• Title/Summary/Keyword: fatigue cycles

Search Result 575, Processing Time 0.025 seconds

Electrical Characteristics of PZT Ferroelectric Thin Films (PZT 강유전 박막의 전기적 특성)

  • Kim, Hyun-Gwon;Paik, Dong-Soo;Choi, Hyung-Wook;Kim, Jun-Han;Park, Chang-Yup
    • Proceedings of the KIEE Conference
    • /
    • 1993.11a
    • /
    • pp.225-227
    • /
    • 1993
  • Pb(Zr, Ti)$O_3$ ferroelectric thin layers were deposited onto Pt/$SiO_2$/Si substrates by Sol-Gel processing and annealed by RTA at $600^{\circ}C$ for $20{\sim}30\;sec$. microstructure of the films was examined by XRD and SEM analysis. Electrical properties of PZT thin films with different Zr/Ti ratio yield $P_r$ ranging $10{\sim}21{\mu}C/cm^2$, $E_c$, ranging $37.5{\sim}137.5\;kV/cm$, switching times faster than 180nsec, and leakage current about $20{\mu}A/cm^2$. The film was endured about $10^{10}$ fatigue cycles.

  • PDF

Thermo-mechanical reliability evaluation of flip chip package using a accelerated test (가속화 시험을 통한 플립칩 패키지의 열적 기계적 특성 평가)

  • Kim Dae-Gon;Ha Sang-Su;Kim Jong-Ung;Sin Yeong-Ui;Jeong Seung-Bu
    • Proceedings of the KWS Conference
    • /
    • 2006.05a
    • /
    • pp.21-23
    • /
    • 2006
  • The microstructural investigation and thermo-mechanical reliability evaluation of the Sn-3.0Ag-0.5Cu solder bumped flip chip package were carried out during the thermal shock test of the package. In the initial reaction, the reaction product between the solder and Cu mini bump of chip side was Cu6Sn5 layer, while the two phases which were (Cu,Ni)6Sn5 and (Ni,Cu)3Sn4 were formed between the solder and Ni-P layer of the package side. The cracks were occurred at the corner solder joints after the thermal shocks of 400 cycles. The primary failure mechanism of the solder joints in this type of package was confirmed to be thermally activated solder fatigue failure.

  • PDF

The Influence of Repeated Loading Cycles on Strength Ratio of Carbon/Epoxy Composite Laminates (Carbon/Epoxy 복합재료 적층판의 반복하중에 따른 강도계수의 변화에 대한 연구)

  • Kim, Doo-Hwan;Kim, Young-Feel
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.3
    • /
    • pp.19-24
    • /
    • 2009
  • Currently the technique of composite material field is developed day by day. The many kinds industrial facility and life articles are coming to make with the composite material. But still the engineering works field the building and the bridge uses the material which is old era and is making. To here there is a various problem but the biggest problem the theory of the composite material is complicated too and means that the application is been delayed about constructive structure. When the composite material is used widely from constructive field, too with difficult theory in technical expert and easily with the research for the experiment data accumulation is necessary. The tensile and fatigue test of the carbon/epoxy which is a high-class composite material led from the present paper consequently and the change of the intensity coefficient which follows in repeated load researched.

A Study on Stress and Vibration Evaluations and Application of Piping System in Petrochemical Plant (석유화학 플랜트 배관계의 응력 및 진동 평가와 적용에 관한 연구)

  • 민선규;최명진;장승호
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.3
    • /
    • pp.110-116
    • /
    • 2002
  • Here are shown on stress and vibration evaluations and application of piping system in petrochemical plant with and actual example. While stress evaluation by thermal growth has no argument on the calculated results, vibrational evaluations have some different results in accordance with the evaluation methods. In case of the static stress evaluation the ASME B3l.3 code defines 7000 cycles of fatigue lift: in operating the piping system with a design condition. However, the method of vibrational evaluation on piping systems in petrochemical plants has not been established clearly, yet. In this stuffy, it is purposed to present the requirement of a vibrational evaluation method for petrochemical plant piping system, with an actual application.

A Study on Electrical Properties of PZT Thin Films Deposited on the Glass Substrates (유리기판 위에 증착한 PZT 박막의 전기적 특성에 관한 연구)

  • Jeong, Kyu-Won;Ju, Pil-Yeon;Park, Young;Yi, Jun-Sin;Song, Joon-Tae
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.1
    • /
    • pp.24-29
    • /
    • 2001
  • PZT thin films(4000A) have prepared onto 1737 corning glass and ITO coated glass substrates with a RF magnetron sputtering system using Pb_{1.05}(Zr_{0.52},Ti_{0.48})O_3$ceramic target, Electrical properties of PZT thin film deposited after ITO coated glass were P${\gamma}$ was decreased by 25% after 109cycles, respectively. With the RTA treatment duration and temperature increased, the crystallization of PZT thin films were enhanced, however, the leakage current density became higher. The leakage current mechanism was found to be space charge conduction by the defects and oxygen vacancies existing in PZT and PZT/bottom electrode interfaces.

  • PDF

Effects of near-fault records characteristics on seismic performance of eccentrically braced frames

  • Eskandari, Reyhaneh;Vafaei, Davoud
    • Structural Engineering and Mechanics
    • /
    • v.56 no.5
    • /
    • pp.855-870
    • /
    • 2015
  • In this paper the effects of fling-step and forward-directivity on the seismic performance of steel eccentrically braced frames (EBFs) are addressed. Four EBFs with various numbers of stories (4-, 8-, 12- and 15-story) were designed for an area with high seismic hazard. Fourteen near-fault ground motions including seven with forward-directivity and seven with fling-step effects are selected to carry out nonlinear time history (NTH) analyses of the frames. Furthermore, seven more far-field records were selected for comparison. Findings from the study reveal that the median maximum links rotation of the frames subjected to three set of ground motions are in acceptable range and the links completely satisfy the requirement stated in FEMA 356 for LS performance level. The arrival of the velocity pulse in a near-fault record causes few significant plastic deformations, while many reversed inelastic cycles result in low-cycle fatigue damage in far-fault records. Near-fault records in some cases are more destructive and the results of these records are so dispersed, especially the records having fling-step effects.

Optimum design of stiffened plates for static or dynamic loadings using different ribs

  • Virag, Zoltan;Jarmai, Karoly
    • Structural Engineering and Mechanics
    • /
    • v.74 no.2
    • /
    • pp.255-266
    • /
    • 2020
  • The main requirements of modern welded metal structures are the load-carrying capacity (safety), fitness for production, and economy. The primary objective of attaching longitudinal stiffeners is to improve the buckling strength of relatively thin compression panels. This paper gives several comparisons for stiffened plates with different loadings (static, dynamic), different shape of stiffeners (flat, L-shape, trapezoidal), different steel grades, and different welding technologies (SMAW, GMAW, SAW), different costs to show the necessity of a combination of design, fabrication and economic aspects. Safety and fitness for production are guaranteed by fulfilling the design and fabrication constraints. The economy is achieved by minimizing the cost function. It is shown that the optimum sizes depend on the welding technology, the material yield stress, the profile of the stiffeners, the load cycles and the place of the production.

Experimental Study on Bond Stress-Slip Behavior of Reinforced Concrete Member Under Repeated Loading Considering Steel Corrosion (반복하중 하에서 철근부식을 고려한 철근콘크리트 부재의 부착응력-슬립 거동에 관한 실험적 연구)

  • Kim, Chul-Min;Kim, Jee-Sang;Park, Jong-Bum;Chang, Sung-Pil
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.545-548
    • /
    • 2006
  • This study includes the experimental investigation on the fatigue-bond behavior with respect to the various rates of steel corrosion. Major criteria of test variables are the rates of steel corrosion by chloride ion and the ratio of the applied stress to the bond failure stress. According to the test results, the slip versus number of load cycles relation was found to be approximately linear in double logarithmic scale, not only without steel corrosion but also with steel corrosion. This research will be helpful for the realistic durability design and condition assessment of reinforced concrete structures.

  • PDF

Evaluation of Replace period and Useful lifetime of the wire ropes for the Passenger's Elevator (승객용 엘리베이터 와이어로프의 유효수명 및 교체시기 평가)

  • Son, Doo-Ik;Park, Jae-Suk;Oh, Hwan-Seop
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.4
    • /
    • pp.35-38
    • /
    • 2003
  • The wire rope, one of the component of the elevator, is extremely important for the sage operation of the elevator. That is why the wire rope is replaced at a specific interval regradless of the operating conditions or the degree of damage to prevent the breakage of the wire rope. This is the waste of resources, causing economic and environmental loss. This paper has surveyed and analyzed and analyzed the status of replacing wire-rope by buildings that use elevators, in order to compare the replacement cycles of the wire rope under each operating conditions.

Preparation of ferroelectric SrBi2Ta2O9 thin films deposited by multi-target sputtering

  • Hoon, Yang-Cheol;Gil, Yoon-Soon
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.2 no.2
    • /
    • pp.92-96
    • /
    • 1998
  • Ferroelectric Bi-layered oxides SrBi2Ta2O9 (SBT) thin films have been deposited on Pt/Ti/SiO2/Si substrates using multi-target sputtering. Structure, composition, and electrical properties have been investigated on films. The SBT films were deposited with the various bismuth sputtering powers. The SBT films deposited with the bismuth sputtering power of 20 W have the most dense microstructure and the remanent polarization (Pr) of 9.2 ${\mu}$C/cm and the coercive field (Ec) of 43.8 kV/cm at an applied voltage of 5V. The SBT films deposited with the bismuth sputtering power of 20W showed a fatigue-free characteristics up to 1.0${\times}$1010 cycles under 5V bipolar pulse and a leakage current density of 2.0${\times}$10-8 A/$\textrm{cm}^2$ at 200 kV/cm.

  • PDF