• 제목/요약/키워드: fault core

검색결과 293건 처리시간 0.022초

자속구속형 고온초전도 전류제한기의 동작전류와 각 코일의 전류분류 분석 (Analysis on Operational Current and Current Distribution between Two Coils of flux-lock Type SFCL)

  • 박충렬;임성훈;박형민;최효상;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제18권8호
    • /
    • pp.753-758
    • /
    • 2005
  • A flux-lock type superconducting fault current limiter(SFCL) consists of two coils, which are wound in parallel each other through an iron core, and a high-$T_c$ Superconducting(HTSC) thin film connected in series with coil 2. If the current of the HTSC thin film exceeds its critical current by the fault accident, the resistance of the HTSC thin film generated, and thereby the fault current can be limited by the impedance of the fluk-lock type SFCL. In this paper, we investigated the dependence of both the fault current limiting characteristics and the current distribution between two coils on the operational current of the flux-lock type SFCL through the equivalent circuit analyses and short circuit tests. From the comparison of both the results, the experimental results well agreed with the analyses for equivalent circuit.

CT와 CCVT의 오차를 고려한 거리 계전기의 응동 분석 (Analysis of the response of a distance relay considering the errors of CT and CCVT)

  • 강용철;정태영;최재선;강해권;김광무;장성일;김용균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.12-15
    • /
    • 2008
  • A distance relay has been widely used for transmission line protection. The distance relay detects a fault based on the calculated impedance i.e. the ratio of the voltage to the current measured from a current transformer (CT) and a coupling capacitor voltage transformer (CCVT), respectively. When a fault occurs and a CT saturates due to the magnitude of fault current, dc component, primary time constant, and the remanent flux of the iron core, the secondary current of a CT is distorted On the other hand, non-fundamental components generated during a fault can increase the error of a CCVT, particularly when a fault distance is short. The distortion of the current and voltage can cause mal-operation or the operating time delay of a distance relay. This paper describes the response of a distance relay considering the errors of a CT and a CCVT. The results indicate that the severe distortion of a CT and a CCVT have noticeable effect to a distance relay.

  • PDF

자속구속형 고온초전도 전류제한기의 인덕턴스 변화에 따른 전류제한 특성 분석 (Analysis of fault Current Limiting Characteristics due to Ratio of Inductances between Coil 1 and coil 2 in a Flux-lock Type SFCL)

  • 박충렬;임성훈;박형민;최효상;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제18권9호
    • /
    • pp.856-862
    • /
    • 2005
  • A flux-lock type SFCL consists of two coils, which are wound in parallel each other through an iron core, and a HTSC thin film connected in series with coil 2. If the current of the HTSC thin film exceeds its critical current by the fault accident, the resistance generated of the HTSC thin film, and thereby the fault current can be limited by the impedance of the flux-lock type SFCL. The amplitude of fault current can be set by the impedance of the flux-lock type SFCL. In this paper, we investigated the variance of the limiting current due to the ratio of inductances between coil 1 and coil 2 in the flux-lock type SFCL through the computer simulations and short circuit tests. In addition, both the simulation results and experimental ones were compared each other. From the comparison of both the results, the simulation results agreed well with the experimental ones.

THE APPLICATION OF PSA TECHNIQUES TO THE VITAL AREA IDENTIFICATION OF NUCLEAR POWER PLANTS

  • HA JAEJOO;JUNG WOO SIK;PARK CHANG-KUE
    • Nuclear Engineering and Technology
    • /
    • 제37권3호
    • /
    • pp.259-264
    • /
    • 2005
  • This paper presents a vital area identification (VAI) method based on the current fault tree analysis (FTA) and probabilistic safety assessment (PSA) techniques for the physical protection of nuclear power plants. A structured framework of a top event prevention set analysis (TEPA) application to the VAI of nuclear power plants is also delineated. One of the important processes for physical protection in a nuclear power plant is VAI that is a process for identifying areas containing nuclear materials, structures, systems or components (SSCs) to be protected from sabotage, which could directly or indirectly lead to core damage and unacceptable radiological consequences. A software VIP (Vital area Identification Package based on the PSA method) is being developed by KAERI for the VAI of nuclear power plants. Furthermore, the KAERI fault tree solver FTREX (Fault Tree Reliability Evaluation eXpert) is specialized for the VIP to generate the candidates of the vital areas. FTREX can generate numerous MCSs for a huge fault tree with the lowest truncation limit and all possible prevention sets.

비접촉식 전류 검출 장치에 관한 연구 (A Study on the Current Detector with Non Contact Type)

  • 김기준
    • 한국전기전자재료학회논문지
    • /
    • 제31권5호
    • /
    • pp.351-356
    • /
    • 2018
  • Commonly, a live-line alarm can be used to measure the electric field strength of a high-voltage system to calculate its current, but it is hard to detect the electric field of shielded cables or concealed structures, such as underground distribution cables. Current sensors can detect the magnetic field in a single core wire, but they cannot determine the magnetic field about a double-core wire because the currents flow in opposite directions. Therefore, it is very difficult to detect certain current problems, such as a fault current in an extension line comprised of a double line. In this paper, to ultimately develop a sensor that can detect the current regardless of line conditions, we used a simulation to determine the concentration of the magnetic field dependent on the distribution of the external magnetic field and the path of each line's core.

터널설계를 위한 모량단층의 지질공학적 연구 (An Engineering Geological Study of Moryang Fault for Tunnel Design)

  • 방기문;우상우
    • 지질공학
    • /
    • 제10권3호
    • /
    • pp.237-245
    • /
    • 2000
  • 본 연구는 터널설계와 관련하여 모량단층의 지질공학적 기본특성을 규명하고 터널설계시 기초자료 제공을 목적으로 수행되었다. 울산광역시 울주군 상북면 덕현리 덕현천 일대에 발달하는 모량단층의 특성을 규명하기 위하여 인공위성 영상을 이용한 선구조 분석, 지표지질조사, 전기비저항 탐사 및 3차원 해석, 시추조사, 광물분석 및 K-Ar절대연령측정 등을 수행하였다. 연구지역내에서 모량단층의 주향은 N20~30$^{\circ}$E, 경사는 70~90NW이고 단층폭은 약 20~60m, 최대 80m, 깊이는 50m이상인 것으로 규명되었다. 단층점토의 K-Ar 절대연령은 5,700$\pm$1.129만년, 1,900$\pm$0.380만년으로 측정되었으며, 수압파쇄시험 결과 최대수평응력의 방향은 N25$^{\circ}$E, N30$^{\circ}$E로 모량단층의 주향과 일치하였다.

  • PDF

자속구속형 전류제한기의 초기 사고전류 제한시점 변화 (Variance of Initial Fault Current Limiting Instant in Flux-lock Type SFCL)

  • 박충렬;임성훈;박형민;최효상;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제18권3호
    • /
    • pp.269-275
    • /
    • 2005
  • A flux lock-type SFCL consists of two coils which are wound in parallel each other through an iron core, and a HTSC thin film connects in series with coil 2. The operation of the flux-lock type SFCL can be divided into the subtractive polarity winding and the additive polarity winding operations according to the winding directions between coil 1, coil 2. When a fault occurs, the fault current in the HTS thin film exceeds the critical current so that resistance is generated in the HTS film, and thereby the fault current is limited by an instant rise in the impedance of the flux-lock type SFCL. We investigated he variances of initial fault current limiting instant according to the ratio of inductance of coil 1 and coil 2 in the flux-lock type SFCL. It was confirmed from experiments that the initial fault current limiting instant in the subtractive polarity and additive polarity windings were faster as the ratio of coil 2' inductance for coil 1's inductance increased. The 1st peak of fault current in case of the subtractive polarity winding was higher as the ratio of coil 2's inductance for coil 1's inductance increased. On the other hand, in case of the additive polarity winding, the 1st peak of fault current was lower.

직렬연결된 자속구속형 초전도 사고전류 제한기의 사고전류제한 특성 (Fault Current Limiting Characteristics of Series Connected Flux-Lock Type Superconducting Fault Current Limiters)

  • 임성훈;김재철
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.197-199
    • /
    • 2007
  • To apply the flux-lock type SFCL into power system, its current and voltage ratings are required to increase. Especially, in case of series connection of SFCLs, the countermeasure for simultaneous quenches must be considered. The structure, which each flux-lock type SFCL unit was wound in series on the same iron core, can induce the simultaneous quench of superconducting elements. Through the fault current limiting experiment for the suggested structure, it was confirmed that the even voltage burden among the superconducting elements comprising SFCLs could be made.

  • PDF

디지털 원자로보호계통 불가용도 평가 (An Unavailability Evaluation for a Digital Reactor Protection System)

  • 이동영;최종균;김지영;유준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.81-83
    • /
    • 2005
  • The Reactor Protection System (RPS) is a very important system in a nuclear power plant because the system shuts down the reactor to maintain the reactor core integrity and the reactor coolant system pressure boundary if the plant conditions approach the specified safety limits. This paper describes the unavailability assessment of a digital reactor protection system using the fault tree analysis technique. The fault tree technique can be expressed in terms of combinations of the basic event failures. In this paper, a prediction method of the hardware failure rate is suggested for a digital reactor protection system. and applied to the reactor protection system being developed in Korea.

  • PDF

고온초전도체를 이용한 차폐유도형 전류제한기의 설계 (design of shielded inductive SFCL made of high $T_c$ superconductor)

  • 임성훈;강형곤;박경국;한태희;조동언;한병성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 D
    • /
    • pp.1531-1533
    • /
    • 1998
  • In this paper, the characteristics of the shielded inductive superconducting fault current limiter was designed and simulated. Parameters of design for superconducting tube, core and primary coil were first determined. And then according to the system characteristics such as load resistance, fault angle and source voltage, the simple power system composed of shielded inductive FCL was simulated by computer-aided numerical analysis. The flowing currents under the fault condition can be limited to about 10 A.

  • PDF