• Title/Summary/Keyword: external electricity

Search Result 133, Processing Time 0.026 seconds

A Study on the Identification of Electrical Materials by Fire (화재로 인한 전기재료 감식에 관한 연구)

  • 김용주;박남신;조경순;홍진웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1991.10a
    • /
    • pp.24-26
    • /
    • 1991
  • Identification of the cause of electrically related fire accident may be approached either by studying accident related electric properties or by investigating power instruments at the site of the accident. In the present paper, the former approach is taken especially on investigating the consequences of excessive current induced by electric short circuiting of high power instruments which is reported as the primary cause electricity related fire accidents. In order to provide reliability of the identification method, microscopic photograph's are taken for the cross sections of the electric wires after being exposed to over current and heated by external means, respectively The results are consequently compared and analysed.

A study on The Fuzzy Based PID Position controller for Step Motor Drives

  • Kim, Seung-Cheol;Cho, Yong-Sung;Park, Jae-Hyung;Kang, Shin-Chul;Bay, Gyu-Han
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1496-1499
    • /
    • 2005
  • In this paper, we applied step motor drive using a fuzzy logic control based on PID controller. A designed this controller's purpose is improved robust and autonomous characteristic in which the variation of external load affects plant parameter. Therefore, in this paper, using a fuzzy logic control based on PID controller of two fuzzy-PI and fuzzy-D is obtained decremental overshoot and a special response quality.

  • PDF

Damage Detection of Decrepit Tunnel Structures using the NDT (비파괴 검사법에 의한 노후터널의 건전도 평가)

  • Kim, Dong-Gyou;Jung, Ho-Seop
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.1388-1391
    • /
    • 2010
  • Recently, the construction of road, subway, railroad, and microtunnel for electricity supplement have been increased because of increasement of traffic in urban area, increasement of industrial transportation, and the network between cities in Korea. The deterioration of tunnel structure may occur by various internal and external factors and particularly, tunnel structures tend to contact with either underground water or harmful ions. Therefore, leakage sometimes occurred through the cracks and joints of concrete lining. The leakage in tunnel may affect the durability of concrete lining. In this study, to evaluate the durability and deterioration of concrete lining in tunnel structures, we were performed the various experiments for compressive strength. Compressive strength obtained from nondestructive inspection and compressive strength test varies according to the concrete lining conditions.

  • PDF

Speed Control System of Induction Motor with Fuzzy-Sliding Mode Controller for Traction Applications

  • Kim, Duk-Heon;Ryoo, Hong-Je;Rim, Geun-Hie;Kim, Yong-Ju;Won, Chung-Yuen
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.3B no.1
    • /
    • pp.52-58
    • /
    • 2003
  • The application of a sliding mode control for improving the dynamic response of an induction motor based speed control system is presented in this paper and provides attractive features, such as fast response, good transient performance, and insensitivity to variations in plant parameters and external disturbance. However, chattering is a difficult problem for which the sliding mode control is a popular solution. This paper presents a new fuzzy-sliding mode controller for a sensorless vector-controlled induction motor servo system to practically eliminate the chattering problem for traction applications. A DSP based implementation of the speed control system is employed. Experimental results are presented using a propulsion system simulator. The performance of the drive is shown to be practically free from chattering.

Development of the partial discharge detecting equipment using electromagnetic wave in deteriorated insulator (배전용 불량애자에서의 전자파 부분방전 검출장치 개발)

  • Kang, C.W.;Song, I.K.;Kim, J.Y.;Lee, B.S.;Kang, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1667-1669
    • /
    • 2001
  • The clack of Insulator, which results from internal or external surges such as electrical, mechanical, and thermal stress, might cause ground fault and a power failure without proper repairs. In order to minimize losses caused by a short-term or long-term power failure, it is necessary to detect the deteriorated insulator as early as possible. To do so, we will develop a new device, which can detect and trace an deteriorated insulator by monitoring its physical change the variation of frequency spectrum. This device will do so by finding a Periodic wave sharp (120 Hz), a peculiar wave generated by defused electricity.

  • PDF

Efficiency Evaluation of Wind Power Blade Surface Cleaning using Brush and Water Jet (브러시 및 워터젯을 이용한 풍력 발전 블레이드 표면 청소 효율 측정)

  • Jeon, Minseok;Kim, Byunggon;Park, Sora;Hong, Daehie
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.9
    • /
    • pp.977-982
    • /
    • 2013
  • Blades of wind energy plants are exposed to external shocks or internal cracks during operation. Furthermore, the blade surfaces can be contaminated by substances such as dust, blood of birds, salt or insects which can decrease the electricity generation efficiency significantly. For this reason, many blade cleaning companies started to appear and a variety of methods for cleaning were suggested. Despite these diverse methods, there has been no study to investigate how effectively to clean the substances in quantitative manner. In this paper, the cleaning efficiency of two rotor blade cleaning methods, brush and water-jet, is examined through experiments by changing operating parameters. Then, the optimal operating conditions for both methods are derived.

Alignment and Packaging Technology for Improving The Efficiency of The Solar Daylighting System (태양광 조명 시스템의 집광 효율 향상을 위한 정렬 및 패키징 기술)

  • Kim, Taehoon;Sheen, Byung-Han;Jeong, Myung Yung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.21 no.3
    • /
    • pp.37-41
    • /
    • 2014
  • In this work, we investigated the efficiency improvement of concave mirror based solar daylighting system that does not convert light to electricity. Total efficiency of the system is substantially affected by external environment and focusing position, alignment of reflectors, lenses. As a result of simulation, we obtained the max. efficiency in which depends on convex lens position.

Discharge and Ozone Characteristics of Multi Discharge Type Ozonizer (다중방전형 오존발생기의 방전 및 오존생성특성)

  • Chun, Byung-Joon;Mun, Kyung-Su;Song, Hyun-Gik;Kim, Keum-Yeung;Lee, Kwang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1090-1092
    • /
    • 1999
  • In this paper, multi discharge type ozonizer has been designed and manufactured. The of ozonizer is equipped with three electrodes(central electrode of screw shape, internal electrode and external electrode). This paper describes the following two characteristics: (1) The characteristics of discharge with variation of output voltage of AC H.V source, flow rate of oxygen supplied gas and discharge voltage. (2) The characteristics of ozone generation by varying flow rate and discharge power.

  • PDF

Time Domain Simulation Analysis For Wind Farm with DFAG (이중 여자 비동기 발전기를 포함한 풍력단지 시모의 해석)

  • Cho, Sung-Koo;Song, Hwa-Chang;Lee, Jang-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.439-442
    • /
    • 2009
  • As a result of increasing environmental concern, the penetration of renewable power on power systems is now increasing. Wind energy can be considered as the most economical energy sources to generate electricity without depletion of fossil fuel. The penetration of wind energy from wind farm is getting larger and larger, so we need adequate control strategies for wind farm. To devise adequate control strategies for wind farm, time domain simulation analysis needs to be performed. This presents a Simultaneous Implicit-based time domain simulation algorithm for wind farm with DFAG (Doubly Fed Asynchronous generator) connected to the external power systems. This paper shows an illustrative example with a 5-bus test system.

  • PDF

A Study on the Signal Processing and Robust Control for a 3-DOF Active Vibration Isolator (3자유도 능동형 제진 시스템을 위한 신호처리 및 강인제어에 관한 연구)

  • Moon, Jun-Hee;Kim, Hwa-Soo;Pahk, Heui-Jae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.153-156
    • /
    • 2006
  • The vibration isolation system is a system that attenuates the vibration transmitted from surroundings by using external energy supply like electricity and feedback and/or feedforward functions. Such a system needs stiff structure to make precise positioning without ripple within a certain bandwidth. So, a horizontal and rotary arrangement of the actuation module is suggested by using lever linkage. Modeling and kinematic formulation are completed and system identification is accomplished to tune the design variables accurately. The vibration isolation control is performed by mu-synthesis with the uncertainties in design variables. Low frequency signal enhancement circuit and saturation proof integration algorithm are devised to use seismic sensors for displacement control. This overall system shows good disturbance rejection performance.

  • PDF