본 논문은 전기제품 내에 안전장치로 사용되는 퓨즈를 이용한 전기화재의 원인분석에 관한 연구이다. 시료는 유리관퓨즈(정격 15 A, $5{\times}20mm$)와 온도퓨즈(정격 10 A, $72^{\circ}C$)를 사용하였다. 전기화재의 주요원인인 단락 및 과부하 그리고 외부화염을 인위적으로 가하여 소손된 퓨즈의 특성을 비교 분석하였다. 실험결과 유리관퓨즈의 경우 소손된 퓨즈의 외형 및 표면 그리고 조직분석에서 서로 다른 특징들을 확인할 수 있었다. 온도퓨즈의 경우 외부화염실험의 경우에서만 소손된 퓨즈의 외형 및 가동접점의 표면 그리고 조직분석에서 뚜렷한 특징이 나타났다.
Due to the recent quantum leaps forward in bio-, nano-, and information-technologies (BT, NT and IT), the precisionization and miniaturization of mechanical and electrical components are in high demand. In particular, the ITrelated equipments that take a great part in our domestic industry are in the area requiring high precision technologies. As a consequence, the researches on the development vibration isolation systems that diminish external disturbance or internal vibration are highly required. Among the components comprising the vibration isolation system, air spring has become on a focal point for the researchers due to its merits. This air spring is able to support heavy loads, keep a low natural frequency despite of having a lower value of stiffness, and control the performance of vibration isolation. However, sometimes the sole use of air spring is in demand due to some economic reasons. Under this circumstance, the damping effect of sole air spring may not enough to reduce sufficient amount of vibration. In this study, the air spring mount system connecting with an external chamber is proposed to increase or control the damping effect. To investigate its damping mechanism, the thermal and dynamic behaviors of the system is examined through a theoretical modeling approach in this part of research. In this approach, thermomechanical and Helmholtz resonator type models are to be employed for the air spring/external chambers and connecting tube system, respectively. The frequency response functions (FRFs) derived from the modeling effort are evaluated with physical parametric values and the effects of connecting tube length on these FRFs are identified through computer simulations.
In order to research the flow in the thin wall compliant tube, this present study is attempt to measure the cross sectional area according to change of external pressure and flow by ultrasonic method different from willy used impedance technique for flow analysis about one dimensional Steads flow. The experimental results are as follows. 1) Measurement of cross sectional area ratio by ultrasonic method by comparison with experimental results of impedance technique & theoretical results were well consent. 2) Pressure difference of upstream and down stream is alwap's maximum range at 0.4 < $\alpha$ <0.5, and have no connection with changing external pressure. 3) when the external pressure is fixed and resistance is varied, Self excited oscillation occurs in the region at 0.5 < $\alpha$ <0.6, and oscillation disappear almost at R2>=1.2
한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
/
pp.367-370
/
2007
An EEFL with the sodium free alumino-silicate glass of high K and low $tan{\delta}$, has been investigated. As compared with borosilicate and the soda-lime EEFLs, the luminous efficiency as well as the pinhole stability of new EEFLs improves remarkably without blackening of $NaHg_2$.
Kim, Hyeong-Joo;Won, Myoung-Soo;Park, Tae-Woong;Choi, Min-Jun;Jamin, Jay C.
Structural Engineering and Mechanics
/
제55권2호
/
pp.349-364
/
2015
Analytical solutions for modeling geotextile tubes during the filling process and approximation method to determine the densified tube shape are reviewed. The geotextile tube filling analysis is based on Plaut & Suherman's two-dimensional solution for geotextile tubes having a weightless and frictionless inextensible membrane resting on a rigid horizontal foundation subjected to internal and external hydrostatic pressures. The approximation for the densified tube shape developed by Leshchinsky et al. was adopted. A modified method for approximating the densified tube shape based on an areal-strain deformation analysis is introduced. Design diagrams useful for approximating geotextile tube measurements in the design process are provided.
최근 기둥의 구속효과에 대한 연구가 많이 연구되어지고 있다. 주로 철근 콘크리트 기둥과 CFT(Concrete Filled Tube)기둥과 같이 중실 기둥에 대한 연구로 한정되어 있는 반면 중공 기둥에 대한 구속효과 연구가 매우 미비한 실정이다. 중공 기둥의 외부 구속력에 대한 연구가 주로 연구되고 있고 내부 구속력을 외부 구속력과 동일하게 가정하고 구속 콘크리트의 구속효과를 평가하고 있다. 본 연구에서는 중공 CFT 기둥에 내부 튜브를 삽입하여 구속 콘크리트 3축 구속 상태로 놓이게 하여 연성 및 강도를 상승 시킨 내부 구속 중공 CFT 기둥(Internally Confined Hollow CFT, ICH CFT)의 최적 구속메커니즘을 도출하기 위한 연구를 하였다. 내부튜브 두께, 중공비, 기둥의 직경, 콘크리트와 외부튜브의 휨강성비를 매개변수로 삼아 범용 FEM 프로그램으로 비선형 해석 연구를 수행하여 최적 내부 구속력 도출을 통하여 수정 파괴 조건식을 제안하였다. 수정 파괴 조건식은 최적 내부 튜브의 두께를 산정하여 기둥이 경제성을 확보하도록 하였다.
본 연구는 영상의학과에 내원한 족부환자를 대상으로 족부 X선 검사 시 주상골(navicular)의 관찰이 어려운 점을 바탕으로 환자의 position과 X선관 각도의 변화를 주어 어떠한 position과 X선관 각도에서 주상골의 관찰이 용이한지를 알아보고자 하였다. 주상골 관찰을 위해 실험대상자의 position은 Foot AP, internal oblique, external Oblique position의 세 가지로 하였다. T-F angle(Tibia-Foot angle)은 $90^{\circ}$와 $135^{\circ}$로 정의하였고, X선관 각도는 $0^{\circ}$, $5^{\circ}$, $10^{\circ}$, $15^{\circ}$, $20^{\circ}$, $25^{\circ}$로 정의하여 실험한 후 획득한 영상을 비교 평가하였다. 실험결과, Foot AP position에서 T-F angle이 $90^{\circ}$인 경우 X선관 각도가 $15^{\circ}$일 때 설상골과 주상골의 겹침 정도는 3%이었고 블라인드 테스트 결과는 4.89점으로 골절의 판독 용이성이 가장 높았으며, T-F angle이 $135^{\circ}$경우에는 X선관 각도가 $15^{\circ}$일 때 설상골과 주상골의 겹침 정도는 5%이었고 블라인드 테스트 결과는 4.30점으로 판독 용이성이 가장 높았다. Foot internal oblique position에서는 T-F angle이 $90^{\circ}$인 경우 X선관 각도가 $0^{\circ}$일 때 설상골과 주상골의 겹침 정도는 4%이었고 블라인드 테스트 결과는 4.70점으로 가장 높았으며, T-F angle이 $135^{\circ}$경우에는 X선관 각도가 $0^{\circ}$일 때 그 겹침 정도는 5%이었고 블라인드 테스트 결과는 4.55점으로 가장 높게 나타났다. Foot external oblique position에서 T-F angle이 $90^{\circ}$인 경우 X선관 각도가 $15^{\circ}$일 때 설상골과 주상골의 겹침 정도는 4%이었고 블라인드 테스트 결과는 4.85점으로 가장 높았으며, T-F angle이 $135^{\circ}$경우에는 X선관 각도가 $15^{\circ}$일 때 그 겹침 정도는 5%이었고 블라인드 테스트 결과는 4.75점으로 가장 높게 나타났다. 결론적으로, 본 연구를 통하여 X 선 족부검사에서 각 position에 해당하는 주상골 관찰에 용이한 T-F 각도와 X선관 각도를 확인할 수 있었으며, 향후 본 연구 결과를 바탕으로 주상골 골절 판독에 유용한 참고자료가 될 수 있을 것으로 여겨진다.
Khatami, Alireza;Heshmati, Mahdi;Aghakouchak, Ali Akbar
Earthquakes and Structures
/
제19권3호
/
pp.197-214
/
2020
Diagrid structures have been introduced as a fairly modern lateral load-resisting system in the design of high-rise buildings. In this paper, a novel diagrid system called tube-in-tube diagrid building is introduced and assessed through pushover and incremental dynamic analyses. The main objectives of this paper are to find the optimum angle of interior and exterior diagrid tube and evaluate the efficiency of diagrid core on the probability of collapse comparing to the conventional diagrid system. Finally, the seismic performance factors of the proposed system are validated according to the FEMA P695 methodology. To achieve these, 36-story diagrid buildings with various external and internal diagonal angles are designed and then 3-D nonlinear models of these structures developed in PERFORM-3D. The results show that weight of steel material highly depends on diagonal angle of exterior tube. Adding diagrid core generally increases the over-strength factor and collapse margin ratio of tall diagrid buildings confirming high seismic safety margin for tube-in-tube diagrid buildings under severe excitations. Collapse probabilities of both structural systems under MCE records are less than 10%. Finally, response modification factor of 3.0 and over-strength factor of 2.0 and 2.5 are proposed for design of typical diagrid and tube-in-tube diagrid buildings, respectively.
본 논문은 콘크리트충전 각형강관 기둥-H형강보 접합부로서 기둥을 관통하는 철근과 T-스티프너를 외부에 보강한 새로운 접합부상세를 제안하고, 5개의 십자형 접합부 실험체를 역대칭 반복가력 실험하였다. 실험변수는 T-스티프너의 길이(200, 250mm), 철근의 직경(HDl6, 19)이다. 실험결과 T-스티프너 길이의 증가가 철근의 강도비 증가보다 내력 및 강성에 미치는 영향이 보다 크고, T-스티프너의 보강만으로도 보붕괴형의 안정적인 이력거동을 나타내었다. 또한, T-스티프너와 강관 코너부의 용접 시에는 취성파괴의 가능성에 주의하고, 본 논문에서 제안한 용접방법을 따르는 것이 적절할 것으로 판단된다.
기존 콘크리트충전 각형강관(CFT) 구조에 사용하는 각형강관은 4개의 판을 용접하여 제작하는 박스칼럼이 일반적이다. 그러나 이러한 강관은 제작효율이 저하되며, 또한 기둥-보 접합부에는 내측 다이아프램과 관통 다이아프램을 용접하는데 특수한 용접기술이 필요하다. 따라서, 얇은 강판을 절곡하는 방식으로 응력집중 위치의 용접을 피하고, 단면효율이 극대화된 내부앵커 돌출형의 용접조립 각형강관을 개발하게 되었다. 용접조립 각형강관은 강관내부에 스티프너가 설치되어 내측 다이아프램과 관통 다이아프램과 간섭이 발생하게 되므로 본 연구에서는 용접조립 각형CFT 기둥-보 접합부로 외다이아프램형식을 채택하고 외다이아프램의 설계식을 제안하였으며, 기둥-보 접합부의 거동을 파악하기 위해 실대형 4개 실험체를 제작하여 구조거동 및 내력을 분석하였다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.