• Title/Summary/Keyword: fault location

Search Result 474, Processing Time 0.035 seconds

Utilization of Energy Storage System based on the Assessment of Area of Severity in Islanded Microgrid

  • Lee, Kyebyung;Yoon, Minhan;Park, Chang-Hyun;Jang, Gilsoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.569-575
    • /
    • 2017
  • This paper proposes a method to utilize an energy storage system (ESS) based on the assessment of an area of severity (AOS) to voltage sag. The AOS is defined as a set of the fault positions that can cause voltage sags at many buses simultaneously. The assessment of AOS helps to determine an optimal location of ESS installation to minimize the expected sag frequency (ESF) at concerned buses. The ESS has the ability not only to play traditionally known roles but also to mitigate voltage sag impact on renewable energy sources (RES) in the islanded microgrid. Accordingly, using the proposed method the ESS has additional features to prevent the operation failure of RESs and improve the stability of the microgrid. In order to verify the presented method, a case study was conducted on the sample microgrid system that is modified from an IEEE 57-bus system.

Establishment of Diagnostic Criteria in the Preventive Diagnostic System for the Power Transformer (전력용 변압기 예방진단새스템의 진단기준치 실정)

  • Kweon Dong-Jin;Koo Kyo-Sun;Kwak Joo-Sik;Woo Jung-Wook;Kang Yeon-Wook
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.9
    • /
    • pp.449-456
    • /
    • 2005
  • The preventive diagnostic technique prevents transformers from power failure through giving alarm and observing transformers in service. And it helps to establish the plan for optimum maintenance of the transformer as well as to find location or cause of fault using accumulated data. Data detection and experience of the preventive diagnostic system need to establish the preventive diagnostic algorithm regarding interrelationship between detected data and deterioration of equipment. Therefore in-depth analysis about the preventive diagnosis system is required. KEPCO has adopted the preventive diagnostic system at nine 345kV substations since 1997. Techniques for component sensors of the preventive diagnosis system were settled but diagnosis algorithm, diagnostic criteria and practical use of accumulated data are not yet established. This paper, to build up the base of preventive diagnostic algorithm for the Power transformer. investigated the preventive diagnostic criteria for the power transformer.

Development of Fault Location Technology for Underground Power Cable (지중송전선 고장점 탐색 기술 개발)

  • Lee, Jae-Duck;Ryoo, Hee-Suk;Jung, Dong-Hak;Choi, Sang-Bong;Nam, Kee-Young;Jeong, Seong-Hwan;Kim, Dae-kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.113-115
    • /
    • 2005
  • 전력케이블, 특히 지중 송전케이블은 사고 발생시 그 파급효과가 크기 때문에 빠르고 정확한 고장점의 탐지가 필요하다. 본 논문에서는 on-line으로 지중 케이블의 상태를 모니터링하면서 사고 발생시에는 기록된 데이터를 분석하여 고장점을 찾을 수 있도록 하는 고장점 탐지 장치 개발에 관하여 언급한다. 케이블의 고장점 탐색 기술 개발을 위하여 단락 사고를 모의할 수 있는 모의 고장 발생 시스템을 구성하여 인위적인 고장발생을 할 수 있도록 하였으며 고장시 발생하는 신호를 측정하여 측정된 신호로부터 고장 발생 지점을 보다 정확하게 찾아내는 신호처리 기술을 연구하였다. 본 연구를 통하여 개발된 고장점 탐색장치는 정밀하게 사고지점을 찾아낼 수 있음을 보여주었으며 실제 전력 공급 계통에 손쉽게 설치할 수 있는 장점을 가지고 있다. 이하에 송전선 고장점 위치 계산을 위하여 개발된 고장점 탐색 기술에 관하여 언급한다.

  • PDF

Analysis on the Protective Coordination of between the Protection Devices due to Location of Superconducting Fault Current Limiter in Power Distribution System (배전계통에 초전도한류기 도입에 따른 보호기기간의 보호협조 분석)

  • You, Il-Kyoung;Kim, Jin-Seok;Kim, Myoung-Hoo;Lim, Sung-Hun;Moon, Jong-Fil;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.6_7
    • /
    • 2009
  • 배전계통에서 수요의 증가와 분산전원의 증가로 대용량 변압기의 적용이 불가피하게 되었다. 그러나, 대용량 변압기로 교체할 경우 기기가 갖는 임피던스가 작아져 배전계통에 고장발생시 고장전류의 크기가 증가되여 기존에 설치된 차단기 및 보호기기의 차단용량 초과로 인해 교체에 따른 경제적 비용 상승이 우려된다. 따라서, 대용량 변압기 적용시 고장전류 증가 문제를 해결하기 위한 방안 중 하나로 초전도한류기를 설치하는 방안을 검토하고 있다. 그러나, 초전도한류기는 고장전류의 크기에 따라 ��치시 임피던스의 크기가 다르게 된다. 이로 인해 고장전류의 값이 달라지며, 기존의 보호기기의 동작이 달라진다. 따라서 본 논문에서는 배전계통에 초전도한류기 도입 위치별 적용 할 경우 기존 보호협조에서 야기될 수 있는 문제점을 실험 및 PSCAD/EMTDC를 이용하여 분석하였다. 그 결과 초전도한류기 도입으로 인해 고장전류 크기가 감소하여 기존의 보호기기의 동작시간이 지연되는 것을 알 수 있었다.

  • PDF

Design of Circuit for Underground Power Cable Fault Location (지중송전선 고장점 탐색을 위한 측정 회로 설계)

  • Lee, Jae-Duck;Lee, Hee-Suk;Jung, Dong-Hak;Choi, Sang-Bong;Nam, Kee-Young;Jeong, Seong-Hwan;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.119-121
    • /
    • 2005
  • 전력케이블, 특히 지중 송전케이블은 사고발생시 그 파급효과가 크기 때문에 빠르고 정확한 고장점의 탐지가 필요하다. 본 논문에서는 지중 케이블의 고장 위치를 파악하기 위해 필요한 신호를 계측하고 이를 빠른 시간 내에 저장하여 사고 발생 후 이를 분석하여 고장점을 찾을 수 있도록 하는 고장점 탐지 장치를 위한 회로 설계에 대하여 언급한다. 케이블의 고장점 탐색 기술 개발을 위해서는 고장시에 발생하는 과도현상을 기록할 수 있도록 회로를 설계해야 하는 바 센서 구성과 입력 회로반의 설계, 데이터 저장 및 분석을 위한 회로의 설계는 고장점 탐색 장치 개발에 있어 필수적인 기술이다. 개발된 지중 송전선 고장점 탐색을 위한 측정회로는 사고지점 계산을 위해 필요한 신호측정에 효과적이며 실제 전력 공급 계통에 손쉽게 설치할 수 있는 장점을 가지고 있다. 이하에 지중송전선 고장점 탐색을 위한 측정 회로 설계에 관하여 언급한다.

  • PDF

Partial Discharge Localization Based on Detailed Models of Transformer and Wavelet Transform Techniques

  • Hassan Hosseini, Seyed Mohammad;Rezaei Baravati, Peyman
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1093-1101
    • /
    • 2015
  • Partial Discharge (PD) is a physical phenomenon, which causes defects and damages to the insulation. This phenomenon is regarded as the most important source of fault and defect in power transformers. Therefore, methods of high speed and precision are considered of special importance for the maintenance of transformers in localization of the origin of partial discharge. In this paper, the transformer winding is first modeled in a transient state by using RLC ladder network and multiconductor transmission line (MTL) models. The parameters of the two models were calculated by Ansoft Maxwell software, and the simulations were performed by Matlab software. Then, the PD pulses were applied to the models with different widths of pulses. With regard to the fact that the signals received after the application of PD had a variable frequency nature over time, and based on the wavelet transform and signal energy, a new method was presented for the localization of PD. Ultimately; the mentioned method was implemented on a 20 kV winding distribution transformer. Then, the performances of the models used in this paper, including RLC and MTL models, were compared in different frequency bands for the correct distinction of partial discharge location.

EMTP Simulations and Analysis for Detection of Fault Location in High Temperature Superconducting Cables (고온 초전도 케이블 고장점 탐지를 위한 EMTP 시뮬레이션 및 분석)

  • Bang, Su Sik;Jang, Seung-Jin;Lee, Geon Seok;Kwon, Gu-Young;Lee, Yeong Ho;Hwang, Min-Jae;Sohn, Song-ho;Park, Kijun;Shin, Yong-June
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.357-358
    • /
    • 2015
  • 본 논문에서는 고온 초전도 케이블 고장점 탐지를 위해 시간-주파수 반사파 계측법(Time-Frequency Domain Reflectometry)을 적용하여 EMTP 시뮬레이션을 수행하고, 고온 초전도 케이블에 적합한 가우시안 첩 포락선 선형 기준 신호를 제시하였다. 고온 초전도 케이블을 EMTP로 모델링하여 TFDR 기법을 통해 케이블의 종단점을 추정하고 기준 신호의 전파 속도를 계산하였다. EMTP를 활용하여 국부적 결함이 발생한 고온 초전도 케이블을 모델링하였고, 결함 발생 케이블의 고장점 탐지 시뮬레이션 결과를 확인하였다.

  • PDF

Research location & voice recognition disabled accessibility smartphones and database connection (위치·음성인식된 장애인 스마트폰과 장애인 편의시설DB 연결 연구)

  • Yang, Sung-Yong;Park, Dea-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.205-208
    • /
    • 2013
  • Number of disabled persons in Japan that have been registered in 2011 was about 2.5 million people, it is continuously increasing. Given the potential failure considering the aging, to increase more and more. This fault is open, and how to use the facilities, we examined Disabled Facilities DB how to build, how to take advantage. In the development of information technology, the use of technology to increase smartphone, fused evolves, disabled and was able to get the information easily. It is possible to take advantage of this amenities DB, to ensure convenient facilities for handicapped and provide equipment and position information of the user easily by using the audio position.

  • PDF

Electromagnetic Tomography Using Finite Element Method (유한요소법을 이용한 전자탐사 토모그래피 연구)

  • Son, Jeong-Sul;Song, Yoon-Ho;Kim, Jung-Ho
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.185-190
    • /
    • 2007
  • In this study, we developed the 2.5D EM modeling and inversion algorithm for cross-hole source and receiver geometry. Considering the cross-hole environment, we use a VMD (vertical magnetic dipole) as a source and vertical magnetic fields as a measuring data. Developed inversion algorithm is tested for the isolated block model which has a conductive and a resistivity anomaly respectively. For the conductive anomaly, its size and resistivity are inverted well on the inversion results, while for the resistive anomaly, the location of anomalous block is shown on the inverted section, but its values are far from the exact value. Furthermore, artificial conductive anomalies are shown around the resistive anomalous zone. If we consider the inversion artifact shown in the test inversion of restive block, it is almost impossible to image the resistive zone. However, the main target of EM tomography in the engineering problem is conductive target such as fault zone, and contaminated zone etc., EM tomography algorithm can be used for detecting the anomalous zone.

  • PDF

Detection and Location of Open Circuit Fault by Space Search (Space Search에 의한 회로의 단선 결함을 발견 및 위치 검색법)

  • Han, Kyong-Ho;Kang, Sang-Won;Lee, In-Sung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.2E
    • /
    • pp.43-49
    • /
    • 1995
  • In this paper a space search technique is used to detect and locate the faults of the circuit interconnections. The circuit interconnections are represented by the tree structure and the tree space is searched to detect and locate the open faults of the circuit interconnections. The breadth search is used to detect the open faults and reduce the space size. The depth search is used to locate the open faults.

  • PDF