-D behavior of adjacent structures due to tunnelling induced ground movements by means of field measuring data and nonlinear FEM tunnel analysis. The results of the analytical methods from Mohr-Coulomb model are compared with the site measurement data obtained during the twin tunnel construction. It was found that the location and stiffness of the structure influence greatly the shape and pattern of settlement trough. The settlement trough for Greenfield condition was different from the trough for existing adjacent structures. Therefore the load and stiffness of adjacent structures should be taken into account for the stability analysis of the structures.

  • PDF

태양전지 전원 공급장치를 이용한 발파진동 자동화 계측시스템 운영 사례연구 (A Case Study of the Automatical Blasting Vibration Measuring System Using the Solar Power Supply)

  • 유지완;이태노;김정렬;김영석
    • 화약ㆍ발파
    • /
    • 제26권2호
    • /
    • pp.92-98
    • /
    • 2008
  • 발파진동 계측방법은 일반적으로 수동식 방법과 자동화 방법으로 나눌 수 있다. 이중에서 자동화 계측방법은 계측원의 수동적 작동에 의한 방법에 의존하지 않고 별도의 공간(사무실 등)에서 원격장치를 이용하여 진동측정기를 작동시켜 데이터를 전송받게 된다. 본 연구에서는 태양전지를 이용한 발파진동 자동화 계측시스템 운영 연구사례를 소개하고자 한다. 향후, 계측원 접근이 어렵고 발파작업중에 진동값 변화추이를 수시로 관찰이 필요한 현장에서는 이와 같은 쏠라셀을 이용한 자동화 계측시스템이 매우 유용하게 활용될 수 있으며 발파진동 제어와 안전발파 관리가 효과적으로 이루어질 수 있을 것으로 사료된다.

광촉침법에 의한 비접촉 3차원 형상측정에 관한 연구 (A Study on Non-contact Measurement of 3D-Objects by Optical Probe Method)

  • 강영준;신성국;삼호융지
    • 한국정밀공학회지
    • /
    • 제12권4호
    • /
    • pp.119-126
    • /
    • 1995
  • This paper presents a non-contact measuring system using one point measuring method to measure surface profiles of dies and clay models for practical use in the field of production engineering. The system has a laser beam probe similar to a measuring probe in a contact measuring system and CCD linear sensor used to detect 300mm measurement range, displacement of measured surfaces, from an origin. There is no mechanical interference between this measuring system and a measured surface in this system. In this measuring system, it was needed 500-600ms including data processing time to measure one point. The experiments showed that the standard deviation was 800 .mu.m and the reproducibility was also 100-210 .mu. m.

  • PDF

지능형 칼라 맞춤 및 조제 시스템 설계 (Design of Intelligent Type for Color Matching and Measuring Systems)

  • 류상문;한일석;박병준;안태천
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.156-156
    • /
    • 2000
  • In this paper, a new method for colour measuring is presented using fuzzy modeling technique. The fuzzy and polynomial inferences are used for obtaining RGB characteristic curve. The eight RGB real data from expert dye-stuff manufacturer, are simulated. The results show that the proposed method will is more excellent than other methods, in the colour measuring process of textile field.

  • PDF

퍼지 모델링 기법을 이용한 새로운 칼라 메저링 방법 (A New Method for Colour Measuring Using Fuzzy Modeling Technique)

  • 류상문;한일석;박병준;안태천
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2000년도 춘계학술대회 학술발표 논문집
    • /
    • pp.183-186
    • /
    • 2000
  • In this paper, a new method for colour measuring is presented using fuzzy modeling technique. The fuzzy and polynomial inferences are used for obtaining RGB characteristic curve. The eight RGB real data from expert dye-stuff manufacturer, are simulated. The results show that the proposed method will is more excellent than other methods, In the colour measuring process of textile field.

  • PDF

XLPE 케이블의 PD 검출 필터 시험 (Filter Test for Detecting Partial Discharge in XLPE Cable)

  • 조재철;최용성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.218-221
    • /
    • 2008
  • Due to a variable noises in the field underground lines, clear technology of noises is very important in the diagnosis technology of partial discharge. Therefore we progressed filter test to improve the measuring test of partial discharge in a field. We applied to field test after making W-LC filter for partial discharge measurement, and then designed experimental environment such as under- ground distribution lines of field. Measuring sensor for test was UHF sensor. And we analysed those using the Lemke Probe and oscilloscope (TDS-3054, Tektro- nix). Finally, we obtained excellent data of noise decrement in the joint box of 22.9[kV] distribution lines from above experiment.

  • PDF

XLPE 케이블의 PD 검출 필터 시험 (Filter Test for Detecting Partial Discharge in XLPE Cable)

  • 김대열;윤주호;최용성;박대희;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.72-74
    • /
    • 2007
  • Due to a variable noises in the field underground lines, clear technology of noises is very important in the diagnosis technology of partial discharge. Therefore we progressed filter test to improve the measuring test of partial discharge in a field. We applied to field test after making W-LC filter for partial discharge measurement, and then designed experimental environment such as underground distribution lines of field. Measuring sensor for test was UHF sensor. And we analysed those using the Lemke Probe and oscilloscope (TDS-3054, Tektronix). Finally, we obtained excellent data of noise decrement in the joint box of 22.9[kV] distribution lines from above experiment.

  • PDF

22.9kV XLPE 케이블 PD 검출용 필터 시험 (Filter Test for Detecting Partial Discharge in 22.9kV XLPE Cable)

  • 이용성;김정윤;김석종;이경용;최용성;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2277-2279
    • /
    • 2005
  • Due to a variable noises in the field underground lines, clear technology of noises is very important in the diagnosis technology of partial discharge. Therefore we progressed filter test to improve the measuring test of partial discharge in a field. We applied to field test after making W-LC filter for partial discharge measurement, and then designed experimental environment such as under-ground distribution lines of field. Measuring sensor for test was UHF sensor. And we analysed those using the Lemke Probe and oscilloscope (TDS-3054, Tektronix). Finally, we obtained excellent data of noise decrement in the joint box of 22.9[kV] distribution lines from above experiment.

  • PDF

폐광지역 지반공사시 지반침하 관리를 위한 기준 (Standards for Ground Settlement Management when Reinforcing Ground in the Abandoned Mine)

  • 양인재;이승아;백동호
    • 터널과지하공간
    • /
    • 제27권5호
    • /
    • pp.295-302
    • /
    • 2017
  • 본 연구에서는 폐광지역 지반침하 관리시 토목분야(도로, 철도 등)의 계측관리기준을 그대로 준용하고 있는 현행 계측수행 상의 문제점을 개선하기 위해 광산분야에서 적용할 수 있는 새로운 정량적 계측관리기준을 제시하였다. 광해관리공단의 협조를 얻어 폐광지역에서 수행된 지반침하 관련 자료들을 수집하였고, 이 중 현장에서 실측된 수동계측자료들을 토대로 새로운 계측관리기준치 설정에 대한 여러 기법들에 대해 연구하였다. 그 결과, 계측치들의 평균값, 3사분위수, 95% 신뢰도, 최대값 등의 통계량을 통해 계측항목별 계측관리기준치를 설정, 제안하였다.

Separation of Isochromatics and Isoclinics from Photoelastic Fringes in a Circular Disk by Phase Measuring Technique

  • Baek, Tae-Hyun;Kim, Myung-Soo;Yoshihau Morimoto;Motoharu Fujigaki
    • Journal of Mechanical Science and Technology
    • /
    • 제16권2호
    • /
    • pp.175-181
    • /
    • 2002
  • A new polariscope system involving two rotating optical elements and a digital camera for whole field fringe analysis allows automated data to be acquired quickly and efficiently. The developed phase measuring technique that uses eight images through a circular polariscope is presented for the digital measurement of isochromatics and isoclinics, respectively, from photoelastic fringes in a circular disk under diametric compression. Isochromatics can directly be obtained using wrapped isoclinic phases calculated by the arc tangent operator which is the four-quadrant operator from -$\pi$ to $\pi$. It is not required to unwrap isoclinic phases for the calculations of isochromatics. Unwrapped isoclinics are directly determined from isochromatic parameters. Distributions of digitally determined isoclinics are in close agreement to manual measurements. The errors which would appear in unwrapping process of isoclinics can be avoided in the determination of isochromatics.