• Title/Summary/Keyword: fault area

Search Result 802, Processing Time 0.029 seconds

Engineering Geological Geotechnical Characteristics of Newly Constructed Road between the Yangsan Fault and the Dongrae Fault (양산단층과 동래단층 사이를 통과하는 지방도의 지질공학적 특성 연구)

  • 이병주;선우춘
    • The Journal of Engineering Geology
    • /
    • v.13 no.2
    • /
    • pp.193-205
    • /
    • 2003
  • Fine grained granite, porphyritic granite and biotite granite together with intruded and extruded andesitic rocks are distributed in the study area which is bounded by the Yangsan and Dongrae faults. A new domestic road is being constructed along the area between the two major faults. The NNE trending Bupki fault and NE trending Myungkog fault are also developed within the area cross the road. The sheeting joints with dips of less than 30 degrees are only developed in the area of granite outcrop. High angle joints can be divided into 3 sets, such as, NE trending, NW trending and nearly EW trending joints. The joint space is mostly more than 20cm and the joint compressive strength is more than 100 MPa. These data show that even though the study area is situated between large faults, the ground condition is good because the damage zone of the Yangsan and Dongrae faults is relatively narrow.

Bedrock Depth Variations and Their Applications to identify Blind Faults in the Pohang area using the Horizontal-to-Vertical Spectral Ratio (HVSR) (포항지역 HVSR에 의한 기반암 심도와 단층 식별 연구)

  • Kang, Su Young;Kim, Kwang-Hee
    • Journal of the Korean earth science society
    • /
    • v.43 no.1
    • /
    • pp.188-198
    • /
    • 2022
  • Some deep faults do not reach the ground surface and are seldom recognized. Gokgang Fault area in the east of the Heunghae area of the Pohang basin has been selected to confirm the feasibility of the Horizontal-to-Vertical Spectral Ratio (HVSR) approach to identify blind faults. Densely spaced microtremor data have been acquired along two lines in the study area and processed to obtain resonance frequencies. An empirical relationship between the resonance frequency and the bedrock depth was proposed using borehole data available in the study area. Resonance frequencies along two lines were then converted to bedrock depths. The resulting depth profiles show significant lateral variations in the bedrock depth. As expected, considerable variation in the resonance frequency is observed near the Gokgang fault. The depth profiles also present additional significant variations in the resonance frequencies and the bedrock depths. The feature is presumably related to a blind fault that is previously unknown. Therefore, this case study confirms the feasibility of the HVSR technique to identify faults otherwise not recognized on the surface.

Electrical Resistivity Survey in the Eon-Yang Fault Area, Southeastern Korean Peninsula (경상분지(慶尙盆地) 언양단층(彦陽斷層) 지역(地域)에 대(對)한 전기비저항(電氣比抵抗) 탐사연구(探査硏究))

  • Kim, In-Soo;Kim, Jong-Yeol
    • Economic and Environmental Geology
    • /
    • v.16 no.1
    • /
    • pp.11-18
    • /
    • 1983
  • Gyeongsang Basin in the southeastern part of the Korean peninsular is characterized by many fault systems. To decipher the geotectonical evolution of the Korean peninsular and marginal basins in her adjacent areas it is prerequisite to understand the spatial distribution pattern and mutual relationships of these fault systems. Because of difficulties in finding any criterion to recognize the faults in field, their extension and mutual relationships in ages are not very clear yet. As an attempt to find geophysical criteria to recognize the fault, geoelectrical resistivity survey was carried out in this study. With the Wenner configuration four resistivity soundings and twenty seven resistivity profilings were done. The electrode distance used was up to 50m. From the results of the resistivity soundings and boring data of earlier groundwater investigations the depth of alluvial and weathered zone was established to be at most 20m in the study area. In the resistivity profiling low resistivity anomaly zones are detected on every traverse, which are interpreted as caused by fractures, fault clays and mylonites in the fault zone. The width of the fault zone amounts to 0.3-1km. By correlating and connecting the negative anomaly zones from traverse to traverse one can determine the trend of th of the faultzone and therefore that of fault itself. The recognized fault trend in this way was $N15^{\circ}-20^{\circ}E$ and this coincides with the direction of the inferred fault line from earlier geological surface mapping. With the help of this characteristical negative anomaly the existance of another $N80^{\circ}W$ trending fault was estabished. This study has shown that geoelectrical resistivity survey can be applied successfully to the problem of tracing fault line insofar as a fault zone has been developed along fault line.

  • PDF

Analisys about the Earth Fault Characteristics in the Wireless Power Transmission System of the Electric Vehicle (무선충전 전기자동차 전력공급장치에서의 지락사고 특성 분석)

  • Jung, Jin-Soo;Han, Woon-Ki;Park, Chan-Um;Song, Young-Sang;Lim, Hyun-Sung;Cho, Min-Ho;Lyu, Ji-Yun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.13-17
    • /
    • 2014
  • In this paper, the risk of electric shock is analyzed through analysis for characterization of potential distribution analysis and ground fault current analysis near the area where there are occurred a ground fault at electric vehicle wireless charging system using 20kHz. Studies for electric vehicle wireless charging system are in the works for development of efficiency increase, pickup shape design and communication module as a fundamental research step. But the research related to electrical safety and is still scarce state so that more studies are necessary to commercialize. As a result of analysis, it is verified that induced voltage is arisen more up to 45V near the a area of accident during ground fault and fault current has been maintained continuously without clearing fault condition by operating characteristics for circuit breaker and inverter.

A Composite Fault-plane Solution of Microearthquakes in the Yangsan Fault Area during 1996 (1996년 양산단층 일대의 미소지진을 이용한 복합단층면해)

  • Lee, Gi Hwa;Jeong, Tae Ung
    • Journal of the Korean Geophysical Society
    • /
    • v.2 no.4
    • /
    • pp.235-240
    • /
    • 1999
  • From the seismic network data of the Korea Institute of Geology, Mining & Materials during 1995-1996, we derived a composite fault-plane solution of the microearthquakes occurred in the Yangsan fault area. The composite fault-plane solution of nine events shows the orientation of fault 15 ± 3°in strike, 60 ± 8°in dip and 140°in rake or 128 ± 3°in strike, 56 ± 8°in dip and 37°in rake. The compressional axis of the stress field trends ENE to WSW, and this field suggests strike-slip motion with thrust component. The result is consistent with the 1996 Yeong-weol event and the stress field in and around the Korean Peninsula, previously reported.

  • PDF

A fault diagnosis method using an artificial neural network (인공 신경망을 이용한 공정고장 진단방법)

  • 이상규;박선원
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.339-343
    • /
    • 1990
  • This paper describes a neural-network-based methodology for providing a potential solution in the area of process fault diagnosis. The existing neural network for fault diagnosis learn fault node by using pairs of single-symptom-single-cause only. But in real plants, the effect of a fault propagates continuously from it's origin; different sensor values reflect this. In this paper, we suggest a new method which can handle the effect of symptom propagation. The proposed method can find the exact origin of the fault of which the symptom is propagated continuously with time.

  • PDF

A Study on Digital Fault Locator for Transmission Line (송전선로용 디지털 고장점 표정장치에 관한 연구)

  • Lee, Kyung-Min;Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.4
    • /
    • pp.291-296
    • /
    • 2015
  • Transmission line is exposed to a large area, and then faults are likely to occur than the other component of power system. When a fault occurs on a transmission line, fault locator helps fast recovery of power supply on power system. This paper deals with the design of a digital fault locator for improvement accuracy of the fault distance estimation and a fault occurrence position for transmission line. The algorithm of a fault locator uses a DC offset removal filter and DFT filter. The algorithm utilizes a fault data of GPS time synchronized. The computed fault information is transmitted to the other side substation through communication. The digital fault locator includes MPU module, ADPU module, SIU module, and a power module. The MMI firmware and software of the fault locator was implemented.

Identification of the Singal Fault Zone in the Kiheung Reservoir Area by Geotechnical Investigations (기흥저수지 지역의 지반조사를 통한 신갈단층대 확인)

  • Gwon, Sun-Dal;Kim, Sun-Kon;Lee, Soung-Han;Park, Kwon-Gyu
    • Economic and Environmental Geology
    • /
    • v.45 no.3
    • /
    • pp.295-306
    • /
    • 2012
  • In this study, the Singal fault zone in the Gyeonggi massif is identified in the Kiheung area. Geotechnical investigations were carried out to locate and characterize of the Singal fault zone in the Kiheung reservoir area. The N-S striking Shingal fault is known to be a Riedel-type strike-slip fault within the Choogaryung rift. Along the fault zone, 62 bore holes were drilled and electrical resistivity survey of about 11km, and vibroseis seismic refraction and reflection survey of about 500m were done. From the result of investigations, it is found that the fault zone, consisting mainly of gouge and breccia, has maximum width of 300 meters with anastomosing geometry of secondary fractures developed subparallel to the fault zone. We interpret these geometric features to be the result of structural development of flower-structure type at the restraining band of strike-slip fault. However, there are uncertainties of this interpretation because there are virtually no outcrops in the area. Further investigation to understand geometric features and linkage style of the fault zone.

Deep structure of Ulsan fault by electric and EM surveys in ipsil area, South of Kyeongju (전기, 전자탐사에 의한 경주남부 (입실지역)의 울산 단층 심부구조)

  • 손호응
    • Economic and Environmental Geology
    • /
    • v.32 no.2
    • /
    • pp.161-167
    • /
    • 1999
  • Electric and electromagnetic surveys were conducted to investigate the deep structure of the Ulsan fault in Ipsil area, south of Kyeongju. On this study, especially high-frequency magnetotelluric method of electromagnetic survey in the frequency range of 10~100,000 Hz was mainly employed to study the deep subsurface configuration. High-frequency MT survey was performed at 70 points of spacing 30~50 m, making 3.8 km survey line. As a survey result, a 2-km-depth 2-D cross-section was achieved. It shows vertical and horizontal subsurface variations of resistivity values. Near-surface layer having low resistivity value becomes thicker eastward up to 800m. There is a steep low resistivity zone in the west side of survey line, and there exists two low resistivity zones dipping west in the east side of survey line. Two low resistivity zones are interpreted to be related to major movement pattern of the Ulsan fault. This suggests that major fault lines are developed on both peripheral sides of the broad fault zone.

  • PDF

Reactivated Timings of the Yangsan Fault in the Yeonghae area based on the Mineralogical Characteristics of Fault Clays (단층암 점토광물 특성에 기초한 영해지역 양산단층의 단층활동연대 결정)

  • Hong, Seongsik;Sim, Ho;Choi, Sung-Ja;Song, Yungoo
    • Economic and Environmental Geology
    • /
    • v.53 no.6
    • /
    • pp.645-654
    • /
    • 2020
  • We present the K-Ar age dating results of <0.1㎛ fraction of the selected fault rocks from the Yangsan fault in the Yeonghae area. Based on the mineralogical characterization, the <0.1㎛ fractions were mostly composed of 1Md illite polytype, or I-S interstratified mineral, which should be formed by fault activation. Therefore, we determined the timings of fault activation events by analyzing K-Ar age-dating for the <0.1㎛ fractions. Accordingly, the activation timings of Yangsan Fault in the Yeonghae area were determined as 45.5±1.1 Ma, 50.9±1.2 Ma, 58.2±1.3 Ma, 60.8±1.4 Ma, 65.3±1.6 Ma, 66.8±1.5 Ma, 67.1±1.5 Ma, and 75.1±1.7 Ma. These results indicate that at least 5-times of major fault events occurred in the Yangsan fault from late Mesozoic to Cenozoic Era. In the outcrop, age dating results tend to be younger age from the location of the oldest sample(75.1±1.7 Ma) toward to the both sides. From the results, it suggests that the fault activation extends from the location of oldest age saple to both sides. This geochronological research of the multiple fault activation ages for the Yangsan Fault will provide crucial information for establishing the tectonic evolution model in the southeastern part of the Korean Peninsula.