• Title/Summary/Keyword: feeder system

Search Result 485, Processing Time 0.022 seconds

An feeder Automation System Using Active Database (능동 데이터베이스 이용한 배전선로 운전자동화)

  • 최상열
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.5
    • /
    • pp.94-102
    • /
    • 2003
  • This paper presents active management of feeder automation systems using active database. DAS(Distribution Automation System) has been managed for feeder automation in passive manner. Therefore, feeder automation system has to be managed by operator when feeder overloadings is detected. It may be possible for propagating the feeder overloadings area by operator's mistake. To overcome this defect, the author proposed the feeder automation technique with active manner to obtain feasible feeder reconfiguration. Active database can manage feeder automation system by data driven monitoring of events and by corresponding actions without operator's intervening. To manage feeder automation system with active manner, production rule, active rule manager are designed. And active database system architecture for feeder automation system is proposed. Test results on the KEPCO's 108 bus distribution system show that the performance is efficient and robust.

Control Algorithm of Hybrid System for Feeder Flow Mode Operation in Microgrid (마이크로그리드에서 하이브리드 시스템의 Feeder Flow Mode 운영을 위한 제어 알고리즘)

  • Moon, Dae-Seong;Seo, Jae-Jin;Kim, Yun-Seong;Won, Dong-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • Active power control scheme for distributed generation in microgrid consists of feeder flow control and unit power control. Feeder flow control is more useful than the unit power control for demand-side management, because microgrid can be treated as a dispatchable load at the point of common coupling(PCC). This paper presents detailed descriptions of the feeder flow control scheme for the hybrid system in microgrid. It is divided into three parts, namely, the setting of feeder flow reference range for stable hybrid system operation, feeder flow control algorithm depending on load change in microgrid and hysteresis control. Simulation results using the PSCAD/EMTDC are presented to validate the inverter control method for a feeder flow control mode. As a result, the feeder flow control algorithm for the hybrid system in microgrid is efficient for supplying continuously active power to customers without interruption.

Reliability analysis of the switch installation in the main feeder and in the radial/loop lateral feeders in distribution system (간선 및 분기선의 개폐기 설치 효과 분석(II))

  • Cho, Nam-Hun;O, Jae-Hyeong;Lee, Heung-Ho;Ha, Bok-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.83-86
    • /
    • 2002
  • In this study, we evaluate the effectiveness of a switch installation between on the radial and loop lateral feeders to increase reliability by decreasing the duration of the outage. These results can help power utility to design the switch layouts on the radial and loop lateral feeder system.

  • PDF

A Machine Vision System for Inspecting Tape-Feeder Operation

  • Cho Tai-Hoon
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.6 no.2
    • /
    • pp.95-99
    • /
    • 2006
  • A tape feeder of a SMD(Surface Mount Device) mounter is a device that sequentially feeds electronic components on a tape reel to the pick-up system of the mounter. As components are getting much smaller, feeding accuracy of a feeder becomes one of the most important factors for successful component pick-up. Therefore, it is critical to keep the feeding accuracy to a specified level in the assembly and production of tape feeders. This paper describes a tape feeder inspection system that was developed to automatically measure and to inspect feeding accuracy using machine vision. It consists of a feeder base, an image acquisition system, and a personal computer. The image acquisition system is composed of CCD cameras with lens, LED illumination systems, and a frame grabber inside the PC. This system loads up to six feeders at a time and inspects them automatically and sequentially. The inspection software was implemented using Visual C++ on Windows with easily usable GUI. Using this system, we can automatically measure and inspect the quality of ail feeders in production process by analyzing the measurement results statistically.

Reliability analysis of the switch installation in the main feeder and in the radial/loop lateral feeders in distribution system (간선 및 분기선의 개폐기 설치 효과 분석(I))

  • Cho, Nam-Hun;O, Jae-Hyeong;Lee, Heung-Ho;Ha, Bok-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.79-82
    • /
    • 2002
  • The addition of switches to a distribution feeder does, in general, increase reliability by decreasing the duration of the outage of many to the customers on the feeder. To cover its service area so that feeder-level delivery reaches sufficiently close to all customers, feeders typically split their routes many times, in what is often called a lateral feeder. It is interesting to note, however, that the effectiveness of a switch is very much dependent on the types of lateral feeder. The types of lateral are classified into two types. The first is loop lateral feeder that can connect its load to an adjacent feeder through a tie line in case that a fault occurs in its feeder and it is laid out so that every feeder has complete fault backup through re-switching of its loads to other sources like a main feeder. The second is the radial lateral feeder cannot connect its load to an adjacent line, no provision is made for contingency backup of feeders. There are no other circuits in the radial lateral feeder form which to restore power. In this study, we evaluate the effectiveness of a switch installation between on the radial and loop lateral feeders to increase reliability by decreasing the duration of the outage. These results can help power utility to design the switch layouts on the radial and loop lateral feeder system.

  • PDF

Planning of Part Feeder and Design of a Data Base for Part Feeder Planning System (자동 부품 정렬기 응용계획과 전용 DB 설계)

  • Guk, Geum-Hwan;Park, Yong-Taek
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.7
    • /
    • pp.116-124
    • /
    • 2002
  • The planning of part feeder and other manufacturing automation equipments is almost always underestimated. Planning ahead for those crucial pitfalls can permit steps to take to minimize heir impacts, especially if the problems can be discovered in the planning phase, not on the shop floor. Planning process is an engineering process, namely a series of trade-offs. The effective trade-offs in the shortest amount of time can be possible with the help of a computer-aided ngineering (CAE) technique. The main parts of CAE fur part feeder are database system of fabricated workpiece parts, part feeders, part feeder components. In this study, a planning process of part feeder is presented. Especially, a systematic analysis of workpiece parts and part feeders is performed for the design of databases of CAE system.

A Novel Feeder-Free Culture System for Expansion of Mouse Spermatogonial Stem Cells

  • Choi, Na Young;Park, Yo Seph;Ryu, Jae-Sung;Lee, Hye Jeong;Arauzo-Bravo, Marcos J.;Ko, Kisung;Han, Dong Wook;Scholer, Hans R.;Ko, Kinarm
    • Molecules and Cells
    • /
    • v.37 no.6
    • /
    • pp.473-479
    • /
    • 2014
  • Spermatogonial stem cells (SSCs, also called germline stem cells) are self-renewing unipotent stem cells that produce differentiating germ cells in the testis. SSCs can be isolated from the testis and cultured in vitro for long-term periods in the presence of feeder cells (often mouse embryonic fibroblasts). However, the maintenance of SSC feeder culture systems is tedious because preparation of feeder cells is needed at each subculture. In this study, we developed a Matrigel-based feeder-free culture system for long-term propagation of SSCs. Although several in vitro SSC culture systems without feeder cells have been previously described, our Matrigel-based feeder-free culture system is time- and cost-effective, and preserves self-renewability of SSCs. In addition, the growth rate of SSCs cultured using our newly developed system is equivalent to that in feeder cultures. We confirmed that the feeder-free cultured SSCs expressed germ cell markers both at the mRNA and protein levels. Furthermore, the functionality of feeder-free cultured SSCs was confirmed by their transplantation into germ cell-depleted mice. These results suggest that our newly developed feeder-free culture system provides a simple approach to maintaining SSCs in vitro and studying the basic biology of SSCs, including determination of their fate.

Study on Optimal Design of Bulk Solids Feeder for Automatic filling system (자동충전시스템을 위한 벌크 솔리드 피더의 최적설계)

  • Ban, Kap-Soo;Yun, Jong-Hwan
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.16 no.4
    • /
    • pp.133-140
    • /
    • 2013
  • This paper presents an overview of the concepts of optimal feeder design in relation to the loading of bulk solids for Automatic filling system that should be control the amount of goods and packaging to seal. Feeder modular device, important parts of the package, so in order to perform a conceptual design optimization techniques are applied in two steps. First of all derive the problems through structural analysis for the conceptual model of vibrating feeder. Secondly derive reasonable design model based on the results of the structural analysis of modified boundary shape and then verify it. The proposed system has the following goal that is satisfies the dynamic stability with minimum weight and optimization of the shape. As a result, the weight reduction of feeder is 2.1% and 7% increase in the natural frequency.

Structural and Dynamic Characteristic Analysis for Automatic Magazine Feeder in Automation Assembly System for LED Convergency Lighting (LED 융합조명의 자동화 조립 시스템에서 전자동 매거진 피더에 관한 구조해석과 동특성 분석)

  • Choo, Se-Woong;Jeong, Sang-Hwa
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.1
    • /
    • pp.23-33
    • /
    • 2018
  • In the general manual feeder of an LED lighting assembly system, many workers are needed to supply parts to the main conveyor. The automatic feeder for modern automation lighting assembly systems consists of a completely automated feeding system and a magazine system that supplies the parts automatically. A standardized LED panel and diffusion cover is stacked in the cartridge of the magazine system. The structural safety of the automatic feeding system with regard to handling the load from the panels and covers stored in the cartridge should be guaranteed. LED convergency lighting modules are assembled using two LED panels and one diffusion cover in an automatic feeder. In this study, the structural safety and fatigue life of the automatic feeder and magazine were analyzed by considering the load generated in the automatically assembled LED convergency lighting system. In addition, the dynamic behavior of each auto-feeding system and magazine delivery system was visualized, and the working process was evaluated via dynamic simulation using a virtual engineering method. A tack time table for automatic feeding systems was derived by developing a virtual prototype.

Development of Delta-I ground fault Protective Relaying Scheme for DC Traction Power Supply System (비접지 DC 급전시스템에서의 Delta-I 지락보호계전 시스템)

  • Chung, Sang-Gi;Kwon, Sam-Young;Jung, Ho-Sung;Kim, Ju-Rak
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.12
    • /
    • pp.529-535
    • /
    • 2006
  • In DC tracking power supply system, ground faults are currently detected by the potential relay, 64P. Though 64P relay detects ground fault, it cannot identify the faulted region which causes long traffic delays and safety problem to passengers. A new ground fault protective relay scheme, ${\Delta}I$ ground fault protective relay, that can identify the faulted region is presented in this paper. In ${\Delta}I$ ground fault protective relaying scheme, ground fault is detected by 59, overvoltage relay, which operates ground switch installed between the negative bus and the ground. It preliminarily chooses the faulted feeder after comparing the current increases among feeders and trips the corresponding feeder breaker. After some time delay, it then recloses the breaker if it finds the preselected feeder is not the actual faulted feeder. Whether or not the preselected feeder is the actual faulted feeder is determined by checking the breaker trip status in the neighboring substation in the direction of the tripped breaker. If the corresponding breaker in the neighboring substation is also tripped, it finally judges the preselected feeder is actually a faulted feeder. Otherwise it recloses the tripped breaker. Its algorithms is presented and verified by EMTP simulation.