• Title/Summary/Keyword: facility safety management

Search Result 706, Processing Time 0.035 seconds

Evaluation of MCC seismic response according to the frequency contents through the shake table test

  • Chang, Sung-Jin;Jeong, Young-Soo;Eem, Seung-Hyun;Choi, In-Kil;Park, Dong-Uk
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1345-1356
    • /
    • 2021
  • Damage to nuclear power plants causes human casualties and environmental disasters. There are electrical facilities that control safety-related devices in nuclear power plants, and seismic performance is required for them. The 2016 Gyeongju earthquake had many high-frequency components. Therefore, there is a high possibility that an earthquake involving many high frequency components will occur in South Korea. As such, it is necessary to examine the safety of nuclear power plants against an earthquake with many high-frequency components. In this study, the shaking table test of electrical facilities was conducted against the design earthquake for nuclear power plants with a large low-frequency components and an earthquake with a large high-frequency components. The response characteristics of the earthquake with a large high-frequency components were identified by deriving the amplification factors of the response through the shaking table test. In addition, safety of electrical facility against the two aforementioned types of earthquakes with different seismic characteristics was confirmed through limit-state seismic tests. The electrical facility that was performed to the shaking table test in this study was a motor control center (MCC).

An Evaluation Method of Deterioration Level of Elementary, Middle, and High School (초·중등학교시설의 노후도 평가 방법)

  • Kim, Hyungeun;Ryu, Hanguk
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.16 no.2
    • /
    • pp.44-53
    • /
    • 2017
  • Facility management is to maintain and develop the primary structural, functional, aesthetic performance of facility in order to guaranty the users' daily convenience and safety. However it is hard to maintain and serve their intended function and safe environment from the beginning as times go by. As present educational government of city and local area has been performing formally facility check and management as well as maintenance of school facility, it is hard to respond a dangerous situation at the suitable time and safety prevention plans are delayed. In addition, educational environment improving budget have been unreasonably decided not according to the allocating criteria. Therefore, this research developed a same, simple, and quantitative evaluation method of deterioration level of elementary, middle, and high School in Korea and verified usability of the method through the case study.

A Study on the Actual Condition Analysis and Improvement Direction of Disaster Safety Education Training Course in School - Focused on Disaster Safety Management for School Facilities - (학교 재난안전 교육연수과정 실태분석 및 개선방향에 관한 연구 - 학교시설에 대한 재난안전관리 중심으로 -)

  • Lee, Byoung-Ho;Park, Youn-Ju;Lee, Jae-Rim
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.17 no.2
    • /
    • pp.11-21
    • /
    • 2018
  • This study suggests desirable disaster safety education curriculum through analyzing the operational status of the school disaster safety management training course and demand survey of school staff. First, the problem of the disaster safety training course of the school is not connected with the lack of law and system and the school disaster safety job. Second, improvement of law and system and variety of training should be made to acquire professional knowledge. Third, it is necessary to divide curriculum into the following four categories, according to educational needs of public officials ; Educational administration officers course focused on facility safety, maintenance and disaster countermeasure. Educational officials in technical post course addressing approval and permission of school facility projects, seismic reinforcement of school building, etc. Educational supervisors course covering roles and responsibilities of the school safety supervisors in the event of disaster. Teaching staffs course focused on safety instructions for students. Fourth, it is found that lectures and experiential learning methods are the most desirable methods of teaching and learning, and the major ranks are earthquake disaster, fire, gas, typhoon, school road, and electrical safety.

A Study on Technical High School Teachers' Consciousness of Prevention Safety Accidents (안전사고 예방교육 프로그램에 대한 공업고등학교 교사들의 안전의식 연구)

  • Han, Doo-Heui;Jung, Soo-Il
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2009.04a
    • /
    • pp.203-212
    • /
    • 2009
  • The purpose of this study is to collect and analyze Technical High School Teachers' opinions to find out solutions to reduce safety accidents since it is important for teachers to recognize the importance of safety. We surveyed 150 teachers from technical high schools located in Incheon and divided them into three categories and asked their opinions about prevention of safety accidents in laboratories. We also studied their experiences constructing educational environment and making instructional materials for safety eduction to improve safety awareness. Also, we studied whether school safety awareness increases through safety related activities.

  • PDF

The Survey of Construction Workers' Preference for Introducing the Emotional Safety in School Facility Construction - Focused on Emotional Safety Sensor and Emotional Facilities - (학교건축공사에 감성안전도입을 위한 근로자 선호도 조사 -감성안전센서와 감성안전 시설물 중심으로-)

  • Kim, Gwang-Hee
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.10 no.1
    • /
    • pp.26-33
    • /
    • 2011
  • The deaths caused by industrial accidents during the construction of the mortality rate is considerably higher than in other industries. To prevent such a disaster workers and to minimize unsafe behavior measures to be drawn, and construction companies recently to stimulate the emotions of the workers to participate in voluntary activities are safe. In this study, the construction workers can stimulate emotions and activities on the environment by examining the preferences of the workers on-site management will want to take advantage. This study revealed that the construction workers prefer the incentive most and then working environment.

A Railway Safety Proposal with Full System Commissioning (철도시스템의 종합시험운행을 통한 철도안전 확보방안)

  • Kim, Jeong-Joo;Lee, Hi-Sung;Moon, Dae-Seop
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.522-527
    • /
    • 2005
  • Rail network authority have to do the safety ensuring activities including the maintenance of railway facility, integrated performance verification between the facilities and related rolling stock and safety inspections, etc. When constructing the new lines or revising the conventional lines, full system commissioning should be done before the revenue service with railway operator. To develop the optimal full system commissioning model, the status of domestic and foreign railway facility and railway accidents are analysed and the problems of the safety management are derived. As one of countermeasures for the problems, the procedures and criteria for the full system commissioning are developed.

  • PDF

A Factor Analysis of Traffic Accidents Through Traffic Safety Diagnosis Results - Driver Factor - (교통안전진단 결과분석을 통한 교통사고 요인분석 - 사고자 요인을 중심으로 -)

  • Lee, Hwan-Seung;Ahn, Byung-Jun
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.2 s.74
    • /
    • pp.128-137
    • /
    • 2006
  • Traffic accidents occur due to complex influences of transportation companies, drivers, and road environment. This study found that education and surroundings for transportation companies, driving habits of drivers, and road safety facilities and accessory facilities were main factors that affected strongly traffic accidents. Also, it found that driving habits of drivers could affect accidents heavily more than two other factors. Road safety and accessory facilities were analysed that they affected traffic accidents independently with transportation companies and their own drivers. Therefore, in order to achieve a traffic accident prevention as our main target, those companies need to produce atmosphere that their own drivers can have safety awareness, and related institutions for the above target should run parallel with policy assistance and strict traffic enforcement. In the end, this study suggests that transportation companies should secure manpower wholly being charged with traffic safety and financial resources investing in it.

A Study on the Revitalization Plan of Changwon Persimmon Theme Park by Analyzing the Actual Condition of Rural Theme Park (농촌테마공원 실태분석을 통한 창원단감테마공원 활성화 방안)

  • Choi, Young-Wan;Eun, Hee-Chang;Kim, Young-Joo
    • Journal of Korean Society of Rural Planning
    • /
    • v.23 no.4
    • /
    • pp.91-98
    • /
    • 2017
  • The purpose of this study is to analyze the actual condition of the already established rural theme park, draw the weak and strong points, and come up with an efficient performance plan for Changwon Persimmon Theme Park through the benchmarking of the best overseas case. According to the analysis, it is necessary to introduce a facility and a program for family customers as a plan for promoting Changwon Persimmon Theme Park. It is required to secure safety through public operation and management, improve scalability of the facility through the establishment of multi-functional complex facility, and come up with a plan for operating a special program associated with local resources. Therefore, this study drew three activation factors: the establishment of operation and management system, the development of operation contents by facility, and the establishment of operation in each area. First, to establish the operation and management system, it is necessary to classify the organization of the theme park into the operation business area and into operation & management area by job function. Secondly, it is necessary to establish a special program in consideration of space and facility, suggest a differentiated plan for operation contents, and create a facility operation plan and program for Changwon Persimmon Theme Park. Lastly, to operate and manage Changwon Persimmon Theme Park smoothly, it is necessary to set the theme park space as open collaboration space which the local residents can share and participate in by avoiding the conventional administration-based business performance and operation. This study suggested the plan for establishing an operation and management system for Changwon Persimmon Theme Park and its operation, the establishment of a special program, a business performance strategy, and the use of internal and external spaces of the theme park.

- Development of Fuzzy Control System for Process with Irregular Information System - (불규칙한 정보 프로세스를 위한 퍼지제어 시스템 개발)

  • 박주식;김길동;강경식
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2003.11a
    • /
    • pp.185-198
    • /
    • 2003
  • This study is to develop and operate the R-FCE(Real-time Fuzzy Control Expert System) model on the SBR(Sequency Batch Reactors) type sewage disposal facility which is for the environmental problem of future and the effective treatment. It is the system that regularly handles the input, output information in real time by the Fuzzy control IF-THEN rule. Nowadays the water pollution caused by the increase of population and the industrialization already exceeds the purifying ability of nature and is getting worse. The sewage disposal facility needs an expert having wide experience and know-how because the quality or quantity of inflow water is so irregular that the process of sewage disposal is difficult. In the nation, however, the accumulation of technology is so weak because field-operators avoid the long-term duty. So the accurate and speedy decision or control of field are difficult in the case of emergency situation.

  • PDF

A Study on Improvement of Safety Management of Low Voltage Electrical Equiment (일반용 저압전기설비의 안전등급제 도입에 관한 연구)

  • Jae-Phil Han;Yong-Sung Choi
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.6
    • /
    • pp.598-602
    • /
    • 2023
  • With the purpose of instilling an awareness of the safety of users of electrical equipment and inducing voluntary facility improvement through the safety rating system for general low voltage electrical equipment, simulation and field application of the safety rating of general low voltage electrical equipment were conducted. For the introduction and application of the safety rating system for general low-voltage electrical equipment, data related to domestic safety was investigated and analyzed, cases of introduction in other fields were reviewed, and for design, the 4M risk assessment method of the Korea Occupational Safety and Health Agency and the cases of safety index development in Korea were analyzed and standardized. Safety rating system simulations were conducted for general low-voltage electrical equipment, and problem improvement measures were prepared by analyzing the results through on-site verification and simulation applied to the initial design. Design standards for the introduction of the safety rating system for general low-voltage electrical equipment were prepared, and 394 youth training facilities were applied to the field to see if the design standards were practically applicable to the field. With the application of the safety rating system for low-voltage electrical equipment for general use, youth training facilities that had been classified as 'appropriate' were able to induce an upgrade to a higher level through voluntary facility improvement according to the application of grades (A to E). As a result of inducing voluntary repair projects based on the results of the 1st and 2nd inspection of youth training facilities, it was confirmed that 86 facilities received grade A, 225 facilities received grade B, and only 311 facilities received grade A to B out of a total of 394 facilities, and there was no grade E.