• Title/Summary/Keyword: fault area

Search Result 805, Processing Time 0.024 seconds

The Analysis of Underground Utility Tunnel Positions using Lineament and GPR (선구조와 지하 투과 레이더를 이용한 지하공동구 위치 해석)

  • Jang, Ho-Sik;Seo, Dong-Ju
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.9 no.4
    • /
    • pp.142-150
    • /
    • 2006
  • In this study, GPR and lineament methods are used for the effective construction. GPR method is non-destructive testing to understand underground utility tunnel while lineament method is to understand locational environment. First, soil condition of the subject area is surveyed by location analysis. As the result of GPR survey, small-scale and large-scale of underground utility tunnel's location and scale were estimated. From the result of estimation, it is found that the main cause of underground utility tunnel's generation was not the effect of landslide or disturbed foundation from the excavation work but crack of shear & tension from the effect of fault movement which grew by insulation surroundings. From now on, this investigation method would be very useful in the survey and design stage on site for the effective construction and maintenance.

  • PDF

Seismic Design of Structures in Low Seismicity Regions

  • Lee, Dong-Guen;Cho, So-Hoon;Ko, Hyun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.4
    • /
    • pp.53-63
    • /
    • 2007
  • Seismic design codes are developed mainly based on the observation of the behavior of structures in the high seismicity regions where structures may experience significant amount of inelastic deformations and major earthquakes may result in structural damages in a vast area. Therefore, seismic loads are reduced in current design codes for building structures using response modification factors which depend on the ductility capacity and overstrength of a structural system. However, structures in low seismicity regions, subjected to a minor earthquake, will behave almost elastically because of the larger overstrength of structures in low seismicity regions such as Korea. Structures in low seismicity regions may have longer periods since they are designed to smaller seismic loads and main target of design will be minor or moderate earthquakes occurring nearby. Ground accelerations recorded at stations near the epicenter may have somewhat different response spectra from those of distant station records. Therefore, it is necessary to verify if the seismic design methods based on high seismicity would he applicable to low seismicity regions. In this study, the adequacy of design spectra, period estimation and response modification factors are discussed for the seismic design in low seismicity regions. The response modification factors are verified based on the ductility and overstrength of building structures estimated from the farce-displacement relationship. For the same response modification factor, the ductility demand in low seismicity regions may be smaller than that of high seismicity regions because the overstrength of structures may be larger in low seismicity regions. The ductility demands in example structures designed to UBC97 for high, moderate and low seismicity regions were compared. Demands of plastic rotation in connections were much lower in low seismicity regions compared to those of high seismicity regions when the structures are designed with the same response modification factor. Therefore, in low seismicity regions, it would be not required to use connection details with large ductility capacity even for structures designed with a large response modification factor.

Design for Self-Repair Systm by Embeded Self-Detection Circuit (자가검출회로 내장의 자가치유시스템 설계)

  • Seo Jung-Il;Seong Nak-Hun;Oh Taik-Jin;Yang Hyun-Mo;Choi Ho-Yong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.5 s.335
    • /
    • pp.15-22
    • /
    • 2005
  • This paper proposes an efficient structure which is able to perform self-detection and self-repair for faults in a digital system by imitating the structure of living beings. The self-repair system is composed of artificial cells, which have homogeneous structures in the two-dimension, and spare cells. An artificial cell is composed of a logic block based on multiplexers, and a genome block, which controls the logic block. The cell is designed using DCVSL (differential cascode voltage switch logic) structure to self-detect faults. If a fault occurs in an artificial cell, it is self-detected by the DCVSL. Then the artificial cells which belong to the column are disabled and reconfigured using both neighbour cells and spare cells to be repaired. A self-repairable 2-bit up/down counter has been fabricated using Hynix $0.35{\mu}m$ technology with $1.14{\times}0.99mm^2$ core area and verified through the circuit simulation and chip test.

Development of Optimized State Assignment Technique for Testing and Low Power (테스팅 및 저전력을 고려한 최적화된 상태할당 기술 개발)

  • Cho Sangwook;Yi Hyunbean;Park Sungju
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.1
    • /
    • pp.81-90
    • /
    • 2004
  • The state assignment for a finite state machine greatly affects the delay, area, power dissipation, and testabilities of the sequential circuits. In order to improve the testabilities and power consumption, a new state assignment technique . based on m-block partition is introduced in this paper. By the m-block partition algorithm, the dependencies among groups of state variables are minimized and switching activity is further reduced by assigning the codes of the states in the same group considering the state transition probability among the states. In the sequel the length and number of feedback cycles are reduced with minimal switching activity on state variables. It is inherently contradictory problem to optimize the testability and power consumption simultaneously, however our new state assignment technique is able to achieve high fault coverage with less number of scan nfp flops by reducing the number of feedback cycles while the power consumption is kept low upon the low switching activities among state variables. Experiment shows drastic improvement in testabilities and power dissipation for benchmark circuits.

the Applying Differences of Excepted Perils in the Rotterdam Rules (로테르담 규칙하에서의 면책사유의 적용상 특징)

  • JO, Jong-Ju
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.71
    • /
    • pp.147-170
    • /
    • 2016
  • International maritime law conventions concerned with cargo liabilities have sought to achieve solutions which will be acceptable to a wide range of states. The Rotterdam Rules was approved by the UN Assembly on 11 December 2008. The Rotterdam Rules are intended to replace The Hague and Hamburg Rules. This paper is comparing The Rotterdam Rules with The Hague and Hamburg Rules for the carrier' liabilities and exceptions in order to find carrier' liability System, the burden of proof and exceptions in the International maritime Rules. The purpose of this paper is considering the carrier's principal recourse for defending himself inmost cargo claims. The first area analyze the transfer of carrier's fundamental Liability system in the International Rules. The second is the matter on the appointment of proof in order to establish liability or to be relieve of liability. And the third is the change of the carrier's possible exclusions from liability in the International maritime Rules. From the result of the said analysis, my paper suggests differences of the exclusions in the Rotterdam Rules comparing with the Hague and Hamburg Rules, and features of the Rotterdam Rules appling exceptions on the basis of the Hague and Hamburg Rules with regard to carrier's liability and burden of proof. The former is the inclusion of three exclusions, the deleted natural fault, and The provision making the carrier responsible for the acts of its servants or agents in the 'fire on the ship' of the Rotterdam Rules. The latter is deleting the principle of overriding obligation related to carrier's obligation of seaworthiness in the Rotterdam Rules, the burden of proof being diverted from the carrier to the carrier and the shipper in the cargo damage caused by two factors(one for which the carrier was liable and the other for which it was excusable) in the new rules.

  • PDF

A Study on the Design of the Stern Stow Net (선미식 안강망 어구의 설계에 관한 연구)

  • 김진건
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.4
    • /
    • pp.343-352
    • /
    • 1999
  • Because stow net being used in now is doing throwing net and hauling net through a ship's side, the work is very complicated and the fishing boat needs many seamen and it could cause a loss of lives and ship in stormy weather. We are now using small mesh size 36~500mm and it even catches young fish, so we call it the fishing gear of resource reduction type.Therefore we must make manpower reduction in automatic operation, safe operation of throwing net and hauling net in the stern and the stern-typed stow net of resource management using large mesh. And we performed three-typed model tests to examine the fishing gear. The obtained results are as follows;1. The fishing gear being used in the ship's side type stow net has inappropriate standard and arrangement of the net, resistance increase of the fishing gear and frequent breakdown of the net.2. To supplement the fault of A-typed stow net, we schemed fishing gear developed as both B-type(12-seamed net) and C-types(8-seamed net) of the stern-typed stow net. 3. In model tests, C-typed model net(mesh size 40~1,600mm) was proved good fishing gear because the resistance in accordance with the flowing speed was comparatively small and it's mouth area was broad. 4. A-typed stow net had the spreading device attached to side panel of the net, but the stern-typed stow net had the spreading device consisted of 4 lines far behind about 6m from side panel of the net mouth. In the flowing speed 2knot, the spreading condition of fishing gear was proved batter than the former.

  • PDF

Redundancy operation method for a distributed public address system (분산형 전관방송 시스템의 이중화 운영 방법)

  • Ryu, Taeha;Kim, Seungcheon
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.8
    • /
    • pp.47-53
    • /
    • 2020
  • In the case of a failure due to equipment deterioration in the public address system or a worker's mistake during construction, broadcasting becomes impossible. In this situation, we have designed a more advanced management broadcast system that can broadcast. The broadcasting service is operated using main broadcasting device, and local broadcasting device operates separately only in the local area. If the main broadcasting device becomes inoperable, the procedure for transferring the control activates the device with the local broadcasting devices based on data backed up by the main controller. This paper proposes an improved method of the conventional emergency broadcasting device duplication method. The existing method could not use the standby equipment in the normal state, but in the proposed method, the standby equipment can be used as local broadcasting equipment in usually. This method enables stable system operation while minimizing resource waste due to redundant configuration of expensive devices.

Service Restoration In Distribution Networks Using Cyclic Best-First Search (순환적 최적우선탐색을 이용한 배전계통의 정전복구)

  • Choi, Sang-Yule
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.162-168
    • /
    • 2004
  • Service restoration is an emergency control in distribution control centers to restore out-of-service area as soon as possible when a fault occurs in distribution networks. Therefore, it requires fast computation time and high quality solutions for load balancing. In this paper, a load balance index and heuristic guided best-first search are proposed for these problem. The proposed algorithm consists of two parts. One is to set up a decision tree to represent the various switching operations available. Another is to identify the most effective the set of switches using proposed search technique and a feeder load balance index. Test results on the KEPCO's 108 bus distribution system show that the performance is efficient and robust.

Reproduction of Extreme Waves Caused by Typhoon MAEMI with Wave Hindcasting Method, WAM (I) - Corrections of directional spreading division and limitation on wave development of WAM model - (제3세대 파랑추산모형을 이용한 태풍매미의 극한파랑 재현 (I) - WAM 모형의 파향격자 분할법 및 파 발달 제한조건의 수정-)

  • Shin, Seung-Ho;Hong, Key-Yong;Choi, Hak-Sun;Noriaki Hashimoto
    • Journal of Navigation and Port Research
    • /
    • v.28 no.6
    • /
    • pp.557-564
    • /
    • 2004
  • The WAM wave model has been widely used for wave hindcasting in the ocean by many domestic and foreign researchers due to its relative simplicity and high accuracy. As this model was originally developed for the condition of deepwater and comparatively coarse grid size covering wide area, it might produce in a fault result caused by the improper distribution of directional spreading. We extensively investigated involved problems based on WAM Cycle 4 model and suggested the improved WAM model so that it is applicable to both shallow water sea and fine mesh wave simulation The modified W AM model is verified here by comparing the computed result with and the observed data at Ieodo Ocean Research Station for September of 2003.

PC Cluster Based Parallel Genetic Algorithm-Tabu Search for Service Restoration of Distribution Systems (PC 클러스터 기반 병렬 유전 알고리즘-타부 탐색을 이용한 배전계통 고장 복구)

  • Mun Kyeong-Jun;Lee Hwa-Seok;Park June Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.8
    • /
    • pp.375-387
    • /
    • 2005
  • This paper presents an application of parallel Genetic Algorithm-Tabu Search (GA-TS) algorithm to search an optimal solution of a service restoration in distribution systems. The main objective of service restoration of distribution systems is, when a fault or overload occurs, to restore as much load as possible by transferring the do-energized load in the out of service area via network reconfiguration to the appropriate adjacent feeders at minimum operational cost without violating operating constraints, which is a combinatorial optimization problem. This problem has many constraints with many local minima to solve the optimal switch position. This paper develops parallel GA-TS algorithm for service restoration of distribution systems. In parallel GA-TS, GA operators are executed for each processor. To prevent solutions of low fitness from appearing in the next generation, strings below the average fitness are saved in the tabu list. If best fitness of the GA is not changed for several generations, TS operators are executed for the upper $10\%$ of the population to enhance the local searching capabilities. With migration operation, best string of each node is transferred to the neighboring node after predetermined iterations are executed. For parallel computing, we developed a PC cluster system consists of 8 PCs. Each PC employs the 2 GHz Pentium IV CPU and is connected with others through ethernet switch based fast ethernet. To show the validity of the proposed method, proposed algorithm has been tested with a practical distribution system in Korea. From the simulation results, we can find that the proposed algorithm is efficient for the distribution system service restoration in terms of the solution quality, speedup, efficiency and computation time.