• Title/Summary/Keyword: fabry-perot interferometer

Search Result 103, Processing Time 0.023 seconds

THE SIMULATION OF A FABRY-PEROT INTERFEROMETER (파브리-페로 간섭계의 시뮬레이션)

  • 최기혁;데이빗리즈
    • Journal of Astronomy and Space Sciences
    • /
    • v.14 no.1
    • /
    • pp.117-125
    • /
    • 1997
  • A Fabry-Perot interferometer has a very high (~1,000,000) resolution, so recently this has been widely used for many fields of space science. To understand the working principle of this a mathematical modeling is needed, and to analyze the interferogram it is essential to know the precise instrument function. The spectrum from the interferometer is mixed with a true signal from the light source and the instrument function through convolution. The true signal has the information about the quantum state of mo lecules, temperature and bulk motion of the gas. Therefore if we model the signal and convolve this with the theoretical instrument function we can predict the spectrum for the real case.

  • PDF

A Study on the Characteristics analysis of Optic Tunable Filter Using Fabry-Perot Interferometer (FPI를 이용한 파장가변 광 필터 특성분석에 관한 연구)

  • Jang, Woo-Soon
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.3-6
    • /
    • 2005
  • In this thesis, We researched on the characteristics of optical tunable filter that selects the channel by the wavelength changes of transmission spectrum when we apply outer physical quantities on a fiber bragg grating by using Fabry-Perot Interformer's operational principle.

  • PDF

Spectroscopic methods for the analysis of tandem fabry-perot interferometer (이중 패브리-페로 간섭계에 대한 분광학적 분석방법)

  • 이석목
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.231-237
    • /
    • 1994
  • We present spectroscopic methods to analyze the structural parameters of tandem Fabry-Perot interferometers. By using laser beams of two different frequencies by several tens of GHz, we investigated the cavity spacings of the two interferometers and ways to measure and to find the limitation of the neccesary conditions between the two interferometers. All of the theoretical results has been also confirmed experimentally.ntally.

  • PDF

SOLAR CYCLE VARIATION OF UPPER THERMOSPHERIC TEMPERATURE OVER KING SEJONG STATION, ANTARCTICA

  • Chung, Jong-Kyun;Won, Young-In;Kim, Yong-Ha;Lee, Bang-Yong;Kim, Jhoon
    • Journal of Astronomy and Space Sciences
    • /
    • v.17 no.2
    • /
    • pp.241-248
    • /
    • 2000
  • A groung Fabry-Perot interferometer has been used to measure atomic oxygen nightglow (OI 630.0nm) from the thermosphere (about 250km) at King Sejong station (KSS, geographic: $62.22^{\circ}$S, $301.25^{\circ}$E; geomagnetic: $50.65^{\circ}$S, $7.51^{\circ}$E), Antarctica. While numerous studies of the thermosphere have been performed on high latitude using ground-based Fabry-Perot interferometers, the thermospheric measurements in the Southern Hemisphere are relatively new and sparse. Therefore, the nightglow measurements at KSS play an important role in extending the thermospheric studies to the Southern Hemisphere. In this study, we investigated the effects of the geomagnetic and solar activities on the thermospheric neutral temperatures that have been observed at KSS in 1989 and 1997. The measured average temperatures are 1400K in 1989 and 800K in 1997, reflecting the influence of the solar activity. The measurements were compared with empirical models, MSIS-86 and semi-empirical model, VSH.

  • PDF

The measurement of the internal strain of a concrete specimen using optical fiber interferometric sensors (광섬유 간섭계 센서를 이용한 콘크리트 구조물의 내부 스트레인 측정)

  • Lee, Kyung-Jin;Park, Jae-Hee;Kang, Shin-Won
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.6
    • /
    • pp.304-309
    • /
    • 2001
  • A Fiber optic strain sensor for the measurement of the internal strain of a concrete specimen was developed. This sensor was a 11 mm Fiber-optic Fabry-Perot interferometer attached inside a stainless steel pipe of 2 mm diameter. The fabricated strain sensors were embedded in a reinforced concrete structure of $100{\times}100{\times}500\;mm^3$ size and were measured the internal strain of a concrete structure when the external pressure was applied to the structure. For a field application, the strain sensors were attached on the bottom of a real bridge and dynamic loading test were executed. In the test, they showed good sensitivity as a deformation sensor and capability of remote monitoring.

  • PDF

A study on the pressure characteristics of FFPI pressure sensor using the Si diaphragm (Si 다이아프램은 사용한 FFPI압력센서의 압력특성에 환한 연구)

  • 정주영;김경찬;박재희
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.6
    • /
    • pp.463-467
    • /
    • 2001
  • In this study, we developed a FFPI (fiber optic Fabry-Perot interferometer) pressure sensor using the Si diaphragm which measures pressure in vivo. The diaphragm and its supporting structure were etched in KOH solution and were fabricated with micromachining technology. For the configuration of the sensor, the length of the cavity of the Fabry-Perot etalon is 15 mm and one end of the etalon was bonded to a Si diaphragm with 507m thickness. When the area of the Si diaphragm was 2$\times$2 mm2 (cavity length 15 mm), it turns out that the pressure sensitivity was about 1.5 degree/kPa. The pressure sensor developed in this study showed that the phase change was linearly proportional to the increasing pressure in the range of 80 kPa.

  • PDF

Simply Modified Biosensor for the Detection of Human IgG Based on Protein AModified Porous Silicon Interferometer

  • Park, Jae-Hyun;Koh, Young-Dae;Ko, Young-Chun;Sohn, Hong-Lae
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.7
    • /
    • pp.1593-1597
    • /
    • 2009
  • A biosensor has been developed based on induced wavelength shifts in the Fabry-Perot fringes in the visible reflection spectrum of appropriately derivatized thin films of porous silicon semiconductors. Porous silicon (PSi) was generated by an electrochemical etching of silicon wafer using two electrode configurations in aqueous ethanolic HF solution. Porous silicon displayed Fabry-Perot fringe patterns whose reflection maxima varied spatially across the porous silicon. The sensor system studied consisted of a mono layer of porous silicon modified with Protein A. The system was probed with various fragments of an aqueous Human Immunoglobin G (Ig G) analyte. The sensor operated by measurement of the Fabry-Perot fringes in the white light reflection spectrum from the porous silicon layer. Molecular binding was detected as a shift in wavelength of these fringes.

A Phase Stabilization System of EFPI for Damage Detection of Composite (복합재료 파손 검출을 위한 EFPI 센서 위상 안정화 시스템)

  • Kim,Dae-Hyeon;Gu,Bon-Yong;Bang,Hyeong-Jun;Kim,Cheon-Gon;Hong,Chang-Seon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.8
    • /
    • pp.44-49
    • /
    • 2003
  • In case of an extrinsic Fabry-Perot interferometric sensor, the phase compensating technique is particularly necessary in applying the interferometer to detecting acoustic emission signals because of signal-fading problems. The technique makes it possible to maintain the phase at the quadrature point. In this paper, we developed the stabilization control sensor system that is composed of a broadband light source, a tunable Fabry-Perot (F-P) filter and a control-circuit board. A tension test of a composite specimen was performed to verify if the developed system could compensate the phase change induced from the tension strain and keep the phase at the quadrature point.

Characteristics of A Diaphragm-Type Fiber Optic Fabry-Perot Interferometric Pressure Sensor Using A Dielectric Film (유전체 박막을 이용한 다이아프램형 광섬유 Fabry-Perot 간섭계 압력센서의 특성)

  • Kim, M.G.;Yoo, Y.W.;Kwon, D.H.;Lee, J.H.;Kim, J.S.;Park, J.H.;Chai, Y.Y.;Sohn, B.K.
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.147-153
    • /
    • 1998
  • The strain characteristics of a fiber optic Fabry-Perot pressure sensor with high sensitivity using a $Si_{3}N_{4}/SiO_{2}/Si_{3}N_{4}$ (N/O/N) diaphragm is experimentally investigated. A 600 nm thick N/O/N diaphragm was fabricated by silicon anisotropic etching technology in 44 wt% KOH solution. An interferometric fiber optic pressure sensor has been manufactured by using a fiber optic Fabry-Perot intereferometer and a N/O/N diaphragm. The 2 cm length fiber optic Fabry-Perot interferometers in the continuous length of single mode fiber were produced with two pieces of single mode fiber coated with $TiO_{2}$ dielectric film utilizing the fusion splicing technique. The one end of the fiber optic Fabry-Perot interferometer was bonded to a N/O/N diaphragm. and the other end was connected to an optical setup through a 3 dB coupler. For the N/O/N diaphragm sized $2{\times}2\;mm^{2}$ and $8{\times}8\;mm^{2}$, the pressure sensitivity was measured 0.11 rad/kPa and 1.57 rad/kPa, respectively, and both of the nonlinearities were less than 0.2% FS.

  • PDF

A Stable 40 GHz Pulse Train Generation by Pulse Repetition-Frequency Quadruplication Using a Fiber Fabry-Perot Interferometer

  • Ruan, Wan-Yong;Park, Jae-Hyun;Seo, Dong-Sun
    • Journal of IKEEE
    • /
    • v.12 no.4
    • /
    • pp.234-238
    • /
    • 2008
  • We demonstrate a simple method to generate a stable 40 GHz pulse train at 1550 nm by spectral filtering of a 10 GHz mode.locked pulse source using a fiber Fabry-Perot interferometer (FFPI). A high finesse FFPI with a 40 GHz free spectral range blocks successfully unwanted spectral components of a 10 GHz pulse source and passes only 40 GHz spaced spectral lines ensuring pulse repetition-frequency quadruplication of the input pulses.

  • PDF