• Title/Summary/Keyword: extreme cold condition

Search Result 23, Processing Time 0.026 seconds

Experimental Study on the Thermal Performance of a Printed Circuit Heat Exchanger in a Cryogenic Environment (극저온 환경의 인쇄기판형 열교환기 열적성능에 대한 실험적 연구)

  • Kim, Dong Ho;Na, Sang Jun;Kim, Young;Choi, Jun Seok;Yoon, Seok Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.8
    • /
    • pp.426-431
    • /
    • 2015
  • The advantages of a printed circuit heat exchanger (PCHE) are the compactness and efficiency derived from its heat-transfer characteristics; furthermore, a PCHE for which a diffusion bonding method was used during production can be applied to extreme environments such as a cryogenic condition. In this study, a micro-channel PCHE fabricated by diffusion bonding was investigated in a cryogenic environment regarding its thermal performance and the pressure drop. The test rig consists of an LN2 storage tank, vaporizers, heaters, and a cold box, whereby the vaporized cryogenic nitrogen flows in hot and cold streams. The overall heat-transfer coefficients were evaluated and compared with traditional correlations. Lastly, we suggested the modified heat-transfer correlations for a PCHE in a cryogenic condition.

Revisit the Cause of the Cold Surge in Jeju Island Accompanied by Heavy Snow in January 2016 (2016년 1월 폭설을 동반한 제주도 한파의 원인 재고찰)

  • Han, Kwang-Hee;Ku, Ho-Young;Bae, Hyo-Jun;Kim, Baek-Min
    • Atmosphere
    • /
    • v.32 no.3
    • /
    • pp.207-221
    • /
    • 2022
  • In Jeju, on January 23, 2016, a cold surge accompanied by heavy snowfall with the most significant amount of 12 cm was the highest record in 32 years. During this period, the temperature of 850 hPa in January was the lowest in 2016. Notably, in 2016, the average surface temperature of January on the Polar cap was the highest since 1991, and 500 hPa geopotential height also showed the highest value. With this condition, the polar vortex in the northern hemisphere meandered and expanded into the subtropics regionally, covering the Korean Peninsula with very high potential vorticity up to 7 Potential Vorticity Unit. As a result, the strong cold advection, mostly driven by a northerly wind, around the Korean Peninsula occurred at over 2𝜎. Previous studies have not addressed this extreme synoptic condition linked to polar vortex expansion due to the unprecedented Arctic warming. We suggest that the occurrence of a strong Ural blocking event after the abrupt warming of the Barents/Karas seas is a major cause of unusually strong cold advection. With a specified mesoscale model simulation with SST (Sea Surface Temperature), we also show that the warmer SST condition near the Korean Peninsula contributed to the heavy snowfall event on Jeju Island.

A Study on the Catecholamine under the Room Temperature and $5^{\circ}C$ Refrigerator Environment in Rat (실온과 $5^{\circ}C$ 냉장고 환경에서 흰쥐 Catecholamine 분비에 관한 연구)

  • Hong, Seyng-Eui;Yoon, Tai-Young;Kim, Hyung-Suk
    • Journal of Preventive Medicine and Public Health
    • /
    • v.20 no.2 s.22
    • /
    • pp.215-220
    • /
    • 1987
  • Under the extreme change of the environment, animals react physiologically to adapt to the stress and secrete catecholamines. Cold exposure is a kind of the environmental stress. Author tried to determine the amount of catecholamines in rat urine as a parameter of physiological response to cold stress. Urinary catecholamine was measured by using HPLC with fluorescence detector, cation exchange column prepacked with Bio·Rex 70 and ammonium pentaborate as catecholamine eluent. The amount of dopaminc in normal state rat urine was 42.0 ng, but under the low temperature of $5^{\circ}C$, the dopamine amount was increased to 221.25 ng/5 ml. Above findings are suggesting that catecholamine secretion, especially dopamine, increases in the stressful condition such as cold exposure.

  • PDF

Development of Dynamical Seasonal Prediction System for Northern Winter using the Cryospheric Condition of Late Autumn (가을철 빙권 조건을 활용한 겨울철 역학 계절 예측시스템의 개발)

  • Shim, Taehyoun;Jeong, Jee-Hoon;Kim, Baek-Min;Kim, Seong-Joong;Kim, Hyun-Kyung
    • Atmosphere
    • /
    • v.23 no.1
    • /
    • pp.73-83
    • /
    • 2013
  • In recent several years, East Asia, Europe and North America have suffered successive cold winters and a number of historical records on the extreme weathers are replaced with new record-breaking cold events. As a possible explanation, several studies suggested that cryospheric conditions of Northern Hemisphere (NH), i.e. Arctic sea-ice and snow cover over northern part of major continents, are changing significantly and now play an active role for modulating midlatitude atmospheric circulation patterns that could bring cold winters for some regions in midlatitude. In this study, a dynamical seasonal prediction system for NH winter is newly developed using the snow depth initialization technique and statistically predicted sea-ice boundary condition. Since the snow depth shows largest variability in October, entire period of October has been utilized as a training period for the land surface initialization and model land surface during the period is continuously forced by the observed daily atmospheric conditions and snow depths. A simple persistent anomaly decaying toward an averaged sea-ice condition has been used for the statistical prediction of sea-ice boundary conditions. The constructed dynamical prediction system has been tested for winter 2012/13 starting at November 1 using 16 different initial conditions and the results are discussed. Implications and a future direction for further development are also described.

The Literatural Study of True Heartache (진심통(眞心痛)에 관(關)한 문헌적(文獻的) 고찰(考察))

  • Jun, Chan-Yong;Jo, Ki-Ho;Lee, Won-Chol;金永錫, Yong-Seok;Bhae, Hyung-Sup;Lee, Kyung-Sup;Goo, Bon-Hong
    • The Journal of Internal Korean Medicine
    • /
    • v.11 no.1
    • /
    • pp.121-126
    • /
    • 1990
  • The true heartache is a condition of severe heartache corresponding to angina pectoris, as recorded from Hwang Jae Nai Kyung. According to the literatural study of true heartache, some results can be acquired, such as follows. 1. The site of the true Heartache, can be divided into two categories, first, its superficial and conscious area is the chest as same as the other heartache. But its inner lesion is the Heart-Meridian as others occupied at the Pericardium-Meridian in stead of the Heart-Meridian. 2. The etiological classification of true heartache, are Cold-evil, Heat-evil, Wind-evil, Blood stasis etc. But its major factor is Cold-evil, more than anything else. 3. The symptomatic signs of true heartache, consist of cyanotic change from hands and feet to phalanges; severe heartache pale complexion with cold breathing and its extreme state can manifestate unceased sweating called as Yang exhaustion.

  • PDF

PRELAUNCH THERMAL ANALYSIS OF KSLV-I PAYLOAD FAIRING

  • Choi Sang-Ho;Kim Seong-Lyong;Kim Insun
    • Bulletin of the Korean Space Science Society
    • /
    • 2004.10b
    • /
    • pp.356-359
    • /
    • 2004
  • Prelaunch thermal analysis of the KSLV (Korea Space Launch Vehicle)-I PLF (Payload Fairing) was performed to predict maximum/minimum liftoff temperatures and to evaluate of air conditioning performance. Prelaunch thermal analysis includes internal air conditioning effect, external convective heating/cooling, radiation exchange with the ground and sky, radiation between spacecraft and PLF, and solar radiation incident on PLF. Analysis was performed at two extreme conditions, hot day condition and cold day condition. The results showed that the maximum liftoff temperature was $53^{\circ}C$ and the minimum liftoff temperature was $-3.8^{\circ}C$. It was also found that conditioned air supplying, in $20{\pm}2^{\circ}C\;and\;1200\;m^3/hr$, is sufficient to keep the internal air in required temperature range.

  • PDF

Verification on Cold-Tolerance of Some Fruit Trees as Species for Urban Greening Plants

  • Lee, Jin-Hee;Oh, Hee-Young;Kwon, O-Man
    • Journal of Environmental Science International
    • /
    • v.26 no.10
    • /
    • pp.1155-1166
    • /
    • 2017
  • This study selected commonly known species of fruit trees, and re-selected the species that endure the stress of extreme cold weather and physiologically restore themselves to the previous state until the following year. Then we could go ahead to propose the species that were appropriate as urban greening plants in weather condition of any part of the country. To do this, we conducted an experiments for six species of fruit trees based on the preference of the general public and recommendation of the experts; Morus alba (English name: mulberries), Diospyros kaki (English name: Persimmon), Prunus persia (English name: Peach), Elaeagnus umbellata var. coreana (English name: Korean Autumn Olive), Malus domestica 'Alps Otome' (English name: Alps Otome), and Prunus mume (English name: Blue Plum). The experiment verifies whether the trees survive without any stress from the cold weather under the national climate conditions (one in the suburbs of Seoul: Yongin city, one in the central Chungcheong region: Daejeon city, and in the southern Gyeongsang region: Jinju city in Korea). The experiment lasted for a year from August 2016 to August 2017. The levels of electrolytic efflux, chlorophyll content, plant height, fresh weight, and dry weight were measured four times (on August of 2016, January, February, and August of 2017) for each tree planted bare ground outdoors. Results showed that Diospyros kaki, Prunus persia, and Malus domestica 'Alps Otome' were proven durable and resistant to winters of all three areas (one in the suburbs of Seoul: Yongin city, one in the central Chungcheong region: Daejeon city, and in the southern Gyeongsang region: Jinju city in Korea). Especially, the increase of chlorophyll content and the reduction of electrolytic efflux were noticeable in Prunus persia than in the other two species, proving itself as the most cold-tolerant among the six species used in the experiment. In addition, interpreting from the physiological restoration data of one-year span before and after getting through winterer, Prunus persia was proven to be the most cold-tolerant species.

Analysis of the Behavior Characteristics of Pile Foundations Responding to Ground Deformation (지반 변형 대응형 말뚝 기초의 거동 특성 분석)

  • Lee, Junwon;Shin, Sehee;Lee, Haklin;Kim, Dongwook;Lee, Kicheol
    • Journal of the Korean Geosynthetics Society
    • /
    • v.19 no.4
    • /
    • pp.21-32
    • /
    • 2020
  • As the global large-scale infrastructure construction market expands, the construction of civil engineering structures in extreme environments such as cold or hot regions is being planned or constructed. Accordingly, the construction of the pile foundation is essential to secure the bearing capacity of the upper structure, but there is a concern about loss of stability and function of the pile foundation due to the possibility of ground deformation in extreme cold and hot regions. Therefore, in this study, a new type of pile foundation is developed to respond with the deformation of the ground, and the ground deformation that can occur in extreme cold and hot region is largely divided into heaving and settlement. The new type of pile foundation is a form in which a cylinder capable of shrinkage and expansion is inserted inside the steel pipe pile, and the effect of the cylinder during the heaving and settlement process was analyzed numerically. As a result of the numerical analysis, the ground heaving caused excessive tensile stress of the pile, and the expansion condition of the cylinder shared the tensile stress acting on the pile and reduced the axial stress acting on the pile. Ground settlement increased the compressive stress of the pile due to the occurrence of negative skin friction. The cylinder must be positioned below the neutral point and behave in shrinkage for optimum efficiency. However, the amount and location of shrinkage and expansion of cylinder must comply with the allowable displacement range of the upper structure. It is judged that the design needs to be considered.

Experimental Study on Developing of Double Facade System dealing with the various climatic Conditions (다양한 기후조건에 대응하는 이중외피시스템 개발에 관한 실험적 연구)

  • Lee, Keon-ho;Kim, Hyeon-soo;Jang, Dae-hee;Moon, Soo-young
    • KIEAE Journal
    • /
    • v.5 no.2
    • /
    • pp.19-26
    • /
    • 2005
  • Every site has a different given geometrical and climatic condition, which influenced not only the lifestyle of the humanbeings but also the regional architecture. For example, on a cold region, the reduction of the energy loss is necessary, like an igloo, which has a littlest energy loss at hemisphere. Or on a warm region, the house must be protected thermally from the overheating at the sunshining. like a huge shading. An architectural interpretation in the (extreme) moderate climate, like Korea, has always tried to satisfy the both opposite demands simultaneously. A facade, which divides out- and inside, has an ideal position to lead the regulated regional climatic conditions into the room. The Double Facade System(DFS) is well known as an innovative solution in the european countries, like Germany. It provides an reasonable alternative, which can achieve these goals at the same time. A Double Facade System provides an effective sunshade, which means a cooling energy reduction at the warm season. In addition, it enables a natural ventilation at the cold season with the preheating at the system as well as spring and autumn. An ordinary Single Facade System with a inside or outside sun blind provides a solution just for a specified season, like a summer or winter. But the Double Facade System can deal with the various climatic conditions in the moderate climate.

Temperature and humidity effects on behavior of grouts

  • Farzampour, Alireza
    • Advances in concrete construction
    • /
    • v.5 no.6
    • /
    • pp.659-669
    • /
    • 2017
  • Grouts compared to other material sources, could be highly sensitive to cold weather conditions, especially when the compressive strength is the matter of concern. Grout as one the substantial residential building material used in retaining walls, rebar fixation, sidewalks is in need of deeper investigation, especially in extreme weather condition. In this article, compressive strength development of four different commercial grouts at three temperatures and two humidity rates are evaluated. This experiment is aimed to assess the grout strength development over time and overall compressive strength when the material is cast at low temperatures. Results represent that reducing the curing temperature about 15 degrees could result in 20% reduction in ultimate strength; however, decreasing the humidity percentage by 50% could lead to 10% reduction in ultimate strength. The maturity test results represented the effect of various temperatures and humidity rates on maturity of the grouts. Additionally, the freeze-thaw cycle's effect on the grouts is conducted to investigate the durability factor. The results show that the lower temperatures could be significantly influential on the behavior of grouts compared to lower humidity rates. It is indicated that the maturity test could not be valid and precise in harsh temperature conditions.