• Title/Summary/Keyword: fault core

Search Result 294, Processing Time 0.027 seconds

An Efficient Secrete Key Protection Technique of Scan-designed AES Core (스캔 설계된 AES 코아의 효과적인 비밀 키 보호 기술)

  • Song, Jae-Hoon;Jung, Tae-Jin;Jeong, Hye-Ran;Kim, Hwa-Young;Park, Sung-Ju
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.2
    • /
    • pp.77-86
    • /
    • 2010
  • This paper presents an efficient secure scan design technique which is based on a fake key and IEEE 1149.1 instruction to protect secret key from scan-based side channel attack for an Advanced Encryption Standard (AES) core embedded on an System-on-a-Chip (SoC). Our proposed secure scan design technique can be applied to crypto IP core which is optimized for applications without the IP core modification. The IEEE 1149.1 standard is kept, and low area, low power consumption, very robust secret-key protection and high fault coverage can be achieved compared to the existing methods.

Modified Current Differential Relay for Y-$\Delta$ Transformer Protection (Y-$\Delta$ 변압기 보호용 수정 전류차동 계전기)

  • Kang, Yong-Cheol;Jin, En-Shu;Lee, Byung-Eun
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.9-13
    • /
    • 2004
  • This paper proposes a modified current differential relay for Y-$\Delta$ transformer protection. The relay uses the same restraining current as a conventional relay, but the differential current is modified to compensate for the effects of the exciting current. A method to estimate the circulating component of the delta winding current is proposed. To cope with the remanent flux, before saturation, the core-loss current is calculated and used to modify the measured differential current. When the core then enters saturation, the initial value of the flux is obtained by inserting the modified differential current at the start of saturation into the magnetization cure. Thereafter, the core flux is then derived and used in conjunction with the magnetization curve to calculate the magnetizing current. A modified differential current is then derived that compensates for the core-loss and magnetizing currents. The performance of the proposed differential relay was compared against a conventional differential relay. Test results indicate that the modified relay remained stable during severe magnetic inrush and over-excitation because the exciting current was successfully compensated. The relay correctly discriminates magnetic inrush and over-excitation from an internal fault and is not affected by the level of remanent flux.

  • PDF

Efficient Fault Location Detecting Mechanism for Optical Submarine Cable (해저광케이블 고장지점 탐지기법)

  • Park, Hong-Tae;Yoo, Jae-Duck;Yoon, Suk-Min;Jo, Gi-Rayng;Shin, Hyun-Sik
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.1 no.1
    • /
    • pp.63-69
    • /
    • 2006
  • The optical submarine cable has a long distance cable and the repeater for optical amplification compared to territorial optical cable so conventional OTDR utilization for the optical submarine cable is limited. in case the optical core in the optical submarine cable system cut, by using Coherent OTDR that utilize OTDR path in repeater the cable fault point can be detected and in case the faulty of the copper tube in the cable that provide power for the repeater to amplify optical signal, the ways using the current/voltage characteristic, the capacitance per Km and so on is required. this report suggest efficient fault location detecting mechanism by categorized cable fault type.

  • PDF

Design of Enhanced IEEE 1500 Wrapper Cell and Interface Logic For Transition Delay Fault Test (천이 지연 고장 테스트를 위한 개선된 IEEE 1500 래퍼 셀 및 인터페이스 회로 설계)

  • Kim, Ki-Tae;Yi, Hyun-Bean;Kim, Jin-Kyu;Park, Sung-Ju
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.11
    • /
    • pp.109-118
    • /
    • 2007
  • As the integration density and the operating speed of System on Chips (SoCs) become increasingly high, it is crucial to test delay defects on the SoCs. This paper introduces an enhanced IEEE 1500 wrapper cell architecture and IEEE 1149.1 TAP controller for the wrapper interface logic, and proposes a transition delay fault test method. The method proposed can detect slow-to-rise and slow-to-fall faults sequentially with low area overhead and short test time. and simultaneously test IEEE 1500 wrapped cores operating at different core clocks.

The Anaysis of the Fault Currents According to Core-Saturation and Fault Angles in an Magnetic Shielding Type High-Tc Superconducting Fault Current Limiter (고온초전도한류기가 도입된 회로의 철심 포화와 사고각에 따른 사고전류 해석)

  • Lee, Chan-Joo;Lee, Seung-Je;Jang, Mi-Hye;Kim, Tae-Jung;Hyun, Ok-Bae;Ko, Tae-Kuk
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.401-404
    • /
    • 1999
  • 본 논문은 고온초전도한류기가 투입된 회로에 사고가 발생했을 경우 사고각에 따른 사고전류의 패턴에 관한 연구이다. 계통에 심각한 영향을 끼치는 이러한 사고전류의 순간 특성을 해석하기 위해 유도형 고온초전도한류기를 직접 제작하였으며 임의로 다른 각도에서 사고를 발생시켜 실험하였다. 임의의 사고각을 위해 triac으로 구성되어있는 위상각제어 및 사고 발생기를 부하와 직렬로 연결하였다. 또한, 순간적으로 큰 사고전류의 유입은 철심을 포화시키기에 충분하며 철심의 포화로 인해 상대투자율이 작아짐으로서 고온초전도한류기의 임피던스가 작게 발생하게 된다. 본 논문에서는 이러한 영향으로 인한 사고전류의 패턴에 관하여 연구하였다.

  • PDF

Improvement of Current Limiting and Recovery Characteristics in Series Connection Type SFCL with Added Third Winding (3차권선이 추가된 직렬연결형 초전도한류기의 전류제한 및 회복 특성 향상)

  • Ko, Seok-Cheol;Han, Tae-Hee;Lim, Sung-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.8
    • /
    • pp.62-68
    • /
    • 2014
  • The series connection type superconducting fault current limiter (SFCL) with added third winding, which was magnetically coupled in one iron core, was proposed. The proposed SFCL was expected to be more improved by just adding third winding into the conventional series connection type SFCL with two coils. To analyze the contribution of the third winding for the current limiting and the recovery characteristics of the SFCL, the short-circuit tests for the series connection type SFCL with the added third winding were performed together with the analysis on its electrical equivalent circuit. From the comparative analysis on the amplitude of the limited fault current and the power burden of the high-TC superconducting (HTSC) element comprising this SFCL, the improved current limiting and recovery characteristics of the series connection type SFCL using the third winding could be confirmed.

Energy-Efficient Fault-Tolerant Scheduling based on Duplicated Executions for Real-Time Tasks on Multicore Processors (멀티코어 프로세서상의 실시간 태스크들을 위한 중복 실행에 기반한 저전력 결함포용 스케줄링)

  • Lee, Kwan-Woo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.5
    • /
    • pp.1-10
    • /
    • 2014
  • The proposed scheme schedules given real-time tasks so that energy consumption of multicore processors would be minimized while meeting tasks' deadline and tolerating a permanent fault based on the primary-backup task model. Whereas the previous methods minimize the overlapped time of a primary task and its backup task, the proposed scheme maximizes the overlapped time so as to decrease the core speed as much as possible. It is analytically verified that the proposed scheme minimizes the energy consumption. Also, the proposed scheme saves up to 77% energy consumption of the previous method through experimental performance evaluation.

A case histories on the detection of weak zone using electrical resistivity and EM surveys in planned tunnel construction site (터널 건설 예정지구에서의 전기비저항 탐사와 전자탐사의 적용을 통한 연약대 탐지에 대한 사례 연구)

  • 권형석;송윤호;이명종;정호준;오세영;김기석
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.63-70
    • /
    • 2002
  • In tunnel construction, the information on the rock quality and the location of fault or fracture are crucial for economical design of support pattern and for safe construction of the tunnel. The grade of rock is commonly estimated through the observation with the naked eye of recovered cores in drilling or from physical parameters obtained by their laboratory test. Since drilling cost is quite expensive and terrains of planned sites for tunnel construction are rough in many cases, however, only limited information could be provided by core drilling Electrical resistivity and EM surveys may be a clue to get over this difficulty. Thus we have investigated electrical resistivity and EM field data providing regional Information of the rock Quality and delineating fault and fracture over a rough terrain. In this paper, we present some case histories using electrical resistivity and EM survey for the site investigation of tunnel construction. Through electrical resistivity and EM survey, the range and depth of coal seam was clearly estimated, cavities were detected in limestone area, and weak zones such as joint, fault and fracture have been delineated.

  • PDF

New Fault Current Fast Shutdown Scheme for Buck Converter (벅 컨버터의 새로운 고장전류 고속차단 기법)

  • Park, Tae-Sik;Kim, Seong-Hwan
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.68-73
    • /
    • 2019
  • This paper presents a novel fast shut-down scheme for Buck converter by using a coupled inductor. Generally, a controller for Buck converter stops generating PWM patterns in various fault cases: Overcurrent, Short circuit, or Overvoltage, but the inductor and capacitor keep supplying their stored energy to loads although the switching operations in Buck converter stopped. The stored energy in the inductor and capacitor could cause electrical stresses on breakers and safety problems. The main idea of the proposed fast shutdown scheme is to demagnetize the inductor core by using a coupled inductor, and its performance and operations are verified by using PSIM Simulation.

개선된 자속구속형 전류제한기의 동작 특성 분석

  • Kim, Yong-Jin;Du, Ho-Ik;Kim, Min-Ju;Lee, Dong-Hyeok;Han, Byeong-Seong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.215-215
    • /
    • 2009
  • Improved flux-lock type superconducting fault current limiter(SFCL) is composed of a series transformer and superconducting unit of the YBCO coated conductor. The primary and secondary coils in the transformer were wound in series each other through an iron core and the YBCO coated conductor was connected with secondary coil in parallel. In this paper, we investigated the current limiting characteristics through initial line current after fault initiation. through the analysis, it was shown that the smaller initial line current is superior to current limiting characteristics and a point of view of power burden of the YBCO coated conductor.

  • PDF