• Title/Summary/Keyword: facility monitoring

Search Result 578, Processing Time 0.027 seconds

U-Service Model for Urban Facility Management (도시시설물관리를 위한 u-서비스 모델)

  • Yu, Sung-Yeol
    • Management & Information Systems Review
    • /
    • v.31 no.1
    • /
    • pp.167-182
    • /
    • 2012
  • Recently, interesting of u-city with ubiquitous computing technologies has increased. In this paper, we propose u-service model for urban facility management based on ubiquitous computing technologies. To propose the research purpose, we define business model for the service and u-service model. And, we propose service function, service process, and relationships between participants to give shape to u-service model. First, we present five service functions; remote monitoring, remote control and inquire, state information, field support, and facility history information. And, we propose overall service process and demand-supply relationship between participants.

  • PDF

Development of Smart Remote Terminal Unit for Water Treatment SCADA System (상하수도 원격감시제어 시스템 구현을 위한 스마트 RTU의 개발 및 적용)

  • Jang, Sang-Bok;Lee, Ho-Hyun;Hong, Sung-Taek;Chun, Myung-Geun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.2
    • /
    • pp.24-30
    • /
    • 2014
  • In this paper, a new remote terminal unit(hereafter RTU) is proposed to manage a wide range of applications and a variety of sensors (eg, pressure, water quality, temperature and humidity sensors, the amount of pollutants, $CO_2$, etc.) to monitor and control the facility such as water treatment plant, intake and effluent pumping station, water tank and distribution network. Fault status of local sensor devices and network are alerted by using the embedded fault handling capabilities of the RTU in the system and also sent to the fault handling server, by which fault can be easily monitored to users. The developed system was applied to one of K-water branch offices in Geoje city and improved its reliability and stability for controlling and monitoring water facility.

Study on Radioactive Contamination of Plant Nearby Nuclear Power Plant - Focused on Pinus thunbergii Parl. and Viburnum awabuki K. KOCH - (원전주변 지역 식물의 방사능 오탁에 관한 연구 - 해송과 아왜나무를 대상으로 -)

  • Kang, Tai-Ho;Zhao, Hong-Xia;Jeong, Jin-Wook;Kook, Seong-Do
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.16 no.3
    • /
    • pp.55-62
    • /
    • 2013
  • Generally, the radioactivity from NPP(Nuclear Power Plants) operation can be released below 3% of DRLs(Derived Release Limits) to environment. It was tried to understand which plant was efficient for absorbing radioactivity in this study. Pinus thunbergii Parl. and Viburnum awabuki K. KOCH were analyzed for radioisotope absorption. The samples were collected at three different locations depending on the distance from NPP at the vicinity 10km away, and 30km away. Gamma radionuclide was not detected from the samples, which means that the direct transition into the plant was not significant. Meanwhile, the very low level of radioactive tritium was detected in the samples. One remark was that every plant has different ability for tritium absorption. These results are expected to be applied to propagation and transplanting in radioactively contaminated area or reducing radioactivity in the soil and water near the plants.

A Development of Real-time Energy Usage Data Collection and Analysis System based on the IoT (IoT 기반의 실시간 에너지 사용 데이터 수집 및 분석 시스템 개발)

  • Hwang, Hyunsuk;Seo, Youngwon
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.3
    • /
    • pp.366-373
    • /
    • 2019
  • The development of monitoring and analysis systems to increase productivity while saving energy is needed as a method to reduce huge amount of energy consumed in the process of producing large forged products. In this paper, we propose a system to monitor and analyze energy usage in real-time collected from gas-meter, wattmeter, and thermometer based on IoT installed in forging factories. The system consists of a data collection server for collecting and processing data from IoT- based platform and existing SCADA equipment and ERP/MES system in forging factories, and an application server for providing services to users. To develop the system, the overall system structure is logically diagrammed, and the databases configuration and implementation modules to efficiently store and manage data are presented. In the future, the system will be utilized to reduce energy consumption by analyzing energy usage pattern and optimizing process works with real-time energy usage and production process data for each facility.

Real-time Reservoir Dam Status Evaluation System Using Wireless Sensor Network System (무선 센서 네트워크 시스템을 이용한 실시간 저수지 댐의 상태평가 시스템)

  • Yoo, Chanho;Kim, Seungwook;Hwang, Jungsoon;Na, Gihyuk;You, Kwangho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.12
    • /
    • pp.41-46
    • /
    • 2018
  • The wireless sensor network system has the advantage of confirming the behavior of the entire facility by improving the disadvantages of conventional monitoring system. As a result, it is widely proposed as safety diagnosis and measurement of structures, water management systems, and management systems for dam structures. However, there is a lack of research that can evaluate the condition of facilities such as safety at the same time as monitoring. In this study, it is proposed a wireless sensor network system which can evaluate the behavior characteristics of facilities and evaluate the safety status for improving the technical disadvantages on conventional monitoring system. The geotechnical risk factors for the reservoir dam facility were evaluated and the limit values for the risk factors causing the failure of the facility were set. In other words, the system was set up so that the risk factors can be measured and the limit status can be evaluated immediately for each factor. In this study, numerical analysis is carried out for seepage and slope stability analysis using the typical cross section for reservoir dams. The stress-porewater coupling finite difference numerical analysis is performed for establishing the limit displacement for reservoir dam structures. It is developed a system that can estimate the time to reach the critical value by regression analysis using the measured datas.

Research on Railway Safety Common Data Model and DDS Topic for Real-time Railway Safety Data Transmission

  • Park, Yunjung;Kim, Sang Ahm
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.5
    • /
    • pp.57-64
    • /
    • 2016
  • In this paper, we propose the design of railway safety common data model to provide common transformation method for collecting data from railway facility fields to Real-time railway safety monitoring and control system. This common data model is divided into five abstract sub-models according to the characteristics of data such as 'StateInfoMessage', 'ControlMessage', 'RequestMessage', 'ResponseMessage' and 'ExtendedXXXMessage'. This kind of model structure allows diverse heterogeneous data acquisitions and its common conversion method to DDS (Data Distribution Service) format to share data to the sub-systems of Real-time railway safety monitoring and control system. This paper contains the design of common data model and its DDS Topic expression for DDS communication, and presents two kinds of data transformation case studied for verification of the model design.

Radiation image mapping system (방사선 영상 매핑 장치)

  • 최영수;박순용;이종민
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1884-1887
    • /
    • 1997
  • The increasing concern over radiation exposure in the nuclear industry has fostered agrressive efforts to reduce the levels of radiation exposure. One area of the effot to reduce the radiation exposure is the development of a remote radiation monitoring system. Remote radiation monitoring can serve many benificaial functions reduce exposure to radiation by plant personnel, impruve the quality of the data that is collected and recognize the radiation environment easily. Radiation mapping system gives a good information that represents radiation level distribution. The system we have developed consists of a data acquistion parts, mobile robot and remote control parts. Data acquisition parts consist of radiation detection module and vision acquistion module which collect radiation data, visiion data and distance information. In remote control parts, the acquision data are processed and displayed. We have constructed radiation mapping image by overlaying the vision and radiation data. The radiation mapping techniques for displaying the results of the survey in an easily comprehendable form will facilitate a better understanding of the radiation environment in the facility. This system can reduce workers radiation exposure and aid to help work plan, so it has significant benifits in cost and safety.

  • PDF

Continuous Surveillance and Diagnostics System Using Neural Network (인공 신경 회로망을 이용한 핵물질 거동 감시 시스템 개발)

  • 최재형;한명철;박영수;김호동;홍종숙
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.1182-1185
    • /
    • 1995
  • This paper presents a novel technology for unattented continuous monitoring of radioactive material in hot cell environments. In this monitoring system, the surveillance camera data and NDA data are time synchronized and integrated into the same dimension through data processing. The integrated information is then fed into a neural network to generate diagnostics through data processing. the integrated information of the concept is tested for a spent nuclear fuel transprotation in an operational hot cell at KAERI. The presented integral part of the multi-sensory system and the analytical paradigm may provide an effective technologyical alternative for safeguarding new conceptual hot cell facilities, namely the Dupic facility.

  • PDF

Installation and Monitoring of Bankfiltration (including alluvial and riverbed deposits) Source Heat Pump Cooling System (강변여과수(충적층 및 하상)를 이용한 냉방시스템 설치 및 모니터링)

  • Jung, Woo-Sung;Hwang, Ki-Sup;Ahn, Young-Sub
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.5-8
    • /
    • 2006
  • The Alternative energy has lately attracted considerable attention due to the high oil price and environment problem. In this study, pilot test facility for using the geothermal energy source from riverbank filtration was constructed and monitoring devices are installed to estimate the efficiency of this system. Initial installation cost can be saved efficiently by connect ing a heat pump system into the exist ing pumping well in Changwon riverbank filtration site. One set of monitoring results during summer was presented and analyzed.

  • PDF

Highway bridge live loading assessment and load carrying capacity estimation using a health monitoring system

  • Moyo, Pilate;Brownjohn, James Mark William;Omenzetter, Piotr
    • Structural Engineering and Mechanics
    • /
    • v.18 no.5
    • /
    • pp.609-626
    • /
    • 2004
  • The Land Transport Authority of Singapore has a continuing program of highway bridge upgrading, to refurbish and strengthen bridges to allow for increasing vehicle traffic and increasing axle loads. One subject of this program has been a short span bridge taking a busy highway across a coastal inlet near a major port facility. Experiment-based structural assessments of the bridge were conducted before and after upgrading works including strengthening. Each assessment exercise comprised two separate components; a strain and acceleration monitoring exercise lasting approximately one month, and a full-scale dynamic test carried out in a single day. This paper reports the application of extreme value statistics to estimate bridge live loads using strain measurements.