• Title/Summary/Keyword: external standard method

Search Result 252, Processing Time 0.027 seconds

Performance Evaluation of Seismic Stopper using Structural Analysis and AC156 Test Method

  • Ryu, Hyun-su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.3
    • /
    • pp.277-285
    • /
    • 2020
  • Recently, studies have been actively conducted on seismic design and improvement of the seismic performance of bridges, buildings, factories, and plants. In particular, heavy items that are being manufactured or waiting to be shipped from factories (such as generators, engines, and boilers) must be equipped with seismic stoppers to prevent them from moving or falling during an earthquake. Seismic stoppers should be suitably determined by the size and weight of these heavy items; however, they have no general design standard. In this study, structural analyses and seismic tests were conducted to evaluate the performance of newly designed seismic stoppers. Structural analysis was performed on three stopper models to estimate the external load at which the yield stress of the material was not exceeded. Based on the analysis results, a seismic test of the stopper was carried out in accordance with the AC156 test method. Finally, product specifications for all three seismic stopper models were determined and their static/dynamic load performance was evaluated.

The Development of Vital Sign Web Viewer Systems using HL7 Protocol (HL7 프로토콜을 이용한 생체정보 웹 뷰어 시스템 개발)

  • Lim, Se-Jung;Kang, Ki-Woong;Seo, Jong-Joo;Kim, Gwang-Jun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.3 no.2
    • /
    • pp.112-117
    • /
    • 2008
  • HL7 is well-Known standard protocol for text data generated in hospital information systems. Vital sign information web viewer systems is also the standard protocol for medical image and transfer. In order to embrace new technologies as telemedicine service, it is important to develope the standard protocol between different systems in the hospital, as well as the communication with external hospital systems. In this paper, we proposed integration method between vital sign web viewr systems and hospital information systems. Through the proper data exchange and modification of information management, HIS will offer better work flow to all hospital employee.

  • PDF

The Development of Vital Sign Web Viewer Systems using HL7 Protocol (HL7 프로토콜을 이용한 생체정보 웹 뷰어 시스템 개발)

  • Lim, Se-Jung;Kang, Ki-Woong;Seo, Jong-Joo;Kim, Gwang-Jun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.2 no.2
    • /
    • pp.123-128
    • /
    • 2007
  • HL7 is well-Known standard protocol for text data generated in hospital information systems. Vital sign information web viewer systems is also the standard protocol for medical image and transfer. In order to embrace new technologies as telemedicine service, it is important to develope the standard protocol between different systems in the hospital, as well as the communication with external hospital systems. In this paper, we proposed integration method between vital sign web viewr systems and hospital information systems. Through the proper data exchange and modification of information management, HIS will offer better workflow to all hospital employee.

  • PDF

Pretreatment method of urinary thiodiglycolic acid as metabolite of vinyl chloride (염화비닐의 요중 대사물질인 thiodiglycolic acid의 분석을 위한 전처리 조건)

  • Hong, Joo Youn;Kim, Chi Nyon;Jung, Jae Hoon;Chang, Jung Hwan;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.9 no.1
    • /
    • pp.23-40
    • /
    • 1999
  • The analysis of thiodiglycolic acid in urine has been used as an index of biological exposure to vinyl chloride. Unfortunately thiodiglycolic acid has a strong hydrophilic character, because it has two carboxylic groups, so that it can only be extracted with organic solvent with a great difficulty. Underivatized thiodiglycolic acid tends to tail because of non-specific interaction with the inert support. Therefore, esterification is the obvious first choice for derivatization of thiodiglycolic acid, particularly for gas chromatography. In this study, the focus of interest is to compare two method of esterifications (methylation and silylation). Methylation is to make the methyl ester of thiodiglycolic acid by reaction with diazomethane. Silylation is to make the trimethylsilyl ester of thiodiglycolic acid by reaction with N-trimethylsily-ldiethylamine. The results and conclusions are as the following: 1. The detection limit (sensitivity) of methylated thiodiglycolic acid was $5.00{\mu}g/m{\ell}$ and silylated thiodiglycolic acid was $3.07{\mu}g/m{\ell}$ by gas chromatography with flame ionization detector. 2. The optimal liquid-liquid extraction of thiodiglycolic acid was as following: To each of the tubes, $15m{\ell}$ of urine, concentrated sulfuric acid (pH 1 - 2) and 5 gsodium sulfate were added. The samples was extracted three times with $5m{\ell}$ ethylacetate each time. 3. The methylated thiodiglycolic acid was more stable than silylated thiodiglycolic acid in extractional solvent which contained humidity. 4. The precision (pooled coefficient of variation for 4 days) of the analysis was 0.07324 in methylated thiodiglycolic acid with external standard calibration, and 0.07033 in methylated thiodiglycolic acid with internal standard calibration. 5. The precision (pooled coefficient of variation for 4 days) of the analysis was 0.10914 in silylated thiodiglycolic acid with external standard calibration, and 0.13602 in silylated thiodiglycolic acid with internal standard calibration. From the above results, the analysis of methylated thiodiglycolic acid was more sensitive (limit of detection) than silylated thiodiglycolic acid by gas chromatography. However, the methylated thiodiglycolic acid was stable in the humidity and was separated sharply on chromatogram. Also, analysis of methylated thiodiglycolic acid was more precise (pooled coefficient of variation for 4 days) than silylated thiodiglycolic acid. In conclusion, it is established that the analysis of methylated thiodiglycolic acid is appropriate for biological monitoring of exposure to vinyl chloride.

  • PDF

Evaluation Technique of Linearity of Ratio Error and Phase Angle Error of Voltage Transformer Comparison Measurement System Using Capacitor Burden (전기용량 부담을 이용한 전압변성기 비교 측정 시스템의 비오차 및 위상각 오차의 직선성 평가기술)

  • Jung Jae Kap;Kim Han Jun;Kwon Sung Won;Kim Myung Soo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.6
    • /
    • pp.274-278
    • /
    • 2005
  • Voltage transformer(VT) comparison measurement system is usually used for measurements of ratio error and phase angle error of VT made in industry. Both ratio error and phase angle error in VT are critically influenced by values of burden of VT used. External burden effects on both ratio error and phase angle error in VT are theoretically calculated. From the theoretical calculation, a method of evaluation for linearity of ratio error and phase angle error in VT measurement system have been developed using the standard capacitive burdens, with negligible dissipation factor less than 10$^{-4}$. These burden consists of five standard capacitors, with nominal capacitance of 1.1 $\mu$F, 1 $\mu$F, 0.1 $\mu$F, 0.01 $\mu$F, 0.001 $\mu$F. The developed method has been applied in VT measurement system of industry, showing in good consistency and linearity within 0.001 $\%$ between theoretical and measured values.

Determination of Trace Elements of Ge and P in a Gold Bonding Wire by Inductively Coupled Plasma Atomic Emission Spectrometry

  • Choi, Sung-Min;Lee, Gae-Ho;Han, Jae-Kil
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.2
    • /
    • pp.393-397
    • /
    • 2008
  • Inductively coupled plasma atomic emission spectrometry (ICP-AES) was used to determine the presence of germanium and phosphorus in a pure gold bonding wire. The samples were dissolved with hydrobromic acid and nitric acid at room temperature. The quantitation limits were 0.012 mg L-1 at 265.118 nm for Ge and 0.009 mg L-1 at 177.495 nm for P. Using the mixed acid digestion formula of DIW+HBr+HNO3, the recoveries were in the range of 98-100% and the relative standard deviation was within 1.1-2.3%. On the other hand, the amount of Ge decreased by about 16.2% using DIW+HCl+HNO3, due to the formation of a volatile compound. The Ge contents determined using the external method and the standard addition method were 9.45 mg kg-1 and 9.24 mg kg-1, respectively, and the P contents, using the same methods, were 22.49 mg kg-1 and 23.09 mg kg-1, respectively. Both methods were successfully used to determine the trace amounts of P and Ge in the pure gold bonding wire samples.

A Study on a Pattern Design for Pleated Skirts Based on the Amount of Waist Darts by Somatotype (체형별 허리 다트량을 활용한 플리츠 스커트 원형 설계에 관한 연구)

  • Lee, Jung-Hwa;Maruta, Naomi;Hirokawa, Taeko
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.35 no.8
    • /
    • pp.933-945
    • /
    • 2011
  • This research proposes a pattern design method for 24 pleated skirts in order to develop an automatic draft program for pleated skirts that will enhance fit and enable mass production. The research method and results are outlined as follow. 1. Three-dimensional body measurements were conducted on 30 randomly selected women in their 20s. By using 34 body measurement items and 6 types of calculations among the items, the items required in the designing of an original pleated skirt were extracted. They were then interpreted through correlation analysis, variance analysis, a t-test, linear regression analysis and multiple regression analysis. 2. An extra amount was added to the waist measurement and external capsule measurement according to the number of times the pleats coincided and the thickness of the fabric by the degree of polymerization of the horizontal cross section (the test of this research: 0.518mm). The extra amount of waist measurement was 3.6cm while the hip measurement was 4.3cm larger than the hip measurement combined with the external capsule measurement and the extra amount. 3. Based on the ${\pm}$standard deviation/2 as the average of the difference between the external capsule measurement and waist measurement, the subjects were classified into 3 somatotypes. Somatotype 1 presented an average total length of waist darts of 23.6cm while that of somatotype 2 was 26.2cm and that of somatotype 3 was 30.2cm. It has been confirmed that there is a significant difference among somatotypes in the total length of waist darts from the front center to the front side and the total length of waist darts from the side to the back center in terms of the average amount of waist darts for every 12 parts on the WL.

Evaluating the accuracy (trueness and precision) of interim crowns manufactured using digital light processing according to post-curing time: An in vitro study

  • Lee, Beom-Il;You, Seung-Gyu;You, Seung-Min;Kim, Dong-Yeon;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.2
    • /
    • pp.89-99
    • /
    • 2021
  • PURPOSE. This study aimed to compare the accuracy (trueness and precision) of interim crowns fabricated using DLP (digital light processing) according to post-curing time. MATERIALS AND METHODS. A virtual stone study die of the upper right first molar was created using a dental laboratory scanner. After designing interim crowns on the virtual study die and saving them as Standard Triangulated Language files, 30 interim crowns were fabricated using a DLP-type 3D printer. Additively manufactured interim crowns were post-cured using three different time conditions-10-minute post-curing interim crown (10-MPCI), 20-minute post-curing interim crown (20-MPCI), and 30-minute post-curing interim crown (30-MPCI) (n = 10 per group). The scan data of the external and intaglio surfaces were overlapped with reference crown data, and trueness was measured using the best-fit alignment method. In the external and intaglio surface groups (n = 45 per group), precision was measured using a combination formula exclusive to scan data (10C2). Significant differences in accuracy (trueness and precision) data were analyzed using the Kruskal-Wallis H test, and post hoc analysis was performed using the Mann-Whitney U test with Bonferroni correction (α=.05). RESULTS. In the 10-MPCI, 20-MPCI, and 30-MPCI groups, there was a statistically significant difference in the accuracy of the external and intaglio surfaces (P<.05). On the external and intaglio surfaces, the root mean square (RMS) values of trueness and precision were the lowest in the 10-MPCI group. CONCLUSION. Interim crowns with 10-minute post-curing showed high accuracy.

A Study on the Transient Measurement of the Effective Thermal Diffusivity of Insulation Materials by NPE Method (NPE법을 이용한 절연재료의 유효열확산계수의 과도측정에 관한 연구)

  • Lim, Dong Joo;Bae, Sin Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.2 no.3
    • /
    • pp.243-255
    • /
    • 1990
  • The objective of this study is to present an efficient measurement method of the effective thermal diffusivity for the fibrous insulation material. The non-linear parameter estimation (NPE) method is adapted for this analysis because of its accuracy and its results are compared with those by other direct methods such as CTP, CHP and STD method. A experimental system is constructed with bell-jar vaccum chamber, diffusion pump, tube type furnace, control unit and data acquisition system included with A/D converter and IBM XT/AT personal computer. The typical results obtained from this study are as follows; 1) NPE method can be recommended as an useful and accurate method to measure the effective thermal diffusivity of insuation material because it is shown that the measurement error compared with those by other direct methods is reduced for standard material, NBS-1450b. 2) NPE method can minimize the effects of ill-measured temperature due to external disturbance, because the final value is found by point to point estimating. 3) NPE method dose not depend on the kinds of heat flux, since the surfac temperature are used to estimate the thermal diffusivity. 4) With NPE method, compared with the steady state method, a measuring time and a sample size could be reduced.

  • PDF

The Approach of Properties-Flavours Theory and the Study of Morphological Standard in CORNI FRUCTUS (산수유(山茱萸)의 기미론(氣味論)적 해석과 내외부형태연구)

  • Choi, Mun-Il;Lee, Hwa-Jung;Yun, Ju-Bong;Kim, Ja-Young;Kang, Kyoung-Sik;Shin, Chol-Gyun;Ju, Young-Sung
    • The Korea Journal of Herbology
    • /
    • v.21 no.2
    • /
    • pp.109-119
    • /
    • 2006
  • Objectives : This study was performed to approach of properties-flavours theory and the study of morphological standard in CORNI FRUCTUS. Methods : The properties-flavours theory were attempted with bibliographic method and various climate-information. The external-internal morphological standards were determined by using stereoscope and butanol series. Results and conclusion : 1. The significant analysis for the corni fructus as the properties-flavours theory, is a follow-up survey of the effect written in the official oriental medicine book. 2. The other analytic methods according to the gathering time, processing or storing system or especially nature or growth environment(altitude, temperature,. the mean moisture, and the agronomical survey) by way of the explanation of properties-flavours theory appears so many insufficiency at the many cases. 3. The external and internal characteristics according to the shape of original plant or herbal states, entirely correspond to all the literature on this subject. 4. According to the place of production, there are some different points. (l) In the external shapes, it is reasonable that if we make the basic standard of classification by the sharpness of color, the existence of gloss and the size of products. In the case of the Korean products, it shows bright and glossy color totally, but in the case of North Korea products, it shows black and lackluster. And in the case of the foreign products, it has softer body than Korea one and shows white color on the surface. (2) In the internal shapes, the Korea products has a thicker cuticle layer than the foreign one, and has fewer ca-oxalate in the parenchyma cell.

  • PDF