• 제목/요약/키워드: fast response

검색결과 1,786건 처리시간 0.035초

Study on the pre-tilt level and uniformity of low rotational viscosity LC for fast response time

  • Lee, D.J.;Hwang, J.I.;Ko, T.W.;Choi, H.C.;Lee, S.W.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.457-459
    • /
    • 2005
  • Low viscosity LCs have been developed for fast response time improvement of the TFT-LCD Monitors based on TN mode. This low viscosity characteristic s cause the pretilt angle to be changed and the uniformity to degrade. We have studied on the pretilt angle effect by the various components used for low viscosity LCs. We prepared the panels by using these various components and measured pretilt angle for this research. As a result of this research, we have found out that each low viscosity component has the different pretilt angle level and uniformity. For good display quality, it is important to keep the stable pretilt angle. The low viscosity LCs with this stable pretilt angle make it possible to prepare the high performance TFT-LCD Monitor with both fast response time characteristics and good display quality

  • PDF

포트 마스킹과 흡기 밸브 타이밍이 실린더 내부의 싸이클별 HC와 NOx 생성에 미치는 영향 (Cycle-by-Cycle In-cylinder HC & NOx Formation Characteristics with Port Masking in CVVT Engine)

  • 전우주;최관희;명차리;박심수;이경환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.3108-3113
    • /
    • 2008
  • This paper investigated the behaviors of combustion characteristics at part load condition with various intake charge motions induced by the port masking schemes in the CVVT (Continuously Variable valve Timing) engine. Time resolved in-cylinder and exhaust emissions were measured by the fast response HC and NOx analyzers to examine their formation mechanisms and behavior characteristics. As a result, in-cylinder HC decreased with the advanced intake valve timings but HC at the exhaust port increased due to the worse combustion stabilities. However HC reduction could be achieved by the application of the port maskings with a enhancement of the engine stability. NOx also decreased with early intake timings by internal EGR but increased with the charge motion controls which enhance the combustion behavior.

  • PDF

진화전략을 이용한 Manabe 표준형에 관한 연구 (A Study on the Manabe Standard Form Using the Evolutionary Strategy)

  • 강환일;정요원
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제50권2호
    • /
    • pp.65-71
    • /
    • 2001
  • The step response of the Manabe standard form[2] has little overshoot and show almost same waveforms regardless of the order of the characteristic polynomials. In some situations it is difficult to control the rise time and settling time simultaneously of the step response of the Manabe standard form To control its rise time and settling time efficiently, We develop the Manabe standard form: We try to find out the SRFS(Slow Rise time & Fast Setting time) form which has the slower rise time and faster settling time than those fo the Manabe standard form. We also consider the other three forms: FRSS(Fast Rise time & Slow Settling time), SRFS(Slow Rise time & Fast Settling time) and SRSS(Slow Rise time & Slow Settling time) forms. In this paper, by using the evolutionary strategy, we obtain all the coefficient of the four forms we mention above. Finally, we design a controller for a given plant so that the overall system has the performance that the rise time is faster, the settling time is faster than those of the Manabe standard form.

  • PDF

MEASUREMENT OF $CO_2$ CONCENTRATION AND A/F RATIO USING FAST NDIR ANALYZER ON TRANSIENT CONDITION OF SI ENGINE

  • Lee, S.W.;Kim, W.S.;Lee, J.H.;Park, J.I.;Yoo, J.S.
    • International Journal of Automotive Technology
    • /
    • 제7권4호
    • /
    • pp.385-390
    • /
    • 2006
  • A fast response $CO_2$ analyzer has been developed to study transient characteristics on an SI engine. The analyzer has the delay time of 4.5 ms and time constant of 2.8 ms, which is fast enough to measure $CO_2$ concentration on a transient condition. Wide range of A/F(Air/Fuel) ratio can be estimated using the analyzer with an additional switch type oxygen sensor. The results of measurement of $CO_2$ concentration and A/F ratio on a transient condition including rapid acceleration/deceleration and EGR(Ehxaust Gas Recirculation) on/off are presented and compared with a commercial exhaust gas analyzer and UEGO(Universial Exhaust Gas Oxyzen) sensor.

HTPE 둔감 추진기관의 급속가열 시험 및 평가 (Fast Cook-Off Test and Evaluation for HTPE IM Rocket Motor)

  • 이도형;김창기;연정모;정정용;유지창
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 제33회 추계학술대회논문집
    • /
    • pp.167-170
    • /
    • 2009
  • 본 연구에서는 추진기관 급속가열시험을 실시하여 그 특성을 분석 평가 하였다. 연소관은 카본 에폭시 복합재를 사용하였고 추진제는 둔감 특성을 향상 시켜주기 위해 HTPE 추진제를 사용하였다. 반응 형태를 정량적으로 판단하기 위해 음압 및 열유속 센서를 사용하였다. 급속가열 시험한 HTPE 모타들의 반응형태는 Type V 인 연소반응을 나타내었다.

  • PDF

Fast Transient Buck Converter Using a Hysteresis PWM Controller

  • Liu, Yong-Xiao;Zhao, Jin-Bin;Qu, Ke-Qing
    • Journal of Power Electronics
    • /
    • 제13권6호
    • /
    • pp.991-999
    • /
    • 2013
  • In this paper, a fast transient buck converter using hysteresis PWM control is presented. The proposed control method is based on hysteresis control of the capacitor C voltage. This offers a faster transient response to meet the challenges of the power supply requirements for fast dynamic input and load changes. It also provides better stability and solves the compensation problem of the error amplifier in conversional voltage PWM control. Finally, the steady-state and dynamic operation of the proposed control method are analyzed and verified by simulation and experimental results.

Fast Single-Phase All Digital Phase-Locked Loop for Grid Synchronization under Distorted Grid Conditions

  • Zhang, Peiyong;Fang, Haixia;Li, Yike;Feng, Chenhui
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1523-1535
    • /
    • 2018
  • High-performance Phase-Locked Loops (PLLs) are critical for grid synchronization in grid-tied power electronic applications. In this paper, a new single-phase All Digital Phase-Locked Loop (ADPLL) is proposed. It features fast transient response and good robustness under distorted grid conditions. It is designed for Field Programmable Gate Array (FPGA) implementation. As a result, a high sampling frequency of 1MHz can be obtained. In addition, a new OSG is adopted to track the power frequency, improve the harmonic rejection and remove the dc offset. Unlike previous methods, it avoids extra feedback loop, which results in an enlarged system bandwidth, enhanced stability and improved dynamic performance. In this case, a new parameter optimization method with consideration of loop delay is employed to achieve a fast dynamic response and guarantee accuracy. The Phase Detector (PD) and Voltage Controlled Oscillator (VCO) are realized by a Coordinate Rotation Digital Computer (CORDIC) algorithm and a Direct Digital Synthesis (DDS) block, respectively. The whole PLL system is finally produced on a FPGA. A theoretical analysis and experiments under various distorted grid conditions, including voltage sag, phase jump, frequency step, harmonics distortion, dc offset and combined disturbances, are also presented to verify the fast dynamic response and good robustness of the ADPLL.

Direct Torque Control of a Synchronous Reluctance Motor Using the Finite Element Method

  • Lee Sang-Don
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권2호
    • /
    • pp.173-180
    • /
    • 2005
  • The construction of a Synchronous Reluctance Motor (SynRM) is simple and also highly economical because a stator from the existing AC motor can be used. Since the synchronous inductance in the Synchronous Reluctance Motor is an element that is proportional to torque, its exact value must be experimentally or analytically found for accurate control and performance development of the motor. In this paper, direct torque control (DTC) simulation is carried out to maximize the torque of the Synchronous Reluctance Motor and the fast response characteristics with the inductance value by the Finite Element Method (FEM). The response characteristics are compared through the proposed direct torque control and torque response characteristics that are based on the existing PI Control in order to confirm the fast response features. To test the performance of the direct torque controller, the torque response is analyzed with variable speed and load condition.

In-plane Switching Liquid Crystal Cell with a Mixed Bent Electrode Structure for Fast Response Time

  • Ko, Tae-Woon;Kim, Jae-Chang;Lee, Joun-Ho;Choi, Hyun-Chul;Ji, Seung-Hoon;Choi, Jung-Min;Lee, Chul-Hun;Lee, Gi-Dong
    • Journal of Information Display
    • /
    • 제9권3호
    • /
    • pp.12-15
    • /
    • 2008
  • A bent electrode structure is proposed in the super in-plane switching (S-IPS) liquid crystal (LC), as it can reduce the response time without loss of transmittance in the bright state. The electrode angle in each position of the bent electrode was optimized to simultaneously achieve high transmittance and fast response time. The electro-optical characteristics of the proposed LC cell structure were experimentally compared with those of the conventional cell. It was observed that the response time became over 8% shorter without loss of transmittance when the proposed bent structure was applied.

Two Approaches in LCDs With Fast Electro-optic Response: PSV-mode FLCDs and FM-TN-LCDs

  • Kobayashi, Shunsuke
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.911-914
    • /
    • 2004
  • This paper discusses on new two LCD technologies featured by the fast electro-optic response:one is polymer-stabilized FLCDs that exhibit V-shaped electro-optic (EO) switching called PSV-mode FLCDs with response time of 400 ${\mu}$ s; and the other is TN-mode LCDs that exhibit a frequency modulation response (called PM-TN LCDs)and a peculiar sensitivity to the high frequency component of driving voltage waveforms resulting in a short decay time constant of 5ms and an enhancement in the over-driving that yields short response time of 1ms between two gray levels.

  • PDF