• Title/Summary/Keyword: field detection

Search Result 2,410, Processing Time 0.038 seconds

Knowledge, Barriers and Attitudes Towards Breast Cancer Mammography Screening in Jordan

  • Abu-Helalah, Munir Ahmad;Alshraideh, Hussam Ahmad;Al-Serhan, Ala-Aldeen Ahmad;Kawaleet, Mariana;Nesheiwat, Adel Issa
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.9
    • /
    • pp.3981-3990
    • /
    • 2015
  • Background: Breast cancer is the most common type of cancer in Jordan. Current efforts are focused on annual campaigns aimed at increasing awareness about breast cancer and encouraging women to conduct mammogram screening. In the absence of regular systematic screening for breast cancer in Jordan, there is a need to evaluate current mammography screening uptake and its predictors, assess women's knowledge and attitudes towards breast cancer and screening mammograms and to identify barriers to this preventive service. Materials and Methods: This cross-sectional study was conducted in six governorates in Jordan through face-to-face interviews on a random sample of women aged 40 to 69 years. Results: A total of 507 participants with mean age of $46.8{\pm}7.8$ years were interviewed. There was low participation rate in early detection of breast cancer practices. Breast self-examination, doctor examination and periodic mammography screening were reported by 34.9%, 16.8% and 8.6% of study participants, respectively. Additionally 3.8% underwent breast cancer screening at least once but not periodically, while 87.6% had never undergone mammography screening. Reported reasons for conducting the screening were: perceived benefit (50%); family history of breast cancer (23.1%); perceived severity (21.2%); and advice from friend or family member (5.8%). City residents have shown higher probability of undergoing mammogram than those who live in towns or villages. Results revealed negative perceptions and limited knowledge of study participants on breast cancer and breast cancer screening. The most commonly reported barriers for women who never underwent screening were: fear of results (63.8%); no support from surrounding environment (59.7); cost of the test (53.4%); and religious belief, i.e. Qadaa Wa Qadar (51.1%). Conclusions: In the absence of regular systematic screening for breast cancer in Jordan, the uptake of this preventive service is very low. It is essential for the country of Jordan to work on applying regular systematic mammography screening for breast cancer. Additionally, there is a need for improvement in the current health promotion programmes targeting breast cancer screening. Other areas that could be targeted in future initiatives in this field include access to screening in rural areas and removal of current barriers.

Development of Signal Control Strategy for Oversaturated Intersections Using Wayside Video Equipment (노변영상장비를 활용한 과포화 신호제어전략 개발)

  • Lee, Hyun;Kim, Won-Ho
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.4
    • /
    • pp.11-21
    • /
    • 2013
  • The conventional real-time signal control strategy for oversaturated situation generally requires a number of detectors at the intersection in order to identify the queue length at each approach. Also, existing strategy for the spillback has limited effect due to the temporal spillback control which only reduce the green split at the approach. In this study, a signal control system utilizing the imagery information from ITS roadside equipment is developed for operation of oversaturated intersections. The strategy calculates the saturation ratio based on the queue length extracted from ITS RSE, and designs the signal control variables according to the saturation ratio. The signal control strategy is divided into two phases: oversaturated and supersaturated. In oversaturated conditions, timing plan for main approach is optimized by the queue length. In oversaturated conditions where spillback might occur, the signal timing is designed in order to avoid the spillback. To increase field adaptability, the strategy is designed to adjust the split length, all-red-time, and clearance time, and keep the major signal control variables intact. The result of the simulation shows that in oversaturated conditions, the improvement is similar to the real-time signal control system. In case of, oversaturated conditions, however, the effect of the strategy is superior to that of a real-time system.

Detection of Limesilicate Cavities by 3-D Electrical Resistivity Survey (3차원 전기비저항탐사에 의한 석회규산염암의 공동탐지)

  • Park, Sam-Gyu;Kim, Chang-Ryol;Son, Jeong-Sul;Kim, Jung-Ho;Yi, Myeong-Jong;Cho, Seong-Jun
    • Economic and Environmental Geology
    • /
    • v.39 no.5 s.180
    • /
    • pp.597-605
    • /
    • 2006
  • In this study, we examined the applicability of 3-D electrical resistivity survey to detect underground cavities within ground subsidence area at the field test site, located at Yongweol-ri, Muan-gun in Korea. Underground cavities are widely present within the limesilicate bedrock overlain by the alluvial deposits in the area of the test site where the ground subsidences have occurred in the past. The limesilicate cavities are mostly filled with groundwater and clays in the test site. Thus, cavities have low electrical resistivity compared to the surrounding host bedrock. The results of the study have shown that the zones of low resistivity correspond to the zones of the cavities identified in the boreholes at the test site, and that the 3-D electrical resistivity survey is very effective to detect underground cavities.

The Influence of Sensory Interference Arising from View-Height Differences on Visual Short-Term Memory Performance (조망 높이의 차이가 초래한 감각적 간섭이 시각단기기억 수행에 미치는 영향)

  • Ka, Yaguem;Hyun, Joo-Seok
    • Science of Emotion and Sensibility
    • /
    • v.23 no.1
    • /
    • pp.17-28
    • /
    • 2020
  • Lowering observers' view-height may increase the amount of occlusion across objects in a visual scene and prevent the accurate identification of the objects in the scene. Based on this possibility, memory stimuli in relation to their expected views from different heights were displayed in this study. Thereafter, visual short-term memory (VSTM) performance for the stimuli was measured. In Experiment 1, the memory stimuli were presented on a grid-background drawn according to linear perspectives, which varied across observers' three different view-heights (high, middle, and low). This allowed the participants to remember both the color and position of each memory stimulus. The results revealed that testing participants' VSTM performance for the stimuli under a different memory load of two set-sizes (3 vs. 6) demonstrated an evident drop of performance in the lowest view-height condition. In Experiment 2, the performance for six stimuli with or without the grid-background was tested. A similar pattern of performance drop in the lowest condition as in Experiment 1 was found. These results indicated that different view-heights of an observer can change the amount of occlusion across objects in the visual field, and the sensory interference driven by the occlusion may further influence VSTM performance for those objects.

Detection of Rapid Atrial Arrhythmias in SQUID Magnetocardiography (스퀴드 심자도 장치를 이용한 심방성 부정맥의 측정)

  • Kim Kiwoong;Kwon Hyukchan;Kim Ki-Dam;Lee Yong-Ho;Kim Jin-Mok;Kim In-Seon;Lim Hyun-Kyoon;Park Yong-Ki;Kim Doo-Sang;Lim Seung-Pyung
    • Progress in Superconductivity
    • /
    • v.7 no.1
    • /
    • pp.28-35
    • /
    • 2005
  • We propose a method to measure atrial arrhythmias (AA) such as atrial fibrillation (Afb) and atrial flutter (Afl) with a SQUID magnetocardiograph (MCG) system. To detect AA is one of challenging topics in MCG. As the AA generally have irregular rhythm and atrio-ventricular conduction, the MCG signal cannot be improved by QRS averaging; therefore a SQUID MCG system having a high SNR is required to measure informative atrial excitation with a single scan. In the case of Afb, diminished f waves are much smaller than normal P waves because the sources are usually located on the posterior wall of the heart. In this study, we utilize an MCG system measuring tangential field components, which is known to be more sensitive to a deeper current source. The average noise spectral density of the whole system in a magnetic shielded room was $10\;fT/{\surd}Hz(a)\;1\;Hz\;and\;5\;fT/{\surd}Hz\;(a)\;100\;Hz$. We measured the MCG signals of patients with chronic Afb and Afl. Before the AA measurement, the comparison between the measurements in supine and prone positions for P waves has been conducted and the experiment gave a result that the supine position is more suitable to measure the atrial excitation. Therefore, the AA was measured in subject's supine position. Clinical potential of AA measurement in MCG is to find an aspect of a reentry circuit and to localize the abnormal stimulation noninvasively. To give useful information about the abnormal excitation, we have developed a method, separative synthetic aperture magnetometry (sSAM). The basic idea of sSAM is to visualize current source distribution corresponding to the atrial excitation, which are separated from the ventricular excitation and the Gaussian sensor noises. By using sSAM, we localized the source of an Afl successfully.

  • PDF

The Effect of Apple Tree Growth and Apple Yield from the Misuse of Non Selective Herbicide, Glufosinate-ammonium (비선택성 제초제 Glufosinate-ammonium 오용이 사과나무의 품종별 생육반응 및 수확에 미치는 영향)

  • Lee, In-Yong;Park, Yong-Seog;Kim, Sung-Min;Kang, Cheol-Ah;Chun, Byeong-Chul;Park, Jae-Eup
    • Korean Journal of Weed Science
    • /
    • v.30 no.4
    • /
    • pp.454-459
    • /
    • 2010
  • This study was conducted to investigate the phytotoxic reaction and the impact on the growth of apple fruit included the yield amount by misuse of non-selective herbicide, glufosinate-ammonium in apple field and for the study, 4 cultivars of apple were tested. The results showed that the highest phytotoxic degree was observed on Sansa-cultivar and then the degree was diminished on Tsugaru, Hongro and Fuji in order in the application year. In one year after application, the highest phytotoxic degree was showed on Fuji and then diminished on Tsugaru, Hongro and Sansa in order. However, in one year after application, the phytotoxic symptom was negligible in comparison with the degree in the year of application and the flowering and fruiting were reduced 30% only in Fuji, but in the other cultivars, the phytotoxic symptoms were not observed. Meanwhile, the residue of glufosinate-ammonium was below the detection limit as 0.04ppm in all tested cultivars and in 2years after application, the phytotoxic symptom was not observed in all cultivars of the apple.

Tissue Distribution after dipping administration of Oxytetracycline and Tetracycline in Olive flounder (Paralichthys olivaceus), Rockfish (Sebastes schlegeli), and Red sea bream (Pagrus major) (Oxytetracycline과 Tetracycline의 약욕에 따른 양식어류 (넙치, 조피볼락, 참돔)의 조직내 잔류량의 변화)

  • Lee, Hu-Jang;Kim, Suk;Ha, Ji-Young;Kang, Seok-Jung;Jung, Won-Cheol;Chung, Hee-Sik;Heo, Sung-Hyek;Shin, Yong-Woon;Kim, Kyoung-Won;Kim, Dae-Geun
    • Journal of fish pathology
    • /
    • v.19 no.2
    • /
    • pp.155-164
    • /
    • 2006
  • Tissue distribution and residue depletion of oxytetracycline (OTC) and tetracycline (TC) following dipping administration were evaluated in olive flounder (Paralichthys olivaceus), rockfish (Sebastes schlegeli), and red sea bream (Pagrus major) under field conditions. Fishes were held in floating cages placed in sea water and fed a commercial diet for 15 days to acclimate to a new surrounding. Fishes were dipped in OTC 50 g/ton water for 30min and TC 18 g/ton water for 5 hours. Blood and muscle were sampled from fishes on 0th, 1th, 2th, 3th, and 5th day after administration. After solid-phase extraction, OTC and TC analyses were carried out by HPLC. The recovery rate of OTC in serum and muscle samples was 71-77% and 78-84%, respectively. Also, the recovery rate of TC in serum and muscle samples was 70-79% and 73-78%, respectively. The results of recovery rate were similar to previous studies reported. At the termination of dipping administration of OTC and TC, residue concentration in muscle samples of rockfish was significantly higher than those of olive flounder and red sea bream. At day 5, residue concentrations of all samples were believed to decrease to lower than 0.05 mg/kg, the detection limit. The present study showed that residue concentrations of OTC and TC decreased to below 0.05 mg/kg after treatment 5th day, faster than the established withdrawal period. The tissue reside depletion time of dipping administration of OTC and TC seems to be shorter than those of oral or parenteral administration.

The Significance of $Gallium^{67}$ Scan in Miliary Tuberculosis (속립성 결핵에서 $Ga^{67}$ 주사의 의의)

  • Kim, Hyung-In;Jin, Choon-Jo;Yong, Suk-Joong;Shin, Kye-Chul
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.5
    • /
    • pp.558-564
    • /
    • 1993
  • Background: Gallium scans was used clinically for detection of inflammatory lesion, granulomatous process and neoplasm and inflammatory activity in interstitial disease. So we had perfomed $Ga^{67}$ scan to see the finding of $Ga^{67}$ scan in miliary tuberculosis and to correlate $Ga^{67}$ uptake with that of the chest PA and the clinical severity. Method: We examined 10 patients who were confirmed as having miliary tuberculosis, with $Ga^{67}$ scan, chest PA and arterial blood gas analysis. Results: 1) Diffuse, positive gallium uptake was seen in all cases of miliary tuberculosis. 2) In most of cases, gallium uptake was noted only at the lung field in spite of hematogenous spread of tuberculous foci. 3) The strong correlation between chest PA and $Ga^{67}$ scan finding was seen. 4) The intimate correlation between arterial hypoxemia and $Ga^{67}$ scan finding was also noted. Conclusion: Gallium scan showed diffuse pulmonary uptake in all cases of miliary tuberculosis and it may provid a useful information to assess the disease severity in miliary tuberculosis.

  • PDF

Evaluation of Half Cell Potential Measurement in Cracked Concrete Exposed to Salt Spraying Test (염해에 노출된 균열부 콘크리트의 반전위 평가)

  • Kim, Ki-Bum;Park, Ki-Tae;Kwon, Seung-Jun
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.6
    • /
    • pp.621-630
    • /
    • 2013
  • Several techniques for steel corrosion detection are proposed and HCP (half cell potential) technique is widely adopted for field investigation. If concrete has cracks on surface, steel corrosion is rapidly accelerated due to additional intrusion of chloride and carbon dioxide ions. This study is for an evaluation of HCP in cracked concrete exposed chloride attack. For this work, RC (reinforced concrete) beams are prepared considering 3 w/c ratios (0.35, 0.55, and 0.70) and several cover depths (10~60 mm) and various crack widths of 0.0~1.0 mm are induced. For 35 days, SST (salt spraying test) is performed for corrosion acceleration, and HCP and corrosion length of rebar are evaluated. With increasing crack width, w/c ratios, and decreasing cover depth, HCP measurements increase. HCP evaluation technique is proposed considering the effects of w/c ratios, crack width, and cover depth. Furthermore anti-corrosive cover depths are obtained through Life365 program and the results are compared with those from this study. The results shows relatively big difference in cracked concrete, however provide similar anti-corrosive conditions in sound concrete.

Automatic On-Chip Glitch-Free Backup Clock Changing Method for MCU Clock Failure Protection in Unsafe I/O Pin Noisy Environment (안전하지 않은 I/O핀 노이즈 환경에서 MCU 클럭 보호를 위한 자동 온칩 글리치 프리 백업 클럭 변환 기법)

  • An, Joonghyun;Youn, Jiae;Cho, Jeonghun;Park, Daejin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.12
    • /
    • pp.99-108
    • /
    • 2015
  • The embedded microcontroller which is operated by the logic gates synchronized on the clock pulse, is gradually used as main controller of mission-critical systems. Severe electrical situations such as high voltage/frequency surge may cause malfunctioning of the clock source. The tolerant system operation is required against the various external electric noise and means the robust design technique is becoming more important issue in system clock failure problems. In this paper, we propose on-chip backup clock change architecture for the automatic clock failure detection. For the this, we adopt the edge detector, noise canceller logic and glitch-free clock changer circuit. The implemented edge detector unit detects the abnormal low-frequency of the clock source and the delay chain circuit of the clock pulse by the noise canceller can cancel out the glitch clock. The externally invalid clock source by detecting the emergency status will be switched to back-up clock source by glitch-free clock changer circuit. The proposed circuits are evaluated by Verilog simulation and the fabricated IC is validated by using test equipment electrical field radiation noise