• 제목/요약/키워드: external electricity

검색결과 137건 처리시간 0.025초

광전자소자를 위한 Piezo-Phototronic 효과의 연구 동향 (Recent Advances in the Piezo-Phototronic Effect for Optoelectronics)

  • 신경식;김성수;김도환;윤규철;김상우
    • 한국세라믹학회지
    • /
    • 제50권3호
    • /
    • pp.173-179
    • /
    • 2013
  • Wurtzite nanomaterials, such as ZnO, GaN, and InN, have become a subject of great scientific and technological interest as they simultaneously have piezoelectric and semiconductor properties. In particular, the piezoelectric potential (piezopotential) created by dynamic straining in the nanowires drives a transient flow of current in the external load, converting mechanical energy into electricity. Further, the piezopotential can be used to control the carrier generation, transport, separation, and/or recombination at the metal-semiconductor junction or p-n junction, which is called the piezophototronic effect. This paper reviews the recent advances on the piezophototronic effect to better use the piezophototronic effect to control the carrier generation, transport, separation and/or recombination for improving the performance of optoelectronic devices, such as photon detectors, solar cells and LEDs. This paper also discusses several research and design studies that have improved the output performance of optoelectronic devices.

데이터마이닝 기법을 이용한 주상변압기 고장유형 분석 및 복구 예측모델 구축에 관한 연구 (Fault Pattern Analysis and Restoration Prediction Model Construction of Pole Transformer Using Data Mining Technique)

  • 황우현;김자희;장완성;홍정식;한득수
    • 전기학회논문지
    • /
    • 제57권9호
    • /
    • pp.1507-1515
    • /
    • 2008
  • It is essential for electric power companies to have a quick restoration system of the faulted pole transformers which occupy most of transformers to supply stable electricity. However, it takes too much time to restore it when a transformer is out of order suddenly because we now count on operator in investigating causes of failure and making decision of recovery methods. This paper presents the concept of 'Fault pattern analysis and Restoration prediction model using Data mining techniques’, which is based on accumulated fault record of pole transformers in the past. For this, it also suggests external and internal causes of fault which influence the fault pattern of pole transformers. It is expected that we can reduce not only defects in manufacturing procedure by upgrading quality but also the time of predicting fault patterns and recovering when faults occur by using the result.

Power Cable Ampacity and Influential Factors Analysis under Operation

  • Tong, Qiang;Qi, Jianping;Wang, Yanling;Liang, Likai;Meng, Xiangxing;Zhang, Qiang
    • Journal of Information Processing Systems
    • /
    • 제14권5호
    • /
    • pp.1136-1149
    • /
    • 2018
  • With the increasing of urban electricity demand, making the most use of the power cable carrying capacity has become an important task in power grid system. Contrary to the rated ampacity obtained under extremely conservative conditions, this paper presents the various steady value of cable ampacity by using the changing surrounding parameters under operation, which is based on cable ampacity calculation equation under the IEC-60287 standard. To some degree, the cable ampacity analysis of actual surroundings improves the transmission capacity of cables. This paper reveals the factors that influence cable ampacity such as insulating layer thickness, allowable long-term conductor temperature, the ambient temperature, soil thermal resistance coefficient, and so on, then gives the class of the influence of these parameters on the ampacity, which plays a great role in accurately calculating the real-time ampacity and improving the utilization rate of cable in the complex external environment condition. Furthermore, the transient thermal rating of the cable is analyzed in this paper, and temperature variation of the conductor under different overload conditions is discussed, which provides effective information for the operation and control of the system.

원료가스의 온도변화를 고려한 중첩방전형 오존발생장치의 특성 (The Charecteristics of Superposed Discharge Type Ozonizing System Considering the Change of Temperature of. the Supplied Gas)

  • 이상근;송현직;전병준;김영훈;김상구;박원주;이광식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1705-1707
    • /
    • 1998
  • In this paper, a superposed discharge type ozonizer was designed and manufactured. The ozonizer is equipped with three electrodes : central electrode, internal electrode and external electrode, and it consists of two gaps. The ozone is generated by superposing silent discharge, which are respectively generated betweens two gaps. This paper describes the following two characteristics : (1) 'the characteristics of discharge with variation with output voltage of AC High Voltage source, quantity of the supplied gas and discharge voltage (2) the characteristics of ozone discharge power, temperature of the supplied gas.

  • PDF

중첩방전형 오존발생기에 관한 연구(I) (A Study on a Superposed Discharge Type Ozonizer(I))

  • 송현직;우성훈;이상근;박원주;이광식;이동인;이동헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1724-1726
    • /
    • 1997
  • In this paper, a superposed discharge type ozonizer(CISDO) has been designed and manufactured. CISDO is equipped with three electrodes(central electrode, internal electrode and external electrode), and it is composed of two gaps. Ozone is generated by overlapping silent discharge, which is respectively came from two gaps. This paper describes the following two characteristics : (1) The characteristics of discharge with variation of output voltage of AC H.V source, quality of supplied gas and discharge voltage (2) The characteristics of ozone generation with variation of quality of supplied gas. discharge power, operating number.

  • PDF

Development of Bipolar Plate Stack Type Microbial Fuel Cells

  • Shin, Seung-Hun;Choi, Young-jin;Na, Sun-Hee;Jung, Seun-ho;Kim, Sung-hyun
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권2호
    • /
    • pp.281-285
    • /
    • 2006
  • Microbial fuel cells (MFC) stacked with bipolar plates have been constructed and their performance was tested. In this design, single fuel cell unit was connected in series by bipolar plates where an anode and a cathode were made in one graphite block. Two types of bipolar plate stacked MFCs were constructed. Both utilized the same glucose oxidation reaction catalyzed by Gram negative bacteria, Proteus vulgaris as a biocatalyst in an anodic compartment, but two different cathodic reactions were employed: One with ferricyanide reduction and the other with oxygen reduction reactions. In both cases, the total voltage was the mathematical sum of individual fuel cells and no degradation in performance was found. Electricity from these MFCs was stored in a supercapacitor to drive external loads such as a motor and electric bulb.

Intelligent bolt-jointed system integrating piezoelectric sensors with shape memory alloys

  • Park, Jong Keun;Park, Seunghee
    • Smart Structures and Systems
    • /
    • 제17권1호
    • /
    • pp.135-147
    • /
    • 2016
  • This paper describes a smart structural system, which uses smart materials for real-time monitoring and active control of bolted-joints in steel structures. The goal of this research is to reduce the possibility of failure and the cost of maintenance of steel structures such as bridges, electricity pylons, steel lattice towers and so on. The concept of the smart structural system combines impedance based health monitoring techniques with a shape memory alloy (SMA) washer to restore the tension of the loosened bolt. The impedance-based structural health monitoring (SHM) techniques were used to detect loosened bolts in bolted-joints. By comparing electrical impedance signatures measured from a potentially damage structure with baseline data obtained from the pristine structure, the bolt loosening damage could be detected. An outlier analysis, using generalized extreme value (GEV) distribution, providing optimal decision boundaries, has been carried out for more systematic damage detection. Once the loosening damage was detected in the bolted joint, the external heater, which was bonded to the SMA washer, actuated the washer. Then, the heated SMA washer expanded axially and adjusted the bolt tension to restore the lost torque. Additionally, temperature variation due to the heater was compensated by applying the effective frequency shift (EFS) algorithm to improve the performance of the diagnostic results. An experimental study was conducted by integrating the piezoelectric material based structural health monitoring and the SMA-based active control function on a bolted joint, after which the performance of the smart 'self-monitoring and self-healing bolted joint system' was demonstrated.

Optimal ESS Investment Strategies for Energy Arbitrage by Market Structures and Participants

  • Lee, Ho Chul;Kim, Hyeongig;Yoon, Yong Tae
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.51-59
    • /
    • 2018
  • Despite the advantages of energy arbitrage using energy storage systems (ESSs), the high cost of ESSs has not attracted storage owners for the arbitrage. However, as the costs of ESS have decreased and the price volatility of the electricity market has increased, many studies have been conducted on energy arbitrage using ESSs. In this study, the existing two-period model is modified in consideration of the ESS cost and risk-free contracts. Optimal investment strategies that maximize the sum of external effects caused by price changes and arbitrage profits are formulated by market participants. The optimal amounts of ESS investment for three types of investors in three different market structures are determined with game theory, and strategies in the form of the mixed-complementarity problem are solved by using the PATH solver of GAMS. Results show that when all market participants can participate in investment simultaneously, only customers invest in ESSs, which means that customers can obtain market power by operating their ESSs. Attracting other types of ESS investors, such as merchant storage owners and producers, to mitigate market power can be achieved by increasing risk-free contracts.

연속 시적분 (CTI) 기반 풍력발전단지 시모의 해석 (Continuation Time Integration (CTI)-Based Time Domain Simulation Analysis for Wind Farms)

  • 조성구;송화창;이장호
    • 전기학회논문지
    • /
    • 제59권11호
    • /
    • pp.1971-1979
    • /
    • 2010
  • As a result of increasing environmental concern, the penetration of renewable power on power systems is now increasing. Wind energy can be considered as the most economical energy sources to generate electricity without depletion of fossil fuel. To devise adequate control strategies for wind farm, time domain simulation analysis needs to be performed. This presents a continuation time integration (CTI)-based time domain simulation algorithm for wind farm with doubly fed asynchronous generator (DFAG) connected to the external power systems. This paper depicts how to time trajectories are traced using CTI-based time domain simulation. Also this paper describes the possibilities of hierachical control for wind farm output limitation, and the coordinated control has been designed by hierarchical control structured from central control level to wind farm control board and to an individual wind turbine level. Finally it shows an illustrative example of time domain simulation result with two test systems through case study.

전기장 자극을 활용한 성게제거장치의 해상성능 평가 (On-site Investigation and Verification of Effect of the Sea Urchin Removal Devices)

  • 김대진;이정관;김성훈;오우석;오태건;이동길;이경훈
    • 한국수산과학회지
    • /
    • 제53권6호
    • /
    • pp.954-959
    • /
    • 2020
  • This study aimed to verify the effectiveness of rescue apparatus, that can capture crabs using external stimuli such as food and electricity, without relying on divers. In this study, a microcomputer-based controller and an IC-device-based controller were developed, and spot inspection was conducted using 20 modules and 30 sea urchin removal modules. Accordingly, 58, 18, 17, and 74 sea urchins were introduced in the first, second, third and fourth experiments, respectively. The result of evaluating the lure of each removal mechanism, based on the catch per unit effort, with an electrical stimulus was 1.1 (32/10), with a feeding stimulus was 3.4 (100/29), and with electrical and feeding stimuli was 3.5 (35/10).