• Title/Summary/Keyword: female images

Search Result 629, Processing Time 0.036 seconds

Detection of Osteomyelitis Using a Tc-99m Labeled Antigranulocyte Antibody Immunoscintigraphy (Tc-99m 표지 항과립구항체 면역신티그라피를 이용한 골수염의 진단)

  • Kang, Won-Jun;Chung, June-Key;Yeo, Jeong-Seok;Hong, Mee-Kyoung;Jeong, Jae-Min;Lee, Dong-Soo;Lee, Sang-Hoon;Choi, In-Ho;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.344-353
    • /
    • 1998
  • Purpose: The purpose of this study was to evaluate the diagnostic accuracy of Tc-99m labeled antigranulocyte antibody immunoscintigrapy in the diagnosis of osteomyelitis and compare with the results of triphasic bone scan. Materials and Methods: The study population was 39 patients (22 male, 17 female) who had uncertain diagnoses of osteomyelitis. Fifteen patients had history of orthopedic surgery, and 5 had previous fracture. One milligram of monoclonal antibody against NCA-95 was labeled with 370 MBq of Tc-99m, injected intravenously, and 4 hour images were obtained. Triphasic bone scan images were obtained in 30 patients. The final diagnosis was confirmed by bacteriologic culture, biopsy or long term clinical follow up. Results: Twenty one patients were confirmed to have osteomyelitis (1 acute, 20 chronic). Eighteen patients were without osteomyelitis. Antigranulocyte antibody immunoscintigraphy had a sensitivity of 71% (15/21), and a specificity of 89% (16/18), while the sensitivity and specificity of triphasic bone scan was 93% (13/14) and 38% (6/16), respectively. Antigranulocyte antibody scan showed higher specificity of 100% (11/11) in comparison with 33% (3/9) of triphasic bone scan in patients with history of orthopedic surgery or fracture. Conclusion: Antigranulocyte antibody immunoscintigraphy is more specific than that of triphasic bone scan and may be helpful in patients with history of surgery or fracture. However, sensitivity is lower than triphasic bone scan in the detection of chronic osteomyelitis.

  • PDF

Comparison of Ga-67, Tl-201 and Tc-99m MIBI Imaging in Lymphoma Patients (림프종 환자에서의 갈륨, Tl-201 그리고 Tc-99m MIBI 섭취의 비교)

  • Chun, Kyung-Ah;Cho, Ihn-Ho;Won, Kyu-Chang;Lee, Kyung-Hee;Lee, Hyung-Woo;Hyun, Myung-Soo;Lee, Jae-Tae;Lee, Kyu-Bo
    • Journal of Yeungnam Medical Science
    • /
    • v.19 no.2
    • /
    • pp.107-115
    • /
    • 2002
  • Purpose: Ga-67 scintigraphy has been used for the evaluation of tumors, especially lymphoma. Recently, Tl-201 and Tc-99m MIBI were also used to tumor imaging. Tl-201 and Tc-99m MIBI had better physiologic characteristics than Ga-67, so we studied 32 biopsy proven lymphoma patients (male 24, female 8, mean age 46 years) with Ga-67, Tl-201 or Tc-99m MIBI and compared the scan findings. Materials and Methods: Twenty-three of 32 patients were injected 74-111 MBq (2-3 mCi) of Tl-201, before chemotherapy and imaged with dual-headed SPECT (Prism 2000, Picker, USA) at 30 minutes after injection. Delayed images were obtained after 3 hr in 8 patients. Twenty seven of 32 patients were injected 740 MBq (20 mCi) of Tc-99m MIBI and imaged at 30 minutes after injection. 111-185 MBq (3-5 mCi) of Ga-67 was injected in 12 patients and imaged at 48 and 72 hours after injection. Twenty eight patients were diagnosed as non-Hodgkin's lymphoma and others were Hodgkin's lymphoma. Results: Twenty patients were positive on Tl-201 scan and 3 patients showed negative findings. One of these 3 patients, Tc-99m MIBI and Ga-67 scan were positive. Twenty two patients were positive on Tc-99m MIBI scan and 5 patients showed negative findings. One of these 5 patients, Tl-201 was positive and 2 were positive on Ga-67 scan. Ten of 12 patients showed positive findings on Ga-67 scan. The sensitivity of these agents were 83.3%, 87.0% and 81.5% for Ga-67, Tl-201 and Tc-99m MIBI, respectively. The sensitivity was highest in Tl-201 scan, but there were no significant differences among three tests. In this study, there was no significant difference of uptake ratios between early and delayed images of Tl-201. Conclusion: Scintigraphy with Tl-201 and Tc-99m MIBI in lymphoma patients have similar sensitivity with Ga-67.

  • PDF

Evaluation Criteria and Preferred Image of Jeans Products based on Benefit Segmentation (진 제품 구매자의 추구혜택에 따른 평가기준 및 선호 이미지)

  • Park, Na-Ri;Park, Jae-Ok
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.6 s.165
    • /
    • pp.974-984
    • /
    • 2007
  • The purpose of this study was to find differences in evaluation criteria and to find differences in preferred images based on benefits segmented groups of jeans products consumers. Male and female Korean university students participated in the study. Quota sampling method was used to collect the data based on gender and a residential area of the respondents. Data from 492 questionnaires were used in the analysis. Factor analysis, Cronbach's alpha coefficient, cluster analysis, one-way ANOVA, and post-hoc test were conducted. As a result, respondents who seek multi-benefits considered aesthetic criteria(e.g., color, style, design, fit) and quality performance criteria(e.g., durability, ease of care, contractibility, flexibility) more importantly when evaluating and purchasing jeans products. Respondents who seek brand name considered extrinsic criteria(e.g., brand reputation, status symbol, country of origin, fashionability) more importantly than respondents who seek economic efciency. Respondents who seek multi-benefits such as attractiveness, fashion, individuality, and utility tend to prefer all the images: individual image, active image, sexual image, sophisticated image, and simple image when wearing jeans products. Respondents who seek fashion are likely to prefer individual image, and respondents who seek brand name more prefer both individual image and polished image. Mean while, respondents who seek economical efficiency less prefer sexual image and polished image.

The Study of Dose Distribution according to the Using Linac and Tomotherapy on Total Lymphnode Irradiation (선형가속기와 토모치료기를 이용한 전림프계의 방사선 치료시 선량분포에 관한 연구)

  • Kim, Youngjae;Seol, Gwanguk
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.4
    • /
    • pp.285-291
    • /
    • 2013
  • In this study, compare and analyze the dose distribution and availability of radiation therapy when using a different devices to TNI(Total Lymphnodal Irradiation). Test subjects(patients) are 15 people(Male 7, Female 8). Acquire CT Simulation images of the 15 people using Somatom Sansation Open 16 channel and then acquired images was transferred to each treatment planning system Pinnacle Ver 8.0 and Tomotherapy Planning System and separate the tumor tissue and normal tissues(whole lung, spinal cord, Rt kidney, Lt kidney). Tumor prescription dose was set to 750 cGy. and then Compare the Dose Compatibility, Normal Tissue's Absorbed Dose, Dose Distribution and DVH. Statistical analysis was performed SPSS Ver. 18.0 by paired sample Assay. The absorbed dose in the tumor tissue was $751.0{\pm}4.7cGy$ in tomotherapy planning, $746.9{\pm}14.1cGy$ in linac. Tomotherapy's absorbed dose in the tumor was more appropriate than linac. and These values are not statistically significant(p>0.05). Tomotherapy plan's absorbed dose in the normal tissues were less than linac's plan. This value was statistically significant(p<0.05) excepted of whole lung. In DVH, appropriated on tumor and normal tissues in tomotherapy and linac but tomotherapy's TER was better than linac. Namely, a result of Absorbed dose in tumor and normal tissue, Dose distribution pattern, DVH, Both radiation therapy devices were appropriated in radiation therapy on TER. The Linac has a short treatment time(about 15-20 min) and open space on treatment time. It cause infant and pediatric patients to receiving uncomfortable treatment. So, In this case, it will be fine that Linac based therapy was restricted use. and if the patient was cooperative, it will be show a better prognosis that Tomotherapy using Radiation Therapy.

Usefulness of Stomach Extension after Drinking Orange Juice in PET/CT Whole Body Scan (PET/CT 전신 영상에서 오렌지 주스(Orange Juice)를 이용한 위장 확장 영상의 유용성)

  • Cho, Seok-Won;Chung, Seok;Oh, Shin-Hyun;Park, Hoon-Hee;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.86-92
    • /
    • 2009
  • Purpose: The PET/CT has a clear distinction on the lesion of the functional image by adding anatomical information. It also could reduce the examination time using CT data as the attenuation-correction. When the stomach was contracted from a fast, it could bring a misinterpretation of the cancer of the lesion with a presence of physiological $^{18}F$-FDG uptake in stomach and it occasionally would bring an additional scan to confirm. To complement this shortcoming, the method that the patients had water before the examination to extend the stomach had been attempted. However, a short excretion time of the stomach did not give sufficiently extended image of the stomach. Then the patients had additional water and had the examination again. Therefore, the noticed fact is that the stomach excretion time depends on calories, protein content, and the level of carbohydrate. In this study, we use an orange juice to evaluate the extension of the stomach and usefulness of it. Materials and Methods: PET/CT scan were obtained on total 150 of patient from February 2008 to October2008, There were 3 groups in this study and each group had 50 patients. First group drank nothing, Second group drank water and third group drank orange juice. The patients (man 25, female 25) not drinking are the age of 30~71 years old (average: 54), the patients (man: 25, female: 25) drinking water (400 cc) are the age of 28~71 years old (average: 54) and the patients (man: 25, female: 25) drinking orange juice (400 cc) are the age of 32~74 years old (average: 56). The patients were fasted in 6-8 hours before the test, the patients were not diabetic. $^{18}F$-FDG 370~555 MBq were injected intravenously. The patients were in stable position for 1 hour, than the image was obtained. The patients drank water and other patients drank orange juice before Whole body scan. The image scan started from mid-femur to skull base. The emission scan acquired for three minutes per bed and the images were reconstructed. Stomach extension analysis is measured from vertical and horizontal length. Results: Stomach Extension was described as the vertical length of the Non Drink Group was $1.20{\pm}0.50\;cm$, horizontal length was $1.4{\pm}0.53\;cm$, the vertical length of the Water Drink Group was $1.67{\pm}0.63\;cm$, horizontal length was $1.65{\pm}0.77\;cm$, the vertical length of Orange juice Drink Group was $3.48{\pm}0.77\;cm$, horizontal length was $3.66{\pm}0.77\;cm$ in coronal image. Stomach Extension was described the vertical length of the Non Drink Group was $2.03{\pm}0.62\;cm$, horizontal length was $1.69{\pm}0.68\;cm$, the vertical length of Water Drink Group was $5.34{\pm}1.62\;cm$, horizontal length was $2.45{\pm}0.72\;cm$, the vertical length of Orange juice Drink Group was $7.74{\pm}1.62\;cm$, horizontal length was $3.57{\pm}0.77\;cm$ in transverse image. The Stomach Extension has specific differences (p<0.001). The SUVs shows the Non Drink Group were measured as Liver $2.52{\pm}0.42$, Lung $0.51{\pm}0.14$, the Water Drink Group were measured as Liver $2.47{\pm}0.38$, Lung $0.50{\pm}0.14$, Orange juice Drink Group were measured as Liver $2.47{\pm}0.38$, Lung $0.50{\pm}0.14$. The SUVs did not have specific differences (p>0.759). Conclusions: There was not a large difference of SUV in three groups. When the patients drank Orange juice and water, the range extension of stomach was higher than without drinking nothing and it was possible to acquire fully extended images. Therefore, it will be possible that unnecessary additional stomach scans will be reduced by drinking orange juice before the examination so that the patients' claim from uncomfortable and long period of fast will be minimized.

  • PDF

A Study of Influence of Filgrastim on PET/CT In Diffuse Large B cell Lymphoma (미만성 거대 B 세포 림프종 환자에서 Filgrastim 사용이 PET/CT 영상에 미치는 영향에 대한 고찰)

  • NamKoong, Hyuk;Park, Hoon-Hee;Ban, Yung-Gak;Kang, Sin-Chang;Kim, Sang-Kyoo;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.17-23
    • /
    • 2009
  • Purpose: It has been known that PET/CT is very valuable in follow-up study of diffuse large B cell lymphoma (DLBCL). Generally, in DLBCL, radiotherapy and chemotherapy has been progressed, because the lesion hasn‘t been limited to one site. And, it has lead to the decrease of leukocyte like neutropenia, due to myelosuppression of chemotherapy. So, in that case, administration of Filgrastim (Granulocyte colony-stimulating factor; G-CSF) is universal. However, in short time after administration, PET/CT has limitation to offer accurate images, through the uptake of $^{18}F$-FDG is increased in the region that is activated bone marrow by hematopoietic growth. Therefore, the aim of this study is that PET/CT in a certain period of time after administration of Filgrastim is able to show normal degree of $^{18}F$-FDG uptake. Materials and Methods: 10 patients under follow-up study of diffuse large B cell lymphoma were examined in this study from January, 2007 to January, 2009 (Male: 4 persons; Female: 6 persons; The mean age: 53.8 years old; The mean weight: 57.3 Kg). Using PET/CT (Discovery STe; GE Healthcare, Milwaukee, WI, USA), whole body images were acquired in 1 hour after $^{18}F$-FDG injection. For image analysis, each ROI ($120\;mm^2$) was drawn on $C^6$ (the sixth C-spine), $L_4$ (the forth L-spine), liver, spleen, and lung, then SUV (Standard Uptake Value)s were measured. We compared with each uptake between in 1-day and 5~7 days after administration of Filgrastim at same patient, so confirmed significance about these by SPSS version 12. Results: In case of $C_6$, $L_4$, spleen, every SUV of 1 day later was remarkably higher than that of 5~7 days later, but liver and lung were similar. Also, the images acquired after 5~7 days distinct remarkably and show normal degree of $^{18}F$-FDG uptake, because uptake of bone was almost disappeared. Conclusions: In this study, each SUV was prominent difference as a period of time after Filgrastim’s administration. And Filgrastim makes concentrate uptake of $^{18}F$-FDG in bone, but, after 5~7 days, bone‘s uptake was greatly decreased. Therefore, we are able to infer a certain period of time that shows normal degree of uptake, by numerical value proven. Also, we consider that this study contribute to advanced study about the other agent like Pegfilgrastim, Lenograstim besides Filgrastim, afterwards.

  • PDF

Comparison of One-day and Two-day Protocol of $^{11}C$-Acetate and $^{18}F$-FDG Scan in Hepatoma (간암환자에 있어서 $^{11}C$-Acetate와 $^{18}F$-FDG PET/CT 검사의 당일 검사법과 양일 검사법의 비교)

  • Kang, Sin-Chang;Park, Hoon-Hee;Kim, Jung-Yul;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.3-8
    • /
    • 2010
  • Purpose: $^{11}C$-Acetate PET/CT is useful in detecting lesions that are related to livers in the human body and leads to a sensitivity of 87.3%. On the other hand, $^{18}F$-FDG PET/CT has a sensitivity of 47.3% and it has been reported that if both $^{18}F$-FDG and $^{11}C$-Acetate PET/CT are carried out together, their cumulative sensitivity is around 100%. However, the normal intake of the pancreas and the spleen in $^{11}C$-Acetate PET/CT can influence the $^{18}F$-FDG PET/CT leading to an inaccurate diagnosis. This research was aimed at the verification of the usefulness of how much influence these two radioactive medical supplies can cause on the medical images through comparative analysis between the one-day and two-day protocol. Materials and Methods: This research was carried out based on 46 patients who were diagnosed with liver cancer and have gone through the PET/CT (35 male, 11 female participants, average age: $54{\pm}10.6$ years, age range: 29-69 years). The equipment used for this test was the Biograph TruePoint40 PET/CT (Siemens Medical Systems, USA) and 21 participants who went through the one-day protocol test were first given the $^{11}C$-Acetate PET/CT and the $^{18}F$-FDG PET/CT, the latter exactly after one hour. The other 25 participants who went through the two-day protocol test were given the $^{11}C$-Acetate PET/CT on the first day and the $^{18}F$-FDG PET/CT on the next day. These two groups were then graded comparatively by assigning identical areas of interest of the pancreas and the spleen in the $^{18}F$-FDG images and by measuring the Standard Uptake Value (SUV). SPSS Ver.17 (SPSS Inc., USA) was used for statistical analysis, where statistical significance was found through the unpaired t-test. Results: After analyzing the participants' medical images from each of the two different protocol types, the average${\pm}$standard deviation of the SUV of the pancreas carried out under the two-day protocol were as follows: head $1.62{\pm}0.32$ g/mL, body $1.57{\pm}0.37$ g/mL, tail $1.49{\pm}0.33$ g/mL and the spleen $1.53{\pm}0.28$ g/mL. Whereas, the results for participants carried out under the one-day protocol were as follows: head $1.65{\pm}0.35$ g/mL, body $1.58{\pm}0.27$ g/mL, tail $1.49{\pm}0.28$ g/mL and the spleen $1.66{\pm}0.29$ g/mL. Conclusion: It was found that no statistical significant difference existed between the one-day and two-day protocol SUV in the pancreas and the spleen (p<0.05), and nothing which could be misconceived as false positive were found from the PET/CT medical image analysis. From this research, it was also found that no overestimation of the SUV occurred from the influence of $^{11}C$-Acetate on the $^{18}F$-FDG medical images where those two tests were carried out for one day. This result was supported by the statistical significance of the SUV of measurement. If $^{11}C$-Acetate becomes commercialized in the future, the diagnostic ability of liver diseases can be improved by $^{18}F$-FDG and one-day protocol. It is from this result where tests can be accomplished in one day without the interference phenomenon of the two radioactive medical supplies and furthermore, could reduce the waiting time improving customer satisfaction.

  • PDF

Moderating Effect of Lifestyle on Consumer Behavior of Loungewear with Korean Traditional Fashion Design Elements (소비자대함유한국전통시상설계원소적편복적소비행위지우생활방식적조절작용(消费者对含有韩国传统时尚设计元素的便服的消费行为之于生活方式的调节作用))

  • Ko, Eun-Ju;Lee, Jee-Hyun;Kim, Angella Ji-Young;Burns, Leslie Davis
    • Journal of Global Scholars of Marketing Science
    • /
    • v.20 no.1
    • /
    • pp.15-26
    • /
    • 2010
  • Due to the globalization across various industries and cultural trade among many countries, oriental concepts have been attracting world’s attentions. In fashion industry, one's traditional culture is often developed as fashion theme for designers' creation and became strong strategies to stand out among competitors. Because of the increase of preferences for oriental images, opportunities abound to introduce traditional fashion goods and expand culture based business to global fashion markets. However, global fashion brands that include Korean traditional culture are yet to be developed. In order to develop a global fashion brand with Korean taste, it is very important for native citizen to accept their own culture in domestic apparel market prior to expansion into foreign market. Loungewear is evaluated to be appropriate for adopting Korean traditional details into clothing since this wardrobe category embraces various purposes which will easily lead to natural adaptation and wide spread use. Also, this market is seeing an increased demand for multipurpose wardrobes and fashionable underwear (Park et al. 2009). Despite rapid growth in the loungewear market, specific studies of loungewear is rare; and among research on developing modernized-traditional clothing, fashion items and brands do not always include the loungewear category. Therefore, this study investigated the Korean loungewear market and studied consumer evaluation toward loungewear with Korean traditional fashion design elements. Relationship among antecedents of purchase intention for Korean traditional fashion design elements were analyzed and compared between lifestyle groups for consumer targeting purposes. Product quality, retail service quality, perceived value, and preference on loungewear with Korean traditional design elements were chosen as antecedents of purchase intention and a structural equation model was designed to examine their relationship as well as their influence on purchase intention. Product quality and retail service quality among marketing mixes were employed as factors affecting preference and perceived value of loungewear with Korean traditional fashion design elements. Also effects of preference and perceived value on purchase intention were examined through the same model. A total of 357 self-administered questionnaires were completed by female consumers via web survey system. A questionnaire was developed to measure samples' lifestyle, product and retail service quality as purchasing criteria, perceived value, preference and purchase intention of loungewear with Korean traditional fashion design elements. Also, loungewear purchasing and usage behavior were asked as well in order to examine Korean loungewear market status. Data was analyzed through descriptive analysis, factor analysis, cluster analysis, ANOVA and structural equation model was tested via AMOS 7.0. As for the result of Korean loungewear market status investigation, loungewear was purchased by most of the consumers in our sample. Loungewear is currently recognized as clothes that are worn at home and consumers are showing comparably low involvement toward loungewear. Most of consumers in this study purchase loungewear only two to three times a year and they spend less than US$10. A total of 12 items and four factors of loungewear consumer lifestyle were found: traditional value oriented lifestyle, brand-affected lifestyle, pursuit of leisure lifestyle, and health oriented lifestyle. Drawing on lifestyle factors, loungewear consumers were classified into two groups; Well-being and Conservative. Relationships among constructs of purchasing behavior related to loungewear with Korean traditional fashion design elements were estimated. Preference and perceived value of loungewear were affected by both product quality and retail service quality. This study proved that high qualities in product and retail service develop positive preference toward loungewear. Perceived value and preference of loungewear positively influenced purchase intention. The results indicated that high preference and perceived value of loungewear with Korean traditional fashion design elements strengthen purchase intention and proved importance of developing preference and elevate perceived value in order to make sales. In a model comparison between two lifestyle groups: Well-being and Conservative lifestyle groups, results showed that product quality and retail service quality had positive influences on both preference and perceived value in case of Well-being group. However, for Conservative group, only retail service quality had a positive effect on preference and its influence to purchase intention. Since Well-being group showed more significant influence on purchase intention, loungewear brands with Korean traditional fashion design elements may want to focus on characteristics of Well-being group. However, Conservative group's relationship between preference and purchase intention of loungewear with Korean traditional fashion design elements was stronger, so that loungewear brands with Korean traditional fashion design elements should focus on creating conservative consumers' positive preference toward loungewear. The results offered information on Korean loungewear consumers' lifestyle and provided useful information for fashion brands that are planning to enter Korean loungewear market, particularly targeting female consumers similar to the sample of the present study. This study offers strategic and marketing insight for loungewear brands and also for fashion brands that are planning to create highly value-added fashion brands with Korean traditional fashion design elements. Considering different types of lifestyle groups that are associated with loungewear or traditional fashion goods, brand managers and marketers can use the results of this paper as a reference to positioning, targeting and marketing strategy buildings.

Clinical Significance of MRI Findings During Medical Treatment for Tuberculous Spondylitis (척추염 환자의 약물치료기간 중 추적 검사한 MRI소견 변화의 임상적 중요성)

  • Kim, Dae-Jung;Chung, Tae-Sub;Suh, Sang-Hyun;Kim, Keun-Su;Cho, Yong-Eun;Yoon, Young-Sul;Kim, Sam-Soo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.146-151
    • /
    • 2009
  • Purpose : To evaluate magnetic resonance (MR) imaging features of non-surgically treated tuberculous spondylitis and to evaluate the relationships between these features and clinical outcomes. Materials and Methods : Data from ten patients (male:female=6:4, mean age=45 years) with clinically proven tuberculous spondylitis who were treated nonsurgically over three months were analyzed retrospectively from 2000 to 2007. MRI was performed at least three times for each patient, at baseline, every three or six months, and at the end of treatment. All images were analyzed by two radiologists. Results : The mean follow-up period for the MR examination was 10.1 months (range, 4-17 months). Six patients had clinically complete resolution of tuberculous spondylitis with medication treatment only. Four patients were treated with surgical management alongside medication. All ten patients were divided into two groups by clinical outcome; six patients with complete treatment and four patients with incomplete treatment. In the complete treatment group, follow-up MR findings showed a loss of subligamentous spread of abscesses, decreased size of abscesses, no interval changes in vertebral body heights, and fatty changes in spinal lesions. MR findings in the incomplete treatment group showed bone marrow edema extension to adjacent vertebra, extension of the abscesses, and decreased height of the vertebral bodies. Conclusion : During the nonsurgical management of tuberculous spondylitis, MR imaging may play a role in predicting patient response to antituberculous drug treatment.

  • PDF

Usefulness of High-B-value Diffusion - Weighted MR Imaging for the Pre-operative Detection of Rectal Cancers (B-values 변환 자기공명영상: 국소 직장암 수술 전 검출을 위한 적합한 b-value 유용성)

  • Lee, Jae-Seung;Goo, Eun-Hoe;Lee, Sun-Yeob;Park, Cheol-Soo;Choi, Ji-Won
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.683-690
    • /
    • 2009
  • The purpose of this study is to evaluate the usefulness of high-b-values diffusion weighted magnetic resonance imaging for the preoperative detection of focal rectum cancers. 60patients with diffusion weighted imaging were evaluated for the presence of rectal cancers. Forty were male and twenty were female, and their ages ranged from 38 to 71 (mean, 56) years. Used equipment was 1.5Tesla MRI((GE, General Electric Medical System, Excite HD). Examination protocols were used the fast spin echo T2, T1 weighted imaging. All examination protocols were performed by the same location with diffusion weighted imaging for accuracy detection. The b-values used in DWI were 250, 500, 750, 1000. 1500, 2000$(s/mm^2)$. The rectum, bladder to tumor contrast-to-noise ratio (CNR) of MR images were quantitativlely analyzed using GE software Functool tool, four experienced radiologists and three radiotechnologists qualitatively evaluated image quality in terms of image artifacts, lesion conspicuity and rectal wall. These data were analysed by using ANOVA and Freedman test with each b-value(p<0.05). Contrast to noise ratio of rectum, bladder and tumor in b-value 1000 were 27.21, 24.44, respectively(p<0.05) and aADC value was $0.73\times10^{-3}$. As a qualitative analysis, the conspicuity and discrimination from the rectal wall of lesions were high results as $4.0\pm0.14$, $4.4\pm0.16$ on b-value 1000(p<0.05), image artifacts were high results as $4.8\pm0.25$ on b-value 2000(p<0.05). In conclusion, DWI was provided useful information with depicting the pre-operative detection of rectal cancers, High-b-value 1000 image was the most excellent DWI value.