• 제목/요약/키워드: fault contact

검색결과 142건 처리시간 0.031초

ETA를 통한 연구실험실 콘센트회로의 전기재해 분석 (Analysis of Electrical Accident for Outlet Circuit of Laboratory on ETA)

  • 김두현;김성철;박종영;김상철
    • 한국안전학회지
    • /
    • 제32권2호
    • /
    • pp.27-33
    • /
    • 2017
  • This study is intended to identify issues on the basis of investigating the actual state of laboratory environment and outlet circuit, and derive end states by expressing sequences from the initiating event of disaster to accident in leakage current, poor contact and overload through ETA(event tree analysis). To this end, this study investigated the actual state of electric equipment of laboratory at universities in all parts of country. And it is shown that most of them are failure in electric work and user negligence in the investigation of actual state. It is found that there is earth fault and defect in wire diameter in the failure of electric work and the problem of partial disconnection due to wire bundling and poor contact in user negligence. Outlet-related component, failure rate and initiating events are composed of a total of 41 initiating events, i.e., 30 internal initiating events and 11 external initiating events. And end states are composed of a total of 15 parts, i.e., 3 electric power parts and 12 safety parts. Earthing class 3 is the most important safety device against leakage current (initiating event). And in case of poor contact, it is necessary for manager to check thoroughly because there is no safety device. In case of overload/overcurrent, when high-capacity equipment is connected, a molded case circuit breaker, safety device, worked. However, in most cases, it is verified that this doesn't work. This study can be utilized as electric equipment safety guide for laboratory safety manager and managers.

고정밀 전류센서를 이용한 이중 차단용 전기화재 방재장치에 관한 연구 (A Study on Electrical Fire Disaster Prevention Device used in Double Circuit Break)

  • 박동필;곽동걸;정도영;김춘삼;신호준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2102-2103
    • /
    • 2008
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Device(RCD) of high sensitivity type used at low voltage wiring cuts off earth leakage and overload, but the RCD can't cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied low voltage distribution panel are prescribed to rated breaking time about 30[ms](KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To be improved on such problem, this paper is proposed to a electrical fire disaster prevention device(EFDPD) for a RCD trip or a self circuit-breaking function on electric arc or spark due to electrical fire. Some experimental results of the proposed apparatus is confirmed to the validity of the analytical results.

  • PDF

열화상 이미지를 이용한 배전 설비 검출 및 진단 (Detection and Diagnosis of Power Distribution Supply Facilities Using Thermal Images)

  • 김주식;최규남;이형근;강성우
    • 대한안전경영과학회지
    • /
    • 제22권1호
    • /
    • pp.1-8
    • /
    • 2020
  • Maintenance of power distribution facilities is a significant subject in the power supplies. Fault caused by deterioration in power distribution facilities may damage the entire power distribution system. However, current methods of diagnosing power distribution facilities have been manually diagnosed by the human inspector, resulting in continuous pole accidents. In order to improve the existing diagnostic methods, a thermal image analysis model is proposed in this work. Using a thermal image technique in diagnosis field is emerging in the various engineering field due to its non-contact, safe, and highly reliable energy detection technology. Deep learning object detection algorithms are trained with thermal images of a power distribution facility in order to automatically analyze its irregular energy status, hereby efficiently preventing fault of the system. The detected object is diagnosed through a thermal intensity area analysis. The proposed model in this work resulted 82% of accuracy of detecting an actual distribution system by analyzing more than 16,000 images of its thermal images.

Condition Monitoring of Low Speed Slewing Bearings Based on Ensemble Empirical Mode Decomposition Method

  • Caesarendra, W.;Park, J.H.;Choi, B.H.;Kosasih, P.B.
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.388-393
    • /
    • 2012
  • Vibration condition monitoring at low rotational speeds is still a challenge. Acoustic emission (AE) is the most used technique when dealing with low speed bearings. At low rotational speeds, the energy induced from surface contact between raceway and rolling elements is very weak and sometimes buried by interference frequencies. This kind of issue is difficult to solve using vibration monitoring. Therefore some researchers utilize artificial damage on inner race or outer race to simplify the case. This paper presents vibration signal analysis of low speed slewing bearings running at a low rotational speed of 15 rpm. The natural damage data from industrial practice is used. The fault frequencies of bearings are difficult to identify using a power spectrum. Therefore the relatively improved method of empirical mode decomposition (EMD), ensemble EMD (EEMD) is employed. The result is can detect the fault frequencies when the FFT fail to do it.

  • PDF

중성선 선로 전압강하를 이용한 단락사고 방지용 보호장치 개발 (Development of Prevention Apparatus for Short-Circuit Faults Using the Line Voltage Drop of Neutral Wire)

  • 곽동걸;김진환;이봉섭
    • 전기학회논문지
    • /
    • 제61권12호
    • /
    • pp.1953-1958
    • /
    • 2012
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with such electric faults, specially short circuit faults. Earth Leakage Circuit Breaker (ELB) and Molded_case Circuit Breaker (MCCB), that is, Residual Current Protective Devices (RCDs) used on low voltage distribution lines cut off earth leakage and overload, but the RCD can not cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied in low voltage distribution panel are prescribed to rated breaking time about 30ms(KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To improve such problem, this paper proposes a prevention apparatus using the line voltage drop of neutral wire and some semiconductor switching devices. Some experimental tests of the proposed apparatus confirm the validity of the analytical results.

저압 배전선로의 누전 및 배선용 차단기의 오동작 방지를 위한 고속형 전기안전 보호장치 (Electric Safety Protection Device of High Speed for Incapable Operation of ELB and MCCB Using the Low Voltage Distribution Line)

  • 곽동걸;정도영
    • 전기학회논문지
    • /
    • 제56권11호
    • /
    • pp.1925-1929
    • /
    • 2007
  • This paper is studied on a novel Electric Safety Protection Device (ESPD) of high speed for incapable operation of Earth Leakage Circuit Breaker (ELB) and Molded_case Circuit Breaker (MCCB) using the low voltage distribution line. The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Device (RCD), that is ELB and MCCB, of high sensitivity type used at low voltage wiring cuts off earth leakage and overload, but the RCD can't cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied low voltage distribution panel are prescribed to rated breaking time about 30[ms] (KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To be improved on such problem, this research development is proposed to a novel ESPD of high speed to trip of distribution line on electric arc or spark due to electrical fire. Some experimental results of the proposed ESPD are confirmed to the validity of the analytical results.

Petrology of enclaves in the granite around Bangeujin, Ulsan

  • Lee, Joon-Dong;Kim, Jong-Sun;Choi, Bo-Sim
    • 한국광물학회:학술대회논문집
    • /
    • 한국암석학회.한국광물학회 2000년도 공동학술발표회 논문집
    • /
    • pp.24-24
    • /
    • 2000
  • We studied about petrological characteristics of the Bangeujin granite belongs to porphyritic biotite granite, petrogenesis of the enclaves in the granite and contact metamorphism of the sedimentary rock around the granite. The enclaves in the granite are concentrated in the eastern part of the Mipo fault but in the western part, these are rare. The enclaves can be divided into three types according to the petrographical characteristics. These three types are: (1) enclaves having few phenocrysts and fine grained igneous texture and ellipsoid is predominant; (2) enclaves similar In petrographical characteristics and having many phenocrysts considered as being originated from the granitic host rock; and (3) enclaves corresponding to granite in mode composition, having large phenocrysts and of which the matrix is corresponding to fine granular. First two types are correspond to mafic micro granular enclaves and the third is corresponds to felsic microgranular enclaves. In addition, the felsic microgranular enclaves capture the mafic microgranular enclaves. The fact that the compositions of biotite and plagioclase in the enclaves are nearly identical with those of biotite and plagioclase in the granitic host rock is considered as the results of supporting magma mingling. The major elements show well the linear variations as the SiOz$.$ content increases. The rare earth elements content decrease with increasing SiOz content, interpreted as the results of magma mingling. Therefore, we can conclude that the Bangeujin granite captured the felsic microgranular enclaves formed by collapse of early chilled margin during the crystallization and there was magma mingling by the injection of the mafic magma after that time. In addition, these aspects are predominant in the eastern part of the Mipo fault is considered as related to the fault movement.vement.

  • PDF

배선용 차단기 개폐기구의 동특성 향상방안 및 해석 (Study on the Dynamic Modeling of MCCB)

  • 박진영;조해용
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권2호
    • /
    • pp.315-320
    • /
    • 2012
  • 일반적으로 저압 회로 보호용 장치로는 ICCB(Insulated case circuit breakers), PCB(Power circuit breakers) 그리고 MCCB(Molded case circuit breakers)를 들 수 있다. 이들 중 가장 보편적으로 사용되는 배선용 차단기(MCCB)는 휴즈 또는 개폐기의 단점인 안전성, 제어성, 협조성 등을 보완한 것이다. 차단기의 성능은 사고전류 발생 시 트립 동작이 순간적이고, 절연능력이 뛰어나야 하므로 매우 중요하다. 따라서 차단기의 개폐 성능은 매우 중요하므로 개폐 기구부의 접촉자 구조 및 접점 그리고 링크구조 등에 대한 기구학적 연구가 필요하다. 본 논문에서는 저압차단기의 기구적 동역학 모델링과 해석을 수행하여 가동자의 개리속도가 빠를수록 차단특성에 유리하다는 결론을 얻었으며, 실제 실험을 통하여 이를 검증하였다.

삼한(三韓) 장군(將軍) 광산(鑛山) 조사(調査) 보문(報文) (Report on the Sam Han Chang Gun Manganese Deposits)

  • 황인전
    • 자원환경지질
    • /
    • 제1권1호
    • /
    • pp.9-34
    • /
    • 1968
  • Manganese ore deposits of the Samhan Changgun Properties are located at the valley of west-lope-side of Changgun-bong (1132m) occupied over the Myon border between Sochon-myon and Jaesan-myon Pongwha-gun, Kyongsang-Pukdo. Geology of the more property and it's vicinity consists of Wonnan formation and Yulri formation of pre-Cambrain and Changgun limestone formation, Mica-schist formation, quartizite formation and Jaesan formation (containing coal bearing zone the unknown age. And granites and dykes were intruded into the above formation later. 1. Management deposits is embedded the formation of Janggun limestone especially Contact zone in the contact zone to of Chunyang Granite limestone enclosed by Granite, and Maginal zone of fault line in the limestone. Therefore, Chunyang Granite is Closely related to ore deposit. Pegmatite which is near by ore deposit was intruded before mineralization and it seems to be a channelway of ore solution. The most important ore deposits of property grouped into south deposit, east deposit, east-Gachon deposit, South-Gachon deposit, Durimgok deposit and West deposit, out-crops at several place. Besides these deposits there also are several prospects on outcrop scathered. Hydrothermal alteration take place strongly in the well rock and it's sequence are Characterized as following; 1) Dolomitization 2) Carbonization 3) Mamgamotozation 4) Pyritization 5) Silicification 6) Oxidation 2. The grade of manganese dioxide is up to Mn 45% in Maximum, but generally, averaging Mn 30~35% of high grade ore and averaging Mn 30~32% of manganese carbonates are mined in his property.

  • PDF

3상 저항가열식 전기히터의 화재예방을 위한 결함 진단장치 (Fault Diagnosis Device for Fire Prevention of the Resistance Heating Type three-Phase Electric Heater)

  • 이문형;김찬오
    • 전기학회논문지
    • /
    • 제66권11호
    • /
    • pp.1669-1674
    • /
    • 2017
  • In this study, We have discussed the development of a diagnostic device to detect and prevent electrical fire due to the arc caused by contact failure and partial disconnection at the connection part of the three-phase electric heater wiring used in the industrial field. The arc caused by contact failure and partial disconnection at the connection part of the electric heater shows a change in the current effective value. Therefore, it is possible to determine whether there exists a defect by analyzing the current unbalance factor and the number of current fluctuations with the diagnostic apparatus. The three-phase unbalanced heater is considered to be capable of determining defects through periodic measurement and trend analysis of the current unbalance factor. It is also expected that this device can be used not only for electric heaters but also for detection of defects in wiring and connections of electrical equipment having a characteristic of constant load current.