• Title/Summary/Keyword: external chamber

Search Result 154, Processing Time 0.025 seconds

Chamber-to-chamber Variations in the Same Type of a Cylindrical Chamber for the Measurements of Absorbed Doses (흡수선량 측정 시 동종 원통형 이온함에서 이온함 간 변화)

  • Kim, Seong-Hoon;Huh, Hyun-Do;Choi, Sang-Hyun;Kim, Hyeog-Ju;Lim, Chun-Il;Shin, Dong-Oh;Choi, Jin-Ho
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.120-125
    • /
    • 2010
  • For the measurements of an absorbed dose using the standard dosimetry based on an absorbed dose to water the variety of factors, whether big, small, or tiny, may influence the accuracy of dosimetry. The beam quality correction factor ${\kappa}_{Q,Q_0}$ of an ionization chamber might also be one of them. The cylindrical type of ionization chamber, the PTW30013 chamber, was chosen for this work and 9 chambers of the same type were collected from several institutes where the chamber types are used for the reference dosimetry. They were calibrated from the domestic Secondary Standard Dosimetry Laboratory with the same electrometer and cable. These calibrated chambers were used to measure absorbed doses to water in the reference condition for the photon beam of 6 MV and 10 MV and the electron beam of 12 MeV from Siemens ONCOR. The biggest difference among chambers amounts to 2.4% for the 6 MV photon beam, 0.8% for the 10 MV photon beam, and 2.4% for the 12 MeV electron beam. The big deviation in the photon of 6 MV demonstrates that if there had been no problems with the process of measurements application of the same ${\kappa}_{Q,Q_0}$ to the chambers used in this study might have influenced the deviation in the photon 6 MV and that how important an external audit is.

A QUANTITATIVE STUDY ON THE DEGRADING EFFECT OF THE VARIOUS IRRIGATING AGENTS IN THE ELIMINATION OF RESIDUAL HYDROGEN PEROXIDE FOLLOWING WALKING BLEACHING (무수치 표백술 후 잔존 과산화수소수 제거를 위한 수종의 치수강 세척제의 효과에 관한 정량적 연구)

  • Kum, Kee-Yeon;Han, Won-Sup;Jung, Il-Young;Lee, Seung-Jong;Lee, Chan-Young;Oh, Byung-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.2
    • /
    • pp.656-669
    • /
    • 1998
  • Hydrogen peroxide at high concentration during walking bleaching may cause damage to the tooth structure and to the surrounding periodontal tissues and may develop external root resorption. Clinically, It is so important to find a method of prevention or minimization of these complications. The efficacy of various chamber-irrigating agents to eliminate residual hydrogen peroxide after walking bleaching was examined and compared with water rinse in this study. Extracted human 46 premolars without any cementoenamel junction defects were treated endodontically and based with IRM to 1 mm below CEJ and totally bleached 3 times for each tooth with 30% hydrogen peroxide and sodium perborate. Upon completion of the 3rd walking bleaching procedure, the cervical portion and pulp chamber of each group of teeth were irrigated with catalase, 70% ethylalcohol, acetone, and distilled water. And then, a radicular hydrogen peroxide penetration was measured with spectrophotometer immediately after each bleaching and following treatment with each chamber-irrigating agents, and the significance of their eliminating efficacy of residual hydrogen peroxide was analyzed by Kruskal-Wallis test. The results were obtained as follows. 1. Cervical root penetration of hydrogen peroxide was increased as the bleaching procedure was repeated(P<.01). 2. The most effective irrigant that removed residual hydrogen peroxide was the catalase, and the least effective one was water rinsing (P<.01).; there was no significant difference between the acetone and ethanol group. 3. The Irrigation with antioxidant enzyme or water-displacement solutions can eliminate residual oxygen radicals from the pulp chamber effectively after walking bleaching. So, these agents can reduce adverse effects such as cervical external resorption and periapical inflammation and prevent residual $O_2$ from impeding composite resin polymerization, thus increase the bonding strength of composite resin. This, in turn reduces microleakage and discoloration of the esthetic restoration, extending its service-life.

  • PDF

Intergrated Design Software Development for Solid Rocket Motors (고체 추진기관 설계를 위한 통합 프로그램 개발)

  • Lee, Jun-Ho;Rho, Tae-Ho;Choi, Sung-Han;Suh, Hyuk
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.57-60
    • /
    • 2008
  • There exist a lot of factors and restrictions for the design of solid rocket motors like burning rate, of solid propellant, demanded thrust, chamber pressure, diameter, length, weight and acceleration. For the optimization of these factors and restrictions, integrated design software for internal/external ballistic analysis was developed and verified by the performance test of solid rocket motors.

  • PDF

Fabrication of Superconducting Flux Flow Transistor using Plasma etching (플라즈마 식각을 이용한 초전도 자속 흐름 트랜지스터 제작)

  • 강형곤;임성훈;고석철;한윤봉;한병성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.74-77
    • /
    • 2002
  • The channel of the superconducting Flux Flow Transistor has been fabricated with plasma etching method using ICP. The ICP conditions were 700 W of ICP power, 150 W of rf chuck power, 5 mTorr of the pressure in chamber and 1:1 of Ar : Cl$_2$, respectively. The channel etched by plasma gas showed superconducting characteristics of over 77 K and superior surface morphology. The critical current of SFFT was altered by varying the external applied current. As the external applied current increased from 0 to 12 mA, the critical current decreased from 28 to 22 mA. Then the obtained r$\sub$m/ values were smaller than 0.1Ω at a bias current of 40 mA. The current gain was about 0.5. Output resistance was below 0.2 Ω.

  • PDF

Radiochromic film dosimetry for linac-based stereotactic radiosurgery

  • Han, Seung-Hee;Park, Suk-Won;Oh, Do-Hoon
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.302-304
    • /
    • 2002
  • In linac-based stereotactic radiosurgery, assuring the quality of the planning and delivery of external photon beam requires accurate evaluation of beam parameters, usually including output factors, tissue-phantom ratio and off-axis ratios, and measurement of actual dose distributions from simulated treatment. We're going to test the use of calibrated radio chromic film (Gafchromic film; type MD-55, Nuclear associate) using a Lumiscan 75 digitizer to measure absolute dose and relative dose distributions for linac-based radiosurgery unit Relative dose distribution of a human-style spherical acryl phantom were measured using radiochromic film and calculated by treatment planning system. The absolute dose at the sphere center was measured by radiochromic film and micro chamber (Exradin A-14, 0.009cc). What we want to demonstrate in this work, the 'well selected' radiochromic films when external photon beam are used in linac-based stereotactic radiosurgery are very accurate detector for dosimetry.

  • PDF

Superconducting Flux flow Transistor using Plasma Etching (플라즈마 식각을 이용한 초전도 자속 흐름 트랜지스터)

  • 강형곤;고석철;최명호;한윤봉;한병성
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.5
    • /
    • pp.424-428
    • /
    • 2003
  • The channel of a superconducting flux flow transistor has been fabricated with plasma etching method using a inductively coupled plasma etching. The ICP conditions then were ICP Power of 450 W, rf chuck power of 150 W, the pressure in chamber of 5 mTorr, and Ar : Cl$_2$=1:1. Especially, over the 5 mTorr, the superconducting thin films were not etched. The channel etched by plasma gas showed the critical temperature over 85 K. The critical current of the SFFT was altered by varying the external applied current. As the external applied current increased from 0 to 12 mA, the critical current decreased from 28 to 22 mA. Then the obtained trans-resistance value was smaller than 0.1 $\Omega$ at a bias current of 40 mA.

Dynamics of Coaxial Swirl Injectors in Combustion Environment (연소 조건하의 동축형 분사기의 동적 특성 고찰)

  • Seo Seonghyeon;Han Yeoung-Min;Lee Kwang-Jin;Kim Seung-Han;Seol Woo-Seok;Lee Soo-Yong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.282-287
    • /
    • 2004
  • Unielement combustion tests were conducted using coaxial bi-swirl injectors. Major experimental parameters were a recess length and a fuel-side swirl chamber. Combustion efficiency mainly depends on a mixing mechanism for the present coaxial swirl injectors. Low-frequency pressure excitations around 200Hz were observed for all injectors. However, dynamic behaviors considerably differ for an external and an internal mixing case controlled by a recess length. The internal mixing induces mixture to be biased at a specific frequency in a mass flow rate, which results in a relatively high amplitude of pressure fluctuations but results for the external mixing case show that fuel and oxidizer mixture flow carries more complicated, multiple wave characteristics due to broad mixing region as well as disintegration and merging phenomena of propellant films.

  • PDF

A Study on Passive Microvalve for Glaucoma (녹내장 치료용 수동형 밸브의 제작)

  • Sim, Tae-Seok;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.64-66
    • /
    • 2002
  • This paper reports the design, modeling, fabrication and measurement of passive microvalves applicable to glaucoma implants. The proposed microvalves consisted of microchannels and chambers. The microchannels had a fixed fluidic resistance and generated a pressure difference. The chamber was located in the middle of the microchannels and acted as a buffer preventing an abrupt pressure change from an external variation of the fluid flow. To find optimum design parameters, six kinds of the microvalves were fabricated and experimented.

  • PDF

Optimizing Cleaning Period of Oxide Etcher Using Optical Emission Spectroscopy (광방출 분석법을 이용한 산화물 식각 장비의 세정 주기 최적화)

  • Son, Gil-Su;Roh, Yong-Han;Yeom, Geun-Young;Kim, Su-Hong;Kim, Myoung-Woon;Cho, Hyung-Chul
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.6
    • /
    • pp.416-421
    • /
    • 2011
  • In this paper, the relationship of chamber contamination and the intensity change of specific wavelength was investigated. "diff_CO" formula was introduced to rule out background noise caused by external conditions and to detect when the polymer is removed from the chamber. As RF time increased, diff_CO trend showed the decrease of the maximum peak and increased number of small intensity peaks. From the diff_CO change, it was possible to determine when the chamber needs to be cleaned without opening the chamber.

Anatomy and Histology of the Olfactory Organ of Asian Swamp Eel Monopterus albus (드렁허리 Monopterus albus 후각기관의 해부 및 조직학적 특성 연구)

  • Hyun-Tae Kim
    • Korean Journal of Ichthyology
    • /
    • v.36 no.1
    • /
    • pp.40-47
    • /
    • 2024
  • The anatomy and histology of the olfactory organ of Monopterus albus was investigated using stereo microscopy, light microscopy, and scanning electron microscopy. The external structure of the olfactory organ exhibited closed anterior and posterior nostrils parallel to the skin surface. The interior structure consisted of a pipe-like chamber, and lower and upper accessory nasal sacs. The olfactory chamber was composed of the sensory and non-sensory epithelium, and an unidentified organ. The sensory epithelium of the pseudostratified epithelial layer was composed of olfactory receptor neurons, supporting cells, basal cells, and lymphatic cells; and the non-sensory epithelium of the stratified squamous layer contained stratified epithelial cells and mucous cells with acidic mucopolysaccharides. The presence of intraepithelial blood capillaries and abundant dermal vascularization in the sensory epithelium of the olfactory chamber may provide strong histological evidence that respiration occurs through the olfactory epithelium.