Application of Risk-Based Inspection with Financial Risk for a Petrochemical Process (석유화학공정에서 재정적 위험도에 의한 위험기반검사의 적용)

  • Kim, Tae-Ok;Lee, Joong-Hee;Choi, Sung-Kyu;Lee, Hern-Chang;Jo, Ji-Hoon
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.4
    • /
    • pp.53-60
    • /
    • 2009
  • For the case of the facilities using utilities such as cooling water and steam, risk of the facilities is zero because the consequence of failure (COF) through equipment damage area is zero. Therefore, to improve the estimation method of the risk by COF through equipment damage area in the risk-based inspection (RBI), this study developed the procedures of RBI, in which the risk was estimated by COF through financial loss. And, the RBI program (KS-RBI Ver 3.1) was developed to establish inspection interval based on the risk of the facilities estimated by COF through equipment damage area and financial loss, simultaneously, and the developed RBI program was applied to a petrochemical process. As a result, risks of the facilities estimated by COF through financial loss were similar to risks by COF through the equipment damage area. But, for the case of the facilities using utilities or expensive facilities, the estimation method of the risk by COF through financial loss was more accurate than through equipment damage area.

  • PDF

Income Statement Analysis and Developing the Guidelines of Meal-pricing and Facilities Investment Cost in Contract-Managed High School Foodservice in Seoul (서울시내 고등학교 위탁급식의 재무성과 분석을 통한 급식비 및 투자비의 적정 수준 산정)

  • 양일선;현성원;김현아;신서영;조미나;박수연;차진아;이보숙
    • Journal of Nutrition and Health
    • /
    • v.36 no.5
    • /
    • pp.528-535
    • /
    • 2003
  • The purposes of this study were: 1) to investigate the operational and financial characteristics of contract-managed high school food services in Seoul, 2) to analyze the financial performance of high school food services 3) to develop guidelines for meal pricing and facilities investment costs. From Oct to Nov 2001, questionnaires were mailed to 249 high schools that were managed by contract food service companies. A 40.2% response rate was recorded. The results of this study were as follows: 1. Student enrollment in high schools run by contract-managed food services was 1,518, with a 68.5% participation rate in the school lunch program. The average meal price was 2,141 won. 2. Based on the income statement analysis, average total sales were 410,440,504 won and average net profit was 16,098,558 won. 3. The optimum food cost per meal was 1,200-1,300 won per meal, calculating using the methods of conversion factor, RDA (Recommended Daily Allowance), and nutrient exchange unit. 4. Guidelines for meal pricing were developed using the modified actual pricing method based on facilities investment cost, number of meals and food cost. The ratio of labor cost, general management expenses and ordinary profit were adopted from the schools with liability. The food cost, depreciation and interest cost were calculated based on unit meal. 5. The guideline for facilities investment was developed based on the number of meals, meal price and food cost. The guideline included the maximum facilities investment cost paid by the contract food service management company. (Korean J Nutrition 36(5): 528∼535, 2003)

An Analysis of Youth EEG based on the Emotional Color Scheme Images by Different Space of Community Facilities (공동주택 커뮤니티시설의 공간별 감성색채배색 이미지에 따른 청소년의 뇌파분석)

  • Hwang, Yeon-Sook;Kim, Sun-Young;Kim, Ju-Yeon
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.5
    • /
    • pp.171-178
    • /
    • 2013
  • In this study, we sought to find out the effect of different emotional interior images of the community facilities in an apartment complex on a youth brain wave by analyzing an Electroencephalograph (EEG). Based on the frequency of usage, we selected learning facilities, cultural facilities, and sport facilities. For brain stimulation, the visual stimulants with three different emotional words, cheerful, gentle, and elegant, were used based on I.R.I image scale. Overall, total nine different emotional images were used. Based on our findings, we conclude that: first, in order to improve learning concentration of the youth, a learning facility for the youth needs to be designed by skillfully combining the soft and comfortable colors from the gentle image and the murky and dark colors from the elegant image. Second, when designing a cultural facility, it is preferable to consider the elegant image for a calm and comfortable space. Third, a sport facility design needs to preclude dark colors and apply light colors to create a dynamic and lively space. Furthermore, we found out that the youth has established static images of each functionally different facility through their experience and learning. Therefore, it is imperative to plan community facilities in an apartment complex in a way to connect the space function with the emotional characteristics of the youth in order to support and encourage energetic activities and learning of the community youth.

Location Selection and Evaluation of Education and Research Facilities in Large City (대도시 교육연구시설의 입지선정 및 평가에 관한 연구)

  • Park, Cheon-Bo;Choi, Joon-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.676-682
    • /
    • 2017
  • The purpose of this study is to suggest the elements that need to be taken into consideration in urban planning to determine the optimal location of education and research facilities based on the knowledge-based industry in a large Korean city. In this study, we conducted an analysis and evaluation of the locational conditions and elements of education and research facilities as the important functions for regional economic revitalization and urban balance development. For this purpose, the relevant concepts and patterns of education and research facilities were reviewed as a theoretical research endeavor, and their locational conditions and elements were surveyed based on the existing research. The planning directions and some lessons for determining the location of the facilities are suggested through the analysis of the evaluation method according to the selection of the location. The results of this study are expected to act as guidelines for the optimal location selection of education and research facilities in large Korean cities in the era of the fourth industrial revolution.

A Study on the Maintenance Plan of Common Farming Facility Using Space Syntax (공간구문론을 이용한 농업공동시설 입지 방안에 관한 연구)

  • Lim, Chang-Su;Oh, Yun-Kyung;Kwon, Soon-Chan;Yoon, Gi-Eun;Kim, Eun-Ja;Park, Mi-Jung
    • Journal of Korean Society of Rural Planning
    • /
    • v.21 no.3
    • /
    • pp.131-144
    • /
    • 2015
  • With a view to creating beautiful farm villages, this study aims to exploit space syntax and thereby establish a systematic plan for refurbishing common farming facilities in farm villages by expanding a remodeling plan that has so far been focused on farm houses to cover different villages as well as in spatial scope. For this purpose, the study has extracted a system of categories for common ownership facilities in farm villages and applicable elements needed for collaboration in the space of joint production by performing a comprehensive analysis of related literature for the purpose of researching the distribution of common farming facilities. Based on such categorization of applicable elements, the study conducted a field survey of the four types of farm villages such as suburban area (Hwaseong), inland farming-centered area (Jeungpyeong), coastal & plain area (Goheung), and mid-mountain area (Gangneung), through group discussions by participating researchers and field pilot surveys. Also, space analysis has come up with measurements based on the five criteria of integration, local integration, control, connectivity, and spatial depth. And a plan for type-specific remodelling of common farming facilities has been drawn up through standardization based on the values in integration for different villages and spatial depth for common farming facilities. The significance of the current study consists in identifying how the location of common farming facilities influences the characteristics of different villages in terms of spatial structure and then drawing up guidelines for planning their placement.

A Study on the Evaluation and Improvement of Student Convenient Facilities at University Campuses, based on Universal Design Concept - Focused on the university campuses in Texas, U.S.A. - (유니버설디자인 개념에 의거한 대학내 학생편의시설 평가 및 개선방향에 대한 연구 - 미국 텍사스주를 중심으로 -)

  • Kim, Won-Pil
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.21 no.3
    • /
    • pp.19-28
    • /
    • 2014
  • Student halls and their convenient facilities have been a focal point for various student activities at university campus. It has been for most of the student a place of unique memories and of attachment often associated with those good and bad school days. However, it is questionable whether these facilities are supportive and accessible for all of the students and other users including the handicapped. Therefore, based on the concept of UD(universal design) which was widely applied to U.S. institutions, this study intended to evaluate student hall facilities in U.S. and to provide an improvement direction for Korean UD application. For that purpose, four universities were selected for an in-depth analysis and 76 survey indices were utilized based on previous research. It was found that (1) design consideration without braille sign for VIP(visually impaired person) in student buildings can be differently approached with electronic devices; (2) the best demonstration of UD in student buildings can be seen in spacious flat pathway, easy access through ramp and wide entry area, necessary for people in wheel-chairs, but used by all, implying an increase of the ratio of public space; (3) one of the good UD features is an attractive physical environment rather than institutional appearance, in which they ultimately will support and completely adaptable at optimal levels by everyone; (4) consistent maintenance and management maximize the potential of UD principles and minimize physical limitations.

Comparing Stakeholder Perceptions on the Reasons for Rural Underutilization of Common Facilities (농촌지역 개발사업 공동시설의 활용도 기준체계 정립을 통한 실태 파악 연구)

  • Kim, Eun-Sol;Lee, Jae Ho
    • Journal of Korean Society of Rural Planning
    • /
    • v.29 no.3
    • /
    • pp.53-67
    • /
    • 2023
  • In this study, the problem of the idleness of public buildings in rural areas is seriously emerging, but there are no clear standards for assessing the utilization of these buildings. Therefore, this study endeavors to investigate the actual state of idleness of buildings created by rural area development projects based on the criteria for each type. As part of this study, rural facilities were selected in two locations in Sangju City and Miryang City among the target areas of the Rural Agreement. Utilization evaluation criteria were developed to identify the conditions of underutilization. In order to determine the utilization pattern for each facility type, an in-depth interview with the operator and an inspection of the facility were conducted. Based on the analysis, the degree of utilization (e.g., low use, non-use, etc.) was different for each facility type, and among the four facility types (rural tourism, culture and welfare, exercise and recreation, income-based), rural tourism was rated as the least efficient. It has been found that the operating entity's capacity has a significant influence on the utilization of facilities. Socioeconomic factors, such as a decrease in utilization rates, are greatly influenced by the operating entity's capacity. Therefore, support from local governments as well as the national level is required to recycle idle facilities. Lastly, this study suggests the need for different standards for utilization, depending on the type of facility. This moves beyond checking the degree of idleness by the same standard that was previously implemented.

Introduction of Requirements and Regulatory Guide on Cyber Security of I&C Systems in Nuclear Facilities (원전 계측제어시스템의 사이버보안 요구사항)

  • Kang, Young-Doo;Jeong, Choong-Heui;Chong, Kil-To
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.209-210
    • /
    • 2008
  • In the case of unauthorized individuals, systems and entities or process threatening the instrumentation and control systems of nuclear facilities using the intrinsic vulnerabilities of digital based technologies, those systems may lose their own required functions. The loss of required functions of the critical systems of nuclear facilities may seriously affect the safety of nuclear facilities. Consequently, digital instrumentation and control systems, which perform functions important to safety, should be designed and operated to respond to cyber threats capitalizing on the vulnerabilities of digital based technologies. To make it possible, the developers and licensees of nuclear facilities should perform appropriate cyber security program throughout the whole life cycle of digital instrumentation and control systems. Under the goal of securing the safety of nuclear facilities, this paper presents the KINS' regulatory position on cyber security program to remove the cyber threats that exploit the vulnerabilities of digital instrumentation and control systems and to mitigate the effect of such threats. Presented regulatory position includes establishing the cyber security policy and plan, analyzing and classifying the cyber threats and cyber security assessment of digital instrumentation and control systems.

  • PDF

Evaluation of Service Quality in Aged Care Facilities : A Focus Group Study (노인장기요양시설 서비스의 질 평가 탐색 : 포커스 그룹 연구)

  • Lee, JungSuk;Lee, Yong-Mi;Hwang, RahIl
    • Journal of Korean Public Health Nursing
    • /
    • v.31 no.1
    • /
    • pp.19-33
    • /
    • 2017
  • Purpose: This study was conducted to explore the meaning and contents of high-quality aged care facilities and provide basic data for evaluation of service quality in such facilities. Methods: The focus group interviews and participants consisted of two user groups, for a total of 16 family caregivers of the elderly living in facilities and four service provider groups, for a total of 26 chief managers and caregivers working in aged care facilities. All interviews were recorded and transcribed as they occurred. Content analysis was used and debriefing notes were referred to in order to analyze the data. Results: Four themes of a high-quality aged care facility emerged from the analysis; 1) a place to rest for comfortable later years; 2) systematic value-based management; 3) providing professional care; 4) comprehensive service provision in response to diverse needs. Conclusion: The findings of the study showed the importance of client centered care and ethical mindset of providers, which had not been included in the existing quality evaluation programs. Based on these results, medical treatments, end-of-life care and more comprehensive and extended services including family care need to be provided in facilities to ensure good quality aged care.

Application of Percentile Rainfall Event for Analysis of Infiltration Facilities used by Prior Consultation for LID (Low Impact Development)

  • Kwon, Kyung-Ho;Song, Hye-Jin
    • KIEAE Journal
    • /
    • v.15 no.5
    • /
    • pp.5-12
    • /
    • 2015
  • Purpose: Retention and infiltration of small and frequently-occurring rainfall by LID facilities account for a large proportion of the annual precipitation volume. Based on 4 standard facilities such as Porous Pavement, Infiltration Trench, Cylindrical Infiltration Well, Rectangular Infiltration Well by Seoul Metropolitan Handbook of the Prior Consultation for LID. The total retention volume of each facility was calculated according to the type and size. The Purpose of this study is to find out the quantitative relationship between Percentile Rainfall Event and Design Volume of Infiltration Facilities. Methode: For the estimation of Percentile Rainfall Event, Daily Precipitation of Seoul from 2005 to 2014 was sorted ascending and the distribution of percentile was estimated by PERCENTILE spreadsheet function. The managed Rainfall Depth and Percentile of each facility was calculated at the several sizes. In response to the rainwater charge volume of 5.5mm/hr by the Category "Private large site", the 3 types of facilities were planned for example. The calculated Rainfall Depth and Percentile were 54.4mm and 90% by the use of developed Calculation-Module based on the Spreadsheet program. Result: With this Module the existing Designed Infiltration volume which was introduced from Japan was simply converted to the Percentile-Rainfall-Event used in USA.