• Title/Summary/Keyword: fault contact

Search Result 142, Processing Time 0.027 seconds

Application of Geophysical Survey for Detecting the Skarn Ore Deposit (스카른광체를 탐지하기 위한 물리탐사 적용)

  • Park, Chung-Hwa;Jung, Yeon-Ho;Lee, Yong-Dong;Park, Jong-Oh
    • The Journal of Engineering Geology
    • /
    • v.20 no.1
    • /
    • pp.71-78
    • /
    • 2010
  • The Gagok mine is a contact metasomatic deposit, located at Gagok-myeon, Samcheok city and Cheoram-dong, Taebaek city, Gangwon province. The deposit lies within the limestone of Myobong and Pungchon formations, and exists the contact of intrusive granite porphyry. In order to determine the direction and extension of mineralization in the gallery and around the entrance of the ore deposit, we used the ground magnetic survey, the direct current (dc) resistivity survey using dipole-dipole array, and resistivity tomography survey. The ground magnetic survey did not detect the anomalous zone due to ore deposit, while the dc resistivity survey and resistivity tomography survey were successful in delineating the anomalous zone related to the extension of fault toward $N50^{\circ}W$.

Measurement of Bangudae Rock Joint Using Non-adhesive, Non-contact Inclinometer Slope Laser Measuring System (비부착, 비접촉 방식의 계측기를 이용한 반구대암각화 암반 절리면의 계측)

  • Kim, Jae Hyun;Lee, Sang Ok;Chung, Kwang Yong;Han, Min Su
    • Journal of Conservation Science
    • /
    • v.37 no.6
    • /
    • pp.617-625
    • /
    • 2021
  • Daegokcheon Stream in Daegok-ri, Ulju-gun, is an area with a developed valley and bedrock from Gajisan Provincial Park to the confluence of the Taehwa River across the Yangsan Fault. To measure the rock of Bangudae petroglyphs, the mineralogical weathering, joints, and scours or cavities at the bottom were confirmed. The measurement was carried out for a short period of time on the joint of the bedrock on which the Bangudae petroglyphs were engraved. Compared to the measured value obtained using existing optical fiber (Ch4 150 ㎛), a displacement value of 300 ㎛ was obtained using the non-attached, non-contact type of measuring instrument. In the future, it is inferred that this instrument could be used for various cultural properties if the HSV-value suitable for illuminance and various measurement experiences are stored.

Geology and Ore Deposit of Pocheon Iron Mine (포천광산(抱川鑛山)의 지질광상(地質鑛床))

  • Kanda, Yomoo
    • Economic and Environmental Geology
    • /
    • v.2 no.2
    • /
    • pp.53-67
    • /
    • 1969
  • Magnetite deposit of Pocheon Iron Mine is a contact replacement skarn deposit embedded in the carbonate rocks (limestone and dolomite) which are intruded by granite porphyry. The shape of ore bodies is sweet potato-like and/or irregular massive form; D-ore body, the biggest one is of $180m{\times}40m{\times}200m$ in size. The ore is in general of high grade. The location of the ore bodies is controlled by the fault which strikes north south and dips $60^{\circ}$ to $70^{\circ}$ to the west. A regular distribution of mineralized zones is recognized in order of outward (hanging wall side) from granite porphyry as follows: compact fine-grained skarn, limesilicates, magnetite ore body, marble, limesilicates, pyritized meta-sediments.

  • PDF

Analysis on System Effects of SUS Tube in Optical Fiber Composite Power Cable Systems Using EMTP (EMTP를 이용한 광 복합 지중송전케이블 광 유니트 금속관의 시스템 영향분석)

  • Jung, Chae-Kyun;Jang, Tai-In;Kang, Ji-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.9
    • /
    • pp.1180-1185
    • /
    • 2014
  • This paper describes the effects on SUS tube of power optical fiber composite cable on underground transmission lines. The effects on grounding, air gap between SUS tube and metal sheath, contact resistance between outer semi-conducting layer and metal sheath and grounding of SUS tube application or not are variously analysed using EMTP in normal operating condition as well as single line to ground fault. From these results, in this paper, the scheme for protecting the electrically abnormal phenomena will be established on power-optical fiber composite cable of underground transmission lines. This paper can contribute to specification of grounding reference of SUS tube of optical fiber composite power cable system.

KOMPSAT SATELLITE LAUNCH AND DEPLOYMENT OPERATIONS

  • Baek, Myung-Jin;Chang, Young-Keun;Lee, Jin-Ho
    • Journal of Astronomy and Space Sciences
    • /
    • v.16 no.2
    • /
    • pp.199-208
    • /
    • 1999
  • In this paper, KOMPSAT satellite launch and deployment operations are discussed. The U.S. Taurus launch vehicle delivers KOMPSAT satellite into the mission orbit directly. Launch and deployment operations is monitored and controlled by several international ground stations including Korean Ground Station (KGS). After separation from launch vehicle, KOMPSAT spacecraft deploys solar array by on-board autonomous stored commands without ground inter-vention and stabilizes the satellite such that solar arrays point to the sun. Autonomous ground communication is designed for KOMPSAT for the early orbit ground contact. KOMPSAT space-craft has capability of handing contingency situation by on-board fault management design to retry deployment sequence.

  • PDF

A Study on the Prevention of Crack Generated in Interface Cu and Epoxy with Painting of Carbon (카본 도포에 따른 Cu-Epoxy 접촉면에서 발생하는 크랙방지에 관한 연구)

  • 송재주;김성훈;황종선;박종광;한병성
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.7
    • /
    • pp.578-583
    • /
    • 2001
  • The bushing for high voltage and large and power should endure weight of itself and force of pushing from contact with circuit breaker. Like this, epoxy mold bushing has to be strong without fault. However, the external circumstances and internal factors was caused by partial discharge, flashover and dielectric breakdown. Therefore, to remove external factor of defect and to prevent the internal cracks and cavity generated from the contraction on interface of Cu-Epoxy, we should form semi-conductive layer on Cu bar by carbon. Then, the PD properties and the insulation qualities of epoxy mold type bushing was able to improved by roles of cushions for the direction of diameter and by effects fo natural sliding like as separated from conductor for the direction of length. So, in this work, we could prove the method of semi-conductive layer in making the long conductor.

  • PDF

Development of Diagnosis Algorithm for 25.8kV N2 insulated Pad-mounted Switchgear (25.8kV급 N2 절연 지중다회로 개폐기 진단알고리즘 개발)

  • Kim, Chun-Won;Jang, Sung-Il;Choi, Jung-Hwan;Kim, Kwang-Ho
    • Journal of Industrial Technology
    • /
    • v.34
    • /
    • pp.67-70
    • /
    • 2014
  • In this paper, we propose a diagnosis algorithm for 25.8kV $N_2$ insulated Pad-mounted Switchgear in oder to improve reliability by preventing of fault in advance. The proposed algorithm can diagnose the problems of Pad-mounted Switchgear such as gas leakage and VI(Vacuum Interrupter) trouble (contact abrasion, coil aging etc.) by using pressure sensor, stroke sensor and coil current sensor.

  • PDF

The Development of GTO circuit breaker for subway substation (지하철 변전소용 GTO 싸이리스터 차단기 개발)

  • Yun, J.H.;Choi, S.K.;Jung, M.K.
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.524-526
    • /
    • 1997
  • High speed DC circuit breakers (HSCB) are indispensable for protection of DC electric subway substations from fault current. However, the HSCB has mechanical contact to wear, which requires rather frequent maintenance, we have succeeded in developing and manufacturing a GTO DC circuit breaker using GTOs and ZnO varistors. In this paper, we describes the outline of the system itself, its characteristics and test data.

  • PDF

A Study on Improving Arc Quenching Performance of MCCB by FEM (유한요소법을 이용한 배선용 차단기의 아크소호 성능향상에 관한 연구)

  • Kim, Kil-Sou;Lim, Kee-Joe;Kang, Seong-Hwa;Cho, Hyun-Kil;Lee, Gang-Won;Park, Jung-Nam
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.51-54
    • /
    • 2001
  • This Paper is described basic principles of arc quenching in Molded Case Circuit Breaker. We analyzed magnetic blowout forces acting on the arc in contact system when circuit breakers interrupt fault currents in different three models by 3-D FEM(Finite Element Method). The interrupting time simulated is compared with that of short circuit tests. The results of this study derive valid of the simulation method and present the techniques to improve arc quenching performance.

  • PDF

Cross-sectional TEM Specimens Priparation of Precisely Selected Regions of Semiconductor Devices using Focused Ion Beam Milling

  • Kim, Jeong-Tae;Kim, Ho-Jeong;Jo, Yun-Seong;Choe, Su-Han
    • Korean Journal of Materials Research
    • /
    • v.3 no.2
    • /
    • pp.193-196
    • /
    • 1993
  • A procedure for preparing cross-sectional specimens for transmission electron microscopy(TEM)by focused ion beam(FIB)milling of specific regions of semiconductor devices is outlined. This technique enables TEM specimens to be pripared at precisely preselected area. In-situ #W thin film deposition on the top surface of desired site is complementally used to secure the TEM specimens to be less wedge shaped, which is main shortcoming of previous FIB-assisted TEM sample preparation technique. This technique is quite useful for the TEM sample priparation for fault finding and the characterization of fabrication process associated with submicron contact technologies.

  • PDF