• Title/Summary/Keyword: external interference

Search Result 148, Processing Time 0.032 seconds

Application of wavelet filtering for Suppression of noise from PD signals (부분방전신호로부터 노이즈의 제거를 위한 웨이블렛필터링 기법의 적용)

  • Lee, K.W.;Park, C.H.;Kang, S.H.;Lim, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1845-1848
    • /
    • 2003
  • PD(Partial Discharge) signal have the range from several kHz to several GHz. External noises don't give any interference to discerning PD signals with high frequency bandwidth between several hundreds MHz to several GHz but, in the range between several decades kHz to several MHz, are big obstacles to prevent from discriminating PD signals. Therefore, selecting appropriate filter to decrease the influence of noise is important problem. PD signals have the characteristics both short duration and non-continuous pulse train. For separating PD signals from External noises, some different filtering methods different from conventional ones are needed and wavelet filtering method was convinced to be suitable filtering method in various investigations. This paper has simulated PD signal and various noises and investigated the influences for the performance of wavelet filter by varying the components relative to designing of wavelet filter and constructed suitable one. For the purpose of convincing the performance of wavelet filter, real PDs were produced in needle to plane electrode structure. This small PD signal was mixed with external noises and filtered with wavelet filter. We have obtained apparent PD signals and noises are well suppressed by wavelet filter.

  • PDF

Properties of the Load-Sensing Hydraulic System from a Viewpoint of Control (제어관점에서의 부하감지형 유압시스템의 특성)

  • 김성동
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.3
    • /
    • pp.738-750
    • /
    • 1994
  • The load-sensing hydraulic system which was developed to improve energy efficiency of conventional hydraulic systems has its own properties. The instability of system responses, linearity of a servo valve, robustness for variation of external load, and dynamic interference between hydraulic motors are such properties which have much to do with control properties of the system. The load-sensing hydraulic system has instability tendancy because the load-sensing mechanism makes a positive feedback loop between the motor part and the pump part. A flow property of the servo valve can be said to be linear because the flow through the valve has nothing to do with a load pressure and the flow is strictly proportional to a valve opening which is adjusted by a valve command signal. The resultant control property can be said to be robust because the steady-state control performance is independent to the load actuated on the motor shaft. In the case when one pump simultaneously drives more than two hydraulic motors, the pump outlet pressure is determined by a hydraulic motor of the largest load pressure among all of the hydraulic motors, and, thus, the other motors are dominated by the largest load pressure. That is, the other motors can be said to be interfered by the motor of the largest load pressure.

The analysis of error characteristics in self-imaging and improved optimization of waveguide structure for multi-mode interference devices (자아결상원리의 오차 해석을 통한 다중모드간섭기의 최적화)

  • 홍정무;오범환;이승걸;이일항;우덕하;김선호
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.1
    • /
    • pp.38-43
    • /
    • 2002
  • Simple principles of self-imaging in Multi-Mode Interference (MMI) devices are based on the approximation of propagation constants. The analysis of the basic nature of the self-imaging principle reveals the problems of previous optimization methods, and provides a new scheme to optimize the external variables for the reconciliation of approximation problems by considering two different tendencies of approximation effects. Furthermore, the representative mode method is proposed to make the application easy. This optimization method provides an essential method for stable design and fabrication of MMI devices with improved characteristics.

New concept of Wireless LAN service for Wireless home network (무선 홈 네트워크 구축을 위한 신개념 무선랜 서비스)

  • Kim, Wan-Ki;Ki, Ho-Young;Lee, Hang-Su;Woo, Jong-Myoung;Hong, Sung-Yong
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.385-390
    • /
    • 2005
  • In this paper, we studied a new concept of wireless LAN service. Current service for wireless LAN has some weak points such as occuring a frequency shadowed area, high cost for setting a number of APs, electromagnetic interference by means of a large output transmission and weak security issues. To reduce those problems, we proposed setting antennas which are from one AP for each rooms, and designed a suitable antenna. After that we measured a PMA(Propagation Measurement & Analysis). Experimental results showed that a new concept of wireless LAN service is excellent to resolve interference and weak security issues by minimizing external propagation of a building.

  • PDF

A multivariable controller design of 6 DOF motion simulator (6자유도 운동재현기의 다변수 제어기 설계)

  • 이호영;강지윤;이교일
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.449-454
    • /
    • 1994
  • The Stewart Platform is one example of a motion simulator which generater 6DOF motion in space by six actuators in parallel. The presented control methrol of 6DOF motion simulator is generally classified into two types, one is SISO and the other is MIMO control type. The SISO control can't compensate for external load variation and different dynamic behavior of 6DOF motion, trerefore this type don's control motion precisely. On the other hand, the MIMO control compensates for a interference of 6DOF motion because MIMO controller is designed with 6DOF motion simulator synamics. But MIMO control of motion simulator has a complexity of 6DOF displacement feedback, because in oder to obtain feedback value we must solve the forward kinematics using measurement of cylinder length or design a state estimator, unless measurement of 6DOF displacement is possible. In this paper, a multivariable controller using H .inf. optimal control theory is designed to consider a interference of 6DOF motion and to obtain robust,precise control of system. Also in order to solve the mentioned problem of MIMO control, this paper presents a modified MIMO control model which control 6DOF motion by using feedback of measurement od cylinder length.

  • PDF

A Study for Absolutely Distance Measurement System of Wavelength Variable Type by Using Pinciple of the Michelson Interometer (마이켈슨 간섭계의 원리를 이용한 파장변화형 절대 거리측정기의 기초 연구)

  • 김철한;신영록;양윤석;김한근;사공건
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.651-653
    • /
    • 2000
  • In this study, a distance-measurement system was proposed by using principle of the Michelson Interferometer and a fundamental research was carried out. In case of the rnichelson interferometer, relativity distance was measured by relativity-difference of two course of light. But wavelength of light source were changed in this system in order to use interference phenomenon of michelson interferometer in measuring absolutely distance. Wavelength of input signal were changed periodically and were interfered electrically. So absolute distance can be calculated by using $\Delta\lambda$ and measuring $\eta\Delta$ in electric interference. Nose by a external factor was small in this system because a absolutely distance was measured by phase difference. And a dispersion of noise was small in pulse-echo response because a error was occurred in range of phase difference of signal. Also very wide range can be measured by only single system because informations of distance were acquisited in wavelength level.

  • PDF

Structural Behavior of Welded Built-up Square CFT Column to Beam Connections with External Diaphragm (용접조립 각형 CFT 기둥-보 외다이아프램 접합부의 구조 거동)

  • Lee, Seong Hui;Kim, Young Ho;Choi, Sung Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.2
    • /
    • pp.75-83
    • /
    • 2016
  • Existing tubes for concrete filled tubular structure are made through welding of four plates irrespective, but the production performance is poor and special welding technique is needed to weld the internal or through diaphragm. Accordingly, We developed a welded built-up square steel tube having a welding lines and a stiffeners at location out of stress concentration. The welded built-up square steel tube occurred a interference with stiffeners at the internal or through diaphragm, therefore researches of a external diaphragm for welded built-up square CFT column connections are needed for the purpose of avoidance of a interfere with stiffeners. In this study we suggest a design formulation for external diaphragm of the welded built-up square CFT external diaphragm connections. Four specimens were manufactured for a experimental test, then we analyzed the behaviors of the specimens.

Enhancing the Reliability of Coating Flaw Detection for Pipes Buried in Soil Using a Multi-Electrode Detector (다전극 탐상을 통한 토중 매설배관 피복결함 탐상 정확도의 개선)

  • Kim, M.G.;Lim, B.T.;Kim, K.T.;Chang, H.Y.;Park, H.B.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.265-280
    • /
    • 2020
  • External corrosion of buried pipes can be controlled using both coating and cathodic protection. However, deterioration of the coating can occur due to several reasons. The detection reliabilty of coating flaw detection methods is affected by interference such as metal objects connected to rectifiers and copper grids. When performing parallel direct current voltage gradient (DCVG) inspection, a sine wave form without potential reversal in voltage gradient appears in the area where the interference exists. However, this area may be not identified using existing methods. The objective of this study was to determine the effect of analyzing direction on the reliability of coating flaw detection of pipes buried in soil using a multi-electrode detector. DCVG on the buried pipe was measured along the buried pipe. This measurement parallel to the pipe was repeated. Measured data were analyzed for parallel, vertical, and diagonal directions. The reliability of coating flaw detection was improved by up to 46.4% compared to the conventional method.

Testing of Common Electromagnetic Environments for Risk of Interference with Cardiac Pacemaker Function

  • Tiikkaja, Maria;Aro, Aapo L.;Alanko, Tommi;Lindholm, Harri;Sistonen, Heli;Hartikainen, Juha E.K.;Toivonen, Lauri;Juutilainen, Jukka;Hietanen, Maila
    • Safety and Health at Work
    • /
    • v.4 no.3
    • /
    • pp.156-159
    • /
    • 2013
  • Background: Cardiac pacemakers are known to be susceptible to strong electromagnetic fields (EMFs). This in vivo study investigated occurrence of electromagnetic interference with pacemakers caused by common environmental sources of EMFs. Methods: Eleven volunteers with a pacemaker were exposed to EMFs produced by two mobile phone base stations, an electrically powered commuter train, and an overhead high voltage transmission lines. All the pacemakers were programmed in normal clinically selected settings with bipolar sensing and pacing configurations. Results: None of the pacemakers experienced interference in any of these exposure situations. However, often it is not clear whether or not strong EMFs exist in various work environments, and hence an individual risk assessment is needed. Conclusions: Modern pacemakers are well shielded against external EMFs, and workers with a pacemaker can most often return to their previous work after having a pacemaker implanted. However, an appropriate risk assessment is still necessary after the implantation of a pacemaker, a change of its generator, or major modification of its programming settings.

A Study on the Transmission Length Limitation by Chromatic Dispersion in High Speed FOT스s (초고속 광파이버 전송시스템에서 색분산에 의한 전송거리 제한에 관한 연구)

  • 정은숙;김재평;정진호;김영권
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.4 no.3
    • /
    • pp.18-29
    • /
    • 1993
  • In single mode fiber optic transmission systems(FOT's) operated at high modulation rates over long fiber spans, chromatic dispersion can produce distortion in the demodulated waveforms, resulting in intersymbol interference(ISI) in the received signal and a reduction of transmission system performance. In this paper, chromatic dispersion limitations for intensity modulation and direct detection(IM-DD) systems are studied by considering the effect of phase modulation to amplitude modulation (PM-AM) conversion noise. Laser phase noise conversion to amplitude noise due to fiber chromatic dispersion is analyzed by deriving the noise power spectral density. We first derive the noise power spectral density of the laser phase noise to intensity noise conver- sion. Next, also evaluate the system power penalty and the transmitter laser linewidth required to avoid PM-AM conversion noise penalties in long-haul nonregenerative transmission system using an external modulator and optical amplifiers. For such system with optical amplifiers, transmission sys- tem length is limited due to fiber chromatic dispersion, even if an ideal external modulator is used.

  • PDF