• Title/Summary/Keyword: facility safety management

Search Result 706, Processing Time 0.026 seconds

Analysis on Impact Factors of Open-cut Type Excavation Work using Numerical Analysis Method (수치해석기법을 이용한 개착식 지반굴착공사의 영향인자 분석)

  • Seong, Joo-Hyun;Kim, Yong-Soo;Shin, Byoung-Gil
    • Journal of the Korean Geosynthetics Society
    • /
    • v.12 no.3
    • /
    • pp.43-53
    • /
    • 2013
  • In this study, an analysis about the causes of different types of excavation on accidents is required in order to prevent the frequently occurring accidents related to the earth retaining structure and excavation. Also, analysis of influence was performed by using numerical typical soil conditions and construction trend using numerical analysis method. According to the analysis results of 25 accident cases, the main influence factors were found as following: insufficient of soil survey, instability of temporary facility and lack of groundwater treatment, etc. Furthermore, in the numerical analysis result of 22 cases, drainage method was occurred larger settlement than waterproof method in the Inland. In case of applying the earth anchor method, it needs more detailed in the regions, which are discovered soft ground or rock discontinuities. Also, The consolidated clay absolutely needs further consideration of excess hydrostatic pressure.

Clinical Microscopy: Performance, Maintenance and Laser Safety (임상에서의 현미경: 작동, 유지보수 및 레이저 안전)

  • Lee, Tae Bok
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.2
    • /
    • pp.125-133
    • /
    • 2019
  • A microscope is the fundamental research and diagnostic apparatus for clinical investigation of signaling transduction, morphological changes and physiological tracking of cells and intact tissues from patients in the biomedical laboratory science. Proper use, care and maintenance of microscope with comprehensive understanding in mechanism are fully requested for reliable image data and accurate interpretation for diagnosis in the clinical laboratory. The standard operating procedure (SOP) for light microscopes includes performance procedure, brief information of all mechanical parts of microscopes with systematic troubleshooting mechanism depending on the laboratory capacity. Maintenance program encompasses cleaning objective, ocular lenses and inner optics; replacement and calibration of light source; XY sample stage management; point spread function (PSF) measurement for confocal laser scanning microscope (CLSM); quality control (QC) program in fluorescent microscopy; and systematic troubleshooting. Laser safety is one of the concern for medical technologists engaged in CLSM laboratory. Laser safety guideline based on the laser classification and risk level, and advisory lab wear for CLSM users are also expatiated in this overview. Since acquired image data presents a wide range of information at the moment of acquisition, well-maintained microscopes with proper microscopic maintenance program are impulsive for its interpretation and diagnosis in the clinical laboratory.

Analysis of the Legal Blind Sectors of the Large-Scale Offshore Wind Farms of Korea and Proposal to Improve Safety Management (대규모 해상풍력발전단지의 안전관리를 위한 법적 사각지대 분석 및 개선 제안)

  • Inchul Kim;Dong Nam
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.2
    • /
    • pp.127-138
    • /
    • 2023
  • A variety of decarbonized energy sources are being developed globally to realize carbon neutrality (Net Zero) by 2050 as a measure to address the global climate crisis. As the Korean government has also established a Renewable Energy 3020 policy and promoted energy development plans using solar or wind power, large-scale offshore development projects not present before in coastal waters, such as offshore wind farms, are being promoted. From ships' point of view, offshore facilities present obstacles to safe navigation, and with the installation of marine facilities, ship collisions or contact accidents between ships and marine facilities may occur in the narrowed water areas. In addition, there are concerns about environmental pollution and human casualties caused by marine accidents. Accordingly, we review overseas and domestic offshore wind farm development plans, analyze whether institutional devices are in place to ensure the safe passage of ships in wind farm areas, and study the safe operation of large-scale offshore wind farms and safe passage of ships along the Korean coast by comparing overseas legislative cases with domestic laws and presenting a proposal to illuminate the legal blind sectors.

Implementation of Rule Management System for Validating Spatial Object Integrity (공간 객체 무결성 검증을 위한 규칙 관리 시스템의 구현)

  • Go, Goeng-Uk;Yu, Sang-Bong;Kim, Gi-Chang;Cha, Sang-Gyun
    • Journal of KIISE:Software and Applications
    • /
    • v.26 no.12
    • /
    • pp.1393-1403
    • /
    • 1999
  • 공간 데이타베이스 시스템을 통하여 공유되는 공간 데이타는 무결성이 적절하게 유지되지 않는 한 전체 응용 시스템의 행위를 예측할 수 없게 되므로 데이타의 무결성 확인 및 유지는 필수적이다. 특히 공공 GIS에 저장된 공간 데이타는 토지 이용도 평가, 도시 계획, 자원 관리, 시설물 관리, 안전 관리, 국방 등 국가 전체 및 지역의 중요한 정책 결정을 위한 다양한 응용 시스템들에 의해 이용되므로 적절한 공간 객체의 무결성 확인이 더욱 더 필요하다. 본 논문에서는 능동(active) DBMS의 능동 규칙(active rule) 기법을 이용하여 공간 객체의 무결성 확인을 지원하기 위한 규칙 관리 시스템을 제시한다. 능동 규칙을 이용한 공간 객체의 무결성 확인은 응용 프로그래머를 무결성 확인에 대한 부담으로부터 자유롭게 할 수 있다. 본 시스템은 특정 DBMS에 종속되지 않는 독립적인 외부 시스템으로 존재하며, 능동 규칙 관리기, 규칙 베이스, 그리고 활성규칙 생성기의 3 부분으로 구성된다. 사용자가 공간 데이타베이스 응용 프로그램을 통해 공간 객체를 조작하고자 할 때, 본 시스템은 데이타베이스 트랜잭션을 단위로 조작되는 모든 공간 객체의 무결성 확인을 위해 응용 프로그램에 삽입될 무결성 제약조건 규칙들을 효율적으로 관리하는 역할을 한다.Abstract It is necessary that the integrity of spatial data shared through the spatial database system is validated and appropriately maintained, otherwise the activity of whole application system is unpredictable. Specially, the integrity of spatial data stored in public GIS has to be validated, because those data are used by various applications which make a decision on an important policy of the region and/or whole nation such as evaluation of land use, city planning, resource management, facility management, risk management/safety supervision, national defense. In this paper, we propose rule management system to support validating the integrity of spatial object, using the technique of active rule technique from active DBMS. Validating data integrity using active rules allows database application programmer to be free from a burden on validation of the data integrity. This system is an independent, external system that is not subject to specific DBMS and consists of three parts, which are the active rule manager, the rule base, and the triggered rule generator. When an user tries to manipulate spatial objects through a spatial database application program, this system serves to efficiently manage integrity rules to be inserted into the application program to validate the integrity constraints of all the spatial objects manipulated by database transactions.

The Present State and Future Prospect of the Education for Marine Pollution Prevention Manager in Korea II. Marine Pollution Prevention Manager of Marine Facility (해양오염방지관리인 교육의 현황과 전망 II. 해양시설 오염방지관리인 교육)

  • Kim, Kwang-Soo;Cho, Dong-Oh;Yun, Jong-Hwui;Cho, Hyeon-Seo
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2009.06a
    • /
    • pp.113-119
    • /
    • 2009
  • Marine pollution prevention manager system has been operated for the purpose of preventing marine pollution from ships and marine facilities in Korea. As a new "marine environment management act" replacing an old "marine pollution prevention act" had entered into force from January 20. 2008. the works and business of the education and training courses for marine pollution prevention manager are scheduled to transfer from KIMFT(Korea Institute of Maritime and Fisheries Technology) and FHRDI(Fisheries Human Resource Development Institute) to KOEM(Korea Marine Environment Management Corporation) on January 1. 2011. The present state of the education and training for marine pollution prevention managers of marine facilities was surveyed and analyzed in order to prospect trainee demands for the education and training and to provide KOEM with basic data for establishing a new system for the education and training. The existing education and training courses of FHRDI for marine pollution prevention manager of marine facilities have been conducted as a regular course of 21 classes for 3 days. The average annual number of trainees in FHRDI for 6 years from 2003 to 2008 was 187 persons and the annual number of trainee was 202 persons in 2008. The trained demands for the education and training are expected to increase sooner or later, depending major factors such as the extension of fields and ranges for marine facilities and marine environment management business due to the enforcement of new "marine environment management act".

  • PDF

Development of Education and Training Programs and Job Analysis on 'Mechanical Facilities Maintenance Manager' Using DACUM (DACUM을 활용한 기계설비유지관리자 직무분석 및 교육훈련 프로그램 개발)

  • Oh, Chun Shik;Cho, Jeong Yoon;Jeong, Yousung;Song, Nakhyun
    • 대한공업교육학회지
    • /
    • v.44 no.2
    • /
    • pp.86-103
    • /
    • 2019
  • The purpose of this study is to provide basic data on the development of education and training programs for training 'mechanical facilities maintenance manager'. To this end, the DACUM technique was used for job analysis and education and training programs were developed through expert consultation meetings. The job analysis was based on the 10-member DACUM Committee to derive the job definition, job model, job description, and task description of the 'mechanical facilities maintenance manager'. The main findings are as follows. First, the 'mechanical facilities maintenance manager' was defined as those who operate, inspect, diagnose, and repair mechanical facilities to provide the best performance and efficient operation management, provide a safe and pleasant environment, and perform energy saving and facility life extension tasks. Second, the duties of the 'mechanical facilities maintenance manager' analyzed in the job model consist of the comprehensive plan for operation of mechanical facilities, energy management of mechanical facilities, operation management of mechanical facilities, maintenance of mechanical facilities, safety environment management of mechanical facilities, and customer support management of mechanical facilities. Considering the nature and content of the duties, 4 to 11 tasks per duty were derived and a total of 33 tasks were presented as job model. Third, the curriculum for the 'mechanical facilities maintenance manager' was set up in two courses: Practice I for Mechanical Facilities Maintenance and Practice II for Mechanical Facilities Maintenance. Considerations and policy suggestions were presented when applying and implementing education and training programs based on the results of the research.

Study of Decision Making Procedures for Follow-up Management of Water-friendly Riverfront (하천 내 친수지구의 사후관리 의사결정 절차 방법 연구)

  • Lee, Seung Yeon;Lee, Sang Eun;Kim, Na Hui;Lee, Seung Oh
    • Journal of Korean Society of Disaster and Security
    • /
    • v.14 no.4
    • /
    • pp.81-91
    • /
    • 2021
  • The reasonable decision making procedure for conducting follow-up management of water-friendly riverfront have been proposed in the national streams when the use of the level of usage for facility becomes degraded. It consists of two part usage: the selection of destination and the follow-up strategy with the alternatives. Considering the water-friendly riverfront grade derived from prior research, Grade IV and V were selected as candidates, and if the economic utility became low, it should be selected as candidates for the follow-up management. In addition, the basic plan for follow-up management was reviewed and alternatives suitable for the strategy could be derived considering the need for the operation of water-friendly riverfront in target site. The prior study on the follow-up decision making process of the water-friendly riverfront has not yet been confirmed, but since the life cycle of such facilities become almost expired, systematic procedures are needed to enable the use of administrative procedures for users' convenience and safety.

A Study on the Individual Radiation Exposure of Medical Facility Nuclear Workers by Job (의료기관 핵의학 종사자의 직무 별 개인피폭선량에 관한 연구)

  • Kang, Chun-Goo;Oh, Ki-Baek;Park, Hoon-Hee;Oh, Shin-Hyun;Park, Min-Soo;Kim, Jung-Yul;Lee, Jin-Kyu;Na, Soo-Kyung;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.9-16
    • /
    • 2010
  • Purpose: With increasing medical use of radiation and radioactive isotopes, there is a need to better manage the risk of radiation exposure. This study aims to grasp and analyze the individual radiation exposure situations of radiation-related workers in a medical facility by specific job, in order to instill awareness of radiation danger and to assist in safety and radiation exposure management for such workers. Materials and Methods: 1 January 2007 to 31 December 2009 to work in medical institutions are classified as radiation workers Nuclear personal radiation dosimeter regularly, continuously administered survey of 40 workers in three years of occupation to target, Imaging Unit beautifully, age, dose sector, job function-related tasks to identify the average annual dose for a deep dose, respectively, were analyzed. The frequency analysis and ANOVA analysis was performed. Results: Imaging Unit beautifully three years the annual dose PET and PET/CT in the work room 11.06~12.62 mSv dose showed the highest, gamma camera injection room 11.72 mSv with a higher average annual dose of occupation by the clinical technicians 8.92 mSv the highest, radiological 7.50 mSv, a nurse 2.61 mSv, the researchers 0.69 mSv, received 0.48 mSv, 0.35 mSv doctors orderly, and detail work employed the average annual dose of the PET and PET/CT work is 12.09 mSv showed the highest radiation dose, gamma camera injection work the 11.72 mSv, gamma camera imaging work 4.92 mSv, treatment and safety management and 2.98 mSv, a nurse working 2.96 mSv, management of 1.72 mSv, work image analysis 0.92 mSv, reading task 0.54 mSv, with receiving 0.51 mSv, 0.29 mSv research work, respectively. Dose sector average annual dose of the study subjects, 15 people (37.5%) than the 1 mSv dose distribution and 5 people (12.5%) and 1.01~5.0 mSv with the dose distribution was less than, 5.01~10.0 mSv in the 14 people (35.0%), 10.01~20.0 mSv in the 6 people (15.0%) of the distribution were analyzed. The average annual dose according to age in occupations that radiological workers 25~34 years old have the highest average of 8.69 mSv dose showed the average annual dose of tenure of 5~9 years in jobs radiation workers in the 9.5 mSv The average was the highest dose. Conclusion: These results suggest that medical radiation workers working in Nuclear Medicine radiation safety management of the majority of the current were carried out in the effectiveness, depending on job characteristics has been found that many differences. However, this requires efforts to minimize radiation exposure, and systematic training for them and for reasonable radiation exposure management system is needed.

  • PDF

A Method for Setting Energy Saving Goals of Existing Buildings - Based Energy Consumption Results Data - (기존 건축물의 에너지소비량 절감목표 산정 방법 - 에너지소비량 실적 데이터 기반 -)

  • Yeo, Changjae;Yu, Jungho;Moon, Hyunseok;Kim, Seungjin
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.3
    • /
    • pp.123-131
    • /
    • 2015
  • There are a number of policies that have been established to reduce greenhouse gases emissions and reduce energy consumption. These polices, however, only reflect the building energy consumption saving rate without considering building energy consumption characteristic. If building that already use less energy apply the same saving rate to reduce energy consumption, it is less effective. Therefore, this study classified building energy consumption characteristics and investigated approaches to adopt individual reduction rates according to energy consumption. Analysis results showed that there are differences in energy consumption depending on building use, and therefore, we classified buildings by use. We also proposed a formula to set a reduction goal for rate of energy consumption according to energy consumption. We verified our approach in a top-end neighborhood facility in Seoul. The energy consumption savings goal of this study can be applied individually, but determining whether a building can reduce energy consumption towards a saving goal requires a closer look at each building.

Analysis of Correlation between Freeze-Thaw Damage on Concrete and Chloride Penetration Acceleration Effect Using Surface Rebound Value (표면반발경도 활용 콘크리트 동해손상과 염분 침투 가속효과의 상관관계 분석)

  • Park, Ji-Sun;Lee, Jong-Suk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.148-156
    • /
    • 2022
  • Although most domestic concrete structures are simultaneously exposed to freeze-thaw and chloride environments, concrete durability in the field is evaluated by each single action, and the evaluation of chloride-caused damage of concrete requires additional indoor experimental analysis of chloride contents by coring samples from structures in the field. However, in Korea, policies to strengthen facility maintenance, such as 「Special Act on the Safety Control and Maintenance of Establishments」 and 「Framework Act on Sustainable Infrastructure Management」, have been established and implemented since 2018 and facilities subject to safety inspection management by the government and local governments increases, the effective simplification technology for the inspection and diagnosis of concrete structure is needed. Therefore, this study attempted to evaluate the possibility of determining the acceleration chloride penetration of freeze-thaw damaged concrete by using the surface rebound value. For this purpose, concrete specimens already having freeze-thaw damage by exposure to the freeze-thaw acceleration environment were immersed in chloride water. After that, the acceleration relationship of chloride penetration according to freeze-thaw damage was analyzed using the amount of chloride contents in concrete.