• Title/Summary/Keyword: fibroblast L-929

Search Result 46, Processing Time 0.018 seconds

A Study on Oxidation Behavior and Cytotoxicity Test of Ti-10Ta-10Nb Alloy (생체용 타이타늄 합금의 산화거동 및 세포독성에 관한 연구)

  • Cho, Hong-Kyu;Lee, Doh-Jae;Lee, Kwang-Min;Lee, Kyung-Ku
    • Journal of Technologic Dentistry
    • /
    • v.26 no.1
    • /
    • pp.97-104
    • /
    • 2004
  • A new Ti-10Ta-10Nb alloy has designed and examined some possibility of forming more passive oxide film by oxidation treatment which is closely related to corrosion resistance and biocompatibility. Ti-6Al-4V and Ti-10Ta-10Nb alloys were prepared by consumable vacuum arc melting and homogenized at 1050$^{\circ}C$ for 24hours. Alloy specimens were oxidized at the temperature range of 400 to 750$^{\circ}C$ for 30minutes, and the oxide films on Ti alloys were analysed by optical microscope, SEM, XPS and TGA. Cytotoxicity test was performed in MTT assay treated L929 fibroblast cell culture by indirect method. It is found out that the oxide film on Ti-10Ta-10Nb alloy is denser and thinner compared to Ti-6Al-4V alloy. The weight gain during the oxidation was increased rapidly at the temperature above 650$^{\circ}C$ for Ti-6Al-4V alloy and above 700$^{\circ}C$ for Ti-10Ta-10Nb alloy respectively. It was analysed that the passive film of the Ti alloys consisted of TiO2 through X-ray photoelectron spectroscopy (XPS) analysis. It is found out by cytotoxicity test that moderate oxidation treatment lowers cell toxicity, and Ti-10Ta-10Nb alloy showed better result compared to Ti-6Al-4V alloy.

  • PDF

Spherical and cylindrical microencapsulation of living cells using microfluidic devices

  • Hong, Joung-Sook;Shin, Su-Jung;Lee, Sang-Hoon;Wong, Edeline;Cooper-White, Justin
    • Korea-Australia Rheology Journal
    • /
    • v.19 no.3
    • /
    • pp.157-164
    • /
    • 2007
  • Microencapsulation of cells within microfluidic devices enables explicit control of the membrane thickness or cell density, resulting in improved viability of the transplanted cells within an aggressive immune system. In this study, living cells (3T3 and L929 fibroblast cells) are encapsulated within a semi-permeable membrane (calcium crosslinked alginate gel) in two different device designs, a flow focusing and a core-annular flow focusing geometry. These two device designs produce a bead and a long microfibre, respectively. For the alginate bead, an alginate aqueous solution incorporating cells flows through a flow focusing channel and an alginate droplet is formed from the balance of interfacial forces and viscous drag forces resulting from the continuous (oil) phase flowing past the alginate solution. It immediately reacts with an adjacent $CaCl_2$ drop that is extruded into the main flow channel by another flow focusing channel downstream of the site of alginate drop creation. Depending on the flow conditions, monodisperse microbeads of sizes ranging from $50-200\;{\mu}m$ can be produced. In the case of the microfibre, the alginate solution with cells is extruded into a continuous phase of $CaCl_2$ solution. The diameter of alginate fibres produced via this technique can be tightly controlled by changing both flow rates. Cell viability in both forms of alginate encapsulant was confirmed by a LIVE/DEAD cell assay for periods of up to 24 hours post encapsulation.

Oxidative Stress in the Cell and Antioxidant Activity of Kalopanax Pictus Extracts (음나무 추출물의 세포 내 산화 스트레스와 항산화 활성)

  • Kim, Sea-Hyun;Park, Youngki;Jang, Yong-Seok;Han, Jingyu;Chung, Hun-Gwan
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.126-134
    • /
    • 2007
  • This study reviewed the application of an extract from Kalopanax pictus stem bark and root bark as natural antioxidants. To investigate the effect on cell toxic level against transformed mouse fibroblast L929 in formula added with various extracts from Kalopanax pictus stem bark and root bark, this experiment was carried out by in vitro cytotoxicity method. Using DCFA-DA method, oxidative stress in cell was measured with other antioxidant activity methods including DPPH assay and NBT assay. Active oxygen inhibition rate for root bark insoluble hot water extracts showed the highest with 57.9% for 15 min treatment. In DPPH and NBT test, antioxidant activities of methanol extract from stem bark and insoluble hot water extract from stem bark were 96% (at 0.1%) and 95% (at 0.5%), respectively.

CYTOTOXICITY OF RESIN-BASED ROOT CANAL SEALER, ADSEAL (레진 계열 근관봉함재 Adseal의 세포독성에 관한 연구)

  • Kim, Hee-Jung;Baek, Seung-Ho;Lee, Woo-Cheol;Park, Han-Soo;Bae, Kwang-Shik
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.6
    • /
    • pp.498-503
    • /
    • 2004
  • The properties of ideal root canal sealers include the ability of sealing the total root canal system and no toxic effects to periradicular tissues. Cytotoxicity test using cell culture is a common screening method for evaluation of the biocompatibility of root canal sealers. The purpose of this study was to investigate the cytotoxic effect of newly developed resin-based sealer (Adseal 1, 2, and 3) comparing with those commercial resin-based sealers (AH26 and AH Plus), ZOE-based sealers (Tubliseal EWT, Pulp Canal Sealer EWT) and calcium hydroxide based sealer (Sealapex), An indirect contact test of cytotoxicity by agar diffusion was performed according to the international standard ISO 10993-5. L929 fibroblast cells were incubated at $37^{\circ}C$ in humidified 5% $CO_2-containing$ air atmosphere. The freshly mixed test materials were inserted into glass rings of internal diameter 5 mm and height 5 mm placed on the agar. After the 24 hrs incubation period, the decolorization zones around the test materials were assessed using an inverted microscope with a calibrated screen. A Decolorization Index was determined for each specimen. Adseal 1. 2, and 3 did not exert any cytotoxic effects, whereas AH26, AH Plus, Tubliseal EWT, Pulp Canal Sealer EWT, and Sealapex produced mild cytotoxicity.

Evaluation of effect of galvanic corrosion between nickel-chromium metal and titanium on ion release and cell toxicity

  • Lee, Jung-Jin;Song, Kwang-Yeob;Ahn, Seung-Geun;Choi, Jung-Yun;Seo, Jae-Min;Park, Ju-Mi
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.2
    • /
    • pp.172-177
    • /
    • 2015
  • PURPOSE. The purpose of this study was to evaluate cell toxicity due to ion release caused by galvanic corrosion as a result of contact between base metal and titanium. MATERIALS AND METHODS. It was hypothesized that Nickel (Ni)-Chromium (Cr) alloys with different compositions possess different corrosion resistances when contacted with titanium abutment, and therefore in this study, specimens ($10{\times}10{\times}1.5mm$) were fabricated using commercial pure titanium and 3 different types of Ni-Cr alloys (T3, Tilite, Bella bond plus) commonly used for metal ceramic restorations. The specimens were divided into 6 groups according to the composition of Ni-Cr alloy and contact with titanium. The experimental groups were in direct contact with titanium and the control groups were not. After the samples were immersed in the culture medium - Dulbecco's modified Eagle's medium[DMEM] for 48 hours, the released metal ions were detected using inductively coupled plasma mass spectrometer (ICP-MS) and analyzed by the Kruskal-Wallis and Mann-Whitney test (P<.05). Mouse L-929 fibroblast cells were used for cell toxicity evaluation. The cell toxicity of specimens was measured by the 3-{4,5-dimethylthiazol-2yl}-2,5-diphenyltetrazolium bromide (MTT) test. Results of MTT assay were statistically analyzed by the two-way ANOVA test (P<.05). Post-hoc multiple comparisons were conducted using Tukey's tests. RESULTS. The amount of metal ions released by galvanic corrosion due to contact between the base metal alloy and titanium was increased in all of the specimens. In the cytotoxicity test, the two-way ANOVA showed a significant effect of the alloy type and galvanic corrosion for cytotoxicity (P<.001). The relative cell growth rate (RGR) was decreased further on the groups in contact with titanium (P<.05). CONCLUSION. The release of metal ions was increased by galvanic corrosion due to contact between base metal and titanium, and it can cause adverse effects on the tissue around the implant by inducing cytotoxicity.

THE EVALUATION OF CYTOTOXICITY AND BIOCOMPATIBILITY OF TI-TA-NB-BASE ALLOY (Ti-Ta-Nb계 합금의 세포독성과 생체적합성의 평가)

  • Cui De-Zhe;Vang Mong-Sook;Yoon Taek-Rin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.2
    • /
    • pp.250-263
    • /
    • 2006
  • Statement of problem: Ti-alloy has been used widely since it was produced in the United States in 1947 because it has high biocompatibility and anticorrosive characteristics. Purpose: The pure titanium, however, was used limitedly due to insufficient mechanical charateristics and difficult manufacturing process. Our previous study was focused on the development of a new titanium alloy. In the previous study we found that the Ti-Ta-Nb alloy had better mechanical characteristics and similar anticorrosive characteristics to Ti-6Al-4V Material and methods: In this study, the cytotoxicity of the Ti-Ta-Nb alloy was evaluated by MTT assay using MSCs(Mesenchaimal stem cells) and L929 cells(fibroblast cell line). The biocompatibility of the Ti-Ta-Nb alloy was performed by inserting the alloy into the femur of the rabbits and observing the radiological and histological changes surrounding the alloy implant. Results: 1. In the cytotoxicity test using MSCs, the 60% survival rate was observed in pure titanium, 84% in Ti-6Al-4V alloy and 95% in Ti-10Ta-10Nb alloy. 2. In the animal study, the serial follow-up of the radiographs showed no separation or migration revealing gradual bone ingrowth surrounding the implants. Similar radiographic results were obtained among three implant groups pure titanium, Ti-6Al-4V alloy and Ti-10Ta-10Nb alloy. 3. In the histologic examination of the bone block containing the implants. the bone ingrowth was prominent around the implants with the lapse of time. There was no signs of any tissue rejection, degeneration, or inflammation. Active bone ingrowth was observed around the implants. In the comparison of the three groups, the rate of bone ingrowth was better in the Ti-10Ta-10Nb alloy group than those in pure titanium group or Ti-6Al-4V alloy group. In conclusion, Ti-10Ta-10Nb alloy revealed better biocompatibility in survival rate of the cells and bone ingrowth around the implants. Therefore we believe a newly developed Ti-10Ta-10Nb alloy can replace currently used Ti-6Al-4V alloy to increase biocompatibility and to decrease side effects. Conclusion: In conclusion, Ti-10Ta-10Nb alloy revealed better biocompatibility in survival rate of the cells and bone ingrowth around the implants. Therefore we believe a newly developed Ti-10Ta-10Nb alloy can replace currently used Ti-6Al-4V alloy to increase biocompatibility and to decrease side effects.