• Title/Summary/Keyword: fault density

Search Result 187, Processing Time 0.027 seconds

Fracture Developing History and Density Analysis based on Grid-mapping in Bonggil-ri, Gyeongju, SE Korea (경주시 봉길리 지역의 단열발달사 및 단열밀도 해석)

  • Jin, Kwang-Min;Kim, Young-Seog
    • The Journal of Engineering Geology
    • /
    • v.17 no.3
    • /
    • pp.455-469
    • /
    • 2007
  • The study area, Bonggil-ri, Gyeongju, SE Korea, is composed of Cretaceous sedimentary rocks, and Tertiary igneous rocks and dykes. A research on fracture developing history and density distribution was carried out on well exposed Tertiary granites. The fractures developed in this area have the following sequence; NW-SE trending duo-tile shear bands (set a), NNW-SSE trending extensional fractures (set d), WNW-ESE trending extensional or normal fractures (set b), NE-SW trending right-lateral fractures (set c), WNW-ESE trending reverse fault reactivated from normal faults (set e) and NW-SE trending left-lateral faults reactivated from shear bands (set a) under brittle condition. According to the result of fracture density analysis, the fracture density in this area depends on rock property rather than rock age, and also higher fracture density is observed around fault damage zones. However, this high fracture density may also be related to the cooling process associated with dyke intrusion as well as rock types and fault movement. Regardless of the reason of the high fracture density, high fracture density itself contributes to fluid flow and migration of chemical elements.

Electromagnetic Behavior of High-Tc Superconducting Fault Current Limiters under the Quench State (켄치 상태에서 고온 초전도 한류기의 전자기적 거동)

  • Hyo-Sang Choi
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.1
    • /
    • pp.38-42
    • /
    • 2004
  • In this paper we analyzed the electromagnetic behavior of a superconducting fault current limiter (SFCL) under the quench state using FEM. The analysis model used in this work is 5.5 KVA meander-line type SFCLs which are currently developed by Superconductor Power System Lab in Korea Electric Power Research Institute. Meshes of 3,650 triangular elements were used in the analysis of this SFCL. Analysis results showed that the distribution of current density was concentrated to inner curved line in meander-line type SFCL and the maximum current density was 14.61 A/$m^2$ and also the maximum Joule heat was 2,030 W/$m^2$ in this region. We think that the new and the modified structure must be considered for an uniform distribution of the electromagnetic field.

Improvement of Test Method for t-ws Falult Detect (t-ws 고장 검출을 위한 테스트 방법의 개선)

  • 김철운;김영민;김태성
    • Electrical & Electronic Materials
    • /
    • v.10 no.4
    • /
    • pp.349-354
    • /
    • 1997
  • This paper aims at studying the improvement of test method for t-weight sensitive fault (t-wsf) detect. The development of RAM fabrication technology results in not only the increase at device density on chips but also the decrease in line widths in VLSI. But, the chip size that was large and complex is shortened and simplified while the cost of chips remains at the present level, in many cases, even lowering. First of all, The testing patterns for RAM fault detect, which is apt to be complicated , need to be simplified. This new testing method made use of Local Lower Bound (L.L.B) which has the memory with the beginning pattern of 0(l) and the finishing pattern of 0(1). The proposed testing patterns can detect all of RAM faults which contain stuck-at faults, coupling faults. The number of operation is 6N at 1-weight sensitive fault, 9,5N at 2-weight sensitive fault, 7N at 3-weight sensitive fault, and 3N at 4-weight sensitive fault. This test techniques can reduce the number of test pattern in memory cells, saving much more time in test, This testing patterns can detect all static weight sensitive faults and pattern sensitive faults in RAM.

  • PDF

Simplified Impedance Modeling and Analysis for Inter-Turn Fault of IPM-type BLDC motor

  • Kim, Byeong-Woo;Kim, Kyung-Tae;Hur, Jin
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.10-18
    • /
    • 2012
  • This paper proposes a finite element method (FEM)-based model of an interior permanent magnet (IPM)-type BLDC motor having stator inter-turn faults. We also propose impedance modeling of the magnetic characteristics. By integrating the developed model with a current-controlled voltage source inverter (CCVSI) model, the distributed characteristics of an inter-turn fault operated by a six-switch inverter are investigated considering speed control. Moreover, this paper presents the flux density distribution and torque characteristics for analyzing the inter-turn fault of an IPM-type BLDC motor. Additionally, fault impedance is required to calculate the circulating current that causes magnetic distortion. Thus, this paper proposes a method for estimating the circulating current taking into account the voltage at the shorted turn and the rotating speed. The analysis data were verified experimentally.

Development of a hight Impedance Fault Detection Method in Distribution Lines using Neural network (신경회로망을 이용한 배전선로 고저항 사고 검출 기법의 개발)

  • ;黃義天
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.2
    • /
    • pp.212-212
    • /
    • 1999
  • This paper proposed a high impedance fault detection method using a neural network on distribution lines. The v-I characteristic curve was obtained by high impedance fault data tested in various soil conditions. High impedance fault was simulated using EMTP. The pattern of High Impedance Fault on high density pebbles was taken as the learning model, and the neural network was valuated on various soil conditions. The average values after analyzing fault current by FFT of evenr·odd harmonics and fundamental rms were used for the neural network input. Test results were verified the validity of the proposed method.

FAULT DISPLACEMENT OF WENCHUAN EARTHQUAKE OBSERVED BY ALOS PALSAR

  • Won, Joong-Sun;Jung, Hyung-Sup
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.418-421
    • /
    • 2008
  • Wenchuan earthquake (Mw 7.9) occurred in Sichuan province, China, May 2008 had resulted in a huge fault displacement around the Lungmenshan fault. Preliminary results of the fault displacement observed by ALOS PALSAR interferometry are presented. The surface deformation by the Wenchuan earthquake was reported up to 10m consisting of thrust- and right-slip compnents. A significant reduction in ionospheric density was also reported. Twenty differential interferograms and twenty multiple aperture SAR interferometry (MAI) pairs were produced over four ALOS tracks. It was observed from differential interferograms that i) LOS deformation decreases steadily from northnorthwest of the Longmenshan fault to the fault, ii) the LOS deformation sharply increases at areas around the fault, and iii) the decrease of the LOS deformation is observed from the Longmenshan fault to the south-southeast of the fault. Horizontal movement of the reverse fault displacement can better be observed by MAI technique, and the MAI phases show that i) the south-southeast directional reverse fault displacement (negative along-track deformation for an ascending track) of the north-northwest block gradually increases to the Longmenshan fault, ii) the reverse fault movement of the south-southeast block is sharply reversed to the north-northwest of the fault, and iii) the northnorthwest movement gradually decreases to the south-southeast of fault. Although the Lonmenshan Fault line is a center of earthquake epicenter, the boundary of surface movement exists to the north-northeast of the fault. Since the ionosphere was not stable even forty days after the mainshock, MAI phases were seriously corrupted by ionospheric effect. It is necessary to acquire more data when the ionosphere recovered to a normal state.

  • PDF

Implementation of ATPG for IdDQ testing in CMOS VLSI (CMOS VLSI의 IDDQ 테스팅을 위한 ATPG 구현)

  • 김강철;류진수;한석붕
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.3
    • /
    • pp.176-186
    • /
    • 1996
  • As the density of VLSI increases, the conventional logic testing is not sufficient to completely detect the new faults generated in design and fabrication processing. Recently, IDDQ testing becomes very attractive since it can overcome the limitations of logic testing. In this paper, G-ATPG (gyeongsang automatic test pattern genrator) is designed which is able to be adapted to IDDQ testing for combinational CMOS VLSI. In G-ATPG, stuck-at, transistor stuck-on, GOS (gate oxide short)or bridging faults which can occur within priitive gate or XOR is modelled to primitive fault patterns and the concept of a fault-sensitizing gate is used to simulate only gates that need to sensitize the faulty gate because IDDQ test does not require the process of fault propagation. Primitive fault patterns are graded to reduce CPU time for the gates in a circuit whenever a test pattern is generated. the simulation results in bench mark circuits show that CPU time and fault coverage are enhanced more than the conventional ATPG using IDDQ test.

  • PDF

Fault-Tolerant Control of Five-Phase Induction Motor Under Single-Phase Open

  • Kong, Wubin;Huang, Jin;Kang, Min;Li, Bingnan;Zhao, Lihang
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.899-907
    • /
    • 2014
  • This paper deals with fault-tolerant control of five-phase induction motor (IM) drives under single-phase open. By exploiting a decoupled model for five-phase IM under fault, the indirect field-oriented control ensures that electromagnetic torque oscillations are reduced by particular magnitude ratio currents. The control techniques are developed by the third harmonic current injection, in order to improve electromagnetic torque density. Furthermore, Proportional Resonant (PR) regulator is adopted to realize excellent current tracking performance in the phase frame, compared with Proportional Integral (PI) and hysteresis regulators. The analysis and experimental results confirm the validity of fault-tolerant control under single-phase open.

Extraction of Lineament and Its Relationship with Fault Activation in the Gaeum Fault System (가음단층계의 선형구조 추출과 선형구조와 단층활동의 관련성)

  • Oh, Jeong-Sik
    • Journal of The Geomorphological Association of Korea
    • /
    • v.26 no.2
    • /
    • pp.69-84
    • /
    • 2019
  • The purpose of this study is to extract lineaments in the southeastern part of the Gaeum Fault System, and to understand their characteristics and a relationship between them and fault activation. The lineaments were extracted using a multi-layered analysis based on a digital elevation model (5 m resolution), aerial photos, and satellite images. First-grade lineaments inferred as an high-activity along them were classified based on the displacement of the Quaternary deposits and the distribution of fault-related landforms. The results of classifying the first-grade lineaments were verified by fieldwork and electrical resistivity survey. In the study area of 510 km2, a total of 222 lineaments was identified, and their total length was 333.4 km. Six grade lineaments were identified, and their total length was 11.2 km. The lineaments showed high-density distribution in the region along the Geumcheon, Gaeum, Ubo fault, and a boundary of the Hwasan cauldron consisting the Gaeum Fault System. They generally have WNW-ESE trend, which is the same direction with the strike of Gaeum Fault System. Electrical resistivity survey was conducted on eight survey lines crossing the first-grade lineament. A low-resistivity zone, which is assumed to be a fault damage zone, has been identified across almost all survey lines (except for only one survey line). The visual (naked eyes) detecting of the lineament was evaluated to be less objectivity than the automatic extraction using the algorithm. However, the results of electrical resistivity survey showed that first-grade lineament extracted by visual detecting was 83% reliable for inferred fault detection. These results showed that objective visual detection results can be derived from multi-layered analysis based on tectonic geomorphology.

Remediation of buried pipeline system subject to ground rupture using low-density backfill (경량채움재를 활용한 지반영구변위에 대한 지중관 시스템의 개량기법)

  • Choo, Yun-Wook;Abdoun, T.H.;O'Rourke, M.J.;Ha, D.
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.553-562
    • /
    • 2008
  • A remediation technique for buried pipeline system subject to permanent ground deformation is proposed. Specifically, EPS (expanded polystyrene) geofoam blocks are used as low density backfill, thereby reducing soil restraint and pipeline strains. In order to evaluate this remediation technique, a series of 12 centrifuge model tests with HDPE pipe were performed. The amount or spatial extent of the low density backfill was varied, as well as the orientation of the pipe with respect to the fault offset. Specifically, in the $-63.5^{\circ}$ test, the orientation was such that the pipe was placed in flexure and axial tension. The $-85^{\circ}$ orientation placed the pipe mainly in flexure. In all cases, the behavior of the remediated pipe was compared to that for the unremediated pipe. The geofoam backfill was successful in improving pipe behavior for two of the three pipe/fault orientations. However, for the $60^{\circ}$ orientation, the pipe buckled in compression irrespective of the geofoam backfill.

  • PDF