• Title/Summary/Keyword: extraction resin

Search Result 155, Processing Time 0.03 seconds

A SURVEY OF THE TREATMENT IN FREE DENTAL CLINIC (치과 자원봉사 기관에서 시행한 장애인 치과 치료에 대한 통계)

  • Sohn, Mi-Yeon;Park, Jae-Hong;Choi, Sung-Chul;Kim, Kwang-Chul
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.5 no.2
    • /
    • pp.87-91
    • /
    • 2009
  • The purpose of this study were to investigate the chief complain and dental treatment needs in handicapped patient. This study examines treatment records of 1025 patients in free dental clinic for handicapped patients during 10 years from 1999 to 2008. The results were as follows : 5.8 average visit per patient; mean patient age was 25; 544 patients was younger than 20. Handicapped patients classified according to types of disability. Crippled disorder were 19.1%, brain disorder were 4.5%, visual disorder were 3.1%, auditory disorder were 4.1%, speech disorder were 0.9%, mental retardation were 67.1%, and developmental disorder were 25.1%. Performed treatments were 322 scaling, 13 fluoride varnish, 727 preventive resin restoration, 1296 resin restoration, 600 amalgam restoration, 46 GI restoration, 612 extraction, 289 pulp treatment of primary teeth, 75 pulp treatment of permanent teeth and 138 stainless steel crown restoration. Many handicapped patients have some difficulty to dental treatment. They have limited access to dental care, which is compounded by a shortage of skilled dental professionals who are willing to treat these population and financial problems.

  • PDF

A COMPARATIVE ANALYSIS OF THE ACCURACY OF IMPLANT IMPRESSION TECHNIQUES BY USING STRAIN GAUGE (Strain gauge를 사용한 임플랜트 인상법의 정확도 비교)

  • Han, Eu-Taek;Kim, Yung-Soo;Kim, Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.3
    • /
    • pp.539-549
    • /
    • 1995
  • The purpose of this study was to determine the accuracy of 3 implant impression methods by using strain gauge. The models used for this study were partially edentulous mandibular acrylic resin casts Model A, with two abutment analogs in #46,47 extraction site, represented two implant parallel to to the adjacent natural tooth. Model B represent an anterior implant parallel to the adjacene natural tooth and a posterior implant exhibiting a 15-degree lingual inclination. Master framework were fabricated on the master model, and 3 strain gauges were attached to a master framwork to determine the passivity of fit of the framework to sample casts made by the three impression techniques. The master framework was attached to each sample cast with gold screws, which were tightened with the torque driver to ensure a consistent toque application of 10 Ncm. Universal Digital Measuring System UCAM-5BT was used for strain measuring. Impression techniques studid were : 1. unsplinted tapered impression coping, polyvinyl siloxane, stock tray 2. unsplinted squared impression coping, polyether, custom tray 3. squared impression coping splinted with Duralay resin, polyether, custom tray Through analysis on data from this study, the following conclusions were obtained. 1. There were no statistically significant differences between the mean strain recorded from the sample casts made with the tree impression. But only strain values of model A(parallel group) Y-axis was signifcantly differed between Technique 1 and 3(P<0.05). 2. There was no statistically significant difference between model A(parallel group) and model B(15-degree divergent group).

  • PDF

Separation of Radiostrontium from Environmental Sample Using Strontim Selective Chromatographic Resin$(Sr.\;Spec^{TM})$ (스트론튬 선택적이온교환수지$(Sr.\;Spec^{TM})$를 이용한 환경시료중의 방사성 스트론튬의 분리)

  • Hong, Kwang-Hee;Lee, Chang-Woo;Choi, Yong-Ho;Lee, Myung-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.1
    • /
    • pp.1-7
    • /
    • 1995
  • Strontium selective chromatographic material $(Sr-Spec^{TM})$ was investigated for separation of radiostrontium from environmental soil and water sample. This chromatographic material has great capacity of binding of strontium ion in nitric acid media, and has selectivity to permit the separation of stontium from bulk amount of calcium. But the extraction of strontium was reduced by the other interfering ions such as K and Ba. So, in order to apply this material to the soil sample, prior removal treatment of K and Ba was needed. But the Sr-Spec material could provides simple and effective methods for the separation and removal of radiostrontium from liquid sample.

  • PDF

Enrichment of Chromium(Ⅵ) by Macrorecticular DPC Resin (큰 그물 구조-DPC 수지에 의한 Cr(Ⅵ)의 농축)

  • In Hwa Woo;Tong Oh Seo;Kyu Ja Whang;Yong Keun Lee
    • Journal of the Korean Chemical Society
    • /
    • v.27 no.5
    • /
    • pp.345-352
    • /
    • 1983
  • Using a column of macrorecticular gel beads impregnated with alcohol solution of diphenylcarbarzide (DPC), the enrichment of Cr(Ⅵ) ion in 0.1M sulfuric acid was investigated. The column performance was compared with respect to the types of solid support such as Amberlite XAD and Diaion HP. Diaion HP-20 was found to be most suitable for this purpose. The break through point was increased when increasing the amount of DPC absorbed in the resin and the concentrated sample solution showed higher break through capacity than the dilute one. The extraction of Cr(Ⅵ) was not affected by the presence of 100 ppm Fe(Ⅲ) which amounted to ten times of 10 ppm Cr(Ⅵ) and the presence of other metal ions which amounted to 100 times of 10 ppm Cr(Ⅵ). Because the used gel particles were effectively regenerated with methanol, they were able to be used repeatedly.

  • PDF

Determination of trace actinide (Am, Pu, Th, U) using alpha spectrometry and neutron activation analysis (알파분광법과 중성자방사화분석법에 의한 극미량의 악티늄계원소 (Am, Pu, Th, U)분석연구)

  • Yoon, Yoon Yeol;Lee, Kil Yong;Cho, Soo Young;Kim, Yongjai;Lee, Myong Ho
    • Analytical Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.302-307
    • /
    • 2004
  • Determination of actinides in the environmental sample requires separation of each element. This procedure is tedious and time consuming. And also, the detection limits of some nuclides using alpha spectrometry are rather higher. To overcome the lower detection limit and complicated separation procedure, a simple analytical technique for the determination of actinide isotopes in the environmental samples was developed and applied to IAEA and NIST reference sediment samples. For the separation of actinides from matrix, anion exchange resin and TRU-spec extraction chromatography resin were used and chemical yields were obtained using natural uranium, thorium, $^{242}Pu$ and $^{243}Am$ tracers. For overcoming the higher detection limits of U and Th in alpha spectrometry, neutron activation analysis was applied. Using combined method, the detection limit was increased about 10 times. The activity values of each isotope were consistent with the reference values reported by IAEA and NIST.

Preparation of Hot Water Extracts of Dandelion Leaves to Increase Anti-inflammatory Activity (항염증 활성이 증진된 민들레 잎의 열수 추출물 제조조건 설정)

  • Koh, Yoon-Jeoung;Park, Yong-Kon;Kim, Yoon-Sook;Cha, Dong-Soo;Choi, Hee-Don
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.3
    • /
    • pp.391-395
    • /
    • 2009
  • To materialize anti-inflammatory compounds from dandelion leaves, we studied optimal conditions of hot water extraction and concentration. We investigated the properties of extracts on various temperatures between 60 and $90^{\circ}C$. Extraction yields at $60^{\circ}C$ were the highest at $39.2{\pm}1.3%$ and flavonoid contents were increased by heating. However, anti-inflammatory activities were remarkably decreased by increasing temperature. According to the results that the highest anti-inflammatory activities of water extract were demonstrated at $60^{\circ}C$, cell wall degrading enzyme treatment was carried out to increase extraction yield of anti-inflammatory compounds. The enzyme treatment resulted in increased yields and flavonoids from dandelion leaves of 1.5-fold and anti-inflammatory activities were not decreased. Also, column chromatography was used for concentration of anti-inflammatory compounds from extract of dandelion leaves treated with enzyme. Anti-inflammatory activities of adsorbed compounds on Amberlite XAD-2 and Sepabeads SP-850 were significantly increased. However, yields of adsorbed compounds were increased over two-folds on Sepabeads SP-850 compared to Amberlite XAD-2. Thus Sepabeads SP-850 was more effective than Amberlite XAD-2 to concentrate the anti-inflammatory compounds of dandelion leaves.

Remediation for Gasoline Contaminated Soils with SVE (soil vapor extraction) Including a Post-treatment System of Extraction Gases (배출가스의 후처리 공정을 포함한 토양증기추출법을 이용한 가솔린 오염 토양 복원)

  • 이민희;강현민;이병헌;빈정인
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.2
    • /
    • pp.28-40
    • /
    • 2004
  • Box experiments were performed to evaluate the removal efficiency of SVE (soil vapor extraction) for gasoline in soil. An activated carbon sorption tower and a biofilter were operated as post-treatment processes to remove VOCs extracted from extraction wells of SVE. An acrylic resin box (65 cm${\times}$20 cm${\times}$30 cm) was used to make artificial soil layers and two injection wells and one extraction well were built for SVE process in the box. Gases from extraction wells flew into the activated carbon sorption tower or the biofilter. Gasoline concentrations of VOCs emitted from the extraction well were compared with those after post treatments. More than 92% of initial gasoline mass in soil were removed by SVE within few days, suggesting that SVE is very available to remove VOCs from contaminated soils. To treat VOCs from extraction wells of SVE, an activated carbon sorption tower and a biofilter were attached to SVE process and their gasoline removal efficiencies were measured. These post treatment systems lowered gasoline concentrations to below 1.0 ppm within few days. Average remediation efficiency was 98% of gasoline for the activated carbon sorption tower and 84.1% for the biofilter. The maximum removal capacity of a biofilter was 10.7 g/L/hr, which was ten times higher than general biofilter removal capacity. Results from the study suggest that the activated carbon sorption tower and the biofilter would be available for the post treatment process to remove VOCs generated from SVE process.

CONSERVATIVE TREATMENT OF INTRA-ALVEOLAR ROOT FRACTURE OF PRIMARY INCISORS USING RESIN WIRE SPLINT : CASE REPORT (레진 강선 고정을 이용한 유전치 치근 파절의 보존적 치료 : 증례 보고)

  • Jung, Ji Hyun;Park, Jae-Hong;Kim, Kwang Chul;Choi, Yeong Chul;Choi, Sung Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.40 no.1
    • /
    • pp.53-59
    • /
    • 2013
  • In an intra-alveolar root fracture (IARF) of a primary tooth with severe mobility and displacement, extraction and periodic-follow-up is the choice of recommended treatments because of the fear of aspiration of the mobile tooth and the possibility of damage in the permanent succeeding tooth. However, repositioning and splinting are presented as a fresh proposal recently. In case of extracting a primary incisor, many problems occur; esthetic problems; functional problems such as pronunciation and mastication; space loss; and psychological and social problems. Therefore, the best treatment is conservation of the primary tooth. The aim of this report was to suggest the conservative treatment of an Intra-alveolar root fracture of the primary central incisors with severe mobility and displacement based on two cases that describe the diagnoses, treatments and follow-ups (mean period: 27-month). All cases have been treated by reduction and immobilization by resin wire splint (RWS) (mean period: 6-week). Both cases were followed up until the successors were erupted. There have been no complications such as pain, pulp necrosis, periapical lesion, displacement of permanent tooth germ, eruption disturbance and etc.

Determination of Synthetic Food Colours by HPLC with Photodiode Array Detector (HPLC를 이용한 타르색소의 분리정량)

  • Yang, Ho-Chul;Heo, Nam-Chil
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.30-35
    • /
    • 1999
  • A simple, rapid, efficient method is for extraction of 13 synthetic water-soluble food colours (Tartrazine, Amarnth, Indigo carmine, New coccine, Sunset yellow FCF, Allura red AC, Eosine, Fast Green FCF, Brilliant Blue FCF, Erythrosine, Acid red, phloxine, Rose Bengal) by polyamide resin and for their quantitative by high performance liquid chromatography (HPLC). Colours (coal-tar dyes) were extracted with polyamide resin and then determinated by HPLC. The HPLC conditions using a reverse phase partition type column $(Nova-pak\;C_{18})$, photodiode array (PDA) detector and 1% Ammonium acetate / 60% acetonitrile in water as eluent, were acceptable for various kinds of colorants. By the use of the proposed method, a survey of coal-tar dyes was carried out on 20 samples and that were detected $4.76{\sim}133.47\;ppm$.

  • PDF

Preconcentration and Determination of Fe(III) from Water and Food Samples by Newly Synthesized Chelating Reagent Impregnated Amberlite XAD-16 Resin

  • Tokahoglu, Serife;Ergun, Hasan;Cukurovah, Alaaddin
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.7
    • /
    • pp.1976-1980
    • /
    • 2010
  • A simple and reliable method has been developed to selectively separate and concentrate trace amounts of Fe(III) ions from water and food samples by using flame atomic absorption spectrometry. A new reagent, 5-hydroxy-4-ethyl-5,6-di-pyridin-2-yl-4,5-dihydro-2H-[1,2,4] triazine-3-thione, was synthesized and characterized by using FT-IR spectroscopy and elemental analysis. Effects of pH, concentration and volume of elution solution, sample flow rate, sample volume and interfering ions on the recovery of Fe(III) were investigated. The optimum pH was found to be 5. Eluent for quantitative elution was 10 mL of 2 M HCl. The preconcentration factor of the method, detection limit (3s/b, ${\mu}gL^{-1}$) and relative standard deviation values were found to be 25, 4.59 and 1%, respectively. In order to verify the accuracy of the method, two certified reference materials (TMDA 54.4 lake water and SRM 1568a rice flour) were analyzed. The results obtained were in good agreement with the certified values. The method was successfully applied to the determination of Fe(III) ions in water and food samples.