• Title/Summary/Keyword: false negative

Search Result 513, Processing Time 0.022 seconds

Usefulness of $^{18}F-FDG$ PET/CT in the Diagnosis of Cervical Lymph Node Metastases of Head and Neck Cancer (두경부암 경부 림프절 전이의 진단에서 $^{18}F-FDG-PET/CT$의 유용성)

  • Kim, Chung-Ho;Kim, Sung-Hoon;O, Joo-Hyun;Yoo, Ie-Ryung;Chung, Yong-An;Park, Young-Ha;Sohn, Hyung-Sun;Lee, Sung-Young;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.5
    • /
    • pp.269-277
    • /
    • 2005
  • Purpose: This study evaluated the diagnostic value of $^{18}F-FDG$ PET/CT in detecting cervical lymph node metastases in head and neck cancer patients. Materials & Methods: The patients were divided into two groups, 46 patients underwent PET/CT scan for initial staging before surgery, and 20 patients for restaging of recurrence after primary treatment. Increased FDG uptakes in cervical lymph nodes were evaluated retrospectively and correlated with the histopathologic results. Results: In the initial staging group, 21 lymph nodes were detected by PET/CT in 15 patients. 20 lymph nodes were confirmed as metastases with a mean peak SUV of 5.84, and the remaining one lymph node was an inflammatory lesion, with a peak SUV of 2.75. Seven metastatic lymph nodes were reported only by histopatholoay. The sensitivity, specificity, positive predictive value and negative predictive value were 74.0%, 99.6%, 95.2% and 97.3%, respectively. In the recurrence group, 11 lymph nodes were detected in 9 patients, and 8 nodes were true positive, with a mean peak SUV of 5.65. The other three were inflammatous lymph nodes, and the peak SUVs were 2.16, 2.94 and 3.53. One false negative lymph node was reported. The sensitivity, specificity, positive predictive value and negative predictive value were 88.8%, 97.7%, 72.7% and 92.9%, respectively. Conclusions: FDG-PET/CT shows higher positive predictive value in the initial staging group, and better sensitivity in the recurrence group. Therefore PET/CT could be useful for both initial staging and restaging of recurrent cervical lymph node metastases.

How Reliable is Sputum PCR Test in the Diagnosis of Pulmonary Tuberculosis When Sputum Smear is Negative? (객담 결핵균 도말검사가 음성일때 중합효소연쇄반응검사와 진단적 신뢰도에 관한 연구)

  • Baek, Seung-Hoon;Lee, Jae-Myung;Kang, Min-Jong;Son, Jee-Woong;Lee, Seung-Joon;Kim, Dong-Gyu;Lee, Myung-Goo;Hyun, In-Gyu;Jung, Ki-Suck;Lee, Kyung-Wha;Joe, Hyun-Chan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.2
    • /
    • pp.222-228
    • /
    • 2001
  • Backgrounds : Recent technological developments have introduced a new method to identifying M. tuberculosis complex DNA in clinical samples directly. The direct amplification test (DAT) is approved for identifying M. tuberculosis complex in respiratory specimens that are smear-positive for acid-fast bacilli (AFB). When there is a discrepancy between the AFB smear and DAT, no information on their clinical utility is currently available. In this study, the diagnostic reliability of DAT was investigated in suspected pulmonary tuberculosis patients whose sputum AFB smear was negative. Methods : From June 1, 1998 through May 30, 1999, 909 patients with presumed active pulmonary tuberculosis were enrolled. A sputum AFB stain, culture, DAT and/or biopsy were performed. Using the criteria of clinical tuberculosis or confirmed tuberculosis, the positive predictive value of DAT in diagnosing pulmonary tuberculosis was investigated. Results : The positive predictive value of DAT was 82.1% by the clinically active tuberculosis criteria. However, it decreased to 61.5% when diagnosis was restricted to only to culture positive or biopsy proven cases. The false positive rate of DAT was 18.0%. Conclusion : The DAT is a valuable diagnostic method in suspected patients whose sputum AFB is was negative.

  • PDF

The Materials on Korean Folk Religions in the Encyclopedic Literatures of Late Joseon Dynasty (조선후기 유서류(類書類)에 나타난 민속종교 자료)

  • Suh, Young-Dae
    • Journal of Korean Historical Folklife
    • /
    • no.33
    • /
    • pp.31-72
    • /
    • 2010
  • At first, I extract materials on folk religion from four encyclopedic literatures of late Chosun dynasty-Lee, Ji-Bong-Ryu-Seol(『芝峯類說』) by Soo-Kwang(李晬光), San-Lim-Kyung-Jae(『山林經濟』) by Hong, Man-Sun(洪萬選), Sung-Ho-Sa-Seol(『星湖僿說』) by Lee-Ik(李瀷), O-Ju-Yeon-Moon-Jang-Jun-San-Go(『五洲衍文長箋散稿』) by Lee, Kyu-Kyung(李圭景), and present these materials by tables. Second, I examined the contents and characters of these materials on folk religion. The conclusions from this research are as follows. ① There are common features and points of difference between these four encyclopedic literatures. One of common features are that all these four are encyclopedic works, but San-Lim-Kyung-Jae is more practical than another three. ② These encyclopedic literatures regard folk religion as a negative culture, because these literatures based on Confucianism. But they did not deny miraculous virtues of folk religion. ③ These encyclopedic literatures give us many informations on gods and spirits of Korean folk religion, i.e. city gods(城隍神)·Yup-Sin(업신)·spirits of disease, god Kim-Bu(金傅大王神)·god Jung-Duk-Yang(鄭得揚)·god of King Kuan-u(關王神)·god Bu-keun(付根神) etc. So I review these gods and spirits referenced in encyclopedic literatures. ④ These encyclopedic literatures show much interest in ghost in common. The reason of interest is that authors of these encyclopedic literatures are all scholars of Sung Confucianism and Sung Confucian was concern about ghost. The Sung Confucianism denied the ghost as personal being whom Korean folk religion regards to a kind of spirits. Instead of beliefs in ghost of folk religion, they insist on the ghost as Ki(氣), a kind of cosmic principle. But these encyclopedic literatures acknowledge some parts of folk religion's beliefs in ghost, because they admit the miraculous virtues of these parts. ⑤ There are many items on divination in these encyclopedic literatures. But they show dual attitude on divinations. The one is negative attitude to divinations on individual destiny and the other one is positive attitude to divinations on agriculture. ⑥ There are also many items on witchcrafts in these encyclopedic literatures. Through these items, I assumed pervasiveness of beliefs on witchcraft at that time. ⑦ Shamans, as religious specialist, are stand on a central position of Korean folk religion. So it is a matter of course that these encyclopedic literatures concerned on Korean shaman. As Confucians, authors of these encyclopedic literatures did not regards shamans as positive one. But they did not deny miraculous virtues of shamans. In spite of these encyclopedic literatures have negative view points to, and include false informations Korean folk religion, I would like to emphasis on importance of these encyclopedic literatures to understand Korean folk religions, especially Korean folk religions of late Yi Dynasty.

The Utility of Chest CT in Staging of Esophageal Cancer (식도암의 병기 결정에 있어 흉부 CT의 유용성)

  • 홍성범;장원채;김윤현;김병표;최용선;오봉석
    • Journal of Chest Surgery
    • /
    • v.37 no.12
    • /
    • pp.992-998
    • /
    • 2004
  • Background: The decision of staging of esophageal cancer have great effect on the resectability of the lesion and estimation of the patient's prognosis. Today, CT is one of the most popular modality for staging of esophageal cancer. However, it has some limitations because of false-positive or false-negative findings on cancer staging. The purpose of this study was to analyze the efficacy of CT in preoperative staging of esophageal cancer. Material and Method: We retrospectively analysed the difference of staging of esophageal cancer between CT and histopathological findings for the 114 patients with histologically proven esophageal cancer who underwent operation at the department of thoracic and cardiovascular surgery, Chonnam national university hospital, between January 1999 and June 2003. We evaluated the efficacy of chest CT in the staging of esophageal cancer compared to postoperative histopathologic findings by calculating sensitivity, specificity, accuracy, and reproducibility of chest CT to detect abnormality. Result: The reproducibilities between chest CT and histopathologic findings were 0.32 (p<0.01) for primary tumor (T), 0.36 (p<0.01) for lymph node invasion (N), and 0.62 (p<0.01) for distant metastasis (M). The reproducibilities between chest CT and histopathologic findings for lymph node invasion (N) and distant metastasis (M) were superior to that of primary tumor (T). The accuracy of primary tumor (T) was 65.8% and 98.2% in group III and IV, which was significantly higher than that of group I and II (78.9% and 62.3%). In general, specificity of chest CT for TNM staging was superior to sensitivity. Conclusion: In conclusion, preoperative CT scanning can provide important information on lymph node invasion and metastasis of lesion than primary tumor invasion.

An Intelligent Intrusion Detection Model Based on Support Vector Machines and the Classification Threshold Optimization for Considering the Asymmetric Error Cost (비대칭 오류비용을 고려한 분류기준값 최적화와 SVM에 기반한 지능형 침입탐지모형)

  • Lee, Hyeon-Uk;Ahn, Hyun-Chul
    • Journal of Intelligence and Information Systems
    • /
    • v.17 no.4
    • /
    • pp.157-173
    • /
    • 2011
  • As the Internet use explodes recently, the malicious attacks and hacking for a system connected to network occur frequently. This means the fatal damage can be caused by these intrusions in the government agency, public office, and company operating various systems. For such reasons, there are growing interests and demand about the intrusion detection systems (IDS)-the security systems for detecting, identifying and responding to unauthorized or abnormal activities appropriately. The intrusion detection models that have been applied in conventional IDS are generally designed by modeling the experts' implicit knowledge on the network intrusions or the hackers' abnormal behaviors. These kinds of intrusion detection models perform well under the normal situations. However, they show poor performance when they meet a new or unknown pattern of the network attacks. For this reason, several recent studies try to adopt various artificial intelligence techniques, which can proactively respond to the unknown threats. Especially, artificial neural networks (ANNs) have popularly been applied in the prior studies because of its superior prediction accuracy. However, ANNs have some intrinsic limitations such as the risk of overfitting, the requirement of the large sample size, and the lack of understanding the prediction process (i.e. black box theory). As a result, the most recent studies on IDS have started to adopt support vector machine (SVM), the classification technique that is more stable and powerful compared to ANNs. SVM is known as a relatively high predictive power and generalization capability. Under this background, this study proposes a novel intelligent intrusion detection model that uses SVM as the classification model in order to improve the predictive ability of IDS. Also, our model is designed to consider the asymmetric error cost by optimizing the classification threshold. Generally, there are two common forms of errors in intrusion detection. The first error type is the False-Positive Error (FPE). In the case of FPE, the wrong judgment on it may result in the unnecessary fixation. The second error type is the False-Negative Error (FNE) that mainly misjudges the malware of the program as normal. Compared to FPE, FNE is more fatal. Thus, when considering total cost of misclassification in IDS, it is more reasonable to assign heavier weights on FNE rather than FPE. Therefore, we designed our proposed intrusion detection model to optimize the classification threshold in order to minimize the total misclassification cost. In this case, conventional SVM cannot be applied because it is designed to generate discrete output (i.e. a class). To resolve this problem, we used the revised SVM technique proposed by Platt(2000), which is able to generate the probability estimate. To validate the practical applicability of our model, we applied it to the real-world dataset for network intrusion detection. The experimental dataset was collected from the IDS sensor of an official institution in Korea from January to June 2010. We collected 15,000 log data in total, and selected 1,000 samples from them by using random sampling method. In addition, the SVM model was compared with the logistic regression (LOGIT), decision trees (DT), and ANN to confirm the superiority of the proposed model. LOGIT and DT was experimented using PASW Statistics v18.0, and ANN was experimented using Neuroshell 4.0. For SVM, LIBSVM v2.90-a freeware for training SVM classifier-was used. Empirical results showed that our proposed model based on SVM outperformed all the other comparative models in detecting network intrusions from the accuracy perspective. They also showed that our model reduced the total misclassification cost compared to the ANN-based intrusion detection model. As a result, it is expected that the intrusion detection model proposed in this paper would not only enhance the performance of IDS, but also lead to better management of FNE.

Establishment of Reference Range of Proinsulin (Proinsulin 참고치 설정에 관한 연구)

  • Nam, Yee Moon;Shin, Yong Hwan;Kim, Ji Young;Seok, Jae Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.76-79
    • /
    • 2013
  • Purpose: It is very important to establish the appropriate reference range in the laboratory for preventing mistakes like false positive or false negative. Because the reference range in the laboratory is standard of patient test results interpretation. Proinsulin is precursor hormone of insulin, and the importance is increasing for diagnosing diabetes or insulinoma. Proinsulin reagent used in our laboratory is produced in the USA, and the reference range provided by manufacturer was adapted to our reference range after the validation test. But, it is generally recommend for the every laboratory to establish the their own reference range. So, we decided to re-evaluate the reference range with our patients' test results. Materials and Methods: Among 737 patients who had been to health promotion center in our hospital between Dec. $8^{th}$ 2011 and Dec. $21^{st}$ 2011, 563 patients are chosen with exception of diabetics patients and patients showing abnormal test results in Fasting Glucose, HbA1c, Insulin, and C-peptide. The 563 test results (275 males and 288 females) were classified with three groups(entire, male, female), and analysis of normal distribution was performed with aid of SPSS(version 19.0). Because Each group didn't show normal distribution, the reference range was set from the lowest limit of 2.5% to the highest limit of 97.5% with Percentile method used in non-normal distribution. Results: When evaluation values are sorted in ascending order, the entire range is 4.5~52.0 pM and 5.3~51.9 pM for male and 4.5~52.0 pM for female. The calculated reference range with percentile method shows 6.7~26.5 pM for entire group, 6.8~26.5 pM for male and 6.7~26.5 pM for female, respectively. Conclusion: The reference range provided by reagent manufacturer is 6.4~9.4 pM and the one established in this study is 6.7~26.5 pM. This difference might be caused by racial characteristics between Western people and Koreans. So an ideal reference range can be gotten with normal population visiting to every hospital. Our hospital has been using the newly re-establishing reference range under consultation with the department of endocrinology since Aug. $1^{st}$ 2012.

  • PDF

Comparison of Ultrasound-guided Suprapubic Aspiration with Urethral Catheterization in Infants (영유아에서 초음파 감시하 치골상부 방광천자와 도뇨관 채뇨의 비교)

  • Lee, Jung-Won;Lee, Seung-Joo
    • Childhood Kidney Diseases
    • /
    • v.11 no.1
    • /
    • pp.59-64
    • /
    • 2007
  • Purpose : Suprapubic aspiration(SPA) has been considered the "gold standard" for obtaining urine in non-toilet trained infants. Ultrasound(US)-guided SPA improves the success rate of the procedure and reduces the complications. However, many physicians perceive SPA as invasive and prefer the use of urethral catheterization (Ucat). We compared the success rate, complications and accuracy of US-guided SPA and Ucat. Methods : 121 infants who visited Ewha Womans University Mokdong Hospital with suspected urinary tract infection(UTI) were investigated. For the first study, the study infants were randomly assigned to either the US-guided SPA(n=32) or Ucat(n=32) groups. The success rate and complications of both procedures were compared. For the second study, US-guided SPA and Ucat were performed simultaneously(n=57). The accuracy of urethral catheterization was subsequently analyzed. The criteria for success was defined as the collection of more than 0.5 mL of urine. UTI was diagnosed by the presence of uropathogens over 105 colony-forming units (CFU)/mL. Results : The overall success rate of the US-guided SPA was 96.9%(71.9% in first attempts, 25.0% in second attempts) which was not significantly different compared to 96.9%(90.6% in first attempts, 6.3% in second attempts) in the Ucat(P>0.05) group. The aspirated urine volume was $7.4{\pm}3.7mL$ in the US-guided SPA group, which was not significantly different to $4.5{\pm}2.6mL$ in the Ucat(P>0.05) group. The accuracy of Ucat in comparison to the US guided SPA was low with sensitivity 59.5%, specificity 86.6%, false-positive rate 13.3% and false-negative rate 40.5%. Conclusion : US-guided SPA should be encouraged as the best method to collect the urine in non-toilet trained infants with UTI.

  • PDF

Usefulness of Blood Pool Half Body in Three Phase Bone Scan in Patients with R/O Reflex Symphathetic Dystrophy Syndrome (반사성교감신경 이영양증후군 환자의 삼상 골 스캔 시 Half Body 혈액 풀 영상의 적용)

  • Lee, Moo-Seok;Lee, Hyo-Yeong;Yun, Jong-Jun;Lee, Hwa-Jin;Song, Hyeon-Seok;Park, Se-Yun;Jeong, Ji-Uk
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.105-110
    • /
    • 2010
  • Purpose: Three phase bone scan was considered sensitive in Patients with Reflex Symphathetic Dystrophy Syndrome (RSDS). Generally, three phase bone scan in the RSDS patients shows increased uptake of one side extremity joint. But three phase bone scan has been performed with flow, blood pool and delayed scan. We performed blood pool half body scan in order to investigate its usefulness. Materials and Methods: From October 2007 to September 2009, three phase bone scan (flow, blood pool, half body blood pool, delayed) was performed after injection of 750 MBq of $^{99m}Tc$-DPD in diagnosed patients with RSDS (M:F=8:7, R:L=9:6). For quantitative analysis, we obtained the count ratios of bilateral hands by drawing a region of interest (ROI) in the three phase images and compared with the count ratios of shoulders in half body blood pool and delayed images. Results: In flow images, right/left ratios were $1.09{\pm}0.53$. In blood pool images, right/left ratios were $1.13{\pm}0.47$ (hand), $1.08{\pm}0.26$ (shoulder). In delayed images, right/left ratios were $1.24{\pm}0.75$ (hand), $1.11{\pm}0.31$ (shoulder). As a result, Log of right/left counts of the others and that of shoulder blood pool image were correlated well with statistical significance (Spearman's R, p<0.005 SPSS for windows ver.12.0). Conclusion: Half body blood pool scan may be helpful in the diagnosis of patients with RSDS. Moreover, Half body blood pool scan reduced false negative and false positive rates. In order to improve agreement on interpretation of RSDS, Blood pool half body scan should be established as common criteria.

  • PDF

The change of validity of blood zinc protoporphyrin test by different cut-off level in lead workers (연취급 근로자들의 혈중 ZPP 농도 선별기준에 따른 정확도의 변화)

  • Kim, Yong-Bae;Ahn, Hyun-Cheol;HwangBo, Young;Lee, Gap-Soo;Lee, Sung-Soo;Ahn, Kyu-Dong;Lee, Byung-Kook
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.4 s.59
    • /
    • pp.741-751
    • /
    • 1997
  • Measurement of blood lead (PbB) and blood zinc protoporphyrin (ZPP) are most common biological indices to identify the individual at risk for excess or the health sequences by lead exposure. Because PbB is known most important and reliable index of lead exposure, PbB is often regarded as a gold standard to detect lead exposure. But in Korea PbB is a secondary test item of detailed health check-up with positive finding of screening test in most occasion. Our lead standard requires all lead workers to take annual heath-check twice a year for investigation of their health effect due to lead exposure. Blood ZPP is one of most important index to detect high lead absorption in lead workers as a screening test. Measurement of blood ZPP is known ,well to correlate with PbB in steady state of exposure in most lead workers and is often used as a primary screening test to detect high lead absorption of lead workers with the advantage of simplicity, easiness, portability and low cost. The current cut-off criteria of blood ZPP for further detailed health check-up is $100{\mu}g/d\ell$ which is supposed to match the level of $40{\mu}g/d\ell$ of PbB according to our standard. Authors tried to investigate the validity of current criteria of cut-off level $(100{\mu}g/d\ell)$ of blood ZPP and possible another better cut-off level of it to detect the lead workers whose PbB level over $40{\mu}g/d\ell$. The subjects in our study were 212 male workers in three small scale storage battery industries. Blood ZPP, PbB and hemoglobin (Hb) were selected as the indices of lead exposure. The results were as follows. 1. The mean of blood ZPP, PbB and Hb in lead workers were $79.5{\pm}46.7{\mu}g/d\ell,\;38.7{\pm}15.1{\mu}g/d\ell,\;and\;14.8{\pm}1.2g/d\ell$, respectively. There were significant differences in blood ZPP, PbB and Hb by industry (P<0.01). 2. The percents of lead workers whose blood ZPP were above $100{\mu}g/d\ell$ in the group of work duration below 1, 1-4, 5-9 and above 10 years were 8.6%, 17.2%, 47.6%, and 50.0%, respectively. The percents of lead workers whose PbB were above $40{\mu}g/d\ell$ in those were 31.4%, 40.4%, 71.4%, and 86.4%, respectively. 3. The percents of lead workers whose PbB were below $40{\mu}g/d\ell$, $40-59{\mu}g/d\ell$ and above $60{\mu}g/d\ell$ were 54.7%, 34.9% and 10.4%, respectively. Those of lead workers whose blood ZPP were below $100{\mu}g/d\ell$, $100-149{\mu}g/d\ell$ and above $150{\mu}g/d\ell$ were 79.2%, 13.7% and 7.1%, respectively. 4. Simple linear regression of PbB on blood ZPP was statistically significant (P<0.01) and as PbB was $40{\mu}g/d\ell$, blood ZPP was $82.1{\mu}g/d\ell$. 5. While the highest sensitivity and specificity of blood ZPP test to detect lead workers with PbB eve. $40{\mu}g/d\ell$ were observed in the cut-off level of $50{\mu}g/d\ell$ and $100{\mu}g/d\ell$ of blood ZPP, respectively, the highest validity (sensitivity+specificity) of blood ZPP to detect lead workers with PbB over $40{\mu}g/d\ell$ was observed in the cut-off level of around $70{\mu}g/d\ell$ of blood ZPP. But even with optimal cut-off level of around $70{\mu}g/d\ell$ of blood ZPP, still 25.0% of false negative and 20.7% false positive lead workers were found. As the result of this study, it was suggested that reconsideration of current blood ZPP cut-off of our lead standard from $100{\mu}g/d\ell$ to somewhat lower level such as around $70{\mu}g/d\ell$ and the inclusion of PbB measurement as a primary screening test for lead workers was highly recommended for the effective prevention of lead workers.

  • PDF

F-18-FDG Whole Body Scan using Gamma Camera equipped with Ultra High Energy Collimator in Cancer Patients: Comparison with FDG Coincidence PET (종양 환자에서 초고에너지(511 keV) 조준기를 이용한 전신 F-18-FDG 평면 영상: Coincidence 감마카메라 단층 촬영 영상과의 비교)

  • Pai, Moon-Sun;Park, Chan-H.;Joh, Chul-Woo;Yoon, Seok-Nam;Yang, Seung-Dae;Lim, Sang-Moo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.65-75
    • /
    • 1999
  • Purpose: The aim of this study is to demonstrate the feasibility of 2-[fluorine-18] fluoro-2-deoxy-D-glucose (F-18-FDG) whole body scan (FDG W/B Scan) using dual-head gamma camera equipped with ultra high energy collimator in patients with various cancers, and compare the results with those of coincidence imaging. Materials and Methods: Phantom studies of planar imaging with ultra high energy and coincidence tomography (FDG CoDe PET) were performed. Fourteen patients with known or suspected malignancy were examined. F-18-FDG whole body scan was performed using dual-head gamma camera with high energy (511 keV) collimators and regional FDG CoDe PET immediately followed it Radiological, clinical follow up and histologic results were correlated with F-18-FDG findings. Results: Planar phantom study showed 13.1 mm spatial resolution at 10 cm with a sensitivity of 2638 cpm/MBq/ml. In coincidence PET, spatial resolution was 7.49 mm and sensitivity was 5351 cpm/MBq/ml. Eight out of 14 patients showed hypermetabolic sites in primary or metastatic tumors in FDG CoDe PET. The lesions showing no hypermetabolic uptake of FDG in both methods were all less than 1 cm except one lesion of 2 cm sized metastatic lymph node. The metastatic lymph nodes of positive FDG uptake were more than 1.5 cm in size or conglomerated lesions of lymph nodes less than 1cm in size. FDG W/B scan showed similar results but had additional false positive and false negative cases. FDG W/B scan could not visualize liver metastasis in one case that showed multiple metastatic sites in FDG CoDe PET. Conclusion: FDG W/B scan with specially designed collimators depicted some cancers and their metastatic sites, although it had a limitation in image quality compared to that of FDG CoDe PET. This study suggests that F-18-FDG positron imaging using dual-head gamma camera is feasible in oncology and helpful if it should be more available by regional distribution of FDG.

  • PDF