• 제목/요약/키워드: extinguish

검색결과 132건 처리시간 0.026초

3petal spiral type vacuum interrupter에서 가동접점전극과 고정접점전극간의 마주보는 각도의 변화가 아크구동력에 미치는 영향 (Influence of twisting angle between fixed contact and movable contact on arc driving force in 3petal spiral type vacuum interrupter)

  • 김병철;윤재훈;이승수;강성화;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.480-480
    • /
    • 2008
  • Vacuum circuit breaker(VCB) is now emerging as an alternative of gas circuit breaker(GCB) which uses SF6 gas as insulating material whose dielectric strength is outstanding. But we have to reduce SF6 gas because SF6 gas is one of greenhouse gas and efforts to reduce greenhouse gas are now trend of the world. Therefore, we can say VCB is the optimal alternative of GCB because vacuum is environmentally friendly. The vacuum interrupter is the core part of VCB to interrupt arcing current. There are mainly two methods to extinguish arc. One is radial magnetic field (RMF) method and the other is axial magnetic field (AMF) method. We deals with RMF method in this paper. Compared with AMP, RMF arc quenching method has different principle to extinguish arc. In case of RMF method, pinch effect is much larger than AMF method. Because of pinch effect RMF type contact electrodes have the single large spot which is severly damaged and melted while AMF type contact electrodes have small and multiple spots which are slightly damaged and melted. To prevent contact electrode being damaged and melted from high temperature-arc, RMF method uses Lorentz force to move arc. In this paper we calculated and compared the arc driving force of two cases and we analyzed the force acting on each part of arc by means of commercial finite element method software Maxwell 3D. They have 3petals and we considered two cases. One is the case when fixed(upper) and movable(lower) contacts are in mirror arrangement (Case 1). The other is the case when one of two contacts (movable contact) is revolved at maximum angle as possible as it can be (Case 2). And at each case above, we analyzed arc driving force at two positions, position 1 is the closest to the center of contact and position 2 is near the edge of petal on fixed contact. As a result we could find that Case 2 generated stronger arc driving force than Case 1 at position 1. But at position 2 Case 1 generated stronger arc driving force than Case 2. This simulation method can contribute to optimizing spiral-type electrode designs in a view of arc driving force.

  • PDF

소방공무원 건강장해 유해인자에 대한 실증연구 -화재진압대원, 구조대원, 구급대원의 인식조사를 중심으로- (An Empirical Study on Firefighters' Health Hazard Factors -Focused on Fire Fighters, Rescue Workers and Emergency Medical Technicians Perception in Busan Fire Fighters-)

  • 권설아;이민규;박상호;김다영;류상일
    • 한국콘텐츠학회논문지
    • /
    • 제19권3호
    • /
    • pp.520-529
    • /
    • 2019
  • 이 연구는 부산시 소방공무원들의 건강장애 유해인자에 대해서 실증적으로 살펴봄으로써 향후 소방공무원들의 건강관리에 기초자료를 제공하고자 하였다. 결과적으로, 우선, 화재진압대원의 유해인자를 보면, 아무래도 화재현장에서 근무하기 때문에 업무특성을 반영하여 화재 시 발생하는 유해화학물질의 위험성을 가장 심각하게 인식하고 있다는 것을 확인할 수 있었고, 다음으로 화재 진압시에 추락위험을 높이 인식하고 있다는 것을 확인할 수 있었다. 다음, 구조대원의 유해인자에서는 구조대원이 화재 현장이나 각종 사고현장에서 요구조자를 구조하는 임무를 수행하기 때문에 현장 유해화학물질 위험성을 가장 높게 인식하고 있었고, 또한 구조현장에서의 추락위험을 두 번째로 높게 인식하고 있었는데 이는 업무 특성이 반영된 결과라고 볼 수 있다. 또한, 구급대원의 유해인자를 보면, 구급대원의 교대근무의 위험성을 가장 높게 인식하고 있었다. 이는 기존 연구에서 교대근무가 건강에 유해하다는 것과 일맥상통하는 대목이다. 다음으로, 환자이송 과부하가 큰 유해요소로 꼽았다는 것은 그만큼 구급업무의 특성상 많은 이송환자들이 많아짐으로 인해서 각종 2차 사고가 발생할 가능성이 있기 때문으로 사료되며, 구급현장 이송 중에는 빠르게 구급차량을 이동시켜야하기 때문에 교통사고 유발 가능성도 유해요소로 인식되고 있다는 것을 알 수 있다. 마지막, 유해인자 인식 비교에서는 구조대원이 가장 위험하다고 인식하고 있는 것을 알 수 있다. 이는 업무 특성과도 연관되는데, 구조대원의 경우가 화재 등 각종 위험현장과 가장 근접하게 활동을 하고 있기 때문으로 사료된다.

양방향 통신이 가능한 자동화재탐지설비(P형 1급 수신기)의 설계 및 동작특성에 관한 연구 (A Study on Design and Operation Performance of Automatic Fire Detection Equipment (P-type One-class Receiver) by Bidirectional Communication)

  • 이봉섭;곽동걸;정도영;천동진
    • 전기학회논문지
    • /
    • 제61권2호
    • /
    • pp.347-353
    • /
    • 2012
  • In this paper, authors will develop the quick and precise remote controller of automatic fire detection equipment (P-type one-class receiver) based on information communication technology (IT). The remote controller detects the fire and disaster in the building automatically and quickly and then activates the facilities to extinguish the fire and disaster, monitoring such situation in a real time through wire-wireless communication network. The proposed remote controller is applied a programmable logic device (PLD) micom. of one-chip type which is small size and lightweight and also has highly sensitive-precise reliabilities. The one-chip type PLD micom. analyzes digital signals from sensors, then activates fire extinguishing facilities for alarm and rapid suppression in a case of fire and disaster. The detected data is also transferred to a remote situation room through wire-wireless network of RS232c and bluetooth communication, and then the situation room sends an emergency alarm signal. The automatic fire detection equipment (AFDE) based on IT will minimize the life and wealth loss while prevents fire and disaster.

"계림고본(桂林古本)" 상한논판본(傷寒論板本)의 처방구성에 대한 분석연구 (The statical analysis of GuiLinGuBon prescriptoin)

  • 서영배;강한은
    • 혜화의학회지
    • /
    • 제21권1호
    • /
    • pp.65-78
    • /
    • 2012
  • Found on the 19th century, GuiLinGuBon can have more several unique features than the other extinguish editions. GuiLinGuBon has been Receiving attention, because it contains both and 's contents, as well as it consistt of 16 books to the same as the preperce, and then it analyzed the chapter on Wending Disease(溫病) and Liuyin Disease(六淫病) in detail which is not written in current book, and gives several clues to solve many questions that caused the controversy. This thesis is the study the GuiLinGuBon on the overall composition and the prescriptions for the overall analysis to book configuration, herbs configuration, 8 method(八法) according to the prescribed frequency, SinNongBonChoGyong(神农本草经) according to the herbs of the SamPum(三品) classification and statistical processing GuiLinGuBon the specific features were analyzed.

선박화재 적용 단백포 소화약제의 안정제에 따른 소화특성 (Characteristics of Protein Foam Agent by Stabilizer on the Ship Fire Extinguishment)

  • 이응우;신창섭
    • 한국안전학회지
    • /
    • 제30권4호
    • /
    • pp.79-85
    • /
    • 2015
  • Onboard fire extinguishing system is important to protect cargo and human lives and every oil tanker has foam type fire extinguishing system. Because of environmental problem, agent which contains materials such as Perfluorinated compounds are regulated and the development of the environmental friendly agent is required. The protein foam has less environmental pollution problem and has an excellent fire extinguish performance to oil fire. In the research, bivalency metal salts were added as stabilizer to increase fire resistance and stability of the foam. Ferrous sulfate, Iron chloride and Nickel chloride were used and to adjust to vessel, sea water was applied. As a stabilizer increased, the expansion ratio was raised. However 25% drainage time was decreased over 2.0 wt.% which is knowable that the foam brokes easily. The amount of generated foam was measured to check fluidity of foam and it appeared that when $FeSO_4$ 1.2 wt.% was added, the amount of generated foam reached large and also the 25% drainage time was high. To evaluate the fire extinguishing performance for oil fire, the small scale oil fire test was executed. When $FeSO_4$ 1.2 wt.% was added, fire extinguishing time was in its shortest which informs fluidity of foam and stability are important factors on fire extinguishing efficiency.

중국 텐진항 폭발사고 원인과 관련된 폭발 에너지 분석 (Analysis of Explosion Energy related to the Cause of Tianjin Explosion Accident in China)

  • 권상기;김하영
    • 화약ㆍ발파
    • /
    • 제34권1호
    • /
    • pp.1-10
    • /
    • 2016
  • 2015년 8월 12일 중국 텐진항에서는 두 번의 대규모 폭발이 발생하였다. 두 번의 폭발은 TNT 3톤, TNT 21톤 규모로 추정되었다. 현재까지 폭발의 정확한 원인은 공표되지 않고 있으며 원인에 대한 몇 가지 추정이 제시되고 있다. 그중 하나는 화재진압을 위해 뿌려진 물과 탄산칼슘의 화학반응에 의해 폭발성 아세틸렌 가스가 발생하고 이 가스의 폭발이 800톤의 질산암모늄의 폭발을 야기했을 것이라는 것이다. 본 연구에서는 이러한 폭발 시나리오에 대한 폭발에너지 분석을 통해 화학적 반응에 의해 텐진항 폭발 사고와 같은 대규모 폭발이 발생 가능한지를 평가하였다.

샌드위치 패널의 화재확대 방지시스템 개발을 위한 실험적 연구 (An Experiment Study for Flame Spread Prevention System of Snadwich Panels)

  • 신현준;인기호;유용호
    • 설비공학논문집
    • /
    • 제27권6호
    • /
    • pp.307-312
    • /
    • 2015
  • The sandwich panel is commonly used domestically because it's less costly and easier to handle. But fires have frequently occurred in buildings employing sandwich panels, such as the fires in Eecheon cold storage and in Gwangju Pyungdong industrial zone. Sandwich panels with steel plates on their surface prevent fire water from penetrating to the fire source, which makes it difficult to extinguish a fire in a timely manner. Toxic gas generated from some insulation material leads to serious loss of life and property. This study is intended to develop an extinguishing system for sandwich panels, thereby reducing the fire risk. Fire water and volume were determined in the wake of the study on the structure of a sandwich panel extinguishing system, and improvement and testing of the fire characteristics of the sandwich panel. Based on such study and test, a fire model test was conducted. Consequently, the sandwich panel with extinguishing system was proven to have a reduced fire risk, compared to traditional or fire retardant panels.

USN 화재방재 시스템을 위한 보안 통신 구현 및 실험 (Security Communication Implementation and Experiments for USN Fire Prevention System)

  • 김영혁;임일권;이재광
    • 컴퓨터교육학회논문지
    • /
    • 제13권6호
    • /
    • pp.99-104
    • /
    • 2010
  • USN 화재방재 시스템은 온도, 습도, 조도, 가속도, CO2 등의 다양한 센서로부터 얻는 데이터를 이용해 관리자에게 전달하고, 화재를 판별하는 화재 판별 알고리즘을 이용하여 소화설비를 동작시키는 지능적인 시스템이다. USN 화재방재 시스템은 센서의 데이터에 전적으로 의지하여 동작함으로 본 논문에서는 분산된 각각의 센서 데이터들을 임베디드 시스템 환경에서 효율적이고 안전하게 수집, 전달하기 위한 모델을 제안한다. 패킷의 구성과 패키징은 저 전력 소모를 위해 최대한 가볍고 빠른 처리 과정을 거치게 설계하였으며, 현재 나와 있는 암호화 알고리즘 중 DES, 3DES, AES, HIGHT를 각각 적용, 빠른 암복호화에 목표를 두어 최종적으로 국내에서 제안한 표준 암호화 알고리즘인 HIGHT가 잦은 센싱 시간을 요구하는 화재방재 시스템에 적합함을 확인하였다.

  • PDF

랙크식 물류창고의 스프링클러설비 소화성능에 관한 실험연구 (Experimental Study on the Suppression Performance of Sprinkler Systems in Rack-type Warehouses)

  • 최기옥;최돈묵
    • 한국화재소방학회논문지
    • /
    • 제33권3호
    • /
    • pp.44-50
    • /
    • 2019
  • 랙크식 창고 내에는 화재하중이 높은 물품이 수직으로 조밀하게 적재되어 있어 창고의 내부에서 화재가 발생되는 경우 현재의 스프링클러설비에 의해 유효하게 소화되기 어렵다. 이에 본 연구에서는 실물 규모의 랙크 구조물을 구축하고, 구조물 내부의 스프링클러헤드 종류 및 배치에 따른 화재실험을 통해 스프링클러설비에 의한 소화유효성을 확인하였다. 본 연구를 통하여 랙크식 창고의 내부의 화재를 유효하게 진압하기 위해서는 방수량 115 LPM 이상의 스프링클러헤드를 사용해야 하며, 동 스프링클러헤드를 높이 기준이 아닌 랙크 각 단마다 설치해야하고, 각 단의 가연물더미의 대각선 모서리 위치에 설치될 필요가 있다는 것을 알 수 있었다.

소방로봇 원격제어를 위한 무선패킷 디지털 데이터통신 및 아날로그 영상통신 기법 (Wireless Digital Packet Communication and Analog Image Communication Systems for Fire Fighting Robot)

  • 정직한;김병욱;박상욱;박동조;박정현
    • 제어로봇시스템학회논문지
    • /
    • 제13권2호
    • /
    • pp.121-127
    • /
    • 2007
  • Frequent occurrences of a fire cause tremendous loss of human lives and their property. Recently, in order to cope with such catastrophic accidents, researches on fire-fighting robots are carried out in developed countries. Under the dangerous situations, it is sometimes impossible for fire-fighting men to access the firing place because of explosive materials, smoke, high temperature and so on. In such an environment, fire-fighting robots can be useful to extinguish the fire. It is usually very dangerous place where fire-fighting robots operate. Hence, these robots should be controlled by remote users who are for away from the firing place exploiting remote communication systems. This paper considers the communication systems between fire-fighting robots and remote users. The communication systems consist of two parts; digital packet communication systems and analog image communication systems. Digital packet communication systems transfer data packets in order to control fire-fighting robots and to check the state of the fire-fighting robots. Remote users watch the video around the fire-fighting robots by exploiting the analog image communication systems. In the future, the more prosperous the commercial communication network systems will be, the more evolved the communication systems for fire-fighting robots are.