Design of Pattern Array Method for Multi Data Augmentation of Power Equipment uisng Single Image Pattern (단일 이미지 패턴을 이용한 다수의 전력설비 데이터를 증강하기 위한 패턴 배열화 기법 설계)

  • Kim, Seoksoo
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.11
    • /
    • pp.1-8
    • /
    • 2020
  • As power consumption is maximized, research on augmented reality-based monitoring systems for on-site facility managers to maintain and repair power facilities is being actively conducted as individual power brokerages and power production facilities increase. However, in the case of existing augmented reality-based monitoring systems, it is difficult to accurately detect patterns due to problems such as external environment, facility complexity, and interference with the lighting environment, and it is not possible to match various sensing information and service information for power facilities to one pattern. there is a problem. For this reason, since sensor information is matched using a single image pattern for each sensor of a power facility, a plurality of image patterns are required to augment and provide all information. In this paper, we propose a single image pattern arrangement method that matches and provides a plurality of information through an array combination of feature patterns in a single image composed of a plurality of feature patterns.

Applications of Mobile GIS Solution for Utility Management (시설물관리를 위한 Mobile GIS 솔루션 활용)

  • 한승희;이용욱;이형석
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.20 no.1
    • /
    • pp.69-75
    • /
    • 2002
  • The important issues of facility database management in GIS are to collect up-to-date information and to update information in accordance with new-establishment, repair and replacement of the facilities. Therefore, it is necessary to develop a system which has capability of monitoring facilities as well as managing database efficiently. The purpose of this study is to propose possibility of implementation of mobile GIS solution for the facility management. In order to achieve the goal, to process existing digital maps and to receive on-site information through the wireless communication service are required. In addition, the system is required to process spatial information obtained by GPS and digital photogrammetric technique with real-time updating database in server. The system increases efficiency both in work flow and monitoring for facility management by providing optimal routing information to the sites and real-time two-way communication using VoIP(Voice over Internet Protocol). The system is expected to perform real-time database management effectively. In consequence, the system could appropriately response on-site situations in various practical applications. The proposed technology could contribute to improve nation's leading-edge technology.

Assessment of Selective Withdrawal Facility in the Imha Reservoir Using CE-QUAL-W2 Model (CE-QUAL-W2 모델을 이용한 임하호 선택배제시설의 효과분석)

  • Lee, Sanguk;Kim, Jeongkon;Noh, Joonwoo;Ko, Ick Hwan
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.2
    • /
    • pp.228-235
    • /
    • 2007
  • For efficient turbid water withdrawal in the Imha reservoir, a selective withdrawal facility was recently installed and operated during summer season of year 2006. In this research, CE-QUAL-W2 model was utilized to assess the efficiency of the selective withdrawal facility, in comparison with the original surface withdrawal, on turbid water management. Model calibration was carried out using data observed at four automatic monitoring stations in the reservoir. It was found that the model appropriately simulated, with the RMSE less than 5.2 NTU, the observed vertical and horizontal distributions of water temperature and turbidity as well as the location of maximum turbid water at each monitoring station. The analysis results showed that selective withdrawal is more effective in removing high turbid water than surface withdrawal as selective withdrawal contributed to reducing $35Mm^3$ of high turbidity water (> 100 NTU) in the reservoir by increasing outflows of high turbid water. Therefore, effective management of turbid water in the reservoir can be achieved by changing locations of intake depending on turbid water distribution conditions. The results of this study will provide some basic information for establishing better operation strategies to cope with turbid water problems.

Guard Lamp using Solar Cell (태양광을 이용한 정원등)

  • Kang Byung-Bog;Cha In-Su;Lim Jung-Yeol;Yoon Jeong-Phil;Park Se-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.129-132
    • /
    • 2004
  • A guard lamp system has been installed at the PV positive center, located at Gwangju in Korea. Digital environment that is represented to internet is displacing business way of industry and business achievement way with the fast speed being giving great change on life whole, improve existence business process utilizing internet and Web connection technology, information superhighway to tradition industrialist manufacture and e-transformation's propulsion that wish to maximize productivity and administration efficiency is spread vigorously. In this paper, we wish to accomplish generation equipment's heighten stability and believability through remote monitoring and control of guard lamp system. This paper describes the design of the monitoring system for the sensing data and indirect controlling of the guard lamp system. Most of the conventional monitoring systems depend on the special hardware and software. The essential design of monitoring system is to provide the convenience for the user and the portability for the system. In order for the system to fulfill its requirements, it was designed using Labview GUI facility based on the Windows 2000 environment of IBM PC compatible and Add-oncard based on the TCP/IP protocol. Advantage of the monitoring system are a personnel expenses curtailment effect, of the place restriction and unmanned system of the generationplants, etc..

  • PDF

Status of Loose Part Monitoring Technology and Facility in Domestic Nuclear Power Plant (국내 원전의 금속파편 감시기술 및 설비 현황)

  • Kim, Tae-Ryong;Lee, Jun-Shin;Sohn, Seok-Man
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.670-678
    • /
    • 2000
  • Loose parts monitoring system(LPMS) is one of the important monitoring systems for the safe and efficient operation of the nuclear reactor, since it is LPMS that can early detect loose parts which may cause a significant damage in facilities or components of the plant. Nuclear power plants in Korea have recently experienced several loose part alarms due to the metallic impact and it is expected that the frequency of the loose part will be increased along the aging of the plants. In this paper, the status of loose parts monitoring technologies and facilities in Korean nuclear power plants is presented for the establishment of LPMS installation plan in some nuclear reactors which are not yet equipped with LPMS. Sensor specification, location and mounting method for loose parts monitoring were reviewed. As a result, the location and the mounting method of the properly chosen sensor was recommended. Data acquisition algorithms and discriminating rules of loose part impact signals were also reviewed. Actual alarm cases occurred by true impact signal and false impact signal were stated here.

  • PDF

Construction of the remote monitoring system for MX-13 digital multiplexer (광회선 다중화장치 원격감시시스템 구축)

  • Jang, Moon-Jong;Park, Byung-Seok;Ahn, Seong-Joon;Woo, Hee-Gon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.2947-2949
    • /
    • 1999
  • The MX-13 digital multiplexer for leased line is one of the main facilities, so it is periodically monitored by the operator. Operators connect dummy terminal to the MX-13 digital multiplexer manually, and execute preventing inspection. When alarms occurred, they are manually checked by the operator. But, in order to get mere efficiency of accident prevention and monitoring facilities with rapid response to the accident symptom, and to get higher reliability from the companies who lease communication lines, we need to construct this system which is adequate to monitor IvlX-13 digital multiplexer in almost real time. We construct remote monitoring system for MX-13 digital multiplxer to meet those requirement. After constructing the system, it's possible that the local operator can manage local monitoring system to check the status of MX-13 digital multiplexers. Also, Center operator can monitor the facility which has problems, and located in the specific local areas with the use of Center monitoring system.

  • PDF

Analysis of pipe thickness reduction according to pH in FAC facility with In situ ultrasonic measurement real time monitoring

  • Oh, Se-Beom;Kim, Jongbeom;Lee, Jong-Yeon;Kim, Dong-Jin;Kim, Kyung-Mo
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.186-192
    • /
    • 2022
  • Flow accelerated corrosion (FAC) is a type of pipe corrosion in which the pipe thickness decreases depending on the fluid flow conditions. In nuclear power plants, FAC mainly occurs in the carbon steel pipes of a secondary system. However, because the temperature of a secondary system pipe is over 150 ℃, in situ monitoring using a conventional ultrasonic non-destructive testing method is difficult. In our previous study, we developed a waveguide ultrasonic thickness measurement system. In this study, we applied a waveguide ultrasonic thickness measurement system to monitor the thinning of the pipe according to the change in pH. The Korea Atomic Energy Research Institute installed FAC-proof facilities, enabling the monitoring of internal fluid flow conditions, which were fixed for ~1000 h to analyze the effect of the pH. The measurement system operated without failure for ~3000 h and the pipe thickness was found to be reduced by ~10% at pH 9 compared to that at pH 7. The thickness of the pipe was measured using a microscope after the experiment, and the reliability of the system was confirmed with less than 1% error. This technology is expected to also be applicable to the thickness-reduction monitoring of other high-temperature materials.

A Study on the Spatial Position Problem of PM Monitoring Stations Using Voronoi Technique and Density Analysis (보로노이 기법과 밀도분석을 활용한 미세먼지 측정소 공간적 위치 문제 연구)

  • Jeong, Jong-Chul
    • Journal of Cadastre & Land InformatiX
    • /
    • v.48 no.2
    • /
    • pp.185-195
    • /
    • 2018
  • In the Seoul Metropolitan City, the PM(pariculate matter) application used by the citizens provides the PM concentration of the nearest monitoring stations located on the PM monitoring stations. Currently, the selecting method of the PM monitoring network considered by the Ministry of Environment is based on considering the monitoring station distribution and population density only. In this study, we analyzed the distance between PM monitoring station and the administrative center point in addition to the above considerations. The number of test sites was verified and the range of coverage of each monitoring stations was indicated by using the Voronoi algorithm and hexagon grid. The spatial position problem of the PM monitoring station was suggested by spatial data analysis. The variables of spatial data analysis are single-family houses, apartments, $1^{st}$ class neighborhood, $2^{nd}$ class neighborhood, garbage disposal plant, hazardous material disposal facility, factory, and the density map. The analysis result of the selection criterion considering the additional variables for new PM monitoring stations was presented, in addition to the selection criteria provided by the Ministry of Environment.

A study on establishment of measurement and analysis frequency of maintenance monitoring in tunnel (터널 유지관리계측의 측정 및 분석주기 설정 연구)

  • Woo, Jong-Tae;Lee, Kang-Il
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.2
    • /
    • pp.117-129
    • /
    • 2012
  • In this study, research was performed to establish the measurement and frequency of analysis for maintenance monitoring by investigation of tunnel maintenance monitoring system in the tunnel which was installed in the Seoul metro line 5, 7 and 8, using that the domestic and foreign application case, results of analyzed maintenance monitoring in the domestic tunnel and legal safety management standard of the facility. The results of the monitoring management about analysis frequency to the present are considered that the problem about measuring frequency does not occur. According to the analysis results of the maintenance monitoring which are located on the 5, 6th subway line, they are analyzed that the stress of concrete lining and reinforced bar are converged gradually after 45 months. Therefore Monitoring of measurement and analysis frequency is conduct more often within about 4 years after the measuring instrument installation. Four years later, slowing the frequency of measurement is considered reasonable.

Implementation of Facility Management System for Plant Factory (식물공장 시설관리 시스템의 구현)

  • Lee, Yong-Woong;Seo, Beom-Seok;Kim, Chan-Woo;Kim, Kyung-Hee;Park, Yang-Ho;Shin, Chang-Sun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.2
    • /
    • pp.141-151
    • /
    • 2011
  • This paper suggests the Facility Management System for plant factory promising to be a core technology of the agriculture in the future. This system makes diagnoses that status from sensors or facilities in the factory for exact operation and monitors the internal environment with the control status in real-time. It is expected that we could operate a plant factory safely and effectively by using the system. The system consists of the data management module, the context provider module, the context interpreter module, the service provider module, the data storage and user interface. The system provide with the failure diagnosis service, the facility control service, and the high-reliability monitoring service via the interactions between above modules. The failure diagnosis service determines whether the sensors or facility devices are in failure or not, and informs the administrator of their conditions. The facility control service is activated in case if the facilities need to be managed during the diagnosis for failure or malfunction processes. The high-reliability monitoring service provides the administrator with verified data through the failure diagnosis service. Then we confirmed that the suggested system operates correctly through the system simulation.