• Title/Summary/Keyword: field instrument

Search Result 570, Processing Time 0.042 seconds

Preparation of Titanium Microfiltration Membrane by Field-flow Fractionation Deposition

  • Wang, QiangBing;Tang, HuiPing;Zhang, QianCheng;Qiu, QunFeng;Wang, JianYong
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.312-313
    • /
    • 2006
  • The primary aim pursued by the preparation of separation membrane is the preparation of the membrane thin as well as with no defect. The field-flow fractionation deposition is a new molding technology which can overcome the traditional disadvantages such as multi-preparation to the preparation of great area of separation membrane with no defect. Therefor the mainly ingredients which influence the appearance and performance of titanium membrane layer are investigated by scanning electricity mirror (SEM) as well as porous material testing instrument: powder performance prepared and confected; selection of supporting body; sintering system such as temperature and time. It is shown that the membrane thickness can be controlled at $50{\mu}m$ or so; the filtration precision mainly rests with powder performance and selection of supporting body and little sintering system

  • PDF

A Study on the Fabrication of Magnetorheometer (마그네토리오메타 제작에 관한 연구)

  • 김영민;신영재;이응숙;김동우;이동주
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.496-500
    • /
    • 2004
  • A new, commercially available polishing process called magnetorheological finishing is used to polish and figure precision optics. To understand and model this process correctly it is important to determine the mechanical properties of the fluid under the influence of the magnetic field. Magnetorheological (MR) fluids are commonly modeled as Bingham fluids, so one of the essential properties to measure is the yield stress. Since MR fluids are inherently anisotropic, the yield stress will depend on the mutual orientation of the magnetic field and the direction of deformation. The relative orientation of the field and deformation in polishing does not coincide with common rheological setups, so a new rheometer has been designed and tested. This new magnetorheometer design has been shown to give correct stresses during calibration experiments using Newtonian fluids with a known viscosity. The measured stress has also been shown to have a magnitude consistent with published finite element approximations for magnetic fluids. The design of the instrument was complicated because of the requirements imposed upon the magnetic field, and the difficulty in satisfying the no slip boundary condition. Our results show the importance of having a homogeneous field in the test region during measurements. The solutions to these problems and discussion of the measurements on nonmagnetic and magnetic fluids are given.

  • PDF

Variation Analysis of Elevation within a Rice Paddy Field (수도작 포장의 고저차 분석)

  • Sung J.H.;Jang S.W.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.3 s.116
    • /
    • pp.188-193
    • /
    • 2006
  • Elevation differences within a paddy field relate strongly to plant health, crop homogeneity, and pest control. For precision agriculture (PA), the elevation within a field should be precisely controlled. We analyzed variation in elevation within a rice paddy field over one crop cycle. The study took place in a rectangular plot (100 m x 30 m). Elevations within the a plots was measured by a laser-equipped surveying instrument, that could determine elevations to precisions of I mm. The test field was divided into grids with 30 squares; elevation was measured at the center of each 5 x 10-m grid square. This study measured elevation during nine observation periods from pre-plowing to post-harvest. Descriptive statistics showed the highest elevations after plowing due to soil disturbance. One-way analysis of variance (ANOVA) revealed significant elevation differences before and after plowing and transplanting, although elevations were similar over the period of crop growth. Comparison of pre-plowing and post-harvest data showed differences in elevations, indicating that elevation changes occurred during plowing, rice transplanting, plant growth, and harvesting. In summary, the above statistical analysis indicated that elevation changes occurred due to plowing but not during the plant growth season or due to harvesting.

Analysis of Solar Microwave Burst Spectrum, I. Nonuniform Magnetic Field

  • Lee, Jeongwoo
    • Journal of Astronomy and Space Sciences
    • /
    • v.35 no.4
    • /
    • pp.211-218
    • /
    • 2018
  • Solar microwave bursts carry information about the magnetic field in the emitting region as well as about electrons accelerated during solar flares. While this sensitivity to the coronal magnetic field must be a unique advantage of solar microwave burst observations, it also adds a complexity to spectral analysis targeted to electron diagnostics. This paper introduces a new spectral analysis procedure in which the cross-section and thickness of a microwave source are expressed as power-law functions of the magnetic field so that the degree of magnetic inhomogeneity can systematically be derived. We applied this spectral analysis tool to two contrasting events observed by the Owens Valley Solar Array: the SOL2003-04-04T20:55 flare with a steep microwave spectrum and the SOL2003-10-19T16:50 flare with a broader spectrum. Our analysis shows that the strong flare with the broader microwave spectrum occurred in a region of highly inhomogeneous magnetic field and vice versa. We further demonstrate that such source properties are consistent with the magnetic field observations from the Michelson Doppler Imager instrument onboard the Solar and Heliospheric Observatory (SOHO) spacecraft and the extreme ultraviolet imaging observations from the SOHO extreme ultraviolet imaging telescope. This spectral inversion tool is particularly useful for analyzing microwave flux spectra of strong flares from magnetically complex systems.

Analysis of Magnetic Field Variation for Pulse Wave by Using Finite Element Method (유한 요소법을 이용한 맥진 파형의 자기장 변화 분석)

  • Park, Tae-Young;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.3
    • /
    • pp.90-96
    • /
    • 2014
  • The magnetic field variation by the permanent magnet fluctuation positioned on a "Chwan" of wrist according to the movement of radial artery was generated. The clip-type pulsimeter equipped with a Hall device sensing magnetic field pulse movement analyzed the characteristics of pulse wave as output signals. The magnetic field curve and pulse waveform simulated by the finite element method were compared and analyzed with each other. Also, the variation of magnetic field distribution one permanent magnet investigated by the fabrication of clip-type pulsimeter simulator. This result suggests that the clip-type pulsimeter can be used the reproducible and efficacious oriental diagnostic medical instrument.

Operational Availability Analysis of KOMPSAT TTC System (KOMPSAT 관제시스템의 운용가용도 분석)

  • 장대익;고지환이성팔김대영
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.155-158
    • /
    • 1998
  • The KOMPSAT system incorporates multiple missions designed to provide various applications in the field of Korean peninsula observation covering land, sea and coastal zones. The missions are Korea cartography (1:25,000 scale maps of the Korean peninsula), biological oceanography and science instrument accommodation. The operational availability of KOMPSAT TTC system should be predicted more accurately because its failure has a significant influence on satellite command and tracking and on satellite data collection. In this paper, system availability structure of KOMPSAT TTC system are made and availability of KOMPSAT TTC system is analyzed aspect to the system operation in accordance with logistic condition.

  • PDF

An Improved Musculoskeletal Discomfort Assessment Questionnaire (근골격계 장애 분석을 위한 설문지 조사에 관한 연구)

  • 장성록
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.2
    • /
    • pp.148-154
    • /
    • 1999
  • A self-report musculoskeletal assessment tool was adapted following field use by ergonomic analysis teams and was administrated to 100 employees of ChangWon techno-complex. Results were analyzed to determine of the self-report could adequately predict whether or not an employee reportedly sought medical treatment for a work-related discomfort. It is anticipated this tool can be utilized as an easily administrated, proactive surveillance instrument to assist in early identification of ergonomic concerns and to help prioritize jobs for intervention.

  • PDF

EIC integrated DCS with single console

  • Kawahara, Hiroshi;Hwa, Hong-Tae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10b
    • /
    • pp.928-933
    • /
    • 1988
  • Control technology has been making remarkable progress in electrical control (E), instrumentation & control (I) and computer control (C) field respectively. In order to rationalize system engineering and simplify system configuration and operation work, so called, EIC are now to be integrated into one system. FUJI has developed it's own E, I&C integrated system, to meet above mentioned market requirements of variety. This paper describes basic concept of FUJI's Integrated Man-Machine Interface, hereinafter called SINGLE CONSOLE, from some view points of E, I, C integration technology.

  • PDF

DIFFRACTION ANALYSIS OF LAMOST - TWO SEGMENTED MIRRORS INCLUDED

  • Xu WENLI
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.spc1
    • /
    • pp.399-400
    • /
    • 1996
  • LAMOST is a special reflecting Schmidt telescope. Both the refleting Schmidt plate $M_A$ and the spherical primary mitrror $M_B$ are segmened mirrors. These two cofocus but not co-phase. The diffraction of the optical system is decided by the shape overlapping of $M_A$ and $M_B$. This paper describes the diffraction caculating results with different declination and different field angle. The diffraction influence to the image quality is acceptable in the error buget of optical system. It also proves that the size seletion of the sub-mirror is reasonable.

  • PDF

Problems of Field Instrumentation System in associaion with Seoul Subway Construction (서울지하철 건설공사 계측현황 및 개선방안)

  • 이인근
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03c
    • /
    • pp.78-87
    • /
    • 2000
  • Enormous instruments have been installed to measure movement and stresses during and after the construction of Seoul Subway. However, a number of problems have been noticed and reported, such as planning, calibration, installation, contract procedure etc. Some of them are presented and discussed in this paper in order to call an attention to these problems and provide a baseline for the future improvement.

  • PDF