• Title/Summary/Keyword: eye vision

Search Result 453, Processing Time 0.027 seconds

Comparison of Dynamic Stereoacuity According to Dominant Eye and Degree of Dominant Eye (우세안의 방향과 강도에 따른 동적 입체시 비교)

  • Shim, Moon-Sik;Shim, Hyun-Suk;Kim, Young-Cheong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.3
    • /
    • pp.227-233
    • /
    • 2016
  • Purpose: On this study, we compared the relationship of dynamic stereoacuity according to the dominant eye, degree of dominant eye, and dominant agreement eye and hand. Methods: For 130 adults (male 70, female 60), mean age of $21.06{\pm}2.21years$ old, dominant eye, degree of dominant eye were measured by objective examination by using the diameter $3.8cm{\times}3.8cm$ thin ring, the dynamic stereoacuity were measured by three-rods test (iNT, Korea). Results: Dynamic stereoacuity according to the dominant eye was center dominant eye without dominance was $14.97{\pm}13.80sec$ of arc, right eye $22.10{\pm}20.01sec$ of arc, left eye $22.31{\pm}20.39sec$ of arc. Dynamic stereoacuity was better when there was no dominance, but the correlation of the dominant eye with dynamic stereoacuity was very low. When Dynamic stereoacuity was separated by in the Center, Mild, Strong, dynamic stereoacuity was $14.97{\pm}13.80sec$ of arc, $20.76{\pm}15.73sec$ of arc and $24.45{\pm}25.60sec$ of arc respectively. The dynamic stereoacuity results were worse when dominance was stonger. However dynamic stereoacuity was better than Center when the degree of dominant eye was rather strong in the dominant left eye. Dynamic stereoacuity according to the dominant eye and hand showed that right eye and hand was $22.63{\pm}20.54sec$ of arc, left eye and hand was $17.36{\pm}10.13sec$ of arc, right eye and left hand was $14.79{\pm}7.05sec$ of arc, left eye and right hand was $22.97{\pm}21.42sec$ of arc so dynamic stereoacuity was comparatively good when the dominant hand was left. Conculsions: Correlation between the dynamic stereoacuity according to the dominant eye, degree of dominant eye was low, however when degree of dominant eye was Center 14.97 sec of arc, Strong 24.45 sec of arc, the dynamic stereoacuity tended to worse when degree of dominant eye was strong. As a result, dominant eye, degree of dominant eye would have to be considered in a more comfortable binocular balance between prescribed for the wearer in binocular vision correction in binocular function such stereoacuity, sports vision training, presbyopia correction and mono vision.

Physiology of Eye Movements (안구 운동의 생리)

  • Kim, Ji Soo
    • Annals of Clinical Neurophysiology
    • /
    • v.1 no.2
    • /
    • pp.173-181
    • /
    • 1999
  • Eye movements serve vision by placing the image of an object on the fovea of each retina, and by preventing slippage of images on the retina. The brain employs two modes of ocular motor control, fast eye movements (saccades) and smooth eye movements. Saccades bring the fovea to a target, and smooth eye movements prevent retinal image slip. Smooth eye movements comprise smooth pursuit, the optokinetic reflex, the vestibulo-ocular reflex (VOR), vergence, and fixation. Saccades achieve rapid refixation of targets that fall on the extrafoveal retina by moving the eyes at peak velocities that can exceed $700^{\circ}/s$. Various brain lesions can affect saccadic latency, velocity, or accuracy. Smooth pursuit maintains fixation of a slowly moving target. The pursuit system responds to slippage of an image near the fovea in order to accelerate the eyes to a velocity that matches that of the target. When smooth eye movements velocity fails to match target velocity, catch-up saccades are used to compensate for limited smooth pursuit velocities. The VOR subserves vision by generating conjugate eye movements that are equal and opposite to head movements. If the VOR gain (the ratio of eye velocity to head velocity) is too high or too low, the target image is off the fovea, and head motion causes oscillopsia, an illusory to-and-fro movement of the environment.

  • PDF

Stereo matching algorithm based on systolic array architecture using edges and pixel data (에지 및 픽셀 데이터를 이용한 어레이구조의 스테레오 매칭 알고리즘)

  • Jung, Woo-Young;Park, Sung-Chan;Jung, Hong
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.777-780
    • /
    • 2003
  • We have tried to create a vision system like human eye for a long time. We have obtained some distinguished results through many studies. Stereo vision is the most similar to human eye among those. This is the process of recreating 3-D spatial information from a pair of 2-D images. In this paper, we have designed a stereo matching algorithm based on systolic array architecture using edges and pixel data. This is more advanced vision system that improves some problems of previous stereo vision systems. This decreases noise and improves matching rate using edges and pixel data and also improves processing speed using high integration one chip FPGA and compact modules. We can apply this to robot vision and automatic control vehicles and artificial satellites.

  • PDF

The Relationships Between Low Vision and Socioeconomic Status in Korean Adults (저시력과 사회경제적 상태와의 관계)

  • Park, Jee-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.319-325
    • /
    • 2011
  • Purpose: The relativity of factors between low vision and socioeconomic status were investigated. This study represented the preliminary data for establishment of public eye health policy. Further, this report would encourage people to change the social attitudes about the eye health equity of the nation. Methods: The number of people (2,514 people) who have been tested the forced visual activity were examined as it was referred the Korea National Health and Nutrition Examination Survey (KNHNE) of 2009-year data. The prevalence rate of low vision of subjects which are related with house income, education level and occupations were conducted with ttest and chi square test. Besides, the Binominal Logistic Regression was conducted to measure the odds ratio of the subjects. Results: In outline, the prevalence rate of low vision was high with low house income, low education level and low function. The odds ratio represented that 2.77(95% CI, 1.72-4.47) at low house income group and 4.02(95% CI, 1.75-9.23) at the case of below primary school education level. Moreover, the results of unemployed group showed 3.65(1.14-11.68) from the odds ratio measurement. Conclusions: The eye health policy need be instituted which is broad and meticulous support to ease the eye health equity of low eye sight patients. For instance, the education about eye health, examination business of eye disease, and education of assistant units which are useful for low eye sight would suggest practical solution.

The Awareness Survey of Vision Correction Surgery Side Effect (시력교정술 부작용 인지도 조사)

  • Lee, Jeung-Young;Seo, Jung-Ick;Park, Eun-Kyoo
    • Journal of Korean Clinical Health Science
    • /
    • v.4 no.4
    • /
    • pp.737-741
    • /
    • 2016
  • Purpose. To investigate awareness of vision correction surgery side effects and investigated side effects affect vision correction surgery decisions. Methods. This study was performed on 85 college students. The awareness of vision correction surgery, the awareness of vision correction surgery side effects, and investigated side effects affect surgery decisions. Results. 37.6 % (32 people) replied that the drying effects is representative side effects of the eye correction surgery. 68.2% (58 people) answered the reason of eye surgery is uncomfortable wearing glasses. 74.1%(63 people) answered the side effects does not affect vision correction surgery decision. Prior to hear a description of side effects, 31.8% percent people hope the surgery. after listening to explain of side effects, only 10.6% percent people hope the surgery. Conclusions. People who want to get vision correction surgery should check their vision condition through prior examination and consultation. What side effects in the operation should be reviewed. That is the only way to reduce side effects.

Recognition Performance of Vestibular-Ocular Reflex Based Vision Tracking System for Mobile Robot (이동 로봇을 위한 전정안반사 기반 비젼 추적 시스템의 인식 성능 평가)

  • Park, Jae-Hong;Bhan, Wook;Choi, Tae-Young;Kwon, Hyun-Il;Cho, Dong-Il;Kim, Kwang-Soo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.5
    • /
    • pp.496-504
    • /
    • 2009
  • This paper presents a recognition performance of VOR (Vestibular-Ocular Reflex) based vision tracking system for mobile robot. The VOR is a reflex eye movement which, during head movements, produces an eye movement in the direction opposite to the head movement, thus maintaining the image of interested objects placed on the center of retina. We applied this physiological concept to the vision tracking system for high recognition performance in mobile environments. The proposed method was implemented in a vision tracking system consisting of a motion sensor module and an actuation module with vision sensor. We tested the developed system on an x/y stage and a rate table for linear motion and angular motion, respectively. The experimental results show that the recognition rates of the VOR-based method are three times more than non-VOR conventional vision system, which is mainly due to the fact that VOR-based vision tracking system has the line of sight of vision system to be fixed to the object, eventually reducing the blurring effect of images under the dynamic environment. It suggests that the VOR concept proposed in this paper can be applied efficiently to the vision tracking system for mobile robot.

Visual Performances of the Corrected Navarro Accommodation-Dependent Finite Model Eye (안구의 굴절능 조절을 고려한 수정된 Navarro 정밀모형안의 시성능 분석)

  • Choi, Ka-Ul;Song, Seok-Ho;Kim, Sang-Gee
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.5
    • /
    • pp.337-344
    • /
    • 2007
  • In recent years, there has been rapid progress in different areas of vision science, such as refractive surgical procedures, contact lenses and spectacles, and near vision. This progress requires a highly accurate modeling of optical performance of the human eyes in different accommodation states. A new novel model-eye was designed using the Navarro accommodation-dependent finite model eye. For each of the vergence distances, ocular wavefront error, accommodative response, and visual acuity were calculated. Using the new model eye ocular wavefront error, accommodation dative response, and visual acuity are calculated for six vergence stimuli, -0.17D, 1D, 2D, 3D, 4D and -5D. Also, $3^{rd}\;and\;4^{th}$ order aberrations, modulation transfer function, and visual acuity of the accommodation-dependent model eye were analyzed. These results are well-matched to anatomical, biometric, and optical realities. Our corrected accommodation-dependent model-eye may provide a more accurate way to evaluate optical transfer functions and optical performances of the human eye.

Ginseng for an eye: effects of ginseng on ocular diseases

  • Kim, Jisu;Han, Su-Young;Min, Hyeyoung
    • Journal of Ginseng Research
    • /
    • v.44 no.1
    • /
    • pp.1-7
    • /
    • 2020
  • The sense of vision is the primary means by which we gather information from our surroundings, and vision loss, therefore, severely compromises the life of the affected individuals, their families, and society. Loss of vision becomes more frequent with age, and diabetic retinopathy, age-related macular degeneration, cataracts, and glaucoma are the major causes of vision impairment. To find active pharmacological compounds that might prevent or ameliorate the vision-threatening eye diseases, numerous studies have been performed, and some botanical compounds, including those extracted from ginseng, have been shown to possess beneficial effects in the treatment or prevention of common ocular diseases. In this review, we summarize the recent reports investigating the therapeutic effects of ginseng and ginsenosides on diverse ocular diseases and discuss their therapeutic potential.

Effectiveness of the Verif $EYE^{TM}$ machine -vision technology for complying with reducing microbial indicator counts on beef carcasses

  • Lee, Jeong-Ah;Kim, Sa-Hyun;Lee, Sang-Koan;Kim, Gi-Cheol;Oh, Hye-Won;Jung, Tae-Nam;Lee, Yang-Soo;Jung, Chang-Jin;Jang, Won-Hyuck
    • Korean Journal of Veterinary Service
    • /
    • v.30 no.2
    • /
    • pp.191-196
    • /
    • 2007
  • The slaughter process for cattle will inevitably transfer some bacteria onto the carcasses. The goal of food safety programs is to minimize and effectively remove this contamination. This study was attempted by the Verif $EYE^{TM}$ machine-vision technology that might be useful for reducing microbial indicator counts and could reduce the contamination chance of E coli O157:H7 and Salmonella spp on beef carcasses. For the evaluation of the effectiveness of the Verif $EYE^{TM}$ technology, 80 samples were examined by the inspection device over 15 days. On an examination of FDS-positive samples compared to negative controls from the same carcasses, aerobic plate counts were bigger than the negative control samples (5.26 vs 4.60 log). Enterobacteriaceae counts were greater on the positive samples than the corresponding negative control samples (2.07 vs 1.17log). There was a consistent correlation between samples detected by the Verif $EYE^{TM}$ system with detectable counts. For example, 100% of positive samples had detectable APC and 91.2% of positive samples had detectable TCC. Therefore, if areas detected as positive for contamination by the Verif $EYE^{TM}$ system were removed from the carcasses, significant sources of microbial contamination will be reduced for objective compliance with HACCP. This results suggest that the use of Verif $EYE^{TM}$ machine-vision technology might be useful for reducing microbial indicator counts (APC, TCC) and could help reduce the risk of presence of E coJi O157:H7 and Salmonella spp on Beef carcasses.

Design of a Stereoscopic Image Display System Using a LCD Shutter (LCD 셔터를 이용한 입체 영상 디스플레이 시스템의 설계)

  • Lee, Ki-Jong;Kim, Nam-Jin;Moon, Jeong-Sueng;Kim, Ju-Young;Park, Gwi-Tae;Seo, Sam-Joon
    • Proceedings of the KIEE Conference
    • /
    • 1998.11b
    • /
    • pp.511-513
    • /
    • 1998
  • This paper describes a full color stereoscopic video display system using a LCD shutter. Human apprehends the world with a natural stereo vision. The left eye sees through a slightly different perspective from the right eye; proposed vision system combines two images into a single image that has stereo depth. That is, when the left image is on the screen, the left shutter opens and the right shutter closes - and vice versa. The LCD shutter channels the left image to the left eye, and the right image to the right eye. The brain then fuses the stereo pair into a single high-resolution, flicker-free 3D image. The designed vision system is a real-time system that shows stereoscopic images without the loss of image information from video cameras.

  • PDF